• 제목/요약/키워드: heat sources

검색결과 661건 처리시간 0.022초

The Burdens of Occupational Heat Exposure-related Symptoms and Contributing Factors Among Workers in Sugarcane Factories in Ethiopia: Heat Stress Wet Bulb Globe Temperature Meter

  • Mitiku B. Debela;Achenef M. Begosaw;Negussie Deyessa;Muluken Azage
    • Safety and Health at Work
    • /
    • 제14권3호
    • /
    • pp.325-331
    • /
    • 2023
  • Background: Heat stress is a harmful physical hazard in many occupational settings. However, consequences of occupational heat exposure among workers in a sugarcane factory in Ethiopia are not well characterized. This study aimed to assess the level of occupational heat exposure-related symptoms and contributing factors. Methods: In this cross-sectional study, five workstations were selected for temperature measurement. Heat stress levels were measured using a wet-bulb globe temperature index meter. A stratified random sampling technique was used to select 1,524 participants. Heat-related symptoms were assessed using validated questionnaires. Results: The level of occupational heat exposure was 72.4% (95% CI: 70.2%-74.8%), while 71.6% (95% CI: 69.3%-74.9%) of participants experienced at least one symptom related to heat stress. The most common heat-related symptoms were swelling of hands and feet (78%), severe thirst (77.8%) and dry mouth (77.4%). The identified risk factors were a lack of reflective shields (AOR: 2.20, 95% CI: 1.53, 3.17), not-enclosed extreme heat sources (AOR: 1.76, 95% CI: 1.23, 2.51), a lack of access to shade (AOR: 9.62, 95% CI: 6.20, 14.92), and inappropriate protective clothing provision (AOR: 1.58, 95% CI: 1.27, 2.71). Conclusions: The burden of occupational heat exposure and heat-induced symptoms was high. Lack of reflective shields, the absence of enclosed extreme heat sources, a lack of access to shade, and inappropriate protective clothing provision were considerable attributes of heat stress. Therefore, the use of mechanical solutions to stop heat emissions at their sources and the key factors identified were areas for future intervention.

저온 활용을 위한 실리카겔 흡착식 담수화시스템의 성능연구 (A Performance Study on Silica Gel Adsorption Desalination System Utilizing Low Temperature Heat Sources)

  • 현준호;;이윤준;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제33권6호
    • /
    • pp.39-46
    • /
    • 2013
  • This work introduces a simple one-reactor adsorption desalination system that harnesses low temperature heat sources (solar energy, waste heat), which has been experimentally studied to elicit the most suitable design parameters and operating conditions. The design process of the system was divided into three parts to reflect the operating principle of desalination technology with application of adsorption processes. First, the evaporator for the vaporization of saline water was designed, then the reactor for the adsorption and release of the steam, followed by the condenser for condensation of the fresh water. The specific water yield is measured experimentally with respect to the time while controlling parameters such as heat source temperatures, coolant temperatures, system switching and half-cycle operational times. The present system well demonstrates the applicability of silica gel in relation to adsorption technologies that utilize low temperature heat sources ranging from 60 to $80^{\circ}C$, such as solar energy and waste heat.

온배수를 열원으로 활용하는 생태산업단지 조성에 관한 기초 연구 (Basic study on Eco-industrial Park utilizing thermal effluents as heat source)

  • 김동규;강대석;정용현
    • 수산해양교육연구
    • /
    • 제21권3호
    • /
    • pp.400-408
    • /
    • 2009
  • The purpose of this study is to know the concept of Eco-industrial Park and How to use the thermal effluents from power plants. Thermal effluents, which use sea water for cooling, from power plants have been discharged with about $6{\sim}7^{\circ}C$ higher temperature than near sea area. Therefore, it could effect on the marine ecosystem as a external pressure factor that increase the artificial thermal load in near sea area. The applications of thermal effluents had been surveyed through the several internal and external cases for utilizing heat sources and reducing the thermal load. As the precedence research for applying, the amount of heat sources of thermal effluents was evaluated. When the thermal effluents was fully applied in heat sources and available heat, assume that use heating season by 12 hours a day of demanded available heat, it was possible to calculate total 198 Tcal of energy saving.

해수열원을 이용한 빙상경기장의 에너지절약 방안에 관한 연구 (Energy Saving Strategies for Ice Rink using Sea-Water Heat Source Cooling System)

  • 김삼열;박진영;박재홍
    • 한국태양에너지학회 논문집
    • /
    • 제34권2호
    • /
    • pp.53-59
    • /
    • 2014
  • Ice Rink is energy intensive building type. Concern of energy saving from buildings is one of very important issues nowadays. New and renewable energy sources for buildings are especially important when we concern about energy supply for buildings. Among new and renewable energy sources, use of seawater for heating and cooling is an emerging issue for energy conscious building design. The options of energy use from sea water heat sources are using deep sea water for direct cooling with heat exchange facilities, and using surface layer water with heat pump systems. In this study, energy consumptions for an Ice Rink building are analyzed according to the heat sources of air-conditioning systems; existing system and sea water heat source system, in a coastal city, Kangnung. The location of the city Kangnung is good for using both deep sea water which is constant temperature throughout the year less than $2^{\circ}C$, and surface layer water which should be accompanied with heat pump systems. The result shows that using sea water from 200m and 30m under sea lever can save annual energy consumption about 33% of original system and about 10% of that using seawater from 0m depth. Annual energy consumption is similar between the systems with seawater from 200m and 30m. Although the amount of energy saving in summer of the system with 200m depth is higher than that with 30m depth, the requirement of energy in winter of the system with 200m depth is bigger than that with 30m depth.

지열원과 수열원을 이용한 하이브리드 히트펌프 시스템의 에너지 성능 비교 분석 연구 (A Study on Comparative Analysis of Energy Performance of Hybrid Heat Pump Systems Using Ground Heat Source and Water Heat Source)

  • 박시훈;김종현;민준기
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권4호
    • /
    • pp.59-67
    • /
    • 2021
  • In this study, the performance of the single heat source system and the hybrid system was comparatively analyzed. Case 1 is a ground heat source system, and Case 2 is a water heat source system. Case 3, a hybrid system, reduced the capacity of the ground heat source and applied a water heat source as an auxiliary heat source, and Case 4 was composed of a system that applied a water heat source as an auxiliary heat source to the ground heat source system. As a result of the simulation, in case 3, energy consumption was reduced by up to 2.67% compared to ground sources for cooling. In Case 4, COP was improved by up to 10.02% compared to ground sources during cooling, and EST was calculated to be 2.42℃ lower. During heating, 0.83% was improved compared to the water heat source. At this time, the EST was calculated to be 2.25℃ higher than the water heat source.

레이저를 이용한 유리절단의 유한요소해석 (Finite Element Analysis for Breaking of Glass Using Laser)

  • 조해용;김관우;남기정;이제훈;서정
    • 한국레이저가공학회지
    • /
    • 제9권1호
    • /
    • pp.9-16
    • /
    • 2006
  • Glass is one of brittle materials. Generally, brittle material is weak for tensile stress but strong for compression stress. Laser breaking of glass used this brittle characteristics. Laser breaking of glass was simulated to optimize breaking condition by using commercial FEM code MARC which is applicable to thermo-mechanical coupling analysis. Various shapes of heat sources were applied to the analysis and the distance between heating and cooling source were varied for each simulation. The shapes of heat sources were circle, single and double ellipse and the distance was varied from 0mm to 30mm. Moving heat sources were designed on the basis of experimental condition. As a result, double elliptic shape of heat source was the most suitable among them in laser breaking of glass. And it should be useful to determine optimal condition of laser breaking for glass.

  • PDF

펄스형 Nd:YAG 레이저와 단락이행모드의 직류 GMA 열원을 이용한 하이브리드 용접 공정에 대한 연구 (A Study on the Process of Hybrid Welding Using Pulsed Nd:YAG Laser and Dip-transfer DC GMA Heat Sources)

  • 조원익;나석주
    • Journal of Welding and Joining
    • /
    • 제25권6호
    • /
    • pp.71-77
    • /
    • 2007
  • Until now, many researches on laser-arc hybrid welding processes have been conducted mainly for high power CW laser and high direct current arc to weld the thick steel plates for shipbuilding. Recently, however the usage of thin steel plates, which tend to be deformed easily by thermal energy, is been increasing because of demand of light structure such as car body in the automobile industry. Accordingly, heat sources having relatively low heat input such as pulsed laser, dip-transfer DC GMA and pulsed GMA seem to be applied more increasingly and the study about those heat sources is needed more intensively. Any heat source mentioned above can not stand alone without weld defects at a relatively high welding speed for increasing the welding productivity. This is main reason to apply the hybrid welding process which uses pulsed laser and low-heat-input GMA heat sources simultaneously to weld the thin steel plate. In this study, parameters of pulsed laser and dip-transfer DC GMA welding are studied firstly through preliminary experiments, and then analyzed in the viewpoint of their physical phenomena. Before conducting the hybrid welding, a pulse control technique is developed based on the parallel port communication and Visual C++ 6.0. Owing to development of this technique, interactions of laser and arc pulses can be controlled consistently. Using the pulse control technique, the hybrid welding is conducted and then its interactive welding phenomenon is analyzed.

대류와 전도 열전달을 이용한 전자부품의 냉각특성 수치해석 (Numerical Analysis on Cooling Characteristics of Electronic Components Using Convection and Conduction Heat Transfer)

  • 손영석;신지영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.390-395
    • /
    • 2001
  • Cooling characteristics using convection and conduction heat transfer in a parallel channel with extruding heat sources are studied numerically. A two-dimensional model has been developed for numerical prediction of transient, compressible, viscous, laminar flow, and conjugate heat transfer between parallel plates with uniform block heat sources. The finite volume method is used to solve this problem. The considered assembly consists of two channels formed by two covers and one PCB which has three uniform heat source blocks. Five different cooling methods are considered to find efficient cooling method in a given geometry and heat source. The velocity and temperature fields, local temperature distribution along surface of blocks, and the maximum temperature in each block are obtained.

  • PDF

열전달을 고려한 냉동 사이클의 최적 설계조건 (Optimal Design Condition of Refrigeration Cycle with Heat Transfer Processes)

  • 김수연;정평석
    • 대한기계학회논문집
    • /
    • 제14권1호
    • /
    • pp.225-229
    • /
    • 1990
  • 본 연구에서는 외부조건과 입력이 일정하게 주어져 있는 냉동 사이클에 대하 여 열교환기의 용량을 설계변수로 하여 출력과 효율이 최대가 되는 조건, 즉 최적 설 계조건을 살펴 보고자 한다. 아울러 이 조건과 엔트로피 생성 최소조건과의 관계와 비가역 사이클인 경우도 살펴보았다.

Mass Transfer Experiments for the Heat Load During In-Vessel Retention of Core Melt

  • Park, Hae-Kyun;Chung, Bum-Jin
    • Nuclear Engineering and Technology
    • /
    • 제48권4호
    • /
    • pp.906-914
    • /
    • 2016
  • We investigated the heat load imposed on the lower head of a reactor vessel by the natural convection of the oxide pool in a severe accident. Mass transfer experiments using a $CuSO_4-H_2SO_4$ electroplating system were performed based on the analogy between heat and mass transfer. The $Ra^{\prime}_H$ of $10^{14}$ order was achieved with a facility height of only 0.1 m. Three different volumetric heat sources were compared; two had identical configurations to those previously reported, and the other was designed by the authors. The measured Nu's of the lower head were about 30% lower than those previously reported. The measured angular heat flux ratios were similar to those reported in existing studies except for the peaks appearing near the top. The volumetric heat sources did not affect the Nu of the lower head but affected the Nu of the top plate by obstructing the rising flow from the bottom.