• Title/Summary/Keyword: heat recovery type

Search Result 155, Processing Time 0.023 seconds

A Study on Improvement of Performance for Perforated Type Total HEX Element (다공형 유로를 적용한 전열교환기 소자의 성능향상에 관한 연구)

  • Kwak, Kyung-Min;Bai, Cheol-Ho;Kim, Jee-Yong;Chu, Euy-Sun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.7
    • /
    • pp.529-536
    • /
    • 2007
  • The perforated type element for a heat recovery ventilation system has been studied to improve the performance. Four holes of diameter of 6mm are punched out for each flow channel to break the boundary layer development and increase the turbulence. KS cooling and heating conditions and test procedures are applied for study. The efficiencies are compared to those of the typical element with smooth surface. For cooling operations, the temperature, latent and enthalpy efficiencies increase 2.5%, 18% and 8%, respectively. For heating operations, the temperature, latent and enthalpy efficiencies increase 3%, 5% and 3.2%, respectively.

Development of Heat Exchanger for Fermentation Heat Utilization from Waste Woody Biomass (목질계 폐바이오메스의 발효열이용 열교환기의 개발)

  • Cho, Nam-Seok;Choi, Tae-Ho;Kim, Hong-Eun;Lee, Suk-Ho;Lee, Chung-Koo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.94-104
    • /
    • 2009
  • It is urgently required to develop the production of fermentation-heat energy from the waste agricultural and forest biomass and its effective heat exchanging system for the supply of warm water to rural households and greenhouses. In this study 3 helical-type and 1 plate-type heat exchangers using 3 different waste biomasses [e.g. hardwood (HW) sawdust (100%), softwood (SW) sawdust : HW sawdust (50 : 50) and HW sawdust : grass (90 : 10)] were applied in order to find out the best heat recovery system. The heat exchanger was basically considered to improve the overall heat recovery efficiency, to minimize heat loss and to simplify manufacturing, assembling and breaking up the fermenting beds. The helical-type heat exchanger (HX-H3) installed in fermenting bed of HW sawdust : grass (90 : 10) showed relatively higher temperature profiles, in particular mid- and upper-parts than lower and surface parts during 45-day fermentation process. The maximum temperature was ranged from $40^{\circ}C$ to $65^{\circ}C$ with average $60^{\circ}C$. The water temperature of tank outlet was ranged to $33{\sim}48^{\circ}C$ during whole measuring periods. By the way plate-type one (HX-P) installed in same biomass compositional fermenting bed showed $64.5{\sim}76.5^{\circ}C$ at center part, and $43{\sim}56^{\circ}C$ and $42{\sim}58^{\circ}C$, water tank and tank outlet temperatures, respectively, during 100 day measurement. It could be concluded that the plate-type heat exchanger (HX-P) provides not only the effective heating for the rural households and greenhouses, but also having the best heat recovery performance, easy manufacturing, assembling and breaking up the systems.

Design of a Swash Plate Type of Steam Expander for Waste Heat Recovery (폐열 회수용 사판식 스팀 팽창기 설계)

  • Kim, Hyun-Jae;Kim, Hyun-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.5
    • /
    • pp.313-320
    • /
    • 2011
  • For a steam Rankine cycle to recover waste heat from the exhaust gas of an Internal combustion engine, a swash plate type of expander as a power conversion unit has been designed. Numerical simulation has been carried out to estimate the performance of the designed expander. With the steam pressure and temperature of 35 bar and $300^{\circ}C$ at the expander inlet, respectively, the expander was estimated to produce the shaft power output of about 2.67 kW from the exhaust gas waste heat of 25.2 kW. The expander output increased almost linearly with the amount of exhaust gas waste heat in the range of from 5~40 kW, and the expander and Rankine cycle efficiencies showed gradual decreases in the ranges of 72.2%~69.5% and 10.8%~10.4%, respectively.

A Study on the Release Characteristics of VOCs from Heat Recovery Ventilation System (폐열회수형 환기장치의 휘발성유기화함물 배출 특성에 관한 연구)

  • Kwak, Kyung-Min;Bai, Cheol-Ho;Kim, Jee-Yong;Chu, Euy-Sung
    • Clean Technology
    • /
    • v.13 no.4
    • /
    • pp.281-286
    • /
    • 2007
  • VOCs from the heat recovery ventilation system (total heat exchanger) are measured in this study. Two different types of element (L and M type) from heat recovery ventilating system are tested to study the intial release characteristics of VOCs under KS cooling and heating standard conditions. VOCs are measured for the various flow rates and different operating times. Considering errors in the test method and the measuring instrument, the tested heat recovery ventilating systems was found to release 6 major VOCs, such as acetic acid, 2-butanone (MEK), 2-(methylthio )ethylamine, toluene, styrene, and x-acids (Ion 57). The concentrations of released VOCs are not quite much affected by operating conditions. The results show much larger VOCs concentrations in the cooling mode than in the heating mode, due to the high operating temperatures.

  • PDF

Development of Simulation Model for Waste Heat Recovery from Automotive Engine Exhaust Using Thermoelectric Generator (열전소자를 이용한 자동차 엔진 배기 폐열 회수 시스템 해석 모델 개발)

  • Kim, Ki-Bum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1022-1026
    • /
    • 2013
  • Recently, the waste heat recovery technique using thermoelectric generator (TEG) in automotive engine has emerged to improve thermal efficiency in commercial vehicle. It is not difficult to recognize the numerous attempts that have been made to develop the TEG simulation model, but it is hard to find the model in conjunction with a particular heat engine system. In this study, 1-D commercial software AMESim was used to develop a computational model that can assess waste heat recovery from a diesel engine exhaust using TEG. The developed TEG simulation model can be used for evaluating the TEG performance of various types of TE module, and the diesel engine model can simulate any type of on and off-road diesel engines. The simulation results demonstrated that approximately 544.75W could be recovered from the engine exhaust and 40.4W could be directly converted into electricity using one TE module. The models developed in this study can be easily coupled with each other in the same computational program; thus, the models are expected to provide a viable tool for developing and optimizing a TEG waste heat recovery system in an automotive diesel engine.

A Study on Hydrogen Production with High Temperature Solar Heat Thermochemical Cycle by Heat Recovery (열회수에 따른 고온 태양열 열화학 싸이클의 수소 생산에 관한 연구)

  • Cho, Ji-Hyun;Seo, Tae-Beom
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.2
    • /
    • pp.13-22
    • /
    • 2017
  • Two-step water splitting thermochemical cycle with $CeO_2/ZrO_2$ foam device was investigated by using a solar simulator composed of 2.5 kW Xe-Arc lamp and mirror reflector. The hydrogen production of $CeO_2/ZrO_2$ foam device depending on heat recovery of Thermal-Reduction step and Water-Decomposition step was analyzed, and the hydrogen production of $CeO_2/ZrO_2$ and $NiFe_2O_4/ZrO_2$ foam devices was compared. Resultantly, the quantity of hydrogen generation increased by 52.02% when the carrier gas of Thermal-Reduction step is preheated to $200^{\circ}C$ and, when the $N_2/steam$ is preheated to $200^{\circ}C$ in the Water-Decomposition step, the quantity of hydrogen generation increased by 35.85%. Therefore, it is important to retrieve the heat from the highly heated gases discharged from each of the reaction spaces in order to increase the reaction temperature of each of the stages and thereby increasing the quantity of hydrogen generated through this.

Economic Analsys of Cooling-Heating System Using Ground Source Heat in Multi Family Apartment (공동주택에서 지열 냉난방 시스템 적용시 경제성 분석)

  • Park, Yongboo;Park, Jongbae;Lim, Haesik;Baek, Sungkoon
    • Journal of the Korean GEO-environmental Society
    • /
    • v.8 no.3
    • /
    • pp.11-18
    • /
    • 2007
  • This paper studied the economical efficiency of ground source heat pump system under various conditions in apartments which have important effects on the housing market. And this study analysed the initial cost increase, saved managing cost and recovery time of initial cost. Analysis result showed as time of heating-cooling and water heating increases, the amount of saved managing cost increased much than the initial construction cost, so recovery time shortened. And as the net area of apartment increases, the recovery time increased. The study of the relation between the installation type and recovery time of initial construction cost showed when heat-cooling system adapted ground source heat and water heating system adapted waste heat, the initial construction cost was recovered most quickly. When Ground Source Heating system was used for the heating-cooling and water heating system, ground source heating system was used for the heating-cooling and waste heat used for water heating, and ground source heating system was used for the heating-cooling and LNG used for water heating, the construction cost increased 72,000, 66,900 and 62,300 won each per $m^2$ compared to the current system (package air-conditioner, heating and water heating using LNG).

  • PDF

STEAM DRUM DESIGN FOR A HRSG BASED ON CFD (수치해석을 이용한 HRSG(Heat Recovery Steam Generator) 증기 드럼 설계)

  • Ahn, J.;Lee, Y.S.;Kim, J.J.
    • Journal of computational fluids engineering
    • /
    • v.16 no.1
    • /
    • pp.67-72
    • /
    • 2011
  • HRSG (Heat Recovery Steam Generator) is a boiler to recover heat from the exhaust gas of an engine and to generate steam for more power generation or process. For the HRSG, water-tube type boiler is commonly adopted to accommodate the working pressure or capacity requirement of the system. The water-tube type boiler has a steam drum to separate steam from the water-steam mixture supplied from the evaporator tube (riser). The drum should be sized properly to separate the steam by the gravity and auxiliary internals, such as a demister, which are installed to filter the steam. To size the steam drum and to estimate the filter efficiency of drum internals, the velocity distribution inside the drum needs to be identified. In the present study, a series of CFD has been conducted to find the velocity distributions inside steam drums for conventional HRSGs and water-tube type industrial boilers. The velocity distributions obtained from the simulation have been normalized and a correlation to predict them has been found. The correlation is applied to the steam drum design by determining a proper position of a demister to show proper separation performance.

Optimization Study on the Performance Analysis of Organic Rankine Cycle for Characteristics of Low Temperature Heat Sources (저온열원의 특성에 따른 ORC 성능해석 최적화 연구)

  • Eom, Hong-Sun;Yoon, Cheon-Seog;Kim, Young-Min;Shin, Dong-Gil;Kim, Chang-Gi
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.1
    • /
    • pp.51-60
    • /
    • 2012
  • Optimization procedures of performance analysis for ORC(Organic Rankine Cycle) system are established to the characteristics of low temperature heat sources such as open-type and closed-type. Effective heat recovery and heat extraction related to maximum power of the cycle as well as heat quality and thermal efficiency must be considered in the case of the open-type low temperature heat source. On the other hand, in the case of the closed-type low temperature heat source, only thermal efficiency is important due to constant heat input. In this study, thermal efficiency and exergy efficiency representing a level of close to Carnot cycle are studied, as useful index for the optimization of the ORC system. To validate the results of cycle analysis, those are compared with appropriate experimental data of ORC system as a thermal efficiency point of view.

Analysis and Verification of High Temperature Heat Pump Dryer using Waste Heat Recovery Type for R245fa Refrigerant (배기가스 배열을 활용한 R245fa 냉매용 고온 히트펌프 건조기의 해석 및 검증)

  • Bae, Kyung-Jin;Cha, Dong-An;Kwon, Oh-Kyung
    • Journal of Power System Engineering
    • /
    • v.20 no.2
    • /
    • pp.73-78
    • /
    • 2016
  • In this study, the performance characteristics of a high temperature heat pump dryer that is able to raise the air temperature up to $80^{\circ}C$ by using waste heat as heat source were investigated numerically. The main components of the heat pump dryer were modeling as a compressor, condenser, evaporator and expansion device, and R245fa was selected as refrigerant. Experiments were also conducted to validate the numerical data. As a result, when the evaporator air inlet temperature increased from $50^{\circ}C$ to $65^{\circ}C$, the numerical results of the hot air temperature at outlet and heat pump COP were about 8~11% and 5~8% higher than that of experimental ones, respectively.