• Title/Summary/Keyword: heat flow measurement

Search Result 288, Processing Time 0.027 seconds

Heat Transfer and Flow Characteristics on Co-rotating Disks with a Ventilation Hub in Hard Disk Drive (유츨 허브를 갖는 HDD내 동시회전디스크 표면에서의 열전달 및 유동특성 해석)

  • Cho, Hyung-Hee;Won, Chung-Ho;Goo-Young, Ryu
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.382-389
    • /
    • 2001
  • In the present study, local heat transfer rates for co-rotating disks with two modified hubs having ventilation holes are investigated for Rossby number of 0.04, 0.1 and 0.35 to evaluate the influence of incoming flows through hub holes. A naphthalene sublimation technique is employed to determine the detailed local heat/mass transfer coefficients on the rotating disks using the heat and mass transfer analogy. Flow field measurements are conducted using Laser Doppler Anemometry (LDA) and numerical calculations are performed simultaneously to analyze the flow patterns induced by the disk rotation. The basic flow structure in a cavity between co-rotating disks consists of three regions; the solid-body rotating inner region, the outer region with turbulence vortices and the shroud boundary layer region. The heat/mass transfer. rates on the co-rotating disks are very low near the hub due to the solid-body rotation and those increase rapidly in the outer region due to turbulence mixing. The modified hubs with ventilation holes enhances significantly the heat/mass transfer rates on the region near the hub. The results also show that the heat transfer of Hub-2 is superior to that of Hub-1, but Hub-1 is more profitable for destructing the solid-body rotating inner region.

  • PDF

Development of Thermal Mass Flow Meter (열전달 질량유량계 개발)

  • Chi, Daesung
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.118-122
    • /
    • 1999
  • Thermal mass flow meter was developed using principle of convective heat transfer. The advantage of thermal mass flow meter is measuring mass flow directly, therefore, it is not required to use densitometer or temperature/pressure and DP gages. The final accuracy of this thermal mass flow meter is $\pm1.0{\%}$ or better, reproducibility is $\pm0.2{\%}$, and the response time is 600 ms. The thermal mass flow meter was developed from a single point to multi-points (maximum is 9 points), and the number of points is determined according to desired accuracy and size of piping/duct. Since this thermal mass flow meter adopted microprocessor based design, it is intrinsically accurate, self-error detectable, and has self-diagnosis function. The applications of this thermal mass flow meter are for measurement and control of HVAC air flow, other gas flow, and liquid flow.

  • PDF

Experimental investigation of two-phase flow and wall heat transfer during reflood of single rod heater (단일 가열봉의 재관수 시 2상유동 및 벽면 열전달에 관한 실험적 연구)

  • Park, Youngjae;Kim, Hyungdae
    • Journal of the Korean Society of Visualization
    • /
    • v.18 no.3
    • /
    • pp.23-34
    • /
    • 2020
  • Two-phase flow and heat transfer characteristics during the reflood phase of a single heated rod in the KHU reflood experimental facility were examined. Two-phase flow behavior during the reflooding experiment was carefully visualized along with transient temperature measurement at a point inside the heated rod. By numerically solving one-dimensional inverse heat conduction equation using the measured temperature data, time-resolved wall heat flux and temperature histories at the interface of the heated rod and coolant were obtained. Once water coolant was injected into the test section from the bottom to reflood the heated rod of >700℃, vast vapor bubbles and droplets were generated near the reflood front and dispersed flow film boiling consisted of continuous vapor flow and tiny liquid droplets appeared in the upper part. Following the dispersed flow film boiling, inverted annular/slug/churn flow film boiling regimes were sequentially observed and the wall temperature gradually decreased. When so-called minimum film boiling temperature reached, the stable vapor film between the heated rod and coolant was suddenly collapsed, resulting in the quenching transition from film boiling into nucleate boiling. The moving speed of the quench front measured in the present study showed a good agreement with prediction by a correlation in literature. The obtained results revealed that typical two-phase flow and heat transfer behaviors during the reflood phase of overheated fuel rods in light water nuclear reactors are well reproduced in the KHU facility. Thus, the verified reflood experimental facility can be used to explore the effects of other affecting parameters, such as CRUD, on the reflood heat transfer behaviors in practical nuclear reactors.

A Study on the Flow Characteristics according to the Shapes of Rod on Impinging Jet by PIV Measurement (충돌 Jet에서 Rod 형상에 따른 유동특성의 PIV 계측에 의한 연구)

  • 나우정;정진도;송민근;이상범;손승우;주은선
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.152-161
    • /
    • 2004
  • The thermal load is a very important problem to be solved in many industrial systems including the electronic equipment. Impinging Jets have been known to provide a large heat transfer rates on surface for many years. The turbulence enhancement of fluid flow is requested for the efficiency elevation of heat transfer. A study on flow fields by rods attached to the wall surface as a promoter of turbulence enhancement has been carried out. The exact analysis on chracteristics of impinging jet field is requested to obtain the optimum design of the impinging jet system. By visualizing the flow field and processing the high digital image by computer PIV can afford exact data on the velocity vector kinetic energy and turbulence intensity in the complex turbulence field. In this study. three kinds of rod shape such as square. triangle. and semicircle are selected as the turbulence promoter. Nozzle diameters are 10mm. 17mm. and 23mm. And the analysis of the flow characteristics due to the above rods is carried out at Re No. 2.000, 3.000. and 4,000 by PIV measurement. It is clarified that the rod setup is very useful to obtain the turbulence enhancement and the turbulence intensity according to the shapes of rod appears large in order of the shapes of rod such as square 〉 triangle 〉semicircle.

Fiber optic distribution temperature sensing in a borehole heat exchanger system (광섬유 센서를 이용한 지중 열교환기 시스템 온도 모니터링)

  • Shim, Byoung-Ohan;Lee, Young-Min;Kim, Hyoung-Chan;Song, Yoon-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.451-454
    • /
    • 2006
  • Fiber optic distributed temperature sensing and thermal line sensor are applied in an observation borehole and a loom deep borehole heat exchanger. For the case of permanently installed system fiber optic DTS is very useful. By comparing with TLS, fiber optic DTS shows good accuracy and reliability. Ground water flow can give influences at heat exchange rate of the heat pump system. According to the hydraulic characteristics and temperature-depth profile, we consider that temperature-depth profile do not seem to be dependent on ground water flow. A permanent installation of fiber optic cable is expected as a reliable temperature measurement technique in a borehole heat exchanger system.

  • PDF

Heat Transfer Characteristics on a Single Rotating Disk with a Shrouded Cover (슈라우드로 차폐되어진 단일회전디스크 표면의 열전달 특성)

  • Ryu, Goo-Young;Won, Chung-Ho;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.8
    • /
    • pp.1029-1037
    • /
    • 2000
  • The present study investigates the local heat/mass transfer characteristics on a rotating disk which is the top disk covered with a shroud in HDD. The naphthalene sublimation technique is employed to determine the local heat/mass transfer coefficients on the rotating disk. Flow field measurements using Laser Doppler Anemometry (LDA) and numerical calculations are performed to analyze the flow patterns induced by the disk rotation. HDD has been developed for compactness and speedy data access, thus the rotating velocity of the disk is increased and the height of a hub is decreased. The experiments are conducted for the various hub heights of 5, 10 and 15 mm, for the rotating Reynolds numbers of $5.5{\times}10^4$ to $1.1{\times}10^5$ and for the effects of the presence of a read/write head arm. The results show that the heat transfer on the rotating disk is enhanced considerably for the decrease of the hub height and for the increase of the rotating Reynolds number. The head arm inserted in the cavity decreases the heat transfer despite the enhancement of tangential RMS velocity because of the deficit of the momentum in the flow field.

Rapid Cooling Mechanism Utilizing Acoustic Streaming Generated by Ultrasonic Vibrations (초음파 진동에 의해 발생된 음향유동을 활용한 급속냉각 메카니즘)

  • Loh, Byoung-Gook;Kwon, Ki-Jung;Lee, Dong-Ryul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.10 s.115
    • /
    • pp.1057-1066
    • /
    • 2006
  • Acoustic streaming Induced by longitudinal vibration at 30 kHz is visualized for a test fluid flow between the stationary glass plate and ultrasonic vibrating surface with particle imaging velocimetry (PIV) To measure an increase in the velocity of air flow due to acoustic streaming, the velocity of air flow in a gap between the heat source and ultrasonic vibrator is obtained quantitatively using PIV. The ultrasonic wave propagating into air in the gap generates steady-state secondary vortex called acoustic streaming which enhances convective cooling of the stationary heat source. Heat transfer through air in the gap is represented by experimental convective heat transfer coefficient with respect to the gap. Theoretical analysis shows that gaps for maximum heat transfer enhancement are the multiple of half wavelength. Optimal gaps for the actual design are experimentally found to be half wavelength and one wavelength. A drastic temperature variation exists for the local axial direction of the vibrator according to the measurement of the temperature distribution in the gap. The acoustic streaming velocity of the test fluid in the gap is at maximum when the gap agrees with the multiples of half wavelength of the ultrasonic wave, which are specifically 6 mm and 12 mm.

Numerical Analysis of Micro-jet Array Cooling Device with Various Configurations

  • Jung, Yang-Ki;Lee, In-Chan;Ma, Tae-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.2
    • /
    • pp.39-45
    • /
    • 2005
  • Numerical and visualization procedures are used in a finite difference grid to analyze and better understand the heat transfer in the MEMS based air micro-jet array (MIA) impingement cooling device. The Navier-Stokes (NS) equations with incompressible flow are solved using an implicit procedure. The temperature contour and velocity vector visualization diagrams are used for illustration. The computed temperature distribution at the bottom of the MIA is in good agreement with the experimental measurement data. The parameters are investigated to improve the efficiency of heat transfer in the MIA. The optimum configuration of the MIA is suggested. The present modeling explains the flow phenomenon and yields valuable information to understand the flow and heat transfer in MIA.

Heat Transfer Measurement Using a Transient Liquid Crystal Technique and Numerical Anlysis (과도액정기법을 이용한 열전달 측정 및 수치해석)

  • Hong Cheol-Hyun;Lee Ki-Baik;Yang Jang-Sik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.68-77
    • /
    • 2005
  • A transient liquid crystal technique has become one of the most effective ways in measuring the local heat transfer coefficients on the entire surface. The key Point of this technique is to convert the inlet flow temperature into an exponential temperature profile using a mesh heater. In order to verify the validity of this technique. the heat transfer characteristics on the wall surface by a pair of longitudinal vortices is investigated experimently and numerically. A standard ${\kappa}-{\varepsilon}$ is used for the numerical analysis of turbulent flow field. It is found from experiment and numerical analysis that two peak values exist over the whole domain. as the longitudinal vortices move to the farther downstream. these peak values decrease and the dimensionless averaged Nusselt number with the lapse of time is maintained nearly at constant values. The experiment results obtained from the present experiment in terms of the transient liquid crystal technique are in good agreement with the numerical results. Therefore, the transient liquid crystal technique developed for the measurement of heat transfer coefficient is proved to be a valid method.

Comparative Analysis of Wind Flows in Wind Corridor Based on Spatial and Geomorphological Characteristics to Improve Urban Thermal Environments (도시 열환경개선을 위한 공간지형적 특성에 따른 바람길 유동 비교 분석)

  • SEO, Bo-Yong;JUNG, Eung-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.20 no.2
    • /
    • pp.75-88
    • /
    • 2017
  • This study analyzed wind flows based on spatial and geomorphological characteristics of Daegu Metropolitan City. A three-stage analysis was performed, starting with a comparison of meteorological relationships between local wind direction (synoptic wind) and local wind flow. In the second stage the study area was subdivided into districts and suburban districts to analyze the relative change of local wind flow. In stage three, the formation of wind corridor for local wind flow, wind flow for the entire urban space, and spatial relationships between flows were verified comparatively using KLAM_21. Three results are notable, the first of which is a low correlation between synoptic wind of a region, and local wind, flow in terms of meteorology. Secondly, observations of local wind flow at five downtown districts and two suburban districts showed that there were diverse wind directions at each measurement point. This indicates that the spatial and geomorphological characteristics of areas neighboring the measurement points could affect the local wind flow. Thirdly, verifying the results analyzed using KLAM_21, compared to Atomatic Weather System(AWS) measurement data, confirmed the reliability of the numerical modelling analysis. It was determined that local wind flow in a city performs a spatial function and role in ameliorating the urban heat island phenomena. This indicates that, when an urban planning project is designed, the urban heat island phenomena could be ameliorated effectively and sustainably if local wind flow caused by immediate spatial and geomorphological characteristics is confirmed systematically and techniques are intentionally applied to connect the flows spatially within areas where urban heat islands occur.