• 제목/요약/키워드: heat equivalent

검색결과 415건 처리시간 0.022초

관내연기 분무류의 응축열전달 (Heat Transfer of Condensation by the Injecting Steam Flow In Tube)

  • 김시영
    • 수산해양기술연구
    • /
    • 제20권2호
    • /
    • pp.137-142
    • /
    • 1984
  • 수평관내 증기분무류의 응축열전달에 관하여 실험을 행하고 상당 Reynolds수를 근거로한 열전달효과와의 비교에서 그 결과를 요약하면 다음과 같다. 1. 관내 응축증기 분무류일 경우의 벽면전단응력의 식은 다음과 같이 쓸 수 있다. root($\tau$하(0)/$\tau$하(0v))=1+1.46X 하(tt) 상(0.20). 2. 분무류의 응축열전달효과가 상당 Reynolds수에 의한 값보다 대체로 낮게 나타난 이유는 관내 반경 및 길이방향의 불균일한 액막형성에 의한 Reynolds수 측정값의 차이 때문이다. 3. 분무류의 응축열전달효과에 의한 N sub(u)의 값은 다음과 같다. N 하(u)=1.08$\times$[{$\rho$ 하(l) d/$\mu$ 하(l)}/{$\delta$+(2.5/P 하(rl)) ln(y 하(i)/$\delta$)}]$\times${$\tau$ 하(0)/ $\rho$ 하(l)} 상(1/2)

  • PDF

월성1호기 사용후 핵연료 건식저장 캐니스터의 열적 안전성에 미치는 대기 조건 인자의 영향 (Parametric Effects of Ambient Conditions on Thermal Safety of Wolsong (CANDU) Unit 1 Spent Fuel Dry Storage Canister)

  • Park, Jong-Woon;Chun, Moon-Hyun;Shon, Soon-Hwan;Song, Myung-Jae
    • Nuclear Engineering and Technology
    • /
    • 제25권1호
    • /
    • pp.166-177
    • /
    • 1993
  • 사용후 핵연료 건식 저장 캐니스터의 핵연료 바스켓 안에 있는 CANDU 37소자 핵연료 다발의 최대 온도를 계산하기 위한 단순화된 열해석 방법과 함께 대기 조건 인자들이 캐니스터 내부의 최대 핵연료 온도에 미치는 영향을 조사하기 위해 수행한 표본 해석 결과를 제시하였다. 3가지 모우드(mode)의 열전달이 공존하는 캐니스터 내부핵연료 다발의 복잡한 기하학적 구조에 대한 다차원열전달 문제를 풀기 위하여 건식저장 캐니스터에 저장된 CANDU 사용후 핵연료 다발들을 등가 및 동심의 핵연료 실린더(cylinder)로 대치하였다. 추가적인 입력 자료 및 열전달 상관식을 이용하여 등가 핵연료 실린더의 단순화된 축대칭, 2차원, 복수 모우드(multi-mode)의 열전달 문제를 기존의 컴퓨터 코드인 HEATING5로 해석하였다. 예측한 온도 분포와 식물 모형 실험 결과의 비교는 만족스러울 정도로 일치함을 보여주고 있다.

  • PDF

고혈압환자의 폭염 적응력 증진을 위한 프로그램 효과 (Effects of an Extreme Heat Adaptation Program in Hypertensive Patients)

  • 정성희;김남순;채수미;이은주
    • Journal of Korean Biological Nursing Science
    • /
    • 제16권3호
    • /
    • pp.164-172
    • /
    • 2014
  • Purpose: The purpose of this study was to identify the effects of an extreme heat Adaptation Program on the blood pressure, stress response, self-efficacy, and knowledge of management of hypertension and extreme heat of patients who suffered from hypertension. Methods: A quasi-experimental study with a non-equivalent control group pretest-posttest design was used. The data collection period was between July 2 and August 20, 2012. Thirty-seven patients participated in the study (18 in the experimental group and 19 in the control group). Data were analyzed using $X^2$-test, t-test, and Cronbach's alpha coefficients with SPSS/WIN 19.0. Results: Patients who participated in the program showed statistically significant improvements in systolic blood pressure (SBP), self-efficacy, and knowledge of management of hypertension and extreme heat. Conclusion: The results indicate that this extreme heat adaptation program can be utilized for patients suffering from hypertension in order to reduce their SBP and to increase self-efficacy and knowledge of management of hypertension and extreme heat. Therefore, it is recommended that this program be used for elderly patients suffering from chronic disease.

액체질소에 대한 증발 열전달 촉진 및 압력강하 성능 (Performance of Evaporation Heat Transfer Enhancement and Pressure Drop for Liquid Nitrogen)

  • 남상철;이상천;박병덕
    • 대한기계학회논문집B
    • /
    • 제24권3호
    • /
    • pp.363-372
    • /
    • 2000
  • An experiment was carried out to evaluate the heat transfer enhancement and the pressure drop characteristics for liquid nitrogen using wire-coil-insert technique under horizontal two-phase conditions. The tube inner diameters were 8 mm and 15 mm, respectively and the tube length was 4.7 m. The helix angle of the wire coil insert was $50^{\circ}$ and its length was 4.7 m. Heat transfer coefficients for both the plain and the enhanced test tubes were calculated from the measurements of temperatures, flow rates and pressure drops. A correlation in a power-law relationship of the Nusselt number, Reynolds number and Prandtl number for the heat transfer was proposed which can be available for design of cryogenic heat exchangers. The correlation showed that heat transfer coefficients for the wire-coil inserts were much higher than those for plain tubes, increased by more than $1.8{\sim}2.0$ times depending upon the range of the equivalent Reynolds number. The correlation was compared with other various correlations in the turbulent flow conditions.

$Na_4P_2O_7{\cdot}10H_2O$의 축열방열시 열전달 특성에 관한 실험적 연구 (An experimental study of heat transfer with $Na_4P_2O_7{\cdot}10H_2O$ as P.C.M.)

  • 이채문;임장순
    • 태양에너지
    • /
    • 제9권1호
    • /
    • pp.70-77
    • /
    • 1989
  • Sodium pyrophosphate that melting point is $79-80^{\circ}C$ have been Studied on heat storage and heat discharge. In heat storage process, sodium pyrophosphate was kept up initial temperature $50^{\circ}C,\;60^{\circ}C,\;70^{\circ}C$ which melt by heated water at temperature $85^{\circ}C,\;90^{\circ}C,\;95^{\circ}C$. In heat discharge process, initial temperature of sodium pyrophosphate was maintained at temperature $85^{\circ}C,\;90^{\circ}C,\;95^{\circ}C$ which varied cooling temperature $50^{\circ}C,\;60^{\circ}C,\;70^{\circ}C$. The experiment has been reached conclusions as follows. 1) Heat transfer properties of phase change material is controlled by conduction during heating and cooling process. 2) The temperature increased rapidly at initial stage and transient region increase slowly because of characteristic of latent heat. 3) The lower cooling water temperature is the less the time that get to thermal equivalent state take during discharge process. 4) The higher cooling water temperature is the less temperature difference between top and bottom in P.C.M during discharge process.

  • PDF

열교환기용 고정형 튜브시트의 설계프로그램 개발 (Development of Design-Program of Fixed Type Tube-Sheet for Heat Exchanger)

  • 공제석;이경진;한정영;조종래;배원병
    • 소성∙가공
    • /
    • 제15권3호
    • /
    • pp.206-212
    • /
    • 2006
  • Design programs of tube-sheet for heat exchanger based on the related engineering society codes have been widely used. But it is not easy fer beginners to use the design programs. So we need to develop an easy program for design of tube-sheet for heat exchanger. This paper describes a developed design-program of tube-sheet fur heat exchanger. The developed program was coded on boiler theory and pressure vessel codes, provided by TEMA(Tubular Exchanger Manufactures Association) and ASME(American Society of Mechanical Engineers). Visual Basic, which is convenient for beginners to deal with, was used in the programming. Also a finite element analysis of tube-sheet for heat exchanger was carried to verify this developed program by using a commercial software, ANSYS. In the finite element analysis, tube and tube-sheet of heat exchanger were substituted by solid plate having equivalent properties for convenience of calculation. The thickness of tube-sheet obtained by the developed design-program was in good agreement with that of tube-sheet by FEA.

Thermal cracking analysis of concrete with cement hydration model and equivalent age method

  • Tian, Ye;Jin, Xianyu;Jin, Nanguo
    • Computers and Concrete
    • /
    • 제11권4호
    • /
    • pp.271-289
    • /
    • 2013
  • In this research, a developed microstructural model of cement particles was presented to describe the cement hydration procedure. To simplify the hydration process, the whole hydration was analyzed in a series of sub-steps. In each step, the hydration degree, as well as the microstructural size of the hydration cell, was calculated as a function of the radius of the unreacted cement particles. With the consideration of the water consumption and the reduction of the interfacial area between water and hydration products, the micro-level expressions of the cement hydration kinetics were established. Then the heat released and temperature history of the concrete was carried out with the hydration degree obtained from each sub-steps. The equivalent age method based on the Arrhenius law was introduced in this research. Based on the equivalent age method, a maturity model was applied to describe the evolution of the mechanical properties of the material during the hydration process. The finite element program ANSYS was used to analyze the temperature field in concrete structures. Then thermal stress field was calculated using the elasticity modulus obtained from code formulate. And the risk of thermal cracking was estimated by the comparison of thermal stress and concrete tensile strength.

2 kW급 고체산화물연료전지의 고온배기가스 폐열회수를 위한 일체형 Hot BoP의 설계 및 성능 평가 (Design and Performance Evaluation of Integral-type Hot BoP for Recovering High-temperature Exhaust Gas in 2 kW Class SOFC)

  • 김영배;김은주;윤종혁;송형운
    • 공업화학
    • /
    • 제30권1호
    • /
    • pp.62-67
    • /
    • 2019
  • 본 연구에서는 2 kW급 SOFC (solid oxide fuel cell)에서 배출되는 고온 배기가스의 폐열회수를 위한 일체형 Hot BoP의 설계와 성능 분석에 대한 연구를 수행하였다. Hot BoP 시스템은 스택 배기가스의 연소를 위한 촉매 연소기와 연소 후 배기가스의 폐열회수를 위한 원통다관형 공기예열기 및 스팀발생기로 구성되었다. 시스템 설계에서 폐열회수 시스템의 배치에 따른 최대 허용열용량을 산출하여 열분배 공정을 분석하였으며, 열전달 방정식을 통하여 공기예열기 및 스팀발생기의 상세설계를 수행하였다. Hot BoP는 방열손실의 저감을 위해 일체형으로 제작되었으며, SOFC와 연계운전을 가정한 스택배기가스를 모사하여 성능실험에 사용하였다. Hot BoP 성능실험에서 부하별 열전달량 및 시스템 효율이 측정 및 분석되었으며, 당량비에 따른 배기가스의 CO 발생량을 측정하여 연소성을 분석하였다. 실험결과로써, 2 kW급 SOFC 정격운전시 배기가스 연소열부하 기준으로 hot BoP의 열적 효율은 약 60%이며, 연소 후 배기가스의 CO 발생량은 당량비 0.25 이상에서 급격히 감소되는 것으로 나타났다.

전폐형 유도전동기의 온도분포에 관한 수치 및 실험적 해석 (Numerical and experimental analysis of temperature distribution in TEFC induction motor)

  • 윤명근;고상근;한송엽;이양수
    • 대한기계학회논문집B
    • /
    • 제21권3호
    • /
    • pp.457-472
    • /
    • 1997
  • We studied the temperature distribution and heat transfer characteristics of TEFC induction motor with thermal network program for more efficient design and better cooling performance of it. We knew the characteristics and the windage loss of outer cooling fan from fan test experiments. Frame axial and peripheral heat transfer coefficients and endwinding heat transfer coefficient were measured by various model experiments and then, compared with other experimental results. Frame was the main heat transfer surface, load-side and fan-side surface were not thermally symmetric from the heat flux distribution analysis. Steady and unsteady temperature distributions were measured by real motor experiments. From the results, we knew that rotor surface temperature was higher than coil temperature and the hottest spot in the coil was loadside endwinding outside surface. We compared the simulation results with those of real motor test and the two results showed a good agreement.

국산 플럭스 코어드 와이어 용접에서 입열량이 용접부의 미세조직과 인성에 미치는 영향 (A Study on the Effect of Heat Input on the Microstructure and Toughness of Weldments Made by Domestic Flux Cored Wires.)

  • 고진현;국정한
    • Journal of Welding and Joining
    • /
    • 제11권4호
    • /
    • pp.57-69
    • /
    • 1993
  • In the present study, the microstructure and Charpy V notch toughness of multipass $CO_2$ FCA weldment in three different heat inputs(1-3KJ/mm)were investigated. The weldments using two different domestic FCAW wires(AWS E71T-1 and E71T-5 equivalent) in C-Mn steel were chemically analysed. The following conclusions can be inferred. 1. T-1 wire Showed a stable arc transfer, less spatter and harsh, a better bead spreading and easy slag removal, whereas T-5 wire suffered from the arc stability, which tended to increase spatter and produce a more convex bead. 2.The microsturctures of the top beads of the weldments in three different heat inputs consisted of coarse-grained boundary ferrite and Widmanstatten ferrite side plate with increasing heat inputs. The modest fraction of acicular ferrite in the two wire weldments was observed in the 2KJ/mm heat input. 3.The fine-grained reheated zones of both welds consisted of a duplex microstructure of polygonal ferrite and second phases. 4. The basic flux weldment of T-5wires showed a higher Charpy impact property than that of T-1 wires because of a higher fraction of acicular ferrite in the weld microstructure.

  • PDF