• Title/Summary/Keyword: heat equivalent

Search Result 416, Processing Time 0.025 seconds

Integral effect tests for intermediate and small break loss-of-coolant accidents with passive emergency core cooling system

  • Byoung-Uhn Bae;Seok Cho;Jae Bong Lee;Yu-Sun Park;Jongrok Kim;Kyoung-Ho Kang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2438-2446
    • /
    • 2023
  • To cool down a nuclear reactor core and prevent the fuel damage without a pump-driven active component during any anticipated accident, the passive emergency core cooling system (PECCS) was designed and adopted in an advanced light water reactor, i-POWER. In this study, for a validation of the cooling capability of PECCS, thermal-hydraulic integral effect tests were performed with the ATLAS facility by simulating intermediate and small break loss-of-coolant accidents (IBLOCA and SBLOCA). The test result showed that PECCS could effectively depressurize the reactor coolant system by supplying the safety injection water from the safety injection tanks (SITs). The result pointed out that the safety injection from IRWST should have been activated earlier to inhibit the excessive core heat-up. The sequence of the PECCS injection and the major thermal hydraulic transient during the SBLOCA transient was similar to the result of the IBLOCA test with the equivalent PECCS condition. The test data can be used to evaluate the capability of thermal hydraulic safety analysis codes in predicting IBLOCA and SBLOCA transients under an operation of passive safety system.

Preparation and Characterization of Hydrophilic Aminated poly(styrene-ethylene-butylene-styrene) Polymer Membrane (친수성 아민화된 poly(styrene-ethylene-butylene-styrene) 고분자 분리막 제조 및 투습도 특성평가)

  • Son, Tae Yang;Kim, Ji Hyun;Park, Chi Hoon;Nam, Sang Yong
    • Membrane Journal
    • /
    • v.27 no.4
    • /
    • pp.336-343
    • /
    • 2017
  • These days, the quality of indoor air is a very important concept for modern people who have lived in building and is a matter of new thinking. The quality is determined by the temperature and humidity of indoor air. In addition, there is a disadvantage in that energy consumption is severe for indoor air improvement. Therefore, researches on methods to solve such problems using total heat exchange have been actively conducted. So, in this study, aminated poly(styrene-ethylene-butylene-styrene) polymers were synthesized by introducing a hydrophilic substituent, ammonium, into main chain and the properties of synthesized polymers were evaluated. The synthesis was carried out through chloromethylation and amination reactions to introduce ammonium into main chain. As a result, the water uptake and the ion exchange capacity of the synthesized polymers increased as the content of the reaction reagent solution increased. It was confirmed that the important data at the total heat exchange membrane, water vapor transmission rate also increased according to temperature, equivalent.

Effect of Heat Treatment on High Temperature Fatigue Strength Characteristics of STB2 Bearing Steel (STB2강의 고온피로강도 특성에 미치는 열처리의 영향)

  • Oh, Sae-Kyoo;Kim, Yeon-Ho;Lee, Sang-Guk;Lee, Jong-Du
    • Journal of Ocean Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.138-144
    • /
    • 1989
  • It has been very important in various industry fields to improve the fatigue strength characteristics of bearings such as bearing life, fatigue limit, etc., because such poor properties could result in shortening the machinery life as well as in decreasing the accuracy. However, no successful heat treatment criterion seems to be available at present. In this study, the effect of the $170^{\circ}C\times120min$ tempering cycles repeated after $380^{\circ}C\times80min$ oil quenching for $800^{\circ}C$ spheroidizing-annealed bearing steel (STB2) as base metal on the $120^{\circ}C$ high temperature rotary bending fatigue strength characteristics were investigated, including the effects on hardness, Charpy impact value and micro-structure, in order to seek for the best heat treatment condition finally. The important results obtained are as follows : 1) The optimal cycle of tempering so that the fatigue strength .sigma. could become the highest was the 4th cycle. And it is confirmed that this $\sigma_{F}$ is about 6 times more increased than that of base metal, and about 1.3 times more increased than the case of the 1 cycle tempered. 2) As a result of the investigation for the effects of tempering cycles on hardness, the hardness at the tempering number of 2 thru 5 cyles was not decreased severely ; only about 10% decrease from those of the quenched and 1 cycle tempered case. Such hardness is equivalent to $H_{R}$/C61-62 with no bad effect on anti-abrasion of bearing steel. 3) In the case of 2 thru 5 cycle tempering as well as 1 cycle tempering, the impact value was not so improved comparing with the case of quenching, but an increase of 5 to 10% could be expected at least. 4) It was experimentally confirmed that the control of the mechanical properties improvement such as fatigue strength and fatigue life for bearing steels could be possible by the number of tempering cycles.

  • PDF

Effect of Heat Treatment on High Temperature Fatigue Strength Characteristics of STB2 Bearing Steel (STB2강의 고온피로강도 특성에 미치는 열처리의 영향)

  • Oh, Sae-Kyoo;Kim, Yeon-Ho;Lee, Sang-Guk;Lee, Jong-Du
    • Journal of Ocean Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.638-638
    • /
    • 1989
  • It has been very important in various industry fields to improve the fatigue strength characteristics of bearings such as bearing life, fatigue limit, etc., because such poor properties could result in shortening the machinery life as well as in decreasing the accuracy. However, no successful heat treatment criterion seems to be available at present. In this study, the effect of the $170^{\circ}C\times120min$ tempering cycles repeated after $380^{\circ}C\times80min$ oil quenching for $800^{\circ}C$ spheroidizing-annealed bearing steel (STB2) as base metal on the $120^{\circ}C$ high temperature rotary bending fatigue strength characteristics were investigated, including the effects on hardness, Charpy impact value and micro-structure, in order to seek for the best heat treatment condition finally. The important results obtained are as follows : 1) The optimal cycle of tempering so that the fatigue strength .sigma. could become the highest was the 4th cycle. And it is confirmed that this $\sigma_{F}$ is about 6 times more increased than that of base metal, and about 1.3 times more increased than the case of the 1 cycle tempered. 2) As a result of the investigation for the effects of tempering cycles on hardness, the hardness at the tempering number of 2 thru 5 cyles was not decreased severely ; only about 10% decrease from those of the quenched and 1 cycle tempered case. Such hardness is equivalent to $H_{R}$/C61-62 with no bad effect on anti-abrasion of bearing steel. 3) In the case of 2 thru 5 cycle tempering as well as 1 cycle tempering, the impact value was not so improved comparing with the case of quenching, but an increase of 5 to 10% could be expected at least. 4) It was experimentally confirmed that the control of the mechanical properties improvement such as fatigue strength and fatigue life for bearing steels could be possible by the number of tempering cycles.

Changes in ginsenoside compositions and antioxidant activities of hydroponic-cultured ginseng roots and leaves with heating temperature

  • Hwang, Cho Rong;Lee, Sang Hoon;Jang, Gwi Yeong;Hwang, In Guk;Kim, Hyun Young;Woo, Koan Sik;Lee, Junsoo;Jeong, Heon Sang
    • Journal of Ginseng Research
    • /
    • v.38 no.3
    • /
    • pp.180-186
    • /
    • 2014
  • Background: This study evaluated changes in ginsenoside compositions and antioxidant activities in hydroponic-cultured ginseng roots (HGR) and leaves (HGL) with heating temperature. Methods: Heat treatment was performed at temperatures of $90^{\circ}C$, $110^{\circ}C$, $130^{\circ}C$, and $150^{\circ}C$ for 2 hours Results: The ginsenoside content varied significantly with heating temperature. The levels of ginsenosides Rg1 and Re in HGR decreased with increasing heating temperature. Ginsenosides F2, F4, Rk3, Rh4, Rg3 (S form), Rg3 (R form), Rk1, and Rg5, which were absent in the raw ginseng, were formed after heat treatment. The levels of ginsenosides Rg1, Re, Rf, and Rb1 in HGL decreased with increasing heating temperature. Conversely, ginsenosides Rk3, Rh4, Rg3 (R form), Rk1, and Rg5 increased with increasing heating temperature. In addition, ginsenoside contents of heated HGL were slightly higher than those of HGR. The highest extraction yield was 14.39% at $130^{\circ}C$, whereas the lowest value was 10.30% at $150^{\circ}C$ After heating, polyphenol contents of HGR and HGL increased from 0.43 mg gallic acid equivalent/g (mg GAE eq/g) and 0.74 mg GAE eq/g to 6.16 mg GAE eq/g and 2.86 mg GAE eq/g, respectively. Conclusion: Antioxidant activities of HGR and HGL, measured by 1,1-diphenyl-2-picrylhydrazyl and 2,2-azino-bis-3-ethylbenzothiazoline-6-sulfonic acid radical scavenging ability, increased with increasing heating temperature. These results may aid in improving the biological activity and quality of ginseng subjected to heat treatments.

Evaluation of Deformation Capacity of Various Steel Springs Subjected to Tensile Loading or Uniaxial Cyclic Loading (인장하중 및 반복하중을 받는 강재 스프링의 변형 성능 평가)

  • Kwon, Hee-Yong;Hwang, Seung-Hyeon;Yang, Keun-Hyeok;Kim, Sanghee;Choi, Yong-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.4
    • /
    • pp.1-10
    • /
    • 2022
  • In this study, to evaluate the possibility of using a steel spring as a displacement-dependent damping device, tensile loading and cyclic loading tests were performed. The main experimental variables were the type of steel (SAE9254 and SS275), the spring constant (700 N/mm, 1,000 N/mm, and 1,400 N/mm), and the presence or absence of heat treatment for SAE9254. As a result of the tensile test, the ratios of the measured spring constant to the design spring constant of the steel springs made with SAE9254 ranged from 1.08 to 1.13, while the ratios of the design spring constant and the measured spring constant of the steel springs made with SS275 ranged from 0.86 to 0.97. After yielding, the slope values of the load-displacement curve of the SAE9254 with/without heat treatment were about 240~251 N/mm and 92 N/mm, respectively, but the slope values of the load-displacement response of SS275 were almost zero. According to the uniaxial cyclic loading test results, all specimens were satisfied with three conditions for a displacement-dependent damping device in KDS 41 17 00 (2019): the maximum force and minimum force at zero displacement, the maximum force and minimum force at the maximum displacement, and the energy dissipation capacity. In addition, the equivalent damping ratios of steel springs made with SAE9254(non-heat treatment) and SS275 were approximately 2.8 times and 1.9 times greater, respectively, than that of steel springs made with SAE9254.

Analysis of The Human Thermal Environment in Jeju's Public Parking Lots in Summer and Suggestion for Its Modification (제주시 공영 주차장 내 여름철 인간 열환경 분석 및 저감 방안 제안)

  • Choi, Yuri;Park, Sookuk
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.52 no.3
    • /
    • pp.18-32
    • /
    • 2024
  • This study aims to analyze the summer human thermal environment in Jeju City's outdoor parking lots by measuring microclimate data and comparing pavement and vegetation albedoes and elements through computer simulations. In measured cases, results due to albedo showed no significance, but there was a significant difference between sunny and shaded areas by trees. The sunny area had a PET (physiological equivalent temperature) in the 'very hot' level, while the shaded area exhibited a 2-step lower 'warm' level. UTCI (universal thermal climate index) also showed that the sunny area was in the 'very strong heat stress' level, whereas the shaded area was 1-step lower in the 'strong heat stress' level, confirming the role of trees in reducing incoming solar radiant energy. Simulation results, using the measured albedoes, closely resembled the measured results. Regarding vegetation, scenarios with a wide canopy, high leaf density, and narrow planting spacing were effective in mitigating the human thermal environment, and the differences due to tree height varied across scenarios. The scenario with the lowest PET value was H9W9L3D8 (tree height 9m, canopy width 9m, leaf area index 3.0, planting spacing 8m), indicating a 0.7-step decrease compared to the current landscaping scenario. Thus, it was confirmed that, among landscaping elements, trees have a significant impact on the summer human thermal environment compared to ground pavement.

The study on DC-link Film Capacitor in 3 Phase Inverter System for the Consideration of Frequency Response (3상 인버터 시스템에서 주파수 특성을 고려한 필름 콘덴서의 DC-link 적용 방법에 관한 연구)

  • Park, Hyun-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.117-122
    • /
    • 2018
  • A large-capacity three-phase system air conditioner recently includes an inverter circuit to reduce power consumption. The inverter circuit uses a DC voltage that comes from DC-link power capacitor with the function of rectifying, which means AC voltage to DC voltage using a diode. An electrolytic capacitor is generally used to satisfy the voltage ripple and current ripple conditions of a DC-link power capacitor used for rectifying. Reducing the capacitance of the capacitor decreases the size, weight, and cost of the circuit. This paper proposes an algorithm to reduce the input ripple current by combining the minimum point estimation phase locked loop (PLL) phase control and the average voltage d axis current control technique. When this algorithm was used, the input ripple current decreased by almost 90%. The current ripple of the DC-link capacitor decreased due to the decrease in input ripple current. The capacitor capacity can be reduced but the electrolytic capacitor has a heat generation problem and life-time limitations because of its large equivalent series resistance (ESR). This paper proposes a method to select a film capacitor considering the current ripple at DC-link stage instead of an electrolytic capacitor. The capacitance was selected considering the voltage limitation, RMS (Root Mean Square) current capacity, and RMS current frequency analysis. A $1680{\mu}F$ electrolytic capacitor can be reduced to a $20{\mu}F$ film capacitor, which has the benefit of size, weight and cost. These results were verified by motor operation.

Simulation of Spatio-Temporal Distributions of Winter Soil Temperature Taking Account of Snow-melting and Soil Freezing-Thawing Processes (융설과 토양의 동결-융해 과정을 고려한 겨울철 토양온도의 시공간 분포 모의)

  • Kwon, Yonghwan;Koo, Bhon K.
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.10
    • /
    • pp.945-958
    • /
    • 2014
  • Soil temperature is one of the most important environmental factors that govern hydrological and biogeochemical processes related to diffuse pollution. In this study, considering the snowmelting and the soil freezing-thawing processes, a set of computer codes to estimate winter soil temperature has been developed for CAMEL (Chemicals, Agricultural Management and Erosion Losses), a distributed watershed model. The model was calibrated and validated against the field measurements for three months at 4 sites across the study catchment in a rural area of Yeoju, Korea. The degree of agreement between the simulated and the observed soil temperature is good for the soil surface ($R^2$ 0.71~0.95, RMSE $0.89{\sim}1.49^{\circ}C$). As for the subsurface soils, however, the simulation results are not as good as for the soil surface ($R^2$ 0.51~0.97, RMSE $0.51{\sim}5.08^{\circ}C$) which is considered resulting from vertically-homogeneous soil textures assumed in the model. The model well simulates the blanket effect of snowpack and the latent heat flux in the soil freezing-thawing processes. Although there is some discrepancy between the simulated and the observed soil temperature due to limitations of the model structure and the lack of data, the model reasonably well simulates the temporal and spatial distributions of the soil temperature and the snow water equivalent in accordance with the land uses and the topography of the study catchment.

A Study on the Probability of BLEVE of Above-ground LP Gas Storage Tanks Exposed to External Fire (지상식 LPG 저장탱크의 외부화재에 의한 BLEVE 가능성 해석)

  • Lee Seung-Lim;Lee Young-Soon
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.1 s.18
    • /
    • pp.19-23
    • /
    • 2003
  • The purpose of this thesis is to investigate the BLEVE probability of LP gas storage tanks which are relatively more dangerous, by the deductive calculating method using the results of Birk's pilot tank test and the required heat capacity of BLEVE. The result that BLEVEs can occur in only above 43.68 percent of liquid filling level under $600^{\circ}C$ of tank pate temperature and $53^{\circ}C$ of inner liquid temperature, was obtained and will be useful for preventing the BLEVE of LP gas storage tanks in fire sites. In addition, this research showed conditions of external leak and fire causing BLEVE, based on 15ton capacity of LP gas tank which has the same specifications as those in Puchon LP gas filling station accident. The result of the calculation is that the minimum pool fire conditions of BLEVE are above 7.2mm equivalent diameter under a liquid release condition and above 17.6mm equivalent diameter under a two-phase release condition. In the end, the result of calculating the pool size corresponding the above conditions using EFFECTS version 2.1, concludes that a minimum of 3.3 meters of diameter and 10.4 meters of height should be needed for BLEVE outbreak.

  • PDF