Clinical Study of Prosthetic Heart Valve Replacement with CarboMedics. (CarboMEdics 기계판막을 이용한 심장판막 치환술의 임상 연구)

  • 장원기;구자홍;조중구;김공수
    • Journal of Chest Surgery
    • /
    • v.33 no.1
    • /
    • pp.45-50
    • /
    • 2000
  • Background: The CarboMedics prosthetic heart valve was produced in an attempt to improve the existing valve designs and was especially concerned with easily the implantation and further reduction of turbulence. Precise positioning of the valve in situ was achieved by the abilityof the valve to rotate relative to the sewing ring. Improved monitoring is possible due to increased radiopacity and the dacron sewing ring is coated with carbon to reduce pannus overgrowth. The leaflets have an opening angle of 78 degrees that apparently allows a rapid synchronous closure The aim of this study was to analyze the clinical performance of the CarboMedics valve prostheses(45 mitral 13 aortic and 7 double aortic-mitral valve replacement) were implanted in 65 patients(mean age 48.75$\pm$9.74 years) Result: The operative mortality was 3.1%(2/65) causes of death were low cardiac output syndrome. Total follow up was 1831 patient-months and mean follow up was 29.06$\pm$10.97 months/patient. No structural failure hemorrhage valve thrombosis and late death have been observed. Embolism occurred at a rate of 0.65%/Patient-year. Actuarial survival and thrombo-mbolism free rate at 36 months were 96.9% and 98.4% respectively. Consclusions: The CarboMedics valve stands for low valve related complicatons.

  • PDF

Changes of Microembolic Signals after Heart Valve Surgery (심장 판막 수술 후 미세색전의 변화)

  • 조수진;이은일;백만종;오삼세;나찬영
    • Journal of Chest Surgery
    • /
    • v.36 no.5
    • /
    • pp.316-320
    • /
    • 2003
  • Background: The detection of circulating microemboli by transcranial Doppler ultrasonography (TCD) has the potential to select the patients with high risk for future symptomatic brain embolism. We prospectively evaluated the positive rate and the frequency of microembolic signals (MES) before and after the heart valve surgery (HVS). Material and Method: Fifty in-patients with heart valve disease were enrolled in this study. Patients with history of previous stroke or heart valve surgery were excluded. Two unilateral TCD monitoring sessions were peformed from middle cerebral artery for 1-hour, before and after HVS. Result: Mechanical Heart valves were implanted in 28 patients, tissue valves were implanted in 10 patients, and remaining 12 patients received mitral valve repair. Positive rate of MES was significantly increased after HVS (50%), compared to that of before HVS (8%, p=0.00). There was no relation between MES after HVS and intensity of anticoagulation, cardiac rhythm, patients' age, and history of hypertension. The positive rate of MES after implantation of mechanical heart valve (71.4%) was significantly higher than those after implantation of tissue valve or mitral valve plasty (p=0.002). Conclusion: Positive rate of MES was increased significantly after the implantation of HVS. The changes of MES in those with mechanical prosthesis may be related to the increased risk or embolism after Hvs.

Aortic valve replacement in the patient with rheumatic heart disease (류마치스성 심장질환 환자에서 대동맥판막치환)

  • An, Jae-Ho;Lee, Yeong-Gyun
    • Journal of Chest Surgery
    • /
    • v.17 no.3
    • /
    • pp.346-355
    • /
    • 1984
  • 77 cases of Aortic Valve Replacement, which were composed of 64 rheumatic valvular heart disease and 13 combined congenital heart disease, were operated at Seoul National University Hospital for Aortic valvular disease during the period from June 1968 to December 1983. Among these 64 rheumatic aortic valvular heart disease cases, 8 patients were expired during and immediate after operation and overall mortality rate was 12.5%. For more precise remarks, these patients were divided into two periodic groups, 1st period [from 1968 to 1976] and 2nd [from 1977 to 1983] when annual open heart surgery were over 100 cases, and in 1st period three of four patients were died and in 2nd period five of sixty patients were died and its mortality rate was 8.3%. There were 12 cases of postoperative complication, which were 3 cases of remaining other valvular heart disease required MVR, 2 paravalvular leaks [one of them got Redo AVR], 4 thromboembolism or problem of anticoagulant therapy, 2 late death due to SBE with replaced valve failure and one functional AS with small sized valve. Operative death was affected by pump-time and aortic cross-clamping time, heart size, Ejection Fraction, LVEDP and symptom duration, and other many factors may influence the survival rate. Improved operative technique and myocardial protection and meticulous evaluation of the preoperative patient status will make the AVR safer.

  • PDF

Short and Intermediate Term Results of the ATS Heart Valve Replacement (ATS 인공 심장 판막의 단기 및 중기 임상성적)

  • Lim, Chang-Young;Moon, Seung-Chul;Yang, Jin-Young;Koo, Won-Mo;Kim, Dae-Sig;Lee, Gun;Lee, Hyeon-Jae
    • Journal of Chest Surgery
    • /
    • v.32 no.11
    • /
    • pp.1031-1035
    • /
    • 1999
  • Background: ATS mechanical valve is a recently introduced pyrolytic carbon bileaflet prosthesis. This report is to evaluate the results of hemodynamic and anticoagulant therapy after ATS valve replacement. Material and Method: From May 1995 to October 1998, 53 patients received 65 ATS prosthesis; 38 Mitral(27-33 mm), 27 Aortic(19-25 mm). 2 CABGs and 5 Tricuspid annuloplasty were taken concomitantly. The follow up period was 769 patient-months(mean 16.2$\pm$10.0), varied from 1 month to 39 months with 92.5% follow up rate. All patients were evaluated with Doppler echocardiography, 7-14 days after operation. Result: NYHA functional class was improved significantly, from 2.6$\pm$0.8 preoperatively to 1.3$\pm$0.4 postoperatively. The average value of peak and mean transvalvular pressure gradients were 25.7$\pm$13.5 mmHg, 12.7$\pm$8.3 mmHg in aortic position. In the mitral position, the average values of peak and mean transvalvular pressure gradient and valve area were 5.9$\pm$2.5 mmHg, 3.1$\pm$0.8 mmHg and 2.9$\pm$0.5 $\textrm{cm}^2$, respectively. In the anticoagulant therapy, mean INR was 2.5$\pm$0.6 in mitral valve replacement and 1.9$\pm$0.5 in aortic valve replacement. There was no anticoagulant related complication. During that period, there were 3 hospital death(5.9%) and 1 late death(1.9%). Conclusion: The early clinical results of the ATS heart valve replacement is quite satisfactory, and low target INR reginmen is safe. And long term follow of hemodynamic characteristics is also necessary.

  • PDF

Congenital Quadricuspid Aortic Valve (선천성 사엽성 대동맥판막)

  • Na Chan-Young;Oh Sam-Sae;Whang Seong Wook;Lee Cheul;Kim Jae Hyun;Seo Hong Ju;Baek Man-Jong
    • Journal of Chest Surgery
    • /
    • v.38 no.2 s.247
    • /
    • pp.164-167
    • /
    • 2005
  • Quadricuspid aortic valve is a rare congenital abnormality but it is well recognized as the cause of significant aortic regurgitation. We describe 5 patients who underwent surgery for severe aortic regurgitation associated with quadricuspid valve. In all patients, this abnormality had been incidentally detected during surgery. Two of the patients had infective endocarditis. In accordance with the Hurwitz and Roberts classification, two valves were type d, two were type a, and one was type c.

A Numerical Study on the Blood Flow through a Disc Type Heart Valve (원판형 심장판 주위의 혈액 흐름에 대한 수직 해석)

  • 박영필;이신재
    • Journal of Biomedical Engineering Research
    • /
    • v.2 no.2
    • /
    • pp.89-102
    • /
    • 1981
  • The recirculating flows which occur in the prosthetic heart valve have been known to cause several diseases in the human body. And the recent studies show that the shear stress at the wall of the artery is also very important factor in the formation of thrombus. And many studies knave been devoted in obtaining more information about the blood flow through the prosthetic heart valve. In this Paper, the steady axisymmetric flow through the Disc-Type Heart Valve is studied by using the numerical method. The geometry of the Disc-Type Heart Valve is simplified, and the flow is assumed to be steady axisymmetric flow. The vorticity transport equation derived from the Wavier-Stoke's equation is used as the governing equation, and the explicit finite difference method is used to obtain the steady state solution. The results for several Reynolds numbers show that the recirculating flow becomes large as the Remolds number increases. Furthermore, it can be shown that the magnitudes of the vorticity and the stresses are also increased with the Reynolds number, but there is only a little change in their configurations of distribution and in their positions of maximum values.

  • PDF

Classificatin of Normal and Abnormal Heart Sounds Using Neural Network (뉴럴네트워크를 이용한 심음의 정상 비정상 분류)

  • Yoon, Hee-jin
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.5
    • /
    • pp.131-135
    • /
    • 2018
  • The heart disease taking the second place of the cause of the death of modern people is a terrible disease that makes sudden death without noticing. To judge the aortic valve disease of heart diseases a name of disease was diagnosed using psychological data provided from physioNet. Aortic valve is a valve of the area that blood is spilled from left ventricle to aorta. Aortic stenosis of heart troubles is a disease when the valve does not open appropriately in contracting the left ventricle to aorta due to narrowed aortic valve. In this paper, 3126 samples of cardiac sound data were used as an experiment data composed of 180 characteristics including normal people and aortic valve stenosis patients. To diagnose normal and aortic valve stenosis patients, NEWFM was utilized. By using an average method of weight as an feature selection method of NEWFM, the result shows 91.0871% accuracy.

Clinical Experiences of Open Heart Surgery [50 Cases] (개심술 치험 50례)

  • 임진수
    • Journal of Chest Surgery
    • /
    • v.18 no.4
    • /
    • pp.692-699
    • /
    • 1985
  • Fifty cases of Open Heart Surgery due to congenital and acquired heart disease were done using the cardiopulmonary bypass in the Department of Thoracic and Cardiovascular surgery, Chosun University Hospital from November, 1980 to June, 1985. 1. The age of the congenital heart disease was from 7 to 29 years, the mean age was 14.5 years. In the acquired heart disease, the age was from 14 to 48 years, and the mean age was 22.3 years. The ratio of male to female was about 1.8:1. 2. The number of congenital cyanotic heart disease were 7 patients, congenital acyanotic heart disease were 17 patients and acquired valvular heart disease were 26 patients. All of the acquired heart disease was one or more valve disease. 3. Preoperative symptoms of the congenital heart disease were exertional dyspnea [cyanotic 100%, acyanotic 70.6%] and palpitation [cyanotic 28.6%, acyanotic 76.1%], and the acquired heart diseases were exertional dyspnea [92.3%], palpitation [34.1 %], and chest discomfort [30.8%]. 4. The method of the myocardial protection during the cardiopulmonary bypass were mild or moderate hypothermia, intermittent coronary perfusion of the cardioplegic solution, topical myocardial hypothermia with 4oC Hartmann`s solution. 5. In the cases of the valve replacement, postoperative oral anticoagulant therapy was started at oral intake of food using the warfarin and persantin, and the prothrombin time was maintained 30-50% of control value during 3-6 months for tissue valve replacement and permanently for metal valve replacement. 6. The postoperative complications were appeared in 24 cases and the complications were wound infection, occipital alopecia, hemorrhage etc. 7. The mortality after open heart surgery was 8 percents and the cause of death was low cardiac output syndrome, right heart failure, DIC, and Left ventricle rupture.

  • PDF

Physical Analysis of the Prosthetic Valve Sound (기계판막치환후의 판막음에 대한 연구)

  • 조범구
    • Journal of Chest Surgery
    • /
    • v.22 no.4
    • /
    • pp.589-593
    • /
    • 1989
  • The frequency spectrum of the metallic closing sound and its loudness were measured by non invasive techniques in 66 patients. They had examined a total of 7 Carbomedics valve, 10 Duromedics valve, 11 St. Jude heart valve in mitral position and 8 Carbomedics, 10 Duromedics, 20 St. Jude heart valve prostheses functioning normally in aortic position. Statistical comparison of the loudness from sound produced by the three valves in each position, the following; The Carbomedics valve has the lowest average loudness, followed by the St. Jude medical valve, and finally the Edward Duromedics valve. And we analysis the changing factor of the loudness of valve sound, only the velocity of the flow through the valve influenced to the valve sound.

  • PDF

Unilateral vocal cord paralysis after open heart surgery -A report of 2 cases- (개심술후 발생한 일측성 성대마비 -2례 보고-)

  • 이종욱
    • Journal of Chest Surgery
    • /
    • v.23 no.3
    • /
    • pp.522-526
    • /
    • 1990
  • We have experienced 2 cases vocal cord paralysis after open heart surgery. One was a postoperatively developed right unilateral vocal cord paralysis after prosthetic mitral valve replacement with tricuspid valve annuloplasty. The other was a postoperative left unilateral vocal cord paralysis after prosthetic aortic and mitral valve replacement with tricuspid annuloplasty. They were intubated for forty-eight and seventy-two hours but after extubation complained of hoarseness, aphonia, anxiety, and ineffective coughing Indirect laryngoscopy performed at about postoperative one week, revealed partial paralysis and decreased mobility of the vocal cord. After active phonation therapy, symptoms were improved gradually and in the follow up indirect laryngoscopy, the vocal cord paralysis was improved. The symptoms were recovered completely at about postoperative one month in both. The cause of vocal cord paralysis after open heart surgery may be any retraction or stretching injury to the recurrent laryngeal nerve, especially right side, during median sternotomy retraction and open heart operation procedures. As a result, avoid of excessive spread of median sternotomy retractor and excessive manipulation and retraction of the heart during open heart procedures will reduce the occurrence of the vocal cord paralysis.

  • PDF