• 제목/요약/키워드: heart sound

검색결과 147건 처리시간 0.022초

The study of the change of life with Kim's Ajaeng Sanjo Music Playing (ASMP) played by Hyung Min Kim (https://youtu.be/GTfOIJ7bZbo)

  • Ko, Kyung Ja
    • 셀메드
    • /
    • 제8권2호
    • /
    • pp.9.1-9.3
    • /
    • 2018
  • The purpose of this article is to discuss that ajaeng sanjo music playing (ASMP) can change a person's life. Ajaeng is often called a Korean cello and is the largest and lowest-pitched instrument in the string instrument family in Korean music. From far away it has a deep, low sound. Its low sound adds to its comfort and peace. Listening to a low tone music can help you calm down and heart-easing. As soon as he listened ajaeng sanjo music he felt that low sound is mildly under his patronage. He felt much more interesting energy and vitality about our minds and bodies are in ajaeng sanjo music. He could immerse himself in playing ajaeng sanjo music (ASMP) for several years. The Korean music, tune is one of expression, meaning it is inseparable from the feeling. Many studies show that low tone music not only activates brain power, but soothes minds. Music always stood by him during difficult times. In a word, ASMP leads him to change of life and music is the language of emotion to him.

혈전이 발생한 인공판막의 판막음 스펙트럼 분석 (Sound Spectral Analysis of Valvular Clicks of Thrombosed Valve Prostheses)

  • 김상현;장병철;탁계래;허재만;김남현;강면식;조범구
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1994년도 춘계학술대회
    • /
    • pp.105-108
    • /
    • 1994
  • A comparative study was made of the valvular sounds produced by normal prosthetic valves with thrombosed prosthetic valves. Comparisons of the closing sound were made for the power frequency spectra associated with individual valves. We used periodogram approach to obtain the spectral characteristics of the valve. Spectral analysis system was tested in mock circulatory system by comparing normal valves with those produced by the same valves but having simulated thrombosis at the hinge of the valve. The heart sounds was recorded from two patients having normal mechanical valve and thrombosed mechanical valve. The estimated spectrum of the thrombosed mechanical valve displayed lower apparent peak frequency than that of the normal valve. The results showed that frequency spectra gave information pertinent to the valve malfunction. Sound spectral analysis is simple and alternative diagnostic tool for early detection of prosthetic valve mal function.

  • PDF

전전두엽의 비대칭성과 심장박동율변동성에 기초한 음향감성 평가 (Evaluation of Sound-induced Affects based on Prefrontal Cortex Asymmetry and Heart Rate Variability)

  • 김원식;이지혜;조문재
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 2001년도 추계학술대회 논문집
    • /
    • pp.138-143
    • /
    • 2001
  • 본 연구에서는 생환공간에서의 음향감성을 평가하기 위하여 긍정감성을 유발하는 음환경으로서 '명상음악'과 부정감성을 유발하는 음환경으로서 '헬리콥터소음'과 '마루가 삐거덕거리는 소음'을 제시하였을 때 행동활성화체계(BAS)와 행동억제체계(BIS)의 민감성이 서로 다른 집단들을 대상으로 전전두엽의(PFC) 비대칭성과 심장박동율변동성(HRV)을 분석하였다. 연구결과, 명상음악을 청취시에는 안정상태에 비하여 좌측전두엽이 더 활성화되고 HRV의 LF/HF는 감소된 반면에 소음환경에서는 우측전두엽이 더 활성화되고 LF/HF는 더 증가하였다.

  • PDF

Ebstein 심기형 수술 1례[Plication 및 삼첨판막 이식예] (Ebstein`S Anomaly: A Case Report of Plication and Tricuspid Valve Replacement)

  • 송명근
    • Journal of Chest Surgery
    • /
    • 제11권3호
    • /
    • pp.342-347
    • /
    • 1978
  • A 8 year old male was admitted to the Department of Thoracic Surgery, Korea University Hospital on June 22, 1978. The chief complaints were cyanosis and exertional dyspnea since at birth. EKG shows BVH and dextrocardia, phonocardiogram revealed the accentuation of second heart sound in aortic area. Echocardiogram from the left ventricle to the base of the heart, there is a discontinuity between the ventricular septum and the anterior aortic margin with a large aortic root & aortic overriding. His cardiac catheterization data and cardiac angiogram shows situs inversus totalis, dextrocardia, right aortic arch, large ventricular septal defect etc., and finally diagnosed Truncus Arteriosus. Edwards type IV with retrograde aortogram and selective bronchial angiogram. This is the first operative case reported as Rastelli operation for Truncus Arteriosus type IV in the literatures in Korea. Authors have experienced I case of Truncus Arteriosus, Edward type IV and Rastelli operation with Dacron Arterial Conduit Graft under cardiopulmonary bypass on July 3, 1978. The procedures were as follows; 2] Cardiopulmonary bypass: Origin of bronchial arteries excised from descending aorta bilaterally; defects in aorta closed. 2] Horizontal incision made high in right ventricle. 2] Ventricular septal defect [Kirklin type I+II] closed with Teflon patch. 4] Bifurcated dacron arterial graft with pericardial monocusp sutured to the bilateral pulmonary arteries. [Diameter 9 mm: Length 7 cm]. 5] Proximal end of the conduit graft anastomosed to right ventricle. [Diameter 19 mm: Length 5 cm]..Total perfusion time was 220 min. The result of operation was poor due to anastomotic leakage and increased pulmonary vascular resistance resulting acute right heart failure. The patient was died on the operation table. Literatures were briefly reviewed.

  • PDF

총동맥간 잔류증 [IV 형]Rastelli 수술 치험 보고 (Rastelli operation in Persistent Truncus Arteriosus, Type IV: A Case Report)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • 제11권3호
    • /
    • pp.333-341
    • /
    • 1978
  • A 8 year old male was admitted to the Department of Thoracic Surgery, Korea University Hospital on June 22, 1978. The chief complaints were cyanosis and exertional dyspnea since at birth. EKG shows BVH and dextrocardia, phonocardiogram revealed the accentuation of second heart sound in aortic area. Echocardiogram from the left ventricle to the base of the heart, there is a discontinuity between the ventricular septum and the anterior aortic margin with a large aortic root & aortic overriding. His cardiac catheterization data and cardiac angiogram shows situs inversus totalis, dextrocardia, right aortic arch, large ventricular septal defect etc., and finally diagnosed Truncus Arteriosus. Edwards type IV with retrograde aortogram and selective bronchial angiogram. This is the first operative case reported as Rastelli operation for Truncus Arteriosus type IV in the literatures in Korea. Authors have experienced I case of Truncus Arteriosus, Edward type IV and Rastelli operation with Dacron Arterial Conduit Graft under cardiopulmonary bypass on July 3, 1978. The procedures were as follows; 2] Cardiopulmonary bypass: Origin of bronchial arteries excised from descending aorta bilaterally; defects in aorta closed. 2] Horizontal incision made high in right ventricle. 2] Ventricular septal defect [Kirklin type I+II] closed with Teflon patch. 4] Bifurcated dacron arterial graft with pericardial monocusp sutured to the bilateral pulmonary arteries. [Diameter 9 mm: Length 7 cm]. 5] Proximal end of the conduit graft anastomosed to right ventricle. [Diameter 19 mm: Length 5 cm]..Total perfusion time was 220 min. The result of operation was poor due to anastomotic leakage and increased pulmonary vascular resistance resulting acute right heart failure. The patient was died on the operation table. Literatures were briefly reviewed.

  • PDF

일변량 분산 분석과 이변량 시계열 분석을 이용한 미숙아의 목소리 자극에 대한 심박동수와 호흡수 반응의 비교 (Comparison and Analysis of Response of Premature Infants to Auditory Stimulus)

  • 이혜정
    • Child Health Nursing Research
    • /
    • 제15권3호
    • /
    • pp.261-270
    • /
    • 2009
  • Purpose: The purpose of this study was to compare the result of one-way ANOVA with that of cross-correlation time series analysis in order to evaluate physiologic responses of premature infants to human voices. Methods: Four premature infants born prior to 32 weeks gestational age were included in the study. The Gould 4000TA Recording System recorded the preterm infant's heart and respiratory rate while they were listening to a pre-recorded voice recording. Each infant listened to both male and female voices (1 min each) at each testing session. Results: The results of both one-wayANOVA and cross-correlation time series analysis using heart and respiratory rate data were not consistent in some of premature infants. A cross-correlation time series analysis revealed that the responses of premature infant to vocal stimulation occurred at a varying number of seconds after the stimulus was presented and lasted for over 20-30 sec. Conclusion: The results indicate that a time series analysis can provide more detailed information on the rapidly changing physiologic status of premature infant to the auditory stimulus. In addition, the results provide an insight into an auditory responsitivity of premature infants to a naturally occurring sound, the human voice, in the neonatal intensive care unit.

  • PDF

심음 분석을 위한 주파수 특성에 기반한 매칭퍼슈잇 방법 (Matching Pursuit based on Frequency Characteristics of Heart Sounds for Phonocardiogram Analysis)

  • 김일동;정규혁;임종하;이인성
    • 전자공학회논문지SC
    • /
    • 제47권1호
    • /
    • pp.47-55
    • /
    • 2010
  • 심음은 심질환을 진단하는 1차적인 수단이지만 비정상 심음인 S2에서 A2와 P2의 분열 신호와 S2에 S3의 분마음 간섭 신호는 전문 의사들조차 청각적으로 구분하기 쉽지 않아 초기 진단에 어려움이 있다. 본 논문에서는 청각적으로 구분이 어려운 심음들을 분류하기 위해 PCG 신호의 주파수 특성에 적합한 분석 및 합성 방법을 제안한다. 제안한 방법은 심음을 매칭 퍼슈잇으로 분해한 후 주파수 특성에 맞게 대역별로 합성하여 분석함으로써 청진으로 구분이 어려운 신호를 다른 상태의 심음과 구별한다. 실험 결과 분석을 통해 초기 진단 시 불명확한 S2의 분열 유무, S2의 분열 상태, 그리고 S3의 분마음 간섭 신호를 구별할 수 있었으며 분열의 정확한 시간 간격을 확인할 수 있었다.

SVM을 이용하여 HMM과 심잡음 점수를 결합한 심음 기반 심장질환 분류기 (Heart Sound-Based Cardiac Disorder Classifiers Using an SVM to Combine HMM and Murmur Scores)

  • 곽철;권오욱
    • 한국음향학회지
    • /
    • 제30권3호
    • /
    • pp.149-157
    • /
    • 2011
  • 본 논문은 support vector machine (SVM)을 사용하여 은닉 마코프 모델 (HMM)과 심잡음 존재 정보를 결합한 새로운 심장질환 분류 방법을 제안한다. 켑스트럼 특징과 HMM 비터비 (Viterbi) 알고리듬을 이용하여 입력 신호를 모든 심장질환 모델에 대하여 상태 단위로 분할하여 상태별로 로그우도 (점수)를 계산한다. 심잡음 신호의 시간적 위치 특성을 이용하기 위하여 입력신호를 두 개의 부대역으로 나누고 부대역별로 프레임 단위의 심잡음 점수를 계산한 다음, 비터비 알고리듬으로부터 구한 상태 분할 정보를 이용하여 상태단위의 심잡음 점수를 구한다. SVM은 모든 심장질환 종류에 대한 상태 단위의 HMM과 심잡음 점수를 입력으로 하여 최종적으로 심장질환을 판정한다. 심장질환 분류 실험결과, 제안한 방법은 기존의 켑스트럼 특징과 HMM 분류기를 이용한 방법에 비하여 20.4 %의 상대적 개선율을 보여준다.

실시간 심음 전송을 위한 원격 의료상담시스템 (Telemedicine Conference System for Realtime Transfer of Heart Sound)

  • 이병문;조원희;윤영미
    • 한국콘텐츠학회논문지
    • /
    • 제9권8호
    • /
    • pp.158-165
    • /
    • 2009
  • 원격의료에 있어서 의사와의 상담은 매우 중요하다. 그러나 의사가 환자의 상태를 보다 정확히 판단하기 위해서는 최소한의 청진이 필요하다. 최근에 인터넷을 기반으로 화상 상담시스템이 개발되었으나 심장질환의 경우에는 원격으로 심음을 청진할 수 없어 원격의료 상담에 활용할 수 없었다. 이와 같은 문제를 해결하려면 의사와 환자가 상담도중에 심음을 측정하고 이를 실시간으로 전송할 수 있어야 한다. 본 논문에서는 의사가 인터넷을 통해 전송된 심음을 듣고 청진할 수 있는 실시간 심음 전송용 원격의료 화상청진 시스템을 제시하였다. 또한 u-헬스케어 환경에 적합하도록 모니터링 요원을 통해 주치의를 연결시켜줄 수 있도록 기능을 설계하고 구현하였다. 제안된 시스템은 환자와 의사의 이동성을 지원하기 위해 서버에이전트를 두어 사용자 인증과정에서 네트워크 주소정보를 제공하도록 기능구현을 하였다. 본 논문에서 구현한 시스템은 향후 심장질환자의 원격진료에 활용할 수 있을 것이다.

청각자극 증가에 따른 지적장애인의 심박수와 손 기능, 건강관련 삶의 질의 변화 (The Changes of the Heart Rate, Hand Function, and Health related Quality of Life of the People with Intellectual Disability through the Increase of the Auditory Stimulation)

  • 손성민;강진호;박아름
    • 한국엔터테인먼트산업학회논문지
    • /
    • 제14권5호
    • /
    • pp.217-227
    • /
    • 2020
  • 본 연구의 목적은 청각자극 증가에 따른 지적장애인의 심박수, 손 기능과 건강관련 삶의 질의 변화를 분석하는데 있다. 연구대상은 지적장애인 16명이다. 청각자극 중가는 음악의 볼륨을 통해 조절되었고, 60dB, 65dB, 70dB로 자극의 강도를 증가시켜 적용하였다. 청각자극 증가에 따라 Xeno 손목형 심박수와 혈압 측정기(LHY Health, Co., China)를 활용하여 심박수를 측정하였다. 손 기능의 측정은 퍼듀 페그보드를 활용하여 손 기능을 측정하였다. 건강관련 삶의 질은 Short-form 8 health survey를 활용하여 평가하였다. 연구결과 청각자극 증가에 따라 심박수가 지속적으로 증가하였으며, 손 기능도 지속적으로 감소하였다. 건강관련 살의 질은 청각자극 적용 후 감소하였다. 이에 청각자극 증가에 따른 심막수와 손 기능, 건강관련 삶의 질의 변화가 나타났다. 본 연구결과에 의하여, 청각자극 증가는 지적장애인의 심리적 불편감으로 작용하게 되어 심박수를 증가시키며, 손 기능과 건강관련 삶의 질을 감소시키는 데 작용하게 된다. 따라서 지적장애인의 심박수의 감소와 손 기능, 건강관련 삶의 질의 향상을 위해 환경자극에서 청각자극 강도를 고려해야 할 것이다.