• Title/Summary/Keyword: heart rate signal

Search Result 230, Processing Time 0.024 seconds

Peak Detection of Pulse Wave Based on Fuzzy Inference and Multi Sub-Band Filters for U-Healthcare (U-헬스케어를 위한 퍼지추론과 다중 하위대역 필터를 기반한 맥파 최대치 검출)

  • Lee, Ju-Won;Lee, Byeong-Ro
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.12
    • /
    • pp.2159-2164
    • /
    • 2008
  • Ubiquitous healthcare system is system that monitors and manages user's health information, and most important in the healthcare system is accuracy of the measured health data. But, the accuracy changes remarkably according to user's motion artifacts in real life. To elevate accuracy of health data, we proposed new algorithm to detect maximum point of pulse wave for heart rate extraction. and the proposed algorithm is to detect maximum points detect of pulse wave in photo-plethysmography signal included motion artifacts by fuzzy inference and multi sub-band filters. In results of experiment to evaluate the performance of the proposed algorithm, we could verify the proposed algorithm extracted maximum point of pulse wave in complex motion artifacts.

An adaptive pulse measurement mechanism using ECG sensor node based on Zigbee (지그비 기반의 심전도 센서노드를 사용한 적응형 심박탐지 모델)

  • Lee, Byung-Mun;Park, Yeon-Hee;Lee, Young-Ho
    • Journal of Internet Computing and Services
    • /
    • v.10 no.3
    • /
    • pp.27-33
    • /
    • 2009
  • With the upcoming u-healthcare era, a way of measurement for vital sign monitoring of cardiac patients is changing as well. In existing measurement of cardiac patients, various wire in ECG measuring equipment has caused much discomfort and inconvenience. In order to decrease the problem, we are developing an efficient measurement of ECG signal using Wireless sensor network. In this paper, we present a way to reduce amount of data by transmitting ECG data collected from radio electrocardiogram sensor based on Zigbee after calculating cardiac rate. And in order to control the error which can be caused by the different ECG signal intensity each individual can has, we also suggest an adaptive pulse measurement model which can measure heart rate with correcting according to different ECG intensity. To verify the suggested model, sensor application was developed and the data was acquired in TinyOS 2.0 environment and the adaptive pulse measurement model was evaluated through the data from the experiments.

  • PDF

A Research on the Development of Smartwatch and Wind Speed System for Marine Leisure (해양레저용 스마트워치 및 풍향풍속계 개발에 관한 연구)

  • Ha, Yeon-Chul;Park, Jae-Mun;Lee, In-Seong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.1
    • /
    • pp.20-29
    • /
    • 2021
  • This study developed a smartwatch and a wind speed system in accordance with the necessity of a device that provides the information required in marine leisure. Based on a marine leisure smartwatch with a multi-sensor, a gyro box, and a wind speed system, external data such as GPS, motion, humidity, temperature, air pressure, and heart rate can be collected. In addition, the collected external environment data can be managed through an application on a smartphone, which is an Android-based mobile device. The developed smartwatch and wind speed system are expected to contribute to increasing accessibility and revitalization of the marine leisure industry. In addition, in terms of safety and education, the need for a device that provides marine information is large, so it is expected to increase the possibility of entering the high value-added market and improve the product localization rate.

Development of an Eye Patch-Type Biosignal Measuring Device to Measure Sleep Quality (수면의 질을 측정하기 위한 안대형 생체신호 측정기기 개발)

  • Changsun Ahn;Jaekwan Lim;Bongsu Jung;Youngjoo Kim
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.12 no.5
    • /
    • pp.171-180
    • /
    • 2023
  • The three major sleep disorders in Korea are snoring, sleep apnea, and insomnia. Lack of sleep is the root of all diseases. Some of the most serious potential problems associated with sleep deprivation are cardiovascular problems, cognitive impairment, obesity, diabetes, colitis, prostate cancer, etc. To solve these problems, the Korean government provided low-cost national health insurance benefits for polysomnography tests in July 2018. However, insomnia patients still have problems getting treated in terms of time, space, and economic perspectives. Therefore, it would be better for insomnia patients to be allowed to test at home. The measuring device can measure six biosignals (eye movement, tossing and turning, body temperature, oxygen saturation, heart rate, and audio). A gyroscope sensor (MPU9250, InvenSense, USA) was used for eye movement, tossing, and turning. The input range of the sensor was in 258°/sec to 460°/sec, and the data range was in the input range. Body temperature, oxygen saturation range, and heart rate were measured by a sensor (MAX30102, Analog Devices, USA). The body temperature was measured in 30 ℃ to 45 ℃, and the oxygen saturation range was 0% for the unused state and 20 % to 90 % for the used state. The heart rate measurement range was in 40 bpm to 180 bpm. The measurement of audio signal was performed by an audio sensor (AMM2742-T-R, PUIaudio, USA). The was -42 dB ±1 dB frequency range was 20 Hz to 20 kHz. The measured data was successfully received in wireless network conditions. The system configuration was consisted of a PC and a mobile app for bio-signal measurement and data collection. The measured data was collected by mobile phones and desktops. The data collected can be used as preliminary data to determine the stage of sleep and perform the screening function for sleep induction and sleep disturbances. In the future, this convenient sleep measurement device could be beneficial for treating insomnia.

Real Time ECG Derived Respiratory Extraction from Heart Rate for Single Lead ECG Measurement using Conductive Textile Electrode (전도성 직물을 이용한 단일 리드 심전도 측정 및 실시간 심전도 유도 호흡 추출 방법에 관한 연구)

  • Yi, Kye-Hyoung;Park, Sung-Bin;Yoon, Hyoung-Ro
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.7
    • /
    • pp.335-343
    • /
    • 2006
  • We have designed the system that measure one channel ECG by two electrode and extract real-time EDR with more related resipiration and comportable to subject by using conductive textile. On the assumption that relation between RL electrode and potential measurement electrode is coupled with RC connected model, we designed RL drive output to feedback two electrode for reduction of common mode signal. The conductive textile which was used for two ECG electrode was offered more comfort during night sleep in bed than any other method using attachments. In the method of single-lead EDR, R wave point or QRS interval area could be used for EDR estimation in traditional method, it is, so to speak, the amplitude modulation(AM) method for EDR. Alternatively, R-R interval could be used for frequency modulation(FM) method based on Respiratory Sinus Arrhythmia(RSA). For evaluation of performance on AM EDR and FM EDR from 14 subject, ECG lead III was measured. Each EDR was compared with both temperature around nose(direct measurement of respiration) and respiration signal from thoracic belt(indirect measurement of respiration) on mean squared error(MSE), cross correlation(Xcorr), and Coherence. The upsampling interpolation technique of multirate signal processing is applied to interpolating data instead of cubic spline interpolation. As a result, we showed the real-time EDR extraction processing to be implemented at micro-controller.

An Implementation of Wireless Monitoring System for Health Care (헬스 케어를 위한 무선 모니터링 시스템 구현)

  • Eom, Sang-Hee;Nam, Jae-Hyun;Chang, Yong-Hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.67-71
    • /
    • 2007
  • Recently, a health care need according to the increase of an advanced age population is increasing. The requirement about a health care monitoring is increasing rapidly from general people as well as patient. The requisition about a medical treatment technique and a medical treatment information service is the trend to be expanding. That can be possible minimizing the inconvenience of the patient to take a medical service and continuously monitoring the status of the patient to take a health care service. This paper discusses an implementation of wireless physiological signal monitoring system for health care. The system are composed of the sensor node and monitoring program. The sensor node has the physiological signal measurement part and the wireless communication part. The remote monitoring system has a monitoring program that are communicating the sensor node using bluetooth. The sensor node measured the ECG, pulse wave, blood pressure, Sp02, and heart rate.

  • PDF

Study on Electrically Powered Left Ventricular Circulation Assist Device (좌심실 전동순환 보조장치에 관한 연구)

  • Kim, Myoung-Nam;Lee, Jeong-Woo;Chang, Bong-Hyun;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.51-60
    • /
    • 2000
  • This paper outlines the development of a non-pulsatile axial flow type blood pump control system. By utilizing blood pressure and heart rate, this system can assist the left ventricle in controlling blood pressure and blood volume. The system is comprised of a blood pump, signal sensor, signal interface, and signal-processing component. A control algorithm is also proposed which can control non-pulsatile, continuous blood flow in the human circulatory system. To facilitate the control required for non-pulsatile blood pump in a physiological system, an experimental control rule was developed utilizing ECG and blood pressure data, both of which are easily detectable variables in the body. The system was then tested using a mock-up circulation system and we found that it is possible that this systems could be temporarily used in clinic.

  • PDF

An Implementation of Wireless Monitoring System for Health Care (헬스 케어를 위한 무선 모니터링 시스템 구현)

  • Eom, Sang-Hee;Chang, Yong-Hoon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.8
    • /
    • pp.1401-1407
    • /
    • 2008
  • Recently, a health care need according to the increase of an advanced age population is increasing. The requirement about a health care monitoring is increasing rapidly from general people as well as patient. The requisition about a medical treatment technique and a medical treatment information service is the trend to be expanding. That can be possible minimizing the inconvenience of the patient to take a medical service and continuously monitoring the status of the patient to take a health care service. This paper discusses an implementation of wireless physiological signal monitoring system for health care. The system are composed of the sensor node and monitoring program. The sensor node has the physiological signal measurement part and the wireless communication part. The remote monitoring system has a monitoring program that are communicating the sensor node using bluetooth. The sensor node measured the ECG, pulse wave, blood pressure, SpO2, and heart rate.

The Development of the Smart Sensibility Mat with Kangaroo Mother Care (캥거루 케어를 반영한 스마트 감성 매트의 개발)

  • Cho, Soo-Min
    • Science of Emotion and Sensibility
    • /
    • v.20 no.2
    • /
    • pp.171-178
    • /
    • 2017
  • 'Smart Sensibility Mat (SSM)' was developed and manufactured for positive sensibility of newborn with fiber, digital, and sensibility technology to reflect features and advantages of kangaroo care. For tactile stimuli, the tube of the silicon material to provide a constant temperature of $32^{\circ}C$ was inserted into the mat and connected to the water-thermostat. To provide a uniform temperature throughout the mat, the fabric by the inserting conductive yarn was attached to the mat surface. After wrapping the mat with cotton pad, the polyurethane foam used as medicine in order to similar to the human skin was bonded to the surface of the mat. To provide the auditory stimuli of a level of 30dB with mother's heartbeat sounds and voice recorded in advance, the Bluetooth speaker was inserted into the mat. To investigate the effects of SSM, 10 newborns who born within two weeks were involved in this experiment. While the baby was lying on each of the general mat (GM) and SSM, the baby's physiological signals-heart rate, breathing rate, temperature- were measured and then, those were conducted t-test to examine the difference between the signals of SSM and GM. The results were as follows: heart rate (t=8.131, p<.001) and respiratory rate (t=7.227, p<.001) among the physiological signals of SSM decreased significantly than GM within the normal range. Temperature (t=1.062, p=0.292) at SSM showed a tendency to decrease than GM within the normal range. This means the tactile stimuli and the auditory stimuli providing from SSM give stable physiological responses. Thus, SSM leads to have psychological comfort and stability of newborns.

Arrhythmia Classification using GAN-based Over-Sampling Method and Combination Model of CNN-BLSTM (GAN 오버샘플링 기법과 CNN-BLSTM 결합 모델을 이용한 부정맥 분류)

  • Cho, Ik-Sung;Kwon, Hyeog-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.10
    • /
    • pp.1490-1499
    • /
    • 2022
  • Arrhythmia is a condition in which the heart has an irregular rhythm or abnormal heart rate, early diagnosis and management is very important because it can cause stroke, cardiac arrest, or even death. In this paper, we propose arrhythmia classification using hybrid combination model of CNN-BLSTM. For this purpose, the QRS features are detected from noise removed signal through pre-processing and a single bit segment was extracted. In this case, the GAN oversampling technique is applied to solve the data imbalance problem. It consisted of CNN layers to extract the patterns of the arrhythmia precisely, used them as the input of the BLSTM. The weights were learned through deep learning and the learning model was evaluated by the validation data. To evaluate the performance of the proposed method, classification accuracy, precision, recall, and F1-score were compared by using the MIT-BIH arrhythmia database. The achieved scores indicate 99.30%, 98.70%, 97.50%, 98.06% in terms of the accuracy, precision, recall, F1 score, respectively.