• 제목/요약/키워드: heart rate estimation

검색결과 64건 처리시간 0.03초

젊은 정상성인의 비운동 VO2max 추정식 (Non-Exercise VO2max Estimation for Healthy Young Adults)

  • 이정아;조상현;이충휘;권오윤
    • 한국전문물리치료학회지
    • /
    • 제12권3호
    • /
    • pp.74-83
    • /
    • 2005
  • The purpose of this study was to produce the regression equation from non-exercise $VO_{2max}$ of healthy young adults and to develop a maximal oxygen consumption ($VO_{2max}$) regression model. This model was based on heart rate non-exercise predictor variables (rest heart rate, maximal heart rate/rest heart rate), as an extra addition to the general regression which can reflect an individual's inherent or acquired cardiorespiratory fitness. The subjects were 101 healthy young adults aged 19 to 35 years. Exercise testing was measured by using a Balke protocol for treadmill and indirect calorimetry. The prediction equation was analyzed by using stepwise multiple regression procedures. The mean of $VO_{2max}$ was $39.02{\pm}6.72\;m{\ell}/kg/min$ (mean${\pm}$SD). The greatest variable correlated to $VO_{2max}$ was %fat. The predictor variable used in the non-exercise $VO_{2max}$ included %fat, gender, habitual physical activity and $HR_{max}/HR_{rest}$. The non-exercise $VO_{2max}$ estimation was as follows: $VO_{2max}$($m{\ell}/kg/min$)=55.58-.41(%fat)+.59(physical activity rating)-2.69($HR_{max}/HR_{rest}$)-5.36 (male=0, female=1); (R=.85, SEE=3.64, R2=.72: including heart rate variable); $VO_{2max}$($m{\ell}/kg/min$)=48.47-.41(%fat)+.45(physical activity rating)-5.12 (male=0, female=1); (R=.84, SEE=3.74, R2=.70: with the exception of heart rate variable). As an added heart rate variable, there was only a 2% coefficient of determination improved. Therefore, these results demonstrated that heart rate variable correlation with a non-exercise regression model was very low. In conclusion, for healthy young korean adults, those variables that can affect non-exercise $VO_{2max}$ estimation turned out to be only % fat, gender, and physical activity. We suggest that further research of predictor variables for non-exercise $VO_{2max}$ is necessary for different patient groups who cannot perform maximal exercise or submaximal exercise.

  • PDF

FRACTAL 차원을 이용한 심박변화 분석에 관한 연구 (A Study on Analysis of Heart Rate Variability Using Fractal Dimension)

  • 이병채;이명호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1994년도 추계학술대회
    • /
    • pp.169-171
    • /
    • 1994
  • This paper is to find out more reliable analyzing method of heart rate variability. Heart rate variability analysis is to evaluate cardiovascular stability and also have used as an indicator of autonomic nervous system activity. In this study, time domain analysis, spectral analysis and state space analysis method are applied to analyze heart rate variability. Because of nonlinear characteristics of heart rate, we need not only spectral analysis, but also state space analysis. Fractal dimension of spectral estimation is useful indicator of autonomic nervous activity.

  • PDF

실시간처리를 위한 태아심음 추출 알고리듬 (Fetal heart rate estimation algorithm for real-time processing)

  • 이응구;이용희;김선일;이두수
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1994년도 춘계학술대회
    • /
    • pp.96-99
    • /
    • 1994
  • Despite the simplicity of processing, a conventional autocorrelation function(ACF) method for the precise determination of fetal heart rate (FHR) has many problems. In case of weak or noise corrupted Doppler ultrasound signal. the ACF method is very sensitive to the threshold level and data window length. It is very troublesome to extract FHR when there is a data loss. To overcome these problems, the high resolution pitch detection algorithm was adopted to estimate the FHR. This method is more accurate, robust and reliable than the ACF method. With a lot of calculation, however, it is impossible to process real time FHR estimation. This paper is presented a new FHR estimation algorithm for real time processing.

  • PDF

심장운동부하 모델링과 의료장비 개발 (Modeling for the Work of Heart and Development of the WOH Medical device)

  • 노형운;서상호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.501-504
    • /
    • 2006
  • The estimation of the work of heart can be treated as one of the most important parameters for determining the amount of circulating blood needed for harmonious metabolism in the human body. By monitoring the work of heart, one can detect increased work load of heart and start the treatment at the early stage of CHF. Thus it is necessary to estimate the work of heart. The contractility of the left ventricle, the second important parameter for representing the motion of heart, can be estimated through information on the work of heart. In this study, the modified Windkessel model, which has been used for a measure of vascular hemodynamic impedance parameters, was adapted to estimate the work of heart.

  • PDF

개인용 컴퓨터를 이용한 전자 태아심음 감시장치의 개발에 관한 연구 (A Study on The Davelopement of Electronic Fetal Heart Rate Monitoring System Using Personal Computer)

  • 정지환;김선일
    • 대한의용생체공학회:의공학회지
    • /
    • 제12권3호
    • /
    • pp.209-214
    • /
    • 1991
  • Digital fetal monitoring system based on the personal computer combined with the digital signal processing (DSP) board was implemented. The DSP board acquires and digitally processes ultra- sound fetal Doppler signal for digital signal conditioning, rectification, low -pass filtering, autocorrealtion function calculation and its peak detection. The personal computer interfaced with the DSP board is in charge of graphic display, hardcopy, data transmission and on -line analysis of fetal heart rate change including on - line warning system, base -line estmation, acceleration, deceleration and variability. It is one of the most suitable situation to apply the DSP chip for siganl conditioning, digital filtering of ultrasound fetal Dopier signal and fetal heart rate estimation using autocorrelation technique .

  • PDF

PPG 기반 심박동수 추정 알고리즘 (Tracking Heart Rate Algorithm Based on PPG)

  • 백용현;이근상;박영철
    • 한국정보전자통신기술학회논문지
    • /
    • 제2권3호
    • /
    • pp.71-78
    • /
    • 2009
  • 본 논문에서는 측정된 PPG 신호로부터 심박동수를 추정 하는 방법을 제시한다. PPG 신호는 현관에 흐르는 혈류량을 측정한 것으로 심장의 수축과 이완에 영향을 받아 단일 주파수적인 특성을 가지며 이러한 특성을 이용하여 PPG 주파수를 2차 IIR 적응 놋치 필터로 추적한다. 적응 알고리즘을 통하여 지속적으로 필터 계수를 갱신하여 얻어진 PPG 주파수를 바탕으로 사람의 심박동수를추정한다.

  • PDF

안드로이드 기반 스마트폰 연동 심박변이도 추정 (Estimation of Heart Rate Variability with an Android Smart Phone Platform)

  • 김정환;신승원;김현태;윤태호;김경섭;이정환;엄광문
    • 전기학회논문지
    • /
    • 제61권6호
    • /
    • pp.865-871
    • /
    • 2012
  • In this study, ambulatory electrocardiogram(ECG) signal and the rhythms of heart beats are visualized in terms of R-R intervals and Heart Rate Variability(HRV) in the environment of an android plaform. With this aim, Graphical User Interface(GUI) is implemented by executing multi-thread Java programming modules including ECG, heart-beats, tachogram and visualization unit. ECG signals are acquired in an android device by receiving the data from ambulatory ECG sensory system. Finite Impulse Response(FIR) filters are implemented to eliminate the baseline wandering noises contained in the ambulatory signals and DC-offset level in R-R interval data. With simulating the normal or stress emotional state of a subject, we can find the fact that HRV can be successfully estimated and visualized in an android smart phone platform.

맥파전달속도를 이용한 내중막 두께 추정에 관한 연구 (A Study on Estimation of Carotid Intima-Media Thickness(IMT) using Pulse Wave Velocity(PWV))

  • 송상하;장승진;김원식;이현숙;윤영로
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권5호
    • /
    • pp.401-411
    • /
    • 2009
  • In this paper, we correct pulse wave velocity(PWV) with heart-rate and derive regression equations to estimate intima-media thickness(IMT). Widely used methods for diagnosis of arteriosclerosis are IMT and PWV. Arterial wall stiffness determines the degree of energy absorbed by the elastic aorta and its recoil in diastole but there is not correlation between sclerosis and IMT in an existing study. In this study, we will correct PWV with heart-rate and get regression equation to estimate IMT using heart-rate correction index(HCI). We executed experiments for this study. Made up question of physical condition and measured electrocardiogram(ECG), photoplethysmogram (PPG) of finger-tip and toe-tip and ultrasound image of carotid artery. Calculated PWV and IMT using ECG, PPG and ultrasound image. We found that every p-value between PWV and IMT is not significant(<0.05). But p-value between IMT and HCI which is a corrected PWV using heart-rate is significant(>0.01). We use HCI and various measured parameter for estimating regression equation and apply backward estimation to select parameters for regression analysis. Result of backward estimation, found that only HCI is possible to derive proper regression equation of IMT. Relationship between PWV and IMT is the second order. Result of regression equation of E-H PWV is $R^2$=0.735, adj $R^2$=0.711. This is the best correlation value. We calculate error of its analysis for verification of earlobe PWV regression equation. Its result is RMSEP=0.0328, MAPE(%) = 4.7622. Like this regression analysis, we know that HCI is useful parameter and relationship between PWV, HCI and IMT. In addition, we are able to suggest possibility which is that we can get different parameter of prediction throughout just one measurement.

Lomb-Scargle알고리즘에 의한 심박변동의 파워스펙트럼 추정 (The Power Spectral Estimation of Heart Rate Variability using Lomb-Scargle's algorithm)

  • 신건수;정기삼;최석준;이정환;이명호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.275-278
    • /
    • 1997
  • Standard methods estimating the power spectral density(PSD) from an irregularly sampled cardiac event series require deriving a new evenly-spaced signal applicable to those methods. To avoid that requirement, in this study, the power spectrum of heart rate variability was estimated by Lomb-Scargle's algorithm, which is a means of obtaining PSD estimates directly from irregularly sampled timeseries observed in astronomy. To assess the performance of Lomb-Scargle algorithm in the power spectral analysis of heart rate variability, it was applied to various cardiac event series derived through integral pulse frequency modulation model(IPFM) simulation and from real ECG signals, and the resultant power spectra was compared with those obtained by a conventional method based on the FFT. In result, it is concluded that Lomb-Scargle's periodogram is very effective in the power spectral analysis of heart rate variability, especially in the presence of arrhythmia and/or dropouts of cardiac events.

  • PDF

Comparisons of Core Temperature Between a Telemetric Pill and Heart Rate Estimated Core Temperature in Firefighters

  • Pearson, Stephen J.;Highlands, Brian;Jones, Rebecca;Matthews, Martyn J.
    • Safety and Health at Work
    • /
    • 제13권1호
    • /
    • pp.99-103
    • /
    • 2022
  • Background: Firefighters may experience high environmental temperatures or carry out intensive physical tasks, or both, which leads to increased core body temperature and risk of fatalities. Hence there is a need to remotely and non-invasively monitor core body temperature. Methods: Estimated (heart rate algorithm) and actual core body temperature (ingested telemetric pill) measures were collected simultaneously for comparison during training exercises on 44 firefighter volunteers. Results: Prediction of core body temperature varied, with no specific identifiable pattern between the algorithm values and directly measured body core temperatures. Group agreement of Lin's Concordance of 0.74 (95% Upper 0.75, lower CI 0.73), was deemed poor. Conclusion: From individual agreement data Lin's Concordance was variable (Min 0.11, CI 0.13-0.01; Max 0.83, CI 0.86-0.80), indicating that the heart rate algorithm approach was not suitable for core body temperature monitoring in this population group, especially at the higher more critical core body temperatures seen.