DOI QR코드

DOI QR Code

Comparisons of Core Temperature Between a Telemetric Pill and Heart Rate Estimated Core Temperature in Firefighters

  • Pearson, Stephen J. (Centre for Health, Sport and Rehabilitation Sciences Research, University of Salford) ;
  • Highlands, Brian (Greater Manchester Fire and Rescue Service) ;
  • Jones, Rebecca (Greater Manchester Fire and Rescue Service) ;
  • Matthews, Martyn J. (Centre for Health, Sport and Rehabilitation Sciences Research, University of Salford)
  • Received : 2021.09.09
  • Accepted : 2021.11.13
  • Published : 2022.03.30

Abstract

Background: Firefighters may experience high environmental temperatures or carry out intensive physical tasks, or both, which leads to increased core body temperature and risk of fatalities. Hence there is a need to remotely and non-invasively monitor core body temperature. Methods: Estimated (heart rate algorithm) and actual core body temperature (ingested telemetric pill) measures were collected simultaneously for comparison during training exercises on 44 firefighter volunteers. Results: Prediction of core body temperature varied, with no specific identifiable pattern between the algorithm values and directly measured body core temperatures. Group agreement of Lin's Concordance of 0.74 (95% Upper 0.75, lower CI 0.73), was deemed poor. Conclusion: From individual agreement data Lin's Concordance was variable (Min 0.11, CI 0.13-0.01; Max 0.83, CI 0.86-0.80), indicating that the heart rate algorithm approach was not suitable for core body temperature monitoring in this population group, especially at the higher more critical core body temperatures seen.

Keywords

Acknowledgement

Thanks go to Greater Manchester Fire and Rescue Service who provided funding and logistical support for this work.

References

  1. Lim CL, Byrne C, Lee JK. Human thermoregulation and measurement of body temperature in exercise and clinical settings. Ann Acad Med Singapore [Internet] 2008 Apr;37(4):347-53 [cited 2018 Oct 28]. Available from: http://www.ncbi.nlm.nih.gov/pubmed/18461221.
  2. Fox RH, Solman AJ, Isaacs R, Fry AJ, MacDonald IC. A new method for monitoring deep body temperature from the skin surface. Clin Sci 1973 Jan;44(1):81-6. https://doi.org/10.1042/cs0440081
  3. Fox RH, Solman AJ. A new technique for monitoring the deep body temperature in man from the intact skin surface. J Physiol 1971 Jan;212(2):8P-10P.
  4. Kitamura K-I, Zhu X, Chen W, Nemoto T. Development of a new method for the noninvasive measurement of deep body temperature without a heater. Med Eng Phys 2010 Jan;32(1):1-6. https://doi.org/10.1016/j.medengphy.2009.09.004
  5. Tachibana S, Chida Y, Yamakage M. Using the Bair Hugger TM temperature monitoring system in neck and chest regions: a pilot study. JA Clin Reports 2019 May;5(1):32. https://doi.org/10.1186/s40981-019-0252-z
  6. Buller MJ, Tharion WJ, Cheuvront SN, Montain SJ, Kenefick RW, Castellani J, et al. Estimation of human core temperature from sequential heart rate observations. Physiol Meas [Internet] 2013 Jul 1;34(7):781-98 [cited 2018 Mar 2]. Available from: http://stacks.iop.org/0967-3334/34/i=7/a=781?key=crossref.8c1701eaf2975a48c9f4e6ac1576bc99. https://doi.org/10.1088/0967-3334/34/7/781
  7. Buller MJ, Tharion WJ, Duhamel CM, Yokota M. Real-time core body temperature estimation from heart rate for first responders wearing different levels of personal protective equipment. Ergon [Internet] 2015 Nov 2;58(11):1830-41 [cited 2018 Mar 2]. Available from: http://www.tandfonline.com/doi/full/10.1080/00140139.2015.1036792.
  8. Feng J, Zhou C, He C, Li Y, Ye X. Development of an improved wearable device for core body temperature monitoring based on the dual heat flux principle. Physiol Meas [Internet] 2017 Apr 1;38(4):652-68 [cited 2018 Mar 2]. Available from: http://stacks.iop.org/0967-3334/38/i=4/a=652?key=crossref.ae487a50ff09ff581d9bf824f9542f7c. https://doi.org/10.1088/0967-3334/38/4/652
  9. Lin LI, McBride G, Bland JM, Altman DG. A proposal for strength-of-agreement criteria for Lin's Concordance Correlation Coefficient. NIWA Client Rep 2005;45(1):307-10.
  10. Welles AP, Buller MJ, Margolis L, Economos D, Hoyt RW, Richter MW. Thermal-work strain during marine rifle squad operations in Afghanistan. Mil Med [Internet] 2013 Oct 1;178(10):1141-8 [cited 2018 Mar 2]. Available from: https://academic.oup.com/milmed/article/178/10/1141-1148/4352250. https://doi.org/10.7205/MILMED-D-12-00538
  11. Weippert M, Behrens M, Gonschorek R, Bruhn S, Behrens K. Muscular contraction mode differently affects autonomic control during heart rate matched exercise. Front Physiol [Internet] 2015;6:156. Available from: https://www.frontiersin.org/article/10.3389/fphys.2015.00156.
  12. Xu X, Karis AJ, Buller MJ, Santee WR. Relationship between core temperature, skin temperature, and heat flux during exercise in heat. Eur J Appl Physiol [Internet] 2013 Sep 18;113(9):2381-9 [cited 2018 Oct 28]. Available from: http://link.springer.com/10.1007/s00421-013-2674-z.
  13. Welles AP, Xu X, Santee WR, Looney DP, Buller MJ, Potter AW, et al. Estimation of core body temperature from skin temperature, heat flux, and heart rate using a Kalman filter. Comput Biol Med 2018 Aug;99:1-6. https://doi.org/10.1016/j.compbiomed.2018.05.021