지향성 보청기 성능 검사 장치 개발 (Development of Directional Digital Hearing Aid Performance Testing System)

  • 장순석;권유정;이제형
    • 한국소음진동공학회논문집
    • /
    • 제16권1호
    • /
    • pp.81-88
    • /
    • 2006
  • The most recent trend on digital hearing aid is to increase the ratio of signal to noise by directivity or to develop noise reduction algorithm inside DSP IC chip. This paper designed, fabricated and tested a digital hearing aid directivity testing device in which a micro-mouse-like the stepping motor with a speaker rotates around an examinant. Both ears of the examinant were fixed with ITE hearing aids in order to respond to receiving sound. The experimental results were compared with those of a boundary element method program for verification. The diameter of the directivity testing device was 2 m and the micro-mouse was precisely controlled by PICBASIC micro processor.

지향성 보청기 성능 검사 장치 개발 (Development of Directional Digital Hearing Aid Performance Testing System)

  • 장순석;권유정;이제형
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.469-474
    • /
    • 2005
  • The most recent trend on digital hearing aid is to increase the ratio of signal to noise by directivity or to develop noise reduction algorithm inside DSP IC chip. This paper designed, fabricated and tested a digital hearing aid directivity testing device in which a micro-mouse-1ike the stepping motor with a speaker rotates around an examinant. Both ears of the examinant were fixed with ITE hearing aids in order to response to receiving sound. The experimental results were compared with a boundary element method program for verification. The diameter of the directivity testing device was 2 [m] and the micro-mouse was precisely controlled by PICBASIC micro processor.

  • PDF

Expansion of ATSC 3.0-Based Disaster Broadcasting Service for the Visually and Hearing Impaired

  • Song, Chong-Hyun
    • Journal of Multimedia Information System
    • /
    • 제9권3호
    • /
    • pp.227-232
    • /
    • 2022
  • Disasters are now becoming commonplace and especially the vulnerable group such as the disabled, the elderly, children and foreigners are in a state of overlapping disasters. In this situation, ATSC 3.0-based UHDTV disaster information service for the visually and hearing impaired has been developing. This study focuses on the demand data collected through in-depth interview with the impaired. The demand analysis data is very important to development process of technology. The results of the interview show that it is essential to link the UHDTV disaster signals with home-network, IoT, wearable devices, and various assistive devices for the impaired (hearing aid, smart light bulbs, warning light, etc.). In outdoor space, UHDTV disaster information must be connected to public display media, digital signage, kiosk, screens in bus or taxi. If communication aids for the visually and hearing impaired are equipped with a function that can transmit and receive disaster information, it will help to minimize disaster damage.

Sensorineural Hearing Loss and Wernicke Encephalopathy: A Case Report and Literature Review

  • Ton, Angie Nu;Jethwa, Trisha;Stamper, Greta C;Yenior, Ashley
    • Journal of Audiology & Otology
    • /
    • 제25권1호
    • /
    • pp.55-58
    • /
    • 2021
  • Sensorineural hearing loss (SNHL) is seldom associated with Wernicke encephalopathy (WE) or thiamine deficiency. While thiamine deficiency and repletion are often considered prior to dextrose infusions in patients with chronic alcohol abuse to prevent WE, they are often overlooked in non-alcoholic patients who are also at risk for malnutrition. In this paper we describe a case of a non-alcoholic 28-year-old female status post-sleeve gastrectomy who developed SNHL in the setting of thiamine deficiency and WE, with ongoing hearing impairment requiring hearing aids despite thiamine repletion.

Sensorineural Hearing Loss and Wernicke Encephalopathy: A Case Report and Literature Review

  • Ton, Angie Nu;Jethwa, Trisha;Stamper, Greta C;Yenior, Ashley
    • 대한청각학회지
    • /
    • 제25권1호
    • /
    • pp.55-58
    • /
    • 2021
  • Sensorineural hearing loss (SNHL) is seldom associated with Wernicke encephalopathy (WE) or thiamine deficiency. While thiamine deficiency and repletion are often considered prior to dextrose infusions in patients with chronic alcohol abuse to prevent WE, they are often overlooked in non-alcoholic patients who are also at risk for malnutrition. In this paper we describe a case of a non-alcoholic 28-year-old female status post-sleeve gastrectomy who developed SNHL in the setting of thiamine deficiency and WE, with ongoing hearing impairment requiring hearing aids despite thiamine repletion.

Hearing handicap inventory for elderly(HHIE)로 선별한 난청 노인들의 삶의 질 (The quality of life of elderly people with hearing loss selected by Hearing handicap inventory for elderly (HHIE))

  • 이현정;허승덕;황수연
    • 대한치료과학회지
    • /
    • 제10권2호
    • /
    • pp.39-45
    • /
    • 2018
  • Objective: The aimes of this study is to analyze the effects of presbycusis on the quality of life. Method: 47-elderly were participated. The participants were divided into the suspected hearing impaired group (N=18) and the within normal limits (WNL) group (N=29). One-way ANOVA was performed to determine the association between the HHIE and WHOQOL-BREF scores by age group, and independent t-test was carried out to analyze the inter-group relations. Results: The scores in WHOQOL-BREF differed significantly by age group (p=.011): people in their sixties scored $3.7{\pm}.62$, those in their seventies $3.3{\pm}.56$, and those in their eighties $2.8{\pm}.60$, with significant differences observed. There were statistically significant inter-group differences (p=.000), with significant differences observed. Conclusion: The quality of life of the elderly were lowered depending on age and hearing impairment.

디지털 보청기를 위한 저전력, 저잡음 전치증폭기 설계 (Desgin of Low-power, Low-noise Preamplifier for Digital Hearing-Aids)

  • 임새민;박상규
    • 전자공학회논문지
    • /
    • 제49권12호
    • /
    • pp.219-225
    • /
    • 2012
  • 디지털 보청기용 저전력, 저잡음 전치증폭기를 설계하였다. 본 전치증폭기는 일렛트렛 마이크로부터 싱글엔드 형태로 입력 받은 신호를 증폭한 후, 차동신호의 형태로 ADC에 전달한다. 또, 3.6, 7.2, 14.4, 28.8의 가변이득을 가지며 100Hz~10kHz의 주파수 대역에서 동작한다. 설계된 증폭기는 130nm CMOS 공정으로 제작되었으며, 1.2V 전원을 사용하여 측정한 결과 85dB의 SNR, 0.05%의 고조파 왜곡 및 $200{\mu}W$의 파워소모를 얻었다.

심박변이도 기반 청취 노력도 측정 연구 (Study on Listening Efforts Based on Heart Rate Variability)

  • 김현규;나영민;우지환
    • 대한의용생체공학회:의공학회지
    • /
    • 제40권3호
    • /
    • pp.75-80
    • /
    • 2019
  • Listening effort represents the listener's attention, stress, required cognition resource, and mental exertion to understand a speech in various situations. Recently, it has been focused to evaluate an effectiveness of hearing aids and cochlear implant. The physiologic measures, such as heart rate, skin conductance, electroencephalography, and pupil dilation, have been used to objectively measure listening effort. In this study, we investigated the feasibility of temporal and spectral heart rate variabilities to measure listening effort to understand speech in the presence of background noise. The results showed that several heart rate variabilities significantly increased as increasing background noise level. Finally, the heart rate variability can be used as an objective tool to measure listening efforts.

보청기용 비상관 궤환제거 알고리즘 (A Decorrelative Feedback Cancellation Algorithm for Hearing Aids)

  • 이행우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2009년도 추계학술대회
    • /
    • pp.699-702
    • /
    • 2009
  • 본 논문에서는 음향궤환제거기의 수렴특성을 향상시키기 위한 새로운 적응 알고리즘을 제안하였다. 이 알고리즘은 음성신호와 같이 상관도가 높은 신호를 사용하여 적응필터의 계수를 갱신할 때 궤환신호의 상관도를 감소시켜주기 위해 비상관 잡음을 사용함으로서 수렴성능을 향상시킨다. 시뮬레이션 결과, 제안한 궤환제거 알고리즘은 약 20 dB 이상의 SNR 성능이 개선되는 것을 보여 주었다.

  • PDF

Safety and efficacy of transcutaneous bone conduction implant surgery for hearing improvement in microtia patients with bilateral hearing impairment

  • Cheon, Jeong Hyun;Lee, Hyung Chul;Im, Gi Jung;Park, Jung Youl;Park, Chul
    • Archives of Plastic Surgery
    • /
    • 제46권6호
    • /
    • pp.525-534
    • /
    • 2019
  • Background In microtia patients with bilateral hearing impairment, hearing improvement is crucial for language development and performance. External auditory canal reconstruction (EACR) has been performed to improve hearing, but often results in complications. We performed transcutaneous bone conduction implant (TBCI) surgery in these patients. This study aimed to evaluate the safety and efficacy of TBCI surgery. Methods A retrospective review was performed of five patients who underwent auricular reconstruction and TBCI surgery and 12 patients who underwent EACR between March 2007 and August 2018. Hearing improvement was measured based on the air-bone gap values using pure-tone audiometry over a 6-week postoperative period. We reviewed other studies on hearing improvement using EACR and compared the findings with our results. The surgical techniques for TBCI were reviewed through case analyses. Results Postoperative hearing outcomes showed a significant improvement, with a mean gain of 34.1 dB in the TBCI cohort and 14.1 dB in the EACR cohort. Both gains were statistically significant; however, the TBCI cohort showed much larger gains. Only three of the 12 patients who underwent EACR achieved hearing gains of more than 20 dB, which is consistent with previous studies. All patients who underwent TBCI surgery demonstrated hearing gains of more than 20 dB and experienced no device-related complications. Conclusions TBCI is a safe and effective method of promoting hearing gains in microtia patients with bilateral hearing impairment. TBCI surgery provided better hearing outcomes than EACR and could be performed along with various auricular reconstruction techniques using virgin mastoid skin.