• 제목/요약/키워드: hearing aid

검색결과 175건 처리시간 0.026초

디지털 보청기 적합 검증을 위한 전기음향 시험장치 개발 (Digital Hearing Aid Fitting Program Testing System Development)

  • 장순석;권유정;이제형
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.415-418
    • /
    • 2005
  • DSP chip parameters of a digital hearing aid (HA) should be optimally selected or fitted for hearing impaired persons. The more precise parameter fitting guarantees the better compensation of the hearing loss (HL). Digital HAs adopt DSP chips for more precise fitting of various HL threshold curve patterns. A specific DSP chip such as Gennum GB3211 was designed and manufactured in order to match up to about 4.7 billion different possible HL cases with combination of 7 limited parameters. This paper deals with a digital HA fitting program which is developed for optimal fitting of GB3211 DSP chip parameters. The fitting program has completed feature from audiogram input to DSP chip interface. The compensation effects of the microphone and the receiver are also included. The paper shows some application examples.

  • PDF

Digital Hearing Aids Specific $\mu$DSP Chip Design by Verilog HDL

  • Jarng, Soon-Suck;Chen, Lingfen;Kwon, You-Jung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.190-195
    • /
    • 2005
  • The hearing aid chip described in this paper is an analog & digital mixed system. The design focuses on the$\mu$DSP core. This $\mu$DSP core includes internal time delays to two inputs from front and rear microphones. The paper consists of two parts; one is the composure and signal processing algorithm of digital hearing aids and the other is Verilog HDL codes for$\mu$DSP cores. All digital modules in the design were coded and synthesized by Verilog HDL codes which were verified by Mentor Graphics and Synopsis semiconductor chip design tools.

  • PDF

귀속형 디지털 보청기 제작을 위한 PCB설계 (PCB layout for ITE digital hearing aids manufacture)

  • 장순석;김경석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.577-579
    • /
    • 2004
  • Digital hearing aids enclose $6{\sim}8$ tiny components. Those electromechanical components are individually wired by soldering which is a manual labor and sometimes causes components' damage by heating. This paper suggests a PCB design for overcome these problems. Several PCBs are designed and manufactured and circuited to produce ITE(In The Ear) type hearing aids which are inserted in the ear canal. The most optimal size of the PCB design for the ITE hearing aid is presented in this paper.

  • PDF

디지털 보청기용 PCB 제작 (PCB Layout for Digital Hearing Aids)

  • 장순석;김경석;권유정
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1012-1015
    • /
    • 2004
  • Digital hearing aids enclose $6{\sim}8$ tiny components. Those electromechanical components are individually wired by soldering which is a manual labor and sometimes causes components' damage by heating. This paper suggests a PCB design for overcome these problems. Several PCBs are designed and manufactured and circuited to produce ITE(In-the-Ear) type hearing aids which are inserted in the ear canal. The most optimal size of the PCB design for the ITE hearing aid is presented in this paper.

  • PDF

보청기에서 음성 대비 강조에 의해 발생할 수 있는 마스킹 현상 (Acoustic Masking Effect That Can Be Occurred by Speech Contrast Enhancement in Hearing Aids)

  • 전유용;양동권;방동혁;길세기;이상민
    • 재활복지공학회논문지
    • /
    • 제1권1호
    • /
    • pp.21-28
    • /
    • 2007
  • 대부분의 보청기에서는 난청인의 청력 손실을 보상하기 위해 음성 증폭 알고리즘과 잡음 및 피드백을 제거하기 위한 알고리즘 등을 사용하고 있고, 음성의 인지율을 높이기 위해서 음성의 대비를 강조하는 알고리즘을 사용한다. 음성 대비 강조 알고리즘 사용 시 과도한 대비증폭에 의해서 포먼트(formant) 사이에서 마스킹 현상이 발생할 수 있다. 마스킹 현상을 확인하기 위해서 6가지의 주관적인 평가와 1가지의 객관적인 평가를 수행하였다. 주관적인 평가로는 순음 검사, 어음 청취 역치 검사, 낱말 분별력 검사, 순음 마스킹 검사, 포먼트 순음 마스킹 검사, 어음 마스킹 검사로 이루어져있고 객관적인 평가를 위해서 LLR(log likelihood ratio)을 도입하였다. 정상 청각 피험자와 난청 피험자의 결과로 미루어 볼 때, 난청 피험자가 마스킹이 잘 일어난다는 것을 볼 수 있었고, 어음을 이용한 마스킹 검사에서는 마스킹에 의해서 난청 피험자에서 어음에 대한 인지율이 떨어지는 결과를 볼 수 있다. 이러한 현상은 포먼트 향상에 의한 왜곡 때문이 아닌 마스킹 때문이다. 그러므로 마스킹 효과의 특성을 조사하여, 보청기 적합 시, 이러한 마스킹 특성을 고려하는 것이 필요하다.

  • PDF

Clinical Factors Influencing the Trial and Purchase of Bilateral Microphones with Contralateral Routing of Signal in Patients with Asymmetric Sensorineural Hearing Loss

  • Seong, Jeon;Yang, Seung Koo;Jang, Pilkeun;Lee, Sang-Yeon;Carandang, Marge;Choi, Byung-Yoon
    • Journal of Audiology & Otology
    • /
    • 제24권1호
    • /
    • pp.29-34
    • /
    • 2020
  • Background and Objectives: Bilateral microphones with contralateral routing of signal (BiCROS) hearing aid is an option for hearing rehabilitation in individuals with asymmetric sensorineural hearing loss (ASNHL). The clinical factors influencing the trial and purchase of BiCROS were investigated. Subjects and Methods: We reviewed the medical records of 78 patients with ASNHL who were recommended to use BiCROS and analyzed the demographic and audiological factors influencing the trial and purchase of BiCROS. Results: Among the 78 patients, 52 (66.7%) availed of the free BiCROS trial and 21 (26.9%) purchased BiCROS. The mean pure tone audiometry (PTA) air conduction (AC) threshold of the better- and worse-hearing ears were 44.2±12.8 dB and 90.7±22.5 dB HL, respectively. The decision for trial or purchase of BiCROS was not influenced by age, sex, duration of hearing loss of the worse-hearing ear, or PTA AC threshold or speech discrimination score of both ears. The first and third quartiles of the PTA AC thresholds for the better-hearing ear of BiCROS buyers were 38.75 dB and 53.75 dB HL, respectively. The counterpart values for the worse-hearing ear were 72.50 dB and 118.75 dB HL, respectively. Conclusions: The clinical factors analyzed in this study were found to be irrelevant to the trial and purchase of BiCROS in patients with ASNHL. Nevertheless, the distribution range of the auditory thresholds of the subjects using BiCROS can be a useful basis for the counseling of patients with ASNHL and selection of candidates for BiCROS use.

이식형 보청기에 의한 자기공명 영상의 인공음영 축소를 위한 외부 코일 시스템 설계 (Design of External Coil System for Reducing Artifact of MR Image due to Implantable Hearing Aid)

  • 안형준;임형규;김명남;조진호
    • 한국멀티미디어학회논문지
    • /
    • 제19권2호
    • /
    • pp.375-385
    • /
    • 2016
  • Recently, several implantable hearing aids such as cochlear implant, middle ear implant, etc., which have a module receiving power and signal from outside the body, are frequently used to treat the hearing impaired patients. Most of implantable hearing aids are adopted permanent magnet pairs to couple between internal and external devices for the enhancement of power transmission. Generally, the internal device which containing the magnet in the center of receiving coil is implanted under the skin of human temporal bone. In case of MRI scanning of a patient with the implantable hearing aid, however, homogeneous magnetic fields of the MRI might be interfered by the implanted magnet. For the above reasons, the MR image is degraded by large area of artifact, so that diagnostics are almost impossible in deteriorated region. In this paper, we proposed an external coil system that can reduce the artifact of MR image due to the internal coupling magnet. By finite element analysis estimating area of MR artifact according to varying current and shape of the external coil, optimal coil parameters were extracted. Finally, the effectiveness of the proposed external coil system was verified by confirming the artifact at real MRI scan.

다중밴드 이득 보정기능을 갖는 디지털 청력보정회로 설계 (Design of a new digital hearing aid based on a multi-band compensation technique)

  • 최원철;이제훈;김영주;조경록
    • 전자공학회논문지SC
    • /
    • 제41권1호
    • /
    • pp.41-54
    • /
    • 2004
  • 본 논문에서는 감음신경성 난청자의 비선형적으로 변하는 가청 한계값을 보상하는 청력보정회로를 제안한다. 제안된 청력 보정 회로는 주파수 대역에서 직접 보상하기 위해 FFT와 IFFT 프로세서를 사용하고, 회로크기를 줄이기 위해 입력신호 크기 제어 방식을 사용한다. 제안된 청력보정 회로는 기존의 FIR필터 구조가 적용된 청력보정 회로보다 다중밴드 이득 보정이 가능하기 때문에 주파수 보정능력이 감음신경성 난청자에 대해 약 $15\%$이상 향상된 결과를 나타낸다. 입력신호 제어방식 적용으로 입출력 비트가 제한되지 않은 프로세서보다 하드웨어 크기는 $65\%$ 감소된다.

CMOS 아날로그 보청기 증폭회로의 최적 설계 (Optimal Design for CMOS Analog Hearing Aid OP Amp Circuit)

  • 장순석;진능풍
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 하계종합학술대회 논문집(2)
    • /
    • pp.443-446
    • /
    • 2004
  • Short channel IC circuits become increasingly important in modern high performance electronic systems. In this paper, parts of an analog hearing aid, an amplifier and a regulator, which are implemented with short channel CMOS devices, are designed and optimized in its performance.

  • PDF

보청기 호환성 전화기의 자계세기에 관한 기술기준 (Technical standards on magnetic field strength for a hearing-aid-compatible telephone)

  • 강경옥;강성훈
    • 한국음향학회지
    • /
    • 제13권3호
    • /
    • pp.78-84
    • /
    • 1994
  • 보청기가 자계 pick-up 코일을 구비하고 있고, 전화 수화기에서 충분한 자계를 발생할 경우의 전화 수화기와 보청기의 자기결합을 이용한 전화기를 보청기 호환성 전화기 (hearing-aid-compatible telephone)라고 한다. 본 고에서는 보청기와 전화 수화기의 결합방법과 자계결합에 관한 국제 기준을 고찰하여, 국내의 보청기 호환성 전화기의 자계 기준 및 측정법에 관한 검토사항을 제시한다.

  • PDF