• Title/Summary/Keyword: healthcare device

Search Result 382, Processing Time 0.036 seconds

Smart Home Healthcare Device based on Ubiquitous Communication

  • Kim, Keun-Young;Cha, Joo-Hun;Park, Mig-Non
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2235-2239
    • /
    • 2003
  • The aim of this research is to study and develop enabling technologies for home healthcare device with ubiquitous network. The motivation of this paper is to enable healthcare in home, to development the device for smart home health care. To achieve the aim, we must develop the prototype platform based on home gateways, distributed context user interface based on UPnP and support for information sharing with high speed power line communication and mobile infra-structures. And IPv6 is the base technology of this platform. In this paper, we concern that physical health, mental health and medical emergencies is all of home healthcare. With the smart device, we evaluate the connectivity, automatic information extraction and private data exchange and event driven message. The result of this paper is demonstration of smart device for ubiquitous communication in a healthcare application such as patient monitoring device and several information services. In conclusion, home healthcare will support more healthy and easy living for a human.

  • PDF

Effect of Exercise Using an Automatic Spine Extension Device on Thoracic Kyphotic and Extension Angles

  • Kim, Ju-hyeon;Park, Seon-mi;Sin, Hyang-hee;Choi, Ho-jeong;Liu, Yaoyao;Yoo, Won-gyu
    • Physical Therapy Korea
    • /
    • v.29 no.3
    • /
    • pp.235-240
    • /
    • 2022
  • Background: A spinal extension and intensive rehabilitation program reduced the symptoms and pain of kyphosis, and improved function. Objects: This study aimed to demonstrate the effect of a spine extension device on the degree of thoracic kyphosis and extension angles, confirm reduction of the kyphosis angle and an increase in flexibility. Methods: Thirteen adults were enrolled in the experiment, using the spine extension device, which was set to passively extend the spine. The angle between the spinous process of the first thoracic vertebra and the spinous process of the twelfth thoracic vertebra was measured by dual inclinometer before and after using the spine extension device. Results: In the static posture, the thoracic kyphosis decreased after using the spine extension device in the thoracic extension posture, and there was a significant difference (p < 0.05); thoracic extension angle increased with statistical significance (p < 0.05). Conclusion: In this study, the thoracic kyphosis angle and thoracic extension angle of the subjects before and after using spine extension device was compared and analyzed, which proved that the spine extension device can effectively improve the mobility of spinal extension.

u-Healthcare Monitoring System Design using by Smartphone based on Bluetooth Health Device Profile (Bluetooth Health Device Profile기반 스마트폰을 이용한 u-Healthcare 모니터링 시스템 설계)

  • Cho, Kyoung-Lae;Kim, Sang-Yoon;Kim, Jung-Han;Oh, Am-Suk;Kim, Gwan-Hyung;Jean, Jae-Hwan;Kang, Sung-In
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.6
    • /
    • pp.1365-1369
    • /
    • 2013
  • Recently, the Personal Health Device(PHD) that measures various biometric data easily are highlighted for ensuring portability, scalability and interoperability among the device as well as needs for a standardization of managing information measured by. In this paper, we'd like to propose u-healthcare monitoring system that measure biometric data(Oxygen saturation, Body weight, ECG and Blood pressure) by PHD featured with transferring data into devices such as smartphone using Bluetooth Health Device Profile(HDP) based on the ISO/IEEE 11073.

An Empirical Study on Acceptance Intention Towards Healthcare Wearable Device (기술 및 개인적 특성이 헬스케어 웨어러블 디바이스 수용의도에 미치는 영향에 관한 연구)

  • Lee, Sang-Il;Yoo, Wang-Jin;Park, Hyun-Sun;Kim, Sang-Hyun
    • The Journal of Information Systems
    • /
    • v.25 no.2
    • /
    • pp.27-50
    • /
    • 2016
  • Purpose The purpose of this study is to examine the effect of the acceptance intention towards healthcare wearable device in Korea. Specifically, this study attempted to identify the relationships among the acceptance intention towards healthcare wearable device, technical characteristics and user's personal characteristic based on UTAUT(Unified Theory of Acceptance and Use of Technology) model. Design/methodology/approach For this purpose of research, we conducted against consumers who use the wearable devices and we collected data from 219 wearable device users. The analyses were conducted using SPSS and AMOS19.0 which is powerful structural equation modeling (SEM) software. Findings The main findings are as followed; First, functional diversity, wearability, trend sensitivity and health perception are significantly related to performance expectancy, while visual aesthetic and enjoyment are not significantly related. Second, performance expectancy and effort expectancy are significantly related to acceptance intention towards healthcare wearable device. Third, effort expectancy is significantly related to performance expectancy.

Detecting Bladder Biomarkers for Closed-Loop Neuromodulation: A Technological Review

  • Park, Eunkyoung;Lee, Jae-Woong;Kang, Minhee;Cho, Kyeongwon;Cho, Baek Hwan;Lee, Kyu-Sung
    • International Neurourology Journal
    • /
    • v.22 no.4
    • /
    • pp.228-236
    • /
    • 2018
  • Neuromodulation was introduced for patients with poor outcomes from the existing traditional treatment approaches. It is well-established as an alternative, novel treatment option for voiding dysfunction. The current system of neuromodulation uses an open-loop system that only delivers continuous stimulation without considering the patient's state changes. Though the conventional open-loop system has shown positive clinical results, it can cause problems such as decreased efficacy over time due to neural habituation, higher risk of tissue damage, and lower battery life. Therefore, there is a need for a closed-loop system to overcome the disadvantages of existing systems. The closed-loop neuromodulation includes a system to monitor and stimulate micturition reflex pathways from the lower urinary tract, as well as the central nervous system. In this paper, we reviewed the current technological status to measure biomarker for closed-loop neuromodulation systems for voiding dysfunction.

Trend of IoT-based Healthcare Service (사물인터넷 기반 헬스케어 서비스 기술 동향)

  • Heo, Sung-Phil;Noh, Dong-Hee;Moon, Chang Bae;Kim, Dong-Sung
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.10 no.4
    • /
    • pp.221-231
    • /
    • 2015
  • This paper provides the trend of Internet of Things (IoT) for smart healthcare services and applications. IoT has provided a promising opportunity to build intelligent healthcare system and smart wearable applications by using the growing capability of wireless mobile devices, interactive sensors/actuators, and RFID technologies. For analysis of state-of-art technology of smart healthcare system, this paper includes comparative analysis and investigation of existing standard, network protocol, and devices, etc. In this paper, we examine the market trend of IoT healthcare. In particular, we examine the variety of IoT based healthcare type such as mobile, wearable device. After that, we examine the technologies of IoT healthcare such as standard, sensor, network and security. This survey contributes to better understanding of the challenges in existing IoT healthcare and further new light on future research directions.

A Study on Wearable Healthcare Device Adoption : An Integrated Approach of UTAUT2 and MIR (웨어러블 헬스케어 기기의 수용에 관한 연구: 확장된 통합기술수용모형과 혁신저항모형의 통합적 접근)

  • Jin, Seok;Ahn, Hyunchul
    • The Journal of Information Systems
    • /
    • v.28 no.3
    • /
    • pp.159-202
    • /
    • 2019
  • Purpose The purpose of this study is to explain users' wearable healthcare device adoption using performance expectancy, effort expectancy, the hedonic motivation and price value of UTAUT2, and to identify the causal relationship between intention to use wearable healthcare device and innovation resistance formed by perceived risks. Design/methodology/approach The research model proposed in this study is based on UTAUT2(Extended Unified Theory of Acceptance and Use of Technology) and MIR(Model of Innovation Resistance). In specific, performance expectancy, effort expectancy, hedonic motivation and price value of UTAUT2 and innovation resistance formed by perceived risks of MIR are adopted in our research model. To validate the research model, we carry out the analysis of the survey data using Smart PLS 3.0 to test the hypotheses. Findings According to the empirical analysis results, this study confirms that the performance expectancy, effort expectancy, hedonic motivation, and price value have significant effects on the intention to use wearable healthcare devices. It also finds that perceived risk affects innovation resistance and in turn, innovation resistance affects the intention to use wearable healthcare devices.

Current Developments of Biomedical Mobile Devices for Ubiquitous Healthcare (u-Healthcare를 위한 바이오 단말기의 개발 현황)

  • Lee, Tae-Soo;Hong, Joo-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.3
    • /
    • pp.185-190
    • /
    • 2009
  • Biomedical mobile devices for ubiquitous healthcare consist of biomedical sensors and communication terminal. They have two types of configuration. One is the sensor-network type device using wired or wireless communication with intelligent sensors to acquire biomedical data. The other is the sensor embedded type device, where the data can be acquired directly by itself. There are many examples of sensor network type, such as, fall detection sensor, blood glucose sensor, and ECG sensors networked with commercial PDA phone and commercial phone terminal for ubiquitous healthcare. On the other hand, sensor embedded type mounts blood glucose sensor, accelerometer, and etc. on commercial phone. However, to enable true ubiquitous healthcare, motion sensing is essential, because users go around anywhere and their signals should be measured and monitored, when they are affected by the motion. Therefore, in this paper, two biomedical mobile devices with motion monitoring function were addressed. One is sensor-network type with motion monitoring function, which uses Zigbee communication to measure the ECG, PPG and acceleration. The other is sensor-embedded type with motion monitoring function, which also can measure the data and uses the built-in cellular phone network modem for remote connection. These devices are expected to be useful for ubiquitous healthcare in coming aged society in Korea.

u-Healthcare Monitoring System Design using by Smartphone base on Bluetooth Health Device Profile (Bluetooth Health Device Profile기반 스마트폰을 이용한 u-Healthcare 모니터링 시스템 설계)

  • Cho, Kyoung-lae;Kim, Sang-yoon;Kim, Jung-han;Oh, Am-Suk;Jean, Jae Hwan;Kang, Sung-in
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.392-394
    • /
    • 2013
  • 최근 u-Healthcare 서비스에서 다양한 생체정보를 간편하게 측정하는 개인건강기기(PHD)와 측정된 정보를 전송하고 수집하기 위한 표준의 필요성이 제품 간의 이식성, 확장성, 상호 운영성을 보장하기 위해 크게 대두되고 있다. 개인건강기기에서 측정된 생체정보(산소포화도, 몸무게, 심전도, 혈압 등)를 ISO/IEEE 11073 기반인 Bluetooth Health Device Profile을 이용해서 스마트폰으로 실시간 모니터링 할 수 있는 시스템을 설계한다.

  • PDF