• Title/Summary/Keyword: health signal

Search Result 980, Processing Time 0.025 seconds

Implementation of the ECG Monitoring System for Home Health Care Using Wiener Filtering Method (Wiener Filtering 기법을 적용한 홈헬스케어용 심전도 신호 모니터링 시스템 구현)

  • Jeong, Do-Un;Kim, Se-Jin
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.9 no.2
    • /
    • pp.104-111
    • /
    • 2008
  • The ECG is biomedical electrical signal occurring on the surface of the body due to the contraction and relaxation of the heart. This signal represents an extremely important measure for health monitoring, as it provides vital information about a patient's cardiac condition and general health. ECG signals are contaminated with high frequency noise such as power line interference, muscle artifact and low frequency nose such as motion artifact. But it is difficult to filter nose from ECG signal, and errors resulting from filtering can distort a ECG signal. The present study implemented a small-size and low-power ECG measurement system that can remove motion artifact for convenient health monitoring during daily life. The implemented ECG monitoring system consists of ECG amplifier, a low power microprocessor, bluetooth module and monitoring program. Amplifier was designed and implemented using low power instrumentation amplifier, and microprocessor was interfaced to the ECG amplifier to collect the data, process, store and feed to a transmitter. And bluetooth module used to wirelessly transmit and receive the vital sign data from the microprocessor to an PC at the receiving site. In order to evaluate the performance of the implemented system, we assessed motion artifact rejection performance in each situation with artificially set condition using adaptive filter.

  • PDF

Non-contact damage monitoring technique for FRP laminates using guided waves

  • Garg, Mohit;Sharma, Shruti;Sharma, Sandeep;Mehta, Rajeev
    • Smart Structures and Systems
    • /
    • v.17 no.5
    • /
    • pp.795-817
    • /
    • 2016
  • A non-contact, in-situ and non-invasive technique for health monitoring of submerged fiber reinforced polymers (FRP) laminates has been developed using ultrasonic guided waves. A pair of mobile transducers at specific angles of incidence to the submerged FRP specimen was used to excite Lamb wave modes. Lamb wave modes were used for comprehensive inspection of various types of manufacturing defects like air gaps and missing epoxy, introduced during manufacturing of FRP using Vacuum Assisted Resin Infusion Molding (VARIM). Further service induced damages like notches and surface defects were also studied and evaluated using guided waves. Quantitative evaluation of transmitted ultrasonic signal in defect ridden FRPs $vis-{\grave{a}}-vis$ healthy signal has been used to relate the extent of damage in FRPs. The developed technique has the potential to develop into a quick, real time health monitoring tool for judging the service worthiness of FRPs.

Architecture & Analysis of $SpO_2$ Computing Model Using Integral Ratio of Pulsating Components (맥동성분의 적분비를 이용한 펄스 옥시메터의 산소포화도 계산모델 설계 및 분석)

  • Kim, Y.Y.;Kim, D.C.;Lee, Y.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.267-270
    • /
    • 1997
  • Oxygen saturation is an important parameter in clinical fields; fetal monitoring, apnea, emergency medicine etc. Because of monitoring patients continuously, pulse oximeter that measures oxigen saturation non-invasively is regarded attentively. But, though research about accuracy of signal extraction has been developed, it actually plays a supplementary part in hospital for not trusting the principle of measurement by clinicians. In this paper focusing on these things, first we suggested simple mathematical modelling on separating do components, ac components andnoise components in optical signal transmitted from fingertip or earlobe, and then we considered oxygen saturation computing algorithm using integral ratio of pulsating components. Last, we analyzed its effect by comparing received data.

  • PDF

Reviews on innovations and applications in structural health monitoring for infrastructures

  • Li, Hong-Nan;Yi, Ting-Hua;Ren, Liang;Li, Dong-Sheng;Huo, Lin-Sheng
    • Structural Monitoring and Maintenance
    • /
    • v.1 no.1
    • /
    • pp.1-45
    • /
    • 2014
  • The developments and implementations of the structural health monitoring (SHM) system for large infrastructures have been gradually recognized by researchers, engineers and administrative authorities in the last decades. This paper summarizes an updated review on innovations and applications in SHM for infrastructures carried out by researchers at Dalian University of Technology. Invented sensors and data acquisition system are firstly briefly described. And then, some proposed theories and methods including the sensing technology, sensor placement method, signal processing and data fusion, system identification and damage detection are discussed in details. Following those, the activities on the standardization of SHM and several case applications on specific types of structure are reviewed. Finally, existing problems and promising research efforts in the field of SHM are given.

Integrated Bio-signal Management System Through Network (네트워크를 통한 의료정보관리시스템에 관한 연구)

  • Lee, W.H.;Suk, J.H.;Yoon, Y.R.;Yoon, H.R.;Kang, D.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.151-153
    • /
    • 1996
  • The purpose of this paper is the development of Integrated Bio-signal Management System(IBMS) using the network. IBMS is the system to manage the medical signals that measured from the each independent medical measurement system module. Each has a LAN. We developed the file-server network using Novell Netware. Also, we developed the Graphic User Interface software for IBMS using Visual C++ at Windows 3.1.

  • PDF

Development of Holter analysis system by visual programming (시각화 프로그래밍에 의한 Holter 분석 시스템 개발)

  • Lee, S.J.;Song, G.K.;Lee, K.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.207-212
    • /
    • 1996
  • In this paper, we designed a Holter analysis system using the visual programming method. It differs from the existing analysis system in that the various signal processing algorithms represented by icons were designed by GUI concept which provide unskilled user with easy and convenient analysis environment. In order to analysis ECG signal, we only select the icon representing a algorithm to be applied by mouse and arrange the selected icons upon the order to be processed on screen. As a result it provides a convenient usage and flexibility of analysis. Finally, we can find the optimal algorithm for the ambulatory ECG analysis by comparing the several results obtained from the various analysis configuration.

  • PDF

A Study on Performance Evaluation for Electrocardiography Signal Measurement Electrode based on Conductive Fabric (전도성 섬유 기반 심전도 전극의 성능 평가에 관한 연구)

  • Kang, Bo Kyu;Yoo, Sun Kook
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.2
    • /
    • pp.210-220
    • /
    • 2013
  • Recently, as we move toward a society with an increasingly aged population, wearable U-health devices in various shapes with smart wear have been developed in order to conveniently measure health variables without using hands in daily life or at home. However, the problem is that only supply of the wearable U-health devices is focused and its applicable devices are studied and developed, which has resulted in lack of awareness of importance of performance evaluation. In this study, two electrodes were fabricated using conductive fabric which can be used as electrode if attached to wearable U-health devices or smart wear in order to measure ECG signal. Two electrodes those were fabricated using conductive fabric were compared the correlation, impedance and CMRR with patch typed Ag-AgCl electrode-normally used for measurement of ECG signal, so that the study would find out if the fabricated electrode can be used with the wearable U-health devices by testing and evaluating performances.

Relationship between Functional Fitness and Break Response in Elderly Drivers: Comparison with Young Driver

  • Kim, Ga Eun;Choi, Ye Eun;Yang, Su Seong;Kim, Sun A;Bae, Young Sook
    • The Journal of Korean Physical Therapy
    • /
    • v.30 no.5
    • /
    • pp.187-192
    • /
    • 2018
  • Purpose: This study compared the functional fitness and brake response of elderly and young drivers to confirm the correlation between the functional fitness and brake response. Methods: This study was a cross sectional observational design. Older drivers (>65age, n=21) and young adult drivers (20-40aged, n=20) were enrolled as subjects. The functional fitness of the subjects was measured using a senior fitness test consisting of a back scratch (BS), chair sit and reach (CSR), arm curl (AC), chair stand up (CSU), foot up and go (8-FUG), and 2-minute step (2-MS). The brake response used the virtual driving simulator to measure the brake reaction time (BRT) and braking distance (BD) according to the pedestrian protection and traffic signal compliance. Results: The older drivers had a lower BS (p<0.000), CSU (p=0.040), and 8-FUG (p=0.011) than the young adult drivers. BS and 8-FUG showed a significant positive correlation with the BRT and BD of pedestrian protection and traffic signal compliance. CSU showed a significant negative correlation with the BRT of pedestrian protection and traffic signal compliance. Conclusion: These findings suggest that the flexibility of the upper extremity, lower extremity strength, and agility are strongly correlated with the driving performance of elderly drivers.

Simple and Sensitive Electrochemical Sandwich-type Immunosensing of Human Chorionic Gonadotropin based on b-cyclodextrin Functionalized Graphene

  • Linfen Xu;Ling liu;Xiaoyan Zhao;Jinyu Lin;Shaohan Xu;Jinlian He;Debin Jiang;Yong Xia
    • Journal of Electrochemical Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.51-58
    • /
    • 2023
  • The effective detection of human chorionic gonadotropin (HCG) is considerably important for the clinical diagnosis of both of early pregnancy and nonpregnancy-related diseases. In this work, a simple and sensitive electrochemical sandwich-type immunosensing platform was designed by synthesizing b-cyclodextrin (CD) functionalized graphene (CD/GN) hybrid as simultaneously sensing platform and signal transducer coupled with rhodamine b (RhB) as probe. In brief, GN offers large surface area and high conductivity, while CD exhibits superior host-guest recognition capability, thus the primary antibody (Ab1) of HCG can be bound into the cavities of CD/GN to form stable Ab1/CD/GN inclusion complex; meanwhile, the secondary antibody (Ab2) and RhB can also enter into the cavities, producing RhB/Ab2/CD/GN complex. Then, by using Ab1/CD/GN as sensing platform and RhB/Ab2/CD/GN as signal transducer (in which RhB was signal probe), a simple sandwich-type immunosensor was constructed. Under the optimum parameters, the designed immunosensor exhibited a considerable low analytical detection of 1.0 pg mL-1 and a wide linearity of 0.002 to 10.0 ng mL-1 for HCG, revealing the developed sandwich-type electrochemical immunosensing platform offered potential real applications for the determination of HCG.

PPG Filtering Method for Respiration Measurement in U-Health Care System (U-Health Care 환경에서 호흡측정을 위한 PPG 최적필터기술)

  • Kim, Jong-Hwa;Whang, Min-Cheol;Nam, Ki-Chang
    • Journal of the Ergonomics Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.95-101
    • /
    • 2008
  • This research is to develop PPG filtering method for respiration measurement in U-Health Care system. Respiration rate was determined by filtering PPG and analyzing its spectrum. Optimal filter of PPG has been selected to get respiration by testing 120 sets of experiment data using 700 filtering cases. As a result, 2nd order Bessel-filter that used band-pass cutoff frequency at 0.175~0.4Hz with second order was good at developing respiration signal. Respiration signal in time domain could be continuously analyzed by converting frequency domain using spectrum analysis. 24 seconds has been found to be optimal time duration of collecting PPG data for determining respiration. Therefore, this study was successful of getting not only heart activity but also respiration by only PPG. Minimal invasive measurement obtaining multi-bio information by one sensor can be expected to apply to U-Health Care and human computer interaction.