• Title/Summary/Keyword: health signal

Search Result 984, Processing Time 0.029 seconds

Pallidal Signal Intensities on T1-weighted MRI are Highly Observed in Advanced Liver Cirrhosis

  • Weon, Young-Cheol;Park, Neung-Hwa;Kim, Yang-Ho;Lee, Heun
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.5
    • /
    • pp.380-385
    • /
    • 2012
  • Background: Manganese (Mn) has been found to increase the signal intensity of the globus pallidus (GP) on T1-weighted magnetic resonance images (MRI). We performed this study in order to determine the features of liver disease that correlate with pallidal signal intensities. Methods: We assessed blood Mn levels and pallidal signals in T1-weighted MRI in 49 patients with liver cirrhosis and 23 healthy controls. Results: Increased signal intensity in the GP was observed in 30 of 49 (61.2%) patients with liver cirrhosis, with the pallidal index (PI) in patients with Child-Pugh classes B and C differing significantly from the PI in controls. Multiple linear regression analysis showed that blood Mn concentrations and Child-Pugh scores in cirrhotics were significantly associated with increased PI after controlling for other confounders (p<0.05 each). Conclusions: Pallidal signals on T1-weighted MRI are mainly observed in advanced liver cirrhosis. The present study suggests that advanced liver cirrhosis may be a human model for manganism.

Implementation and evaluation of the BCG measurement system for non-constrained health monitoring (무구속 건강모니터링을 위한 심탄도 계측 시스템 구현 및 평가)

  • Noh, Yun-Hong;Jeong, Do-Un
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.8-16
    • /
    • 2010
  • This research proposes measuring of BCG(ballistocardiogram) to monitor heart activities in a non-constrained environment, at home or work. Unlike with ECG, measuring BCG does not require the attachment of leads on the subject's body and allows signal measuring in a non-constrained state. It enables effective long-term monitoring of cardiac conditions. In this study a chair type BCG measurement system to continuous monitor the activity of the heart is implemented. The instrument consists of upper petal and ready for press of chair load cell sensor is attached to measure the change of the object's weight. In order to extract the output ballistic signal from the weight and force sensor signals. Beside the signal processing circuit for the digital conversion, the ballistic signal is detected using DAQ equipment. Signal processing algorithm including wavelet transforms for noise cancellation, template matching for normalization and peak detection in BCG is developed. ECG and BCG were concurrently measured to evaluate the performance of the system, and comparing the characteristics of the two signals verified the possibility of the system in non-constrained and nonconscious health monitoring.

Development of Signal Process Circuit for PSAPD Detector (위치민감형 광다이오드 검출기의 신호처리회로 개발과 적용)

  • Yoon, Do-Kun;Lee, Won-Ho
    • Journal of radiological science and technology
    • /
    • v.35 no.4
    • /
    • pp.315-319
    • /
    • 2012
  • The aim of this study was to develop a signal process circuit for a position sensitive avalanche photodiode detector. The circuit parts consisted of amplification, differential and peak/hold circuit. This research was the baseline to develop highly compact radiation detector. The signal was amplified by an amplification chip and its shape was changed in a differential circuit to minimize the pulse tailing. The peak/hold circuit detect the peak of the signal from the differential circuit and hold the amplitude of the peak for data acquisition. In order to test the intrinsic function of the circuit, the input signal was transmitted from a commercial pulse generator.

A Study on Monitoring of Bio-Signal for u-Health System (u-Health System을 위한 생체신호 모니터링에 관한 연구)

  • Han, Young-Hwan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.3
    • /
    • pp.9-15
    • /
    • 2011
  • U-healthcare system has an aim to provide reliable and fast medical services for patient regardless of time and space by transmitting to doctors a large quantity of vital signs collected from sensor networks. Existing u-healthcare systems can merely monitoring patients' health status. In this paper, we describe the implementation and validation of a prototype of a u-health monitoring system based on a wireless sensor network. This system is easy to derive physiologically meaningful results by analyzing rapidly vital signs. The monitoring system sends only the abnormal data of examinee to the service provider. This technique can reduces the wireless data packet overload between a monitoring part and service provider. The real-time bio-signal monitoring system makes possible to implement u-health services and improving efficiency of medical services.

Dose Motor Inhibition Response Training Using Stop-signal Paradigm Influence Execution and Stop Performance?

  • Son, Sung Min
    • The Journal of Korean Physical Therapy
    • /
    • v.32 no.2
    • /
    • pp.70-74
    • /
    • 2020
  • Purpose: This study examined whether 1) the motor inhibition response as cognitive-behavioral component is learning though a stop signal task using stop-signal paradigm, and 2) whether there is a difference in the learning degree according to imagery training and actual practice training. Methods: Twenty young adults (males: 9, females: 11) volunteered to participate in this study, and were divided randomly into motor imagery training (IT, n=10) and practice training (PT, n=10) groups. The PT group performed an actual practice stop-signal task, while the IT group performed imagery training, which showed a stop-signal task on a monitor of a personal computer. The non-signal reaction time and stop-signal reaction time of both groups were assessed during the stop-signal task. Results: In the non-signal reaction time, there were no significant intra-group and inter-group differences between pre- and post-intervention in both groups (p>0.05). The stop-signal reaction time showed a significant difference in the PT group in the intra-group analysis (p<0.05). On the other hand, there was no significant intra-group difference in the IT group and inter-group difference between pre- and post-intervention (p>0.05). Conclusion: These results showed that the motor inhibition response could be learned through a stop-signal task. Moreover, these findings suggest that actual practice is a more effective method for learning the motor inhibition response.

Signal-Based Structural Health Monitoring Methods for Caisson-Type Breakwaters (케이슨식 방파제의 신호기반 구조건전성 모니터링 기법)

  • 이용환;김주영;박재형;김정태
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.10a
    • /
    • pp.451-458
    • /
    • 2004
  • The caisson-type breakwaters have been widely used in the area of harbor construction. Because of the importance of the breakwaters, structural health monitoring in the breakwaters by using appropriate methods is of great needs. In this study, a caisson-type breakwater that has fatigue cracks due to wave-impact is investigated. First, a signal-based structural health monitoring method is proposed for the breakwaters structures. Excitation and sensor systems are designed on finite element model and monitoring categories are also selected. Structural health monitoring was realized by using measured dynamic response signals and analyzed information.

  • PDF

Signal Analysis According to the Position of the ECG Sensor Electrode in Healthcare Backpack (헬스케어 가방의 ECG 센서 전극 위치에 따른 신호 분석)

  • Lee, Hyeon-Seok;Chung, Wan-Young
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.402-408
    • /
    • 2014
  • Heart rate is one of the most important signal to monitor the health condition of the patient or exerciser. Various wearable devices have been developed for the continuous monitoring of ECG signal from human body during exercise. Among these, ECG chest belt has been widely used. However wearing chest belt with ECG sensor is uncomfortable in normal life due to the electrode contact between metal electrodes of ECG sensor and skin of the human body. So we develop the royal healthcare backpack that can measure ECG signal without skin contact by using capacitor-type ECG sensor. The position of the measurement point is critical to collect a clear ECG signal in the capacitive ECG measurement from backpack. Various tests were conducted to find the optimal ECG measurement position which has less noise and could get strong and clear ECG signal during exercise, walking, hiking, mountain climbing and cycling.

Computer Application to ECG Signal Processing

  • Okajima, Mitsuharu
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.13-14
    • /
    • 1985
  • We have developed a microprogramir!able signal processor for real-time ultrasonic signal processing. Processing speed was increased by the parallelism in horizontal microprogram using 104bits microcode and the Pipelined architecture. Control unit of the signal processor was designed by microprogrammed architec- ture and writable control store (WCS) which was interfaced with host computer, APPLE- ll . This enables the processor to develop and simulate various digital signal processing algorithms. The performance of the processor was evaluated by the Fast Fourier Transform (FFT) program. The execution time to perform 16 bit 1024 points complex FF7, radix-2 DIT algorithm, was about 175 msec with IMHz master Clock. We can use this processor to Bevelop more efficient signal processing algorithms on the biological signal processing.

  • PDF

Effect of Number of Measurement Points on Accuracy of Muscle T2 Calculations

  • Tawara, Noriyuki;Nishiyama, Atsushi
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.4
    • /
    • pp.207-214
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the effect of the number of measurement points on the calculation of transverse relaxation time (T2) with a focus on muscle T2. Materials and Methods: This study assumed that muscle T2 was comprised of a single component. Two phantom types were measured, 1 each for long ("phantom") and short T2 ("polyvinyl alcohol gel"). Right calf muscle T2 measurements were conducted in 9 healthy male volunteers using multiple-spin-echo magnetic resonance imaging. For phantoms and muscle (medial gastrocnemius), 5 regions of interests were selected. All region of interest values were expressed as the mean ${\pm}$ standard deviation. The T2 effective signal-ratio characteristics were used as an index to evaluate the magnetic resonance image quality for the calculation of T2 from T2-weighted images. The T2 accuracy was evaluated to determine the T2 reproducibility and the goodness-of-fit from the probability Q. Results: For the phantom and polyvinyl alcohol gel, the standard deviation of the magnetic resonance image signal at each echo time was narrow and mono-exponential, which caused large variations in the muscle T2 decay curves. The T2 effective signal-ratio change varied with T2, with the greatest decreases apparent for a short T2. There were no significant differences in T2 reproducibility when > 3 measurement points were used. There were no significant differences in goodness-of-fit when > 6 measurement points were used. Although the measurement point evaluations were stable when > 3 measurement points were used, calculation of T2 using 4 measurement points had the highest accuracy according to the goodness-of-fit. Even if the number of measurement points was increased, there was little improvement in the probability Q. Conclusion: Four measurement points gave excellent reproducibility and goodness-of-fit when muscle T2 was considered mono-exponential.

A review on vibration-based structural pipeline health monitoring method for seismic response (지진 재해 대응을 위한 진동 기반 구조적 관로 상태 감시 시스템에 대한 고찰)

  • Shin, Dong-Hyup;Lee, Jeung-Hoon;Jang, Yongsun;Jung, Donghwi;Park, Hee-Deung;Ahn, Chang-Hoon;Byun, Yuck-Kun;Kim, Young-Jun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.5
    • /
    • pp.335-349
    • /
    • 2021
  • As the frequency of seismic disasters in Korea has increased rapidly since 2016, interest in systematic maintenance and crisis response technologies for structures has been increasing. A data-based leading management system of Lifeline facilities is important for rapid disaster response. In particular, the water supply network, one of the major Lifeline facilities, must be operated by a systematic maintenance and emergency response system for stable water supply. As one of the methods for this, the importance of the structural health monitoring(SHM) technology has emerged as the recent continuous development of sensor and signal processing technology. Among the various types of SHM, because all machines generate vibration, research and application on the efficiency of a vibration-based SHM are expanding. This paper reviews a vibration-based pipeline SHM system for seismic disaster response of water supply pipelines including types of vibration sensors, the current status of vibration signal processing technology and domestic major research on structural pipeline health monitoring, additionally with application plan for existing pipeline operation system.