• 제목/요약/키워드: head-part measurement

검색결과 56건 처리시간 0.033초

간호 관리 능력 개발을 위한 교육 연구 (Needs on Management Development Program for Head Nurse)

  • 박정선
    • 가정간호학회지
    • /
    • 제5권
    • /
    • pp.84-99
    • /
    • 1998
  • The objectives of this study are to identify the actual educational contents of management for head nurse and to propose the educational subjects according to identity the needs of head, charge, and staff nurses. The subjects were investigated the actual Management Development Programs and educational needs of head nurses and prospective nurse manager(charge nurse, staff nurse with a lot of clinical experiences) in general hospitals. The tools were composed of two questionnaires: One was developed from the literature review for making items to measure actual situation. The other was revised Katz's model for measurement of educational needs. The first respondents of actual situation were 27 general hospitals with over 400 beds in Seoul and the second respondents were 89 head nurses, 67 charge nurses and 136 nurses at 3 hospitals by convenient sampling out of 27 general hospitals. Data were collected by telephone interview, mail questionnaire and visiting from 7th of October through 30th of November in 1997. In data analysis, general characteristics of the respondents and actual status of Management Development Programs were analyzed by frequency and percentage. Educational needs according to general characteristics were analyzed by ANOVA The results were as follows: 1. Actual situation of Management Development Program 1) Seven hospitals(26%) had Management Development Program for prospective managers and 14 hospitals (52%) for head nurses. 2) Education Department existed in 14 hospitals (52%). 3) One hospital(4%) had top level managers took part in the Management Development. 4) Two hospitals selected head nurse, who had finished courses of Management Development. Eight hospitals(30%) assessed educational needs. The assessment tools consisted of making a question via questionnaire(75%), determining at department meeting(12%) and interview(13%). 5) Educational programs had 3 types: 10 lecture type, 7 discussion type and 4 role play type programs. 6) One hospital evaluated the change of learner's attitude. 7) Four hospitals scored educational point, but that was measured only by attending. 8) Actual Management Development Programs were as follows. parenthesis indicates the number of hospitals. (1) Management Development Programs for Prospective manager. Role perception of Middle level Manager (1) . Role reconstruction of Nurse Manager (1). Workshop for Charge Nurse (1). Nursing Delivery System and Nursing Process (1). Communication (1). Motivation (1) (2) Management Development Programs for Head nurse.. Head nurse's Role (5). Administrative Work (7). Service Education (4). Prevention and Countermeasure of Nursing Incidence (3). Appraisal (3) 2. The results of needs on Management Development subject 1) The educational needs of all respondents on 3 skill domains showed positive agreement to strongly positive agreement. 2) High priority(more than 4.5) items were 12 of 24 Human skill items(50%), 1 of 6 Technical skill items(16%), and 2 of 13 Conceptual skill items (15%). 3) Out of high priority items, 8 items were instituted. 4) All respondents showed high needs on 3 skill domains regardless of 3 positions (head nurse, charge nurse, and nurse). Educational needs of Human skill domain, according to position were 108. S, 108.7, 106.8 (mean score = 72) , needs of Technical skill domain were 26.5, 26.6, 26.I(mean score=18), and needs of Conceptual skill domains were 56.9,56.7, 55.1(mean score=39). 5) Needs of 3 skill domains according to clinical career showed significant difference. Out of respondents, nurses with career of over 16years showed lowest degree of needs in Human skill domains(F=4.47, P=.004) and Conceptual skill domain(F=2.93, P=.034). 6) Educational needs according to educational background were not significant difference. But out of respondents, nurses educated at 3-year junior college relatively showed lowest needs in all of the 3 skill domains. With the above-mentioned findings, further study is necessary for generalization of this study at hospitals with different bed size and location. Also it is needed to study about management skill of nurse and charge nurse, and effective educational method.

  • PDF

용접 형상 측정용 시각 센서 모듈 개발 (Development of Vision Sensor Module for the Measurement of Welding Profile)

  • 김창현;최태용;이주장;서정;박경택;강회신
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.285-286
    • /
    • 2006
  • The essential tasks to operate the welding robot are the acquisition of the position and/or shape of the parent metal. For the seam tracking or the robot automation, many kinds of contact and non-contact sensors are used. Recently, the vision sensor is most popular. In this paper, the development of the system which measures the profile of the welding part is described. The total system will be assembled into a compact module which can be attached to the head of welding robot system. This system uses the line-type structured laser diode and the vision sensor It implemented Direct Linear Transformation (DLT) for the camera calibration as well as radial distortion correction. The three dimensional shape of the parent metal is obtained after simple linear transformation and therefore, the system operates in real time. Some experiments are carried out to evaluate the performance of the developed system.

  • PDF

PET-CT 검사 환자의 외부 방사선량률 변화 (Changes in External Radiation Dose Rate for PET-CT Test Patients)

  • 김수진;한은옥
    • Journal of Radiation Protection and Research
    • /
    • 제37권2호
    • /
    • pp.103-107
    • /
    • 2012
  • PET-CT 검사 환자의 피폭선량 감소를 위한 기초자료 제공의 일환으로 PET-CT 검사 환자의 방사선량률의 변화를 분석하고자 하였다. PET-CT 검사 환자의 방사선량률을 측정한 결과 이론과 같이 방사성의약품이 투여된 환자로부터 거리가 멀수록, 시간이 지날수록 방사선량률은 감소되는 것을 볼 수 있었다. 특히 신체부위에 따라서는 방사성의약품 정맥 주사 즉시인 약 4.17분에서는 흉부, PET-CT 검사 전 배뇨 후인 약 77.47분 이후부터는 두부가 가장 높게 나타났다. 일반화되어 있는 정보와 같이 PET-CT 검사 환자로부터 받는 방사선 피폭량을 감소시키기 위해서는 보호자나 방사선작업종사자가 환자로부터 거리를 멀리하거나 방사능이 감소된 이후의 시간부터 접촉하는 것이 바람직하다. 불가피한 접촉이 필요하다면 가능한 거리는 200 cm이상을 확보하는 것이 바람직하다. 또한 초기에는 흉부, 방사성의약품 투여 후 약 77분 이후부터는 두부에 방사선량률이 높기 때문에 환자 신체적 특징을 고려한 접촉도 함께 이루어진다면 최적화 달성에 도움이 될 것이라고 보여 진다. 본 연구에서 도출된 PET-CT 검사 환자의 거리, 시간, 신체부위에 따른 방사선량률 변화를 알 수 있다는 점에서 연구에 의의가 있다고 본다. 향후 연구에서는 본 연구에서 도출된 결과를 바탕으로 환자 개인특성에 따른 방사선량률의 변화 차이를 분석하여 환자, 보호자, 종사자의 피폭선량 감소에 활용할 수 있도록 지속적인 연구가 수행되는 것이 필요하다고 본다.

UAS 영상 및 지상 LiDAR 조합한 3D 수치모형 기반 비탈면 앵커의 손상인자 분석에 관한 연구 (A Study on Damage factor Analysis of Slope Anchor based on 3D Numerical Model Combining UAS Image and Terrestrial LiDAR)

  • 이철희;이종현;김달주;강준오;권영훈
    • 한국지반공학회논문집
    • /
    • 제38권7호
    • /
    • pp.5-24
    • /
    • 2022
  • 현행 비탈면 앵커공법의 보강성능평가는 앵커 두부와 지반밀착도, 앵커 두부의 균열 및 파손에 대해서 정성적으로 성능을 평가하고 있다. 이로 인해 성능저하 상태 점검을 위한 정량적 데이터베이스화와 이를 이용한 시간이력 관리는 어려운 실정이다. 이에 본 연구에서는 비탈면에 설치된 앵커공법의 정량적 유지관리에 활용하기 위하여 UAS 영상과 지상 LiDAR의 사각지대를 보완하기 위한 SfM기반의 조합 3차원 수치모형을 구현하여 손상인자의 수치데이터를 검출하였다. 비탈면과 같은 수직구조물에서 상대적으로 높은 z 좌표 오차를 갖는 UAS 3차원 수치모형에서 사각지대 데이터 공백을 상호 보완하기 위하여 지상 LiDAR 스캔 데이터를 조합하였고 z 좌표 정확도의 향상을 확인하였다. 비탈면에 설치된 10공의 앵커에 임의로 손상을 발생시킨 후에 3차원 수치모형을 구축하였고 정사투영을 통해 균열, 파손, 회전변위와 지반 밀착도에 대한 수치 값을 검출하였다. 8K 해상도로 균열 실측값과 비교시 ±0.05mm의 오차범위에서 0.3mm 미만의 균열 검출이 가능하였다. 앵커 두부의 최대 파손 면적은 설계대비 3% 이내로 발생된 것을 확인하였고, 파손부의 체적 또한 검출하였다. 특히 z 좌표 데이터가 중요한 지반밀착도의 경우 UAS 3차원 수치모형에서는 사각지대로 인한 데이터 공백으로 측정이 불가능하였지만 지상 LiDAR를 조합할 경우 앵커 저면과 지반의 불규칙한 표면에서 표고차 확인이 가능하여 임의의 20개 지점의 평균 표고차를 지반밀착도로 도출하였다. 또한, 앵커 두부의 1° 미만의 회전각과 이동 변위 값도 검출하였다. 이에 본 연구에서 구축한 3차원 수치모형에서 앵커 손상인자의 정량적 데이터 추출이 가능하였고, 이를 데이터베이스화 한다면 정량적 평가지표의 기초자료로써 활용이 가능할 것으로 판단된다.

3차원 모델링을 이용한 대퇴 전염각의 측정 (A NEW MEASUREMENT METHOD OF FEMORAL ANTEVERSION BASED ON THREE DIMENSIONAL MODELING)

  • 김준식;박희정;최광수;최귀원;김선일
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.141-144
    • /
    • 1997
  • Femoral neck anteversion is the angle between the neck and the knee axis projected on a plane perpendicular to the longitudinal axis. Conventional methods that use cross-sectional Computed Tomography(CT) images to estimate femoral anteversion have several problems because of the complex 3D structure of the femur. These are the ambiguity of defining the longitudinal axis, the femoral neck axis and condylar line, and the dependence on patient positioning. Especially the femoral neck axis that is known as a major source of error is hard to determine from a single or multiple 2D transverse images. So we developed a new method for measuring femoral anteversion by 3D modeling method. In this method, femoral head is modeled as a sphere. The center of femoral neck is the mid-point of the 2D reconstructed oblique image in the femoral neck part. Then neck axis is a line connecting foregoing two centers. We model the longitude of femur as a cylinder, and the long axis is defined from the fitted cylinder. The knee axis which is tangent to the back of the femoral condyles is easily determined by table-top method. By the definition of femoral anteversion, the femoral anteversion is easily calculated from this model.

  • PDF

Compensatory change of opposite hippocampus after temporal lobe surgery in patients with temporal lobe epilepsy Evidence from single-voxel proton MR spectroscopy

  • Lee, Sang-Hyun;Chang, Kee-Hyun;Chung, Chun-Kee;Song, In-Chan;Han, Moon-Hee
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2001년도 제6차 학술대회 초록집
    • /
    • pp.172-172
    • /
    • 2001
  • Purpose: To evaluate compensatory change of opposite hippocampus after temporal lobe surgery in th patient with temporal lobe epilepsy by using single-voxel proton MR spectroscopy. Method: Eighteen patients with intractable temporal lobe epilepsy (TLE) whose MR diagnos was unilateral hippocampal sclerosis (n=11) or localized unilateral anterior temporal lobe lesio (n=7) and who underwent anterior temporal lobectomy were included in the study. Singl proton MRS of opposite hippocampus was carried out on the same day or within 1 week af MR imaging before temporal lobe surgery and after over 1-year post-surgical follow-u Single voxel proton MRS were acquired using GE signa 1.5T scanner and spectrosco system (TR, 1500-2, 000: TE, 136-144). Region of interest (ROI) was placed in a simitar position for all examination to cover the medial temporal lobes including most of the head an body of hippocampus and a part of amygdala, the parahippocampal gyrus. The MR spectr were evaluated with a focus on the metabolite ratio of N-acetylaspartate (NAA choline-containing phospholipids (Cho), creatine (Cr). The metabolite ratios of NAA/ Cr were calculated from the relative peak height measurement. We evaluated change of th intensity ratio NAA/Cr between before and after surgery, to simplify quantification acro patients, because observed decreases in the ratio of NAA/Cr can be interpreted in terms o neuronal or axonal damage.

  • PDF

속초 신흥사 목조지장보살삼존상의 비파괴 손상도 진단 (Nondestructive Deterioration Diagnosis for Wooden Ksitigarbha Triad Statues of Shinhungsa Temple in Sokcho, Korea)

  • 한나라;이찬희;이정은
    • 보존과학회지
    • /
    • 제29권2호
    • /
    • pp.93-102
    • /
    • 2013
  • 속초 신흥사 목조지장보살삼존상(보물 제1749호)은 신흥사 명부전에 안치되어 있다. 이 삼존상에는 부분적으로 균열, 박락 등의 물리적 손상과 안료 변색, 균류 서식 등의 화학적 및 생물학적 손상이 발생하였다. 이 연구에서는 삼존상의 손상도 평가 및 보존계획을 수립하기 위해 손상지도 작성, 초음파 측정, X-선 및 내시경 촬영 등의 비파괴 정밀진단을 수행하였다. 이 결과, 지장보살에서는 개금층 박락이 관찰되며 각종 오염물이 불상표면에 고착되어 있다. 무독귀왕은 누수에 의한 안료변색이 심하다. 도명존자는 노출된 목부재에서 곤충의 서식흔적이 확인되었으며, 내부에서는 벌집이 관찰되었다. 따라서 이 손상도 진단 결과를 바탕으로 삼존상의 원형을 보존하기 위한 보수가 필요한 것으로 판단된다.

직독식 기기를 이용한 양돈작업자의 신체부위별 PM10 노출 특성 비교 연구 (A Comparison of PM10 Exposure Characteristics of Swine Farmers by Body Parts using Direct-reading Instrument)

  • 신소정;김효철;김경란;서민태;박수인;김경민;김경수
    • 한국산업보건학회지
    • /
    • 제29권2호
    • /
    • pp.159-166
    • /
    • 2019
  • Objectives: The purpose of this study was to evaluate the personal exposure to $PM_{10}$ by body parts for the development of dust monitoring wearable device for swine farmers. Methods: Tasks were classified by using motion pictures taken by action cameras attached to swine farmers. Concentrations of $PM_{10}$ were measured by attaching direct-reading instruments at the head, neck and waist of worker. Differences of $PM_{10}$ exposure between body parts were analyzed with linear regression. Results: We identified three tasks(vaccination, moving pigs, and manure treatment). $PM_{10}$ concentration during vaccination was the highest among the tasks, and the body part showing the highest concentration of $PM_{10}$ was the waist regardless of task. In all tasks, the closer distance between the body parts, the higher were the R-squared values(vaccination 0.4221, moving pigs 0.6990, and manure treatment 0.2164). Conclusions: We presumed that $PM_{10}$ concentrations were affected by the parts of the body in which they were measured. In order to develop swine farmer's wearable device for monitoring dust concentration in air, the determination of the positions of monitoring sensor to ensure accurate measurement is essential. Considering the results of this study, wearable sensor should be positioned at the waist.

정모 및 측모 두부 방사선 규격사진을 이용한 3차원 계측 프로그램의 개발 -1. 단일 방사선원으로 촬영된 두부 방사선사진의 두부 위치 보정을 이용한 3차원 좌표의 산출- (DEVELOPMENT OF THREE DIMENSIONAL MEASURING PROGRAM WITH FRONTAL AND LATERAL CEPHALOMETRIC RADIOGRAPHS -PART 1. COMPUTATION OF THE THREE-DIMENSIONAL COORDINATES BY COMPENSATION OF THE ERROR OF THE HEAD POSITION IN ORDINARY NON-BIPLANAR CEPHALOSTAT-)

  • 이근호;이상한;장현중;권대근
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제27권3호
    • /
    • pp.214-220
    • /
    • 2001
  • 안면비대칭이나 반안면왜소증과 같은 구강악안면영역의 기형에 대한 진단 및 치료 계획 수립을 위하여 두개 악안면 구조물에 대한 총체적인 접근이 필요하다. 이에 두부 규격 방사선 사진을 이용한 3차원 두부 계측 방사선 시스템의 임상적 적용이 계속 시도되었으나 주로 두 방향의 방사선원으로부터 동시에 얻어진 standard Broadbent-Bolton cephalometer에 한정되어 있었다. 이에 본 연구에서는 단일방사선원에 의하여 촬영된 한 쌍의 정모 및 측모두부방사선 사진으로 정확한 3차원 좌표치를 얻을 수 있는 방법을 개발하고 이렇게 얻어진 3차원 좌표치의 정확도와 재현성을 검증하여 다음과 같은 결과를 얻었다. 1. 정모, 측모 두부 방사선 사진을 동시에 촬영하지 않음으로 인하여 생기는 오차를 보정해주는 수학적인 공식을 산출하고 이 공식에 의거하여 정모 두부 방사선 사진에 기준한 측모 두부 방사선 계측 사진의 위치 결정시의 오차를 건조 두개골을 이용하여 검증한 결과 1차와 2차 측정시 각각 평균 $0.46{\pm}1.21^{\circ}, $0.33{\pm}0.90^{\circ}로 나타났다. 2. 단일 방사선원으로부터 3차원 계측점의 좌표값을 얻을때의 재현성을 파악하기 위한 임상적 계측 결과 1, 2차측정간의 오차가 절대값 평균 0.54mm ($-2.99{\sim}2.26mm$)로 나타났으며 이때 계측점 인식의 오차는 평균 $1.2{\pm}1.6mm$ 였다. 위와 같은 결과를 종합하여 볼 때 정모 두부 방사선 사진에 의거한 측모 두부 방사선 계측사진의 위치를 결정한 후 두부위치 보정공식을 도입하면 임상적으로 충분히 재현성 있는 3차원 계측을 할 수 있다는 것을 알 수 있었다.을 증가시킨다. - PKC pathway는 MAPK pathway를 경유하여 Runx2의 전사 활성을 조절한다.있을 것으로 사료된다.대구치의 원심경사는 필연적으로 일어나며, 이를 최소화하기 위한 노력이 계속되어야 할 것으로 사료된다.글래스 아이오노머 시멘트 사이에는 유의한 차이가 없었다.착제의 종류에 따른 전단결합강도를 비교한 결과, 영구치와 유치 모두에서 Clearfil SE Bond를 사용한 군의 전단결합강도가 가장 높았으며 AQ Bond를 사용한 군의 전단결합강도가 가장 낮았다.본에서 III군에 비해 크기가 큰 기포가 더욱 많이 관찰되었다.e의 약동학은 cimetidine에 의해 유의한 차이를 보였으며 CYP1A2유전자형에 따른 영향은 관찰할 수 없었다. CYP1A2유전자형에 따른 생체내 대사능을 관찰하는 실험이 향후 이루어 져야 할 것으로 사료된다.san film보다 큰 수증기 투과도를 보였다.적으로 유의한 차이를 보이지 않았다.y tissue layer thinning은 3 군모두에서 관찰되었고 항암 3 일군이 가장 심하게 나타났다. 이상의 실험결과를 보면 술전 항암제투여가 초기에 시행한 경우에는 조직의 치유에 초기 5 일정도까지는 영향을 미치나 7 일이 지나면 정상범주로 회복함을 알수 있었고 실험결과 항암제 투여후 3 일째 피판 형성한 군에서 피판치유가 늦어진 것으로 관찰되어 인체에서 항암 투여후 수술시기는 인체면역계가 회복하는 시기를 3주이상 경과후 적어도 4주째 수술시기를 정하는 것이 유리하리라 생각되었다.한 복합레진은 개발의 초기단계이며, 물성의 증가를 위한 연구가 필요할 것으로 사료된다.또 다른 약물인 glycyrrhetinic acid($100{\mu}M$)도 CCh 자극으로 인한 타액분비를 억제하였다. 이상의 결과로 미루어

  • PDF

전신 PET/CT 검사에서 환자의 팔 위치에 따른 CT 유효선량의 비교 연구 (A Comparative Study on the CT Effective Dose by the Position of Patient's Arm)

  • 성지혜;박순기;김정선;박승용;정우영
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.44-49
    • /
    • 2012
  • 최근 영상 의학 분야의 발전으로 인한 보편화와 일본의 후쿠시마 원전사태가 일어나면서 방사선 노출에 대한 대중들의 관심이 높아지게 되었다. 이러한 방사선 피폭에 대한 대중들의 관심으로 현재 거의 대부분의 PET/CT검사에서 사용되고 있는 AEC (Automatic Exposure Control) 시스템은 환자의 피폭선량 감소를 위해 피사체의 두께에 따라 최적의 관전류를 조사한다. 또한, 서울아산병원에서는 전신 PET/CT 검사 시선속 경화 인공물(Beam hardening artifact)의 발생을 줄이기 위해 환자의 팔을 머리 위로 올리고 검사를 시행하고 있다. 본 연구에서는 전신 PET/CT검사 시 환자의 팔 위치에 따라 AEC 시스템을 적용한 CT 유효선량의 차이를 비교하고자 한다. 2008년 12월부터 2011년 7월까지 서울아산병원 핵의학과를 내원하여 동일 장비에서 팔을 올렸을 경우와 팔을 내렸을 경우의 전신 18F-FDG PET/CT 검사를 시행한 환자 45명을 연구의 대상으로 하였고, 실험 장비는 Biograph Truepoint 40 (Bio 40), Biograph Sensation 16 (Bio 16), Discovery STe 8 (DSTe 8)을 사용하였다. 각 장비당 15명의 동일 환자를 대상으로, 팔을 올리고 검사하였을 경우와 팔을 내리고 검사하였을 경우의 CT 유효선량을 산출하여 비교 분석하였다. CT 유효선량의 측정 방법은 ImPACT v1.0 프로그램을 사용하였다. 이 연구를 통해 팔을 올리고 검사한 경우에 팔을 내리고 검사한 경우보다 총 15.2%의 환자 유효선량이 감소된 것을 확인할 수 있었다. 전신 PET/CT 검사 시 환자의 팔을 올린 자세는 선속 경화 인공물 발생을 줄이고, 영상의 질을 향상시킬 수 있을 것이라 생각된다.

  • PDF