• Title/Summary/Keyword: head direction

Search Result 530, Processing Time 0.021 seconds

Rotational Characteristics of Target Registration Error for Contour-based Registration in Neuronavigation System: A Phantom Study (뉴로내비게이션 시스템 표면정합에 대한 병변 정합 오차의 회전적 특성 분석: 팬텀 연구)

  • Park, Hyun-Joon;Mun, Joung Hwan;Yoo, Hakje;Shin, Ki-Young;Sim, Taeyong
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.2
    • /
    • pp.68-74
    • /
    • 2016
  • In this study, we investigated the rotational characteristics which were comprised of directionality and linearity of target registration error (TRE) as a study in advance to enhance the accuracy of contour-based registration in neuronavigation. For the experiment, two rigid head phantoms that have different faces with specially designed target frame fixed inside of the phantoms were used. Three-dimensional coordinates of facial surface point cloud and target point of the phantoms were acquired using computed tomography (CT) and 3D scanner. Iterative closest point (ICP) method was used for registration of two different point cloud and the directionality and linearity of TRE in overall head were calculated by using 3D position of targets after registration. As a result, it was represented that TRE had consistent direction in overall head region and was increased in linear fashion as distance from facial surface, but did not show high linearity. These results indicated that it is possible for decrease TRE by controlling orientation of facial surface point cloud acquired from scanner, and the prediction of TRE from surface registration error can decrease the registration accuracy in lesion. In the further studies, we have to develop the contour-based registration method for improvement of accuracy by considering rotational characteristics of TRE.

Development and Achievement of Head-Up Display in Public Transit for Reducing Accidents (버스 교통사고 감소를 위한 대중교통 HUD 기술 개발과 성과)

  • Roh, Chang-Gyun;Park, Bum Jin;Kang, Weon-Eui
    • Journal of Korean Society of Transportation
    • /
    • v.32 no.5
    • /
    • pp.513-521
    • /
    • 2014
  • Korea's traffic congestion costs including other social costs due to accidents, environmental pollution and increased demand is increasing every year. In this regard, direction of government policy was geared toward suppression of vehicle demand and activation of public transportation, which is determined to be the best solution with limited supply of infrastructure such as road facilities. This study aims to implement public transport bus-only Head-Up Display (hereafter called HUD) technology which displays public transport information required for a bus driver on the front glass of a bus. The public transport bus-only HUD not only prevents gaze dispersion of bus drivers but also helps to reduce the heavy workload of bus drivers by providing information required for driving. Ultimately, the final research purpose is a reduction of bus traffic accidents by 50% caused by negligence in keeping eyes forward or sideways.

Positional change of the condylar heads after wearing complete denture on dental cone beam CT (치과용 콘빔 CT영상에서 총의치 장착 후 하악과두의 위치변화)

  • Lee, Bong-Ho;Kim, Jae-Duk;Chung, Chae-Heon
    • Imaging Science in Dentistry
    • /
    • v.38 no.1
    • /
    • pp.23-27
    • /
    • 2008
  • Purpose: The aim of this study was to evaluate the change in the position of the mandibular condyle within articular fossa by a CBCT after wearing complete denture (CD). Materials and Methods: CBCT of 34 temporomandibular joints were taken from 9 male and 8 female patients with CB $Mercuray^{TM}$ (Hitachi, Japan) before and after wearing a CD for rehabilitation. Position of mandibular condyle within articular fossa at centric occlusion was evaluated with $Vimplant2.0^{TM}$ (CyberMed, Korea) on the central parasagittal view and curved panoramic coronal view of the condylar head. A statistical evaluation was done with SPSS. Results: The range of anteroposterior positional rate (AP) of condylar head within articular fossa was -16-5 and -10-12 respectively on the right and left sides. Before wearing CD, the AP rate showed discrepancy between right and left sides (p<0.05). After wearing CD, both condyles showed a tendency to decrease in posterior condylar position (right side; p<0.05). The average discrepancy between right and left side in mediolateral positional rate (MD) was 15.5 and 4.5 respectively before and after wearing CD. The improvement was observed in mediolateral relationship of both condylar heads after wearing CD (p< 0.01). Before wearing CD, the average horizontal angle of long axis of condylar head was $79.6{\pm}2.7^{\circ}\;and\;80.1{\pm}5.7^{\circ}$ respectively on the right and left sides. After wearing CD, both condyles were rotated in the same direction in average on axial plane. Conclusion: We observed with CBCT the significant clinical evidence in case of positional change of mandibular condyle after wearing complete denture.

  • PDF

A Study of the Shot Differences Among Each Clubs and the Weight Shift Patterns from Back Swing Top to the Impact during the Golf Swing (골프스윙시 각 클럽간의 샷 분석 및 백스윙톱과 임팩트시의 체중이동분석)

  • Kim, Chang-Wook
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.2
    • /
    • pp.287-296
    • /
    • 2009
  • This is written to present basic shot information among iron clubs and information of weight shift, because previous study conducted on all clubs was rut enough. This article is about shot analysis of iron club 3,4,5,6,7,8,9 and weight movement, conducted on four skilled golf players and four students who major in golf and are less than three years. The analysis of long and short irons showed statistically meaningful different results for all the participants but iron clubs of 3,4,5 didn't in head speed and ball speed. The skilled group showed better results in head speed, ball speed and direction, Launch angle than the unskilled group. In weight shift movement analysis, the unskilled group moved, on back swing top, their more weight(65.36%) but the skilled group was on their left foot (70.21%)when clubs were on impact moment. It shows that the skilled group put on power more efficiently by moving weight.

Analysis of SAR on Human Head Caused by Antenna of PCS Handheld Telephone (PCS 전화기의 안테나에 의해 인체 두부에 유기되는 SAR 분석)

  • Park, Ju-Derk;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.10 no.7
    • /
    • pp.985-997
    • /
    • 1999
  • In this paper, the detection of 1 g and 10 g averaged SAR on human head caused by PCS handheld phones is analyzed and discussed. Conventional monopole antenna and planar structured PIFA are used in the computational model to apply to the antennas mounted on handheld phone. These antennas are designed to operate in the near of frequency 1.8 GHz, human head model is sampled to have cell size 1.5 mm and sloped to front direction by 30$^{\circ}$. It is found that, when monopole antenna is applied, 1 g averaged SAR is 1.4 W/kg, 10 g averaged SAR is 0.7 W/kg, when PIFA is applied, for each case, SARs are 1.143 W/kg, 0.4866 W/kg. While the radiation pattern of the monopole antenna is symmetrical, that of planar structured antenna is asymmetrical and SAR caused by PIFA is less than SAR by the monopole antenna. The radiation efficiency of PIFA is 62.6%, which is higher than that of monopole, 53%.

  • PDF

Performance Evaluation of an Auto Sampling and Filtering Unit of Substrate Solution using a Diaphragm Pump (소형 판막 펌프를 이용한 기질용액 채취 및 여과 자동화 장치의 성능검증)

  • Song, D.B.;Jung, H.S.;Lee, S.K.;Jung, D.H.;Park, S.W.
    • Journal of Biosystems Engineering
    • /
    • v.32 no.4
    • /
    • pp.263-268
    • /
    • 2007
  • An auto sampling and filtering unit was developed for monitoring automation of a fermentation process and its performance was evaluated. The automatic sampling and filtering unit was constructed with a glass filter, a diaphragm suction pump, and a flow direction change valve. To evaluate operating stability, delivery volumes of the suction pump were measured according to the experimental conditions of cellulose powder, pore size of the glass filter and suction head of the pump. The developed unit could deliver the sample solution under any experimental conditions except the filter pore size of $16{\mu}m$ and the suction head of 20cm. In case of the suction head of 30cm, the pump could not deliver the sample solution at all. Concentrations of the sample solutions were converged on those of the standard glucose solution after 8 minutes from the initial sampling time. The relative error of concentration between the sample and the standard solution showed 3.8, 4.8, 7.0% for the 1, 3, 5% contents of cellulose powder, respectively.

A study on the simplification of HRTF within high frequency region (고역 주파수 영역에서 HRTF의 간략화에 관한 연구)

  • Lee, Chai-Bong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.12 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • In this study, we investigated the effect of the simplification for high frequency region in Head-Related Transfer Function(HRTF) on the sound localization. For this purpose, HRTF was measured and analyzed. The result in the HRTF frequency characteristic of the back sound source showed that the decrease revel of high frequency was smaller than that of low frequency region, which means the possibility of simplification in the high frequency region. Simplification was performed by flattening of the high frequency amplitude characteristics with the insertion of the low-pass filter, whose cutoff frequency is given by boundary frequency. Auditory experiments were performed to evaluate the simplified HRTF. The result showed that direction perception was not influenced by the simplification of the frequency characteristics of HRTF for the error of sound localization. The rate of confusion for the front and back was not affected by the simplification of the frequency characteristics over 8kHz of HRTF. Finally, we made it clear that the sound localization was not affected by the simplification of frequency characteristics of HRTF over 8kHz.

Sonographic Findings of Second Branchial Cleft Cysts; Variable Appearances and Helpful Diagnostic Findings (제2새열 낭종의 초음파 소견;다양한 소견들과 진단에 도움이 될 만한 소견들)

  • Kim, Heung-Cheol;Lee, Jun-Ho;NamKung, Sook;Hong, Myung-Sun;Hwang, Im-Kyung
    • Korean Journal of Head & Neck Oncology
    • /
    • v.24 no.1
    • /
    • pp.53-56
    • /
    • 2008
  • Objectives:The purpose of this study was to evaluate the variable sonographic features in addition to classic findings and to find the helpful characteristic findings for diagnosis of branchial cleft cysts. Subjects and Methods:We retrospectively analyzed the sonographic finding of 16 histopathologically proven branchial cleft cysts. Assessment involved the following variables : location related to carotid artery, size, cyst wall, border, margin, shape, internal echotexture, post echoic enhancement, orientation of longitudinal axis relative to the long axis of the neck, and tapering edge. Results:Most branchial cleft cysts were seen as well defined(15/16), oval shape(13/16), smooth inner (12/16) and outer margin(13/16), and post echoic enhancement(16/16). Their diameter varied from 1 to 6cm (mean 3.3cm). The branchial cleft cysts showed variable internal echopatterns;hyperechogenicity or pseudosolid appearance(1/16), heterogeneous echogenicity(4/16) in addition to classic form of anechoic(5/16) or hypoechoic internal echogenicity(6/16). Longitudinal axis of most branchial cleft cysts were arranged in the direction of the long axis of the neck(13/16) and some branchial cleft cysts had tapering edge(6/16). Conclusion:If both atypical sonographic findings and location are showed, longitudinal arrangement of long axis and tapering edge of branchial cleft cysts are helpful findings for differential diagnosis.

Analysis of Primary Breakup Characteristics Depending on the Boss and Deflector Dimension of Fire Sprinkler Head using LES-VoF (LES-VoF를 이용한 소방용 스프링클러 헤드의 보스 및 디플렉터 치수에 따른 1차 분열 특성 분석)

  • Kim, Taehoon
    • Journal of ILASS-Korea
    • /
    • v.26 no.3
    • /
    • pp.127-134
    • /
    • 2021
  • Fire sprinkler initial spray was analyzed by Large eddy simulation (LES) and Volume of Fluid (VoF) integrated method. The IsoAdvector geometric VoF was used to identify the liquid-gas interface clearly even with the large Courant-Friedrichs-Lewy number. To reduce the computational costs, sector meshes and Adaptive Mesh Refinement up to level 3 were used. Base mesh size was 1 mm, which is roughly equivalent to the initial sprinkler droplet. Top surface radius of boss and deflector size were modified to investigate the effects of sprinkler head design on primary breakup process. When top surface radius of boss was increased, vertical liquid sheet was formed. This phenomenon reduced the sheet breakup radius, sheet thickness and velocity. Due to reduced liquid sheet thickness, a large amount of ligaments was created from the liquid sheet. As a result, there was a dramatic decrease in volume per surface area, indicating an increase in breakup process. Spray pattern viewed in radial direction also changed when top surface radius of boss increased. When top surface radius of boss was increased, a T-shaped pattern was observed while a V-shaped pattern was observed in all other cases. When the deflector size increases, the spray pattern remains V-shaped, even if the top surface radius of boss increased. Further studies on promoting atomization of the water supplied to the lower part of the sprinkler head in the T-shape pattern should be conducted.

The influence of horizontal cephalic rotation on the deviation of mandibular position

  • Katayama, Naoto;Koide, Kaoru;Koide, Katsuyoshi;Mizuhashi, Fumi
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.6
    • /
    • pp.401-407
    • /
    • 2018
  • PURPOSE. When performing an occlusal procedure, it is recommended that the patient should be sitting straight with the head in a natural position. An inappropriate mandibular position caused by an incorrect occlusal record registration or occlusal adjustment can result in damaged teeth and cause functional disorders in muscles and temporomandibular joints. The purpose of this study was to clarify the influence of horizontal cephalic rotation on mandibular position by investigating the three-dimensional positions of condylar and incisal points. MATERIALS AND METHODS. A three-dimensional jaw movement measurement device with six degrees of freedom (the WinJaw System) was used to measure condylar and incisal points. The subjects were asked to sit straight with the head in a natural position. The subjects were then instructed to rotate their head horizontally $0^{\circ}$, $10^{\circ}$, $20^{\circ}$, $30^{\circ}$, $40^{\circ}$, $50^{\circ}$and $60^{\circ}$ in the right or left direction. RESULTS. The results indicated that horizontal cephalic rotation made the condyle on the rotating side shift forward, downward, and toward the inside, and the condyle on the counter rotating side shift backward, upward, and toward the outside. Significant differences in deviations were found for angles of rotation higher than $20^{\circ}$. The incisal point shifted in the forward and counterrotating directions, and significant differences were found for angles of rotation higher than $20^{\circ}$. CONCLUSION. The mandibular position was altered by horizontal cephalic rotations of more than $20^{\circ}$. It is essential to consider the possibility of deviation of the mandibular position during occlusal procedures.