Analysis of SAR on Human Head Caused by Antenna of PCS Handheld Telephone

PCS 전화기의 안테나에 의해 인체 두부에 유기되는 SAR 분석

  • Park, Ju-Derk (Division of Electrical and Electronic Eng., Chungbuk National Univ.) ;
  • Kim, Nam (Division of Electrical and Electronic Eng., Chungbuk National Univ.)
  • 박주덕 (충북대학교 전기전자공학부) ;
  • 김남 (충북대학교 전기전자공학부)
  • Published : 1999.12.01

Abstract

In this paper, the detection of 1 g and 10 g averaged SAR on human head caused by PCS handheld phones is analyzed and discussed. Conventional monopole antenna and planar structured PIFA are used in the computational model to apply to the antennas mounted on handheld phone. These antennas are designed to operate in the near of frequency 1.8 GHz, human head model is sampled to have cell size 1.5 mm and sloped to front direction by 30$^{\circ}$. It is found that, when monopole antenna is applied, 1 g averaged SAR is 1.4 W/kg, 10 g averaged SAR is 0.7 W/kg, when PIFA is applied, for each case, SARs are 1.143 W/kg, 0.4866 W/kg. While the radiation pattern of the monopole antenna is symmetrical, that of planar structured antenna is asymmetrical and SAR caused by PIFA is less than SAR by the monopole antenna. The radiation efficiency of PIFA is 62.6%, which is higher than that of monopole, 53%.

본 논문에서 pes 이동통신 전화기에 의해 인체 두부에 유기되는 SAR의 19 펑균과 109 평균의 검출과 비교 분석을 하였다. 이동통신 전화기의 안테나로 기존의 모노폴 안테나와 명변형 구조인 PIF A(Planar Inverted F A An tenna)를 채택하였다. 두 안테나는 1.8 GHz 부근의 주파수 대역에서 공진이 이루어지게 설계하였고, 인체두 부를 1.5 mm의 공간 이산간격으로 표본화한 후 $30^{\circ}$ 전방으로 기울어진 모텔로 구성하였다. 19 및 109 평균의 첨두 SAR을 검출한 결과 기존의 모노폴이 탑재된 출력 320 mW인 pes 이동통신 전화기에 의해 각각 약 1.4W/kg,0.7W/kg이 검출되었고 PIFA가 탑재된 pes 이동통신 전화기에서는 1.1434 W/kg, 0.4866 W/kg 으로 나타났다. 평면형 구조의 안테나는 등방성 방사패턴을 나타내는 모노폴 안테나에 비해 인체 외부방향으로 지향성 방사 패턴을 나타내어 인체 두부에 유기되는 SAR이 낮은 값으로 나타났으며 안테나의 방사 효율은 모노폴 안테나의 5 53 %에 비해 62.6 %로 높아졌다.

Keywords

References

  1. European Committe for Electrotechnical Standardization SECRETARIAT SC 211/B WAMTE Considerations for Human Exposure to EMFs from Mobile Telecommunication Equipment(MTE) in the Frequency Range 30 MHz~6 GHz CENELEC
  2. IEEE Standard for Safety Levels with Respect to Human Exposure to Ratio Frequency Elecromagnetic Field, 3kHz to 300GHz(Revision of ANSI C95.-1992) IEEE
  3. IEICE Trans. on Communications v.E80-B no.5 Domestic Evaluation of Handheld Mobile Communications Equipment with Known Precision N. Kuster;R. kastle;T. Schmid
  4. Human Head and Shoulders Mesh with 3mm cells
  5. The Finite Differece Time Domain Method for Electromagnetics K. S. Kunz;R. J. Luebbers
  6. IEEE Trans. on Microwave Theory Tech. v.44 no.10 Electro Magnetic Absorption in the Human Head and Neck for Mobile Telephone at 835 and 1900MHz O. P. Gandhi
  7. Proceedings of the IEEE v.83 no.1 EM interaction of handset antennas and a human in personal communications M. A. Jensen;Yahya Rahmat-Samii
  8. IEEE Trans. on Ant. and Propa. v.42 no.8 Performance analysis of antennas for hand-held transceiver using FDTD M. A. Jensen;Yahya Rahmat-Samii
  9. 한국전자파학회논문지 v.8 no.6 평면파에 노출된 인체 두부의 전력 흡수 해석 이애경
  10. IEEE Trans. on Microwave Theory Tech. v.48 no.12 Finite-Difference Time Domain Analysis of a Dual Resonance and Shielded Cellular Antenna B. S. Yildirim;E. Badawy
  11. IEEE Trans. on Electromagnetic Compatibility v.37 no.4 Electromagnetic absorption in the human head form experimented 6-GHz handheld transceivers O. P. Gandhi;J. Y. Chen
  12. IEEE Trans. on Microwave Theory Tech. v.MTT-44 no.10 A study of the handset antenna and human body interaction M. Okoniewski;M. A.Stuchly
  13. 정보통신단체표준 800MHz대 디지털 이동전화 무선인터페이스 표준 한국정보통신시술협회