• Title/Summary/Keyword: head control

Search Result 1,771, Processing Time 0.035 seconds

Effects of Postural Control Training Using a Visual Blind Board on Head Control, Trunk Control, and the Sitting Abilities of Children with Moderate to Severe Cerebral Palsy: A Pilot Study (시야 가림막을 활용한 자세 조절 훈련이 중등도-중증 뇌성마비 아동의 머리 조절, 몸통 조절, 앉기 능력에 미치는 효과: 예비연구)

  • Kim, Kun-Woo;Lee, Min-Goo;Hahm, Suk-Chan
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.17 no.3
    • /
    • pp.31-40
    • /
    • 2022
  • PURPOSE: This study was conducted to investigate the effects of postural control training using a visual blind board, on head control, trunk control, and the sitting abilities of children with moderate-to-severe cerebral palsy. METHODS: Ten children with moderate to severe cerebral palsy participated in this study. Postural control training with a visual blind board was given for 40 minutes per session, 3 times a week for 4 weeks (12 sessions). Before and after the intervention, head control, trunk control, and sitting abilities were quantified using the head control scale, Korean version-trunk control measurement scale, and the sitting part of the Korean version-gross motor function measure-88, respectively. RESULTS: Postural control with the visual blind board significantly improved the head control ability of children with moderate to severe cerebral palsy (p = .015). Their trunk control abilities also showed significant improvement after the intervention (p = .016). However, their sitting ability did not show a significant change. CONCLUSION: These results showed that postural control training using a visual blind board is effective in improving the head and trunk control abilities of children with cerebral palsy. Further studies with suitable sample sizes and control groups are needed to reach a conclusion about the use of postural control training with visual blind boards for improvement of postural control of children with moderate to severe cerebral palsy.

A Study on the Correlation between Signs/Symptoms of the Craniomandibular Disorder and Head/Neck Posture (두개하악장애의 증후발현과 두경부자세 사이의 상관성에 관한 연구)

  • Kyeung-Suk Choi;Keum-Back Shin;Ik-Jun Lim
    • Journal of Oral Medicine and Pain
    • /
    • v.18 no.2
    • /
    • pp.131-147
    • /
    • 1993
  • To evaluate the contribution of head/neck posture to signs/symptoms of craniomandibular disorder(CMD), the author clinically, cephalo-metrically, analyzed craniomandibular index (CMI), clinical dysfunction index(CDI), occlusal index(OI) and head posture, cervical spine, cervicovertebral anatomy, craniofacial variables from 30 CMD patients and control. And the author analyzed difference between patients and control, and the correlation between CMI, CDI and head posture, cervical spine, cervicovertebral anatomy, craniofacial variables in CMD patients and control. The obtained results were as follows : 1. There was very high significant correlation between CMI and CDI(r=0.8969, p<0.01). 2. There was significant difference between patients and control in head/neck posture, head/neck anatomy(p<0.05). 3. There was significant correlation between CMI, CDI and head posture, cervical spine, cervicovertebral anatomy, craniofacial variables(p<0.05). 4. There was more significant correlation between DI and head/neck posture, head/neck anatomy than between PI and head/neck posture, head/neck anatomy in CMD patients(p<0.05)

  • PDF

Mass-flow Stabilization Control of a Strip Head Part in Hot Rolling Process (열간 압연공정의 선단부 통판성 안정화 제어)

  • Hwang, I-Cheol;Park, Cheol-Jae;Baek, Woon-Bo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.3
    • /
    • pp.330-336
    • /
    • 2009
  • This paper studies on the new control algorithm for the mass-flow stabilization in strip head part of a hot strip mill. A new strip tension model in the strip head part is derived using the current deviation of two neighboring stands. The current deviation means a difference between a measured current and a lock-on current, where the lock-on current is set up when a strip tension or a looper angle reaches each target value or time is about 0.4sec, respectively. On the basis of the tension calculation model, a mill velocity of a backward stand is controlled to stabilize a strip mass-flow by PI control algorithm. Therefore, the mass-flow control for strip head part is executed from a metal-in time into a foreward stand till the looper works normally. It is known by the results of a computer simulation and an experiment that the proposed control algorithm is very effective in stabilizing the mass flow of the strip head part.

Process Improvement of PCB Electric Circuit Pattern by Ink Drop Jetting Control and Characteristics Analysis of Industrial Inkjet Piezoelectric Print Head (산업용 잉크젯 압전프린트 헤드의 특성해석 및 잉크 망점제어에 의한 PCB 전기회로패턴 공정개선)

  • Youn, Shin-Yong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.1
    • /
    • pp.57-65
    • /
    • 2016
  • This paper was analyzed the characteristics of piezoelectric inkjet print head using finite element method(FEM). It showed the bending node driving of piezoelectric and relation theory principle consider piezoelectric material characteristics and ink characteristics. From such result we were had the piezoelectric head design and manufacture. It got a this head characteristics through experiment, we confirmed that proper voltage control is possible to through ink drop control experiment of piezoelectric print head. This paper was obtained the suitable ink jetting characteristics that manufacture the control circuit and piezoelectric inkjet print head. This practice product was applied to improvement of PCB electric circuit pattern by etching resist ink that PCB manufactured to complex process over traditional 6 stages can be simpled to 1 stage by inkjet printing technology.

The Effect of Postural Correction and Visual Feedback on Muscle Activity and Head Position Change During Overhead Arm Lift Test in Subjects with Forward Head Posture

  • Xu, Liwen;Hwang, Byoungha;Kim, Teaho
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.3
    • /
    • pp.151-156
    • /
    • 2019
  • Purpose: This study aimed to investigate the immediate effects of posture correction and real-time visual feedback using a video display on muscle activity and change of head position during overhead arm lift test in individuals with forward head posture. Methods: Fifteen subjects with forward head posture and fifteen normal subjects who volunteered were included in this study. During both groups performed the overhead arm lift test, the muscle activity of the upper trapezius, serratus anterior, sternocleidomastoid, and lower trapezius muscle were measured using electromyography, and head position change was measured using photographs. Then, forward head posture group was asked to perform overhead arm lift test again after posture correction and real-time visual feedback using a video display respectively. One-way analysis of variance (ANOVA) was used to analyze four conditions: pre-test, posture correction, real-time visual feedback, and the control group. Results: The upper trapezius and lower trapezius muscle activity significantly decreased posture correction, real-time visual feedback, and control group than pre-test of forward head posture group (p<0.05). The sternocleidomastoid muscle significantly decreased real-time visual feedback and control group than pre-test of forward head posture group. Head position change significantly decreased three conditions than pre-test of forward head posture group and real-time visual feedback and control group significantly decreased than posture correction. Conclusion: This study recommend for maintaining cervical stability during the overhead arm lift test, postural control using real-time visual feedback is more effective in subjects with forward head posture.

A Study on the Control System for Piezoelectric Inkjet Head (압전 잉크젯 프린터 헤드 제어에 관한 연구)

  • Lee, Dal-Ho;Han, Hyung-Seok
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.8 no.1
    • /
    • pp.30-35
    • /
    • 2009
  • In this paper, the type of inkjet heads and the control of head of inkjet printer are surveyed. The electronic parts of inkjet printer are composed of main- board and sub-board. The inkjet head is controlled by using these boards. The results from silver ink jetting experiment are given. The results show that the implemented inkjet system can give a satisfactory performance.

  • PDF

A Study on the Head and Neck Posture Related to Cervical Curvature in Patients with Craniomandibular Disorders (경추만곡도를 이용한 두개하악장애에 환자의 두경부자세에 관한 연구)

  • Min-Shin;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.361-376
    • /
    • 1995
  • The purpose of this study was to investigate the relationship between the head and neck postre and the cervical curvature, especially in forward head postrue(FHP). Sixty patients with craniomandibular disorders and thirty dental students without any signs and symptoms of craniomandibular disordres participated in this study as patient groups and sa control group, respectively. The author evaluated the head and neck posture of all subjects by plumb line and CROM( Cervical Ragne of Motion), and had taken cephaograph in natural head position. On the cephalograph the angle of cervical inclination formed by true horizntal plane and 4th cervical vertebra(C4) and the radius of cervical curvature from C1 to C5 were measured. A specially designed ruler was used for measuring cervical curvature. Occlusal contac number and force with T-scan system, electromygraphic activity of cervical muscles with Bio-EMG, and distance of freeway space with Bio-ECN were recorded, respectively. The collected data were processed by SAS/STAT progrm. The obtained results were as follows : 1. In subjects with longer radius which was less cervical curvature, head positioned more anteriorly than subjects with smaller radius, and they showed slightly straight cervical vertebra. 2. Between the patients and the control group, there were no differences in cervical curvature, in forward head position by plumb line and in CROM. But the patient group had a greater cervical inclination than the control group had. 3. There were positive correlation between cervical curvature and forward head position by plumbline,between forward head position y plumb line and that by CROM in patient group. The cervical inclination, however, had negative correlation with cervical curvature, and with forward head postion by plumb line, respectively. 4. In case of showing more cervical curvature and more forward head position by plumb line the head position was defined as forward head posture. In patient group, subjects without forward head posture showed greater posterior teeth contact force than subjects with forward head posture, but in control group, there were no difference between the two subjects. 5. There were higher electromyographic activity in almost all muscles and smaller freeway space in induced forward head posture than those in natural head position in subjects without forward head posture. In conclusion, head position of patients with craniomandibular disorders were not more anterior than that of normal control person, but they had tendency to head extension. From the result of this study, forward head posture could be defined as posterior rotation of upper cervical segment with a straight lower cercial segment due to loss of normal lordosis.

  • PDF

Effects of Dietary Vitamin E and Selenium Supplementation on Meat Color Stability of Hanwoo(Korean Native Cattle) Bull Beef during Retail Display (Vitamin E와 Selenium의 급여가 비거세우육의 진열저장중 육색 안정성에 미치는 영향)

  • 김용선;양성운;김주용;박연수;황환섭
    • Food Science of Animal Resources
    • /
    • v.22 no.2
    • /
    • pp.108-114
    • /
    • 2002
  • The effects of dietary vitamin E and selenium(Se) supplementation on meat color stability in M. Longissimus of Hanwoo(Korean native cattle) bull beef during retail display(5$^{\circ}C$, 1,200 lux) were investigated. Experimental groups were divided into control(Vit E 27 IU/head/day, Se 0.09 mg/head/day), Vit E (2,500 IU/head/day), Se(20 mg/head/day), Vit E+Se(Vit E 2,500 IU/head/day, Se 20 mg/head/day) groups. CIE a*(redness), chroma(C*) values, oxymyoglobin(%) and R630-R580 were significantly (p<0.05) decreased among the 4 treatment groups during retail display, in particular, those values decreased more rapidly in the control group. The metmyoglobin (%) of 0 day(before storage) was not significantly (p<0.05) different among the 4 treatment groups. However, the rate of metmyoglobin accumulation during storage increased more rapidly in the control group. Therefore, discoloration in the control group was more accelerated compared to the other groups. TBARS(thiobarbituric acid reactive substances) which represent lipid rancidity was significantly(p<0.05) lower in Se and Vit E+Se groups than in the control and Vit E groups. Reducing ability of 0 day(before storage) was significantly lower in the control group than in the other groups, and it decreased more rapidly in the control group after 3 days of storage. Consequently, Se-supplemented groups(Se and Vit E+Se groups) were more resistant to lipid oxidation than were the control and Vit E groups. The stability of meat color and myoglobin forms(%) were significantly (p<0.05) higher in Vit E, Se and Vit E+Se groups than in the control group, but there were no difference among Vit E, Se and Vit E+Se groups.

Tele-Operated Mobile Robot for Visual Inspection of a Reactor Head

  • Choi, Chang-Hwan;Jeong, Kyung-Min;Kim, Seung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2063-2065
    • /
    • 2003
  • The control rod drive mechanisms in a reactor head are arranged too narrow for a human worker to approach. Moreover, the working environment is in high radiation area. In order to inspect defections in the surfaces of the reactor head and welding parts, a visual inspection device that can approach such a narrow and high radiation area is required. This paper introduces a tele-operated mobile robot for visual inspection of a reactor head, which has pan/tilt camera, fixed rear camera, ultrasonic collision detection system, and so on. Moreover, the host controller and digital video logging system are developed and integrated control software is also developed. The robot is operated by a wireless control, which gives flexibility for the inspection.

  • PDF

A study on the railway signal system for high density traffic (열차의 고밀도운전을 위한 신호보안 시스템에 관한 연구)

  • 강규현;김희식
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.163-166
    • /
    • 1997
  • In order to shorten head-way time on existing railway lines without any change of signal block length between stations, it is a realistic optional way to change the control method of train signal, i.e. to modernize the cab signal using transponder. A new signalling system of operation pattern control technique is suggested as new model to increase the railway traffic efficiency. Through the computer simulation of this model, the train head-way time by the fixed signalling system and the new pattern control system is analyzed.

  • PDF