• Title/Summary/Keyword: hazardous areas

Search Result 195, Processing Time 0.024 seconds

Prediction of Forest Fire Hazardous Area Using Predictive Spatial Data Mining (예측적 공간 데이터 마이닝을 이용한 산불위험지역 예측)

  • Han, Jong-Gyu;Yeon, Yeon-Kwang;Chi, Kwang-Hoon;Ryu, Keun-Ho
    • The KIPS Transactions:PartD
    • /
    • v.9D no.6
    • /
    • pp.1119-1126
    • /
    • 2002
  • In this paper, we propose two predictive spatial data mining based on spatial statistics and apply for predicting the forest fire hazardous area. These are conditional probability and likelihood ratio methods. In these approaches, the prediction models and estimation procedures are depending un the basic quantitative relationships of spatial data sets relevant forest fire with respect to selected the past forest fire ignition areas. To make forest fire hazardous area prediction map using the two proposed methods and evaluate the performance of prediction power, we applied a FHR (Forest Fire Hazard Rate) and a PRC (Prediction Rate Curve) respectively. In comparison of the prediction power of the two proposed prediction model, the likelihood ratio method is mort powerful than conditional probability method. The proposed model for prediction of forest fire hazardous area would be helpful to increase the efficiency of forest fire management such as prevention of forest fire occurrence and effective placement of forest fire monitoring equipment and manpower.

Distribution of $NO_{x}$ and CO among the Ambient air by traffic volume characteristics and distance from roadside (The Sungnam City Case) (교통량특성과 거리에 따른 대기 오염물질 분포에 관한 연구(성남시의 $NO_{x}$, Co를 중심으로))

  • 권우택;김형철
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.3
    • /
    • pp.41-49
    • /
    • 1997
  • In South Korea since 1970s the rapid development of economic growth has brought about "Urbanization" in many areas and also raised the level of people's life in many ways. At the same time, however, the industrialization and overpopulated districts in many areas have caused the problems of air pollution in necessary. Among those air pollution, in particular, in large cities has become more serious since 1990s than before. Air pollution, like TSP and SO$_{x}$ caused by heating, generation of electric power and industrialization in 1980s, showed as that of the type of an underdeveloping country and was not hazardous enough to people in the least. Unfortunately, in 1990s NO$_{x}$, CO and O$_{3}$ caused by the soaring numbers of many types of cars have exhausted air pollutant more hazardous as the same air pollution type of many developed countries. So, the purpose of this study would be to analyze the changes of concentration of NO$_{x}$ and CO on environmental air by traffic volume and from the side drive way to the degree of distance in Sungnam City, and recognize the citizens' consciousness to air pollution and suggest the best walking point in part, and plan to design the reasonable use of cars and finally make the air quality improve toward the better-ment in part. From the research result we can know that people walking in the street would be protected from the hazardous air pollutant caused by the cats if they walk apart from a drive way as far as they can in the street. Accordingly, it might, to minimize th affect of air pollution, be thought to be desirable that the consideration of in introduction the system that the vehicle using the diesel engine motor should use the centered-lane aparted from road. Another to be desirable is that along side the road, the trees inhaled the pollution should be planted.

  • PDF

A study on the Prediction of Explosion Risk for the Low Pressure Natural Gas Facilities with Different Explosion Conditions (저압 도시가스 사용설비의 누출 조건에 따른 폭발 위험 분위기 형성 범위 예측에 관한 연구)

  • Han, Sangil;Lee, Dongwook;Hwang, Kyu-Suk
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.3
    • /
    • pp.59-65
    • /
    • 2016
  • It is imperative to use suitable explosion proof equipments to prevent explosion in different gas facilities. There is no technical standard for the classification of hazardous areas though standard of explosion proof is regulated. In this study, we have adopted Industrial Standard KS to develop the methodology for the prediction of the explosion risk in the natural gas facility with low pressure using the important factors including hole size, hypothetical volume, validation of ventilation effectiveness. The applicability of the developed methodology was evaluated by the comparison with the data obtained from experiments of natural gas explosion.

Factors associated with the Patterns of Alcohol Use in Korean Adults (한국 성인의 음주 유형에 대한 영향요인)

  • Chung, Sung Suk;Joung, Kyoung Hwa
    • Korean Journal of Adult Nursing
    • /
    • v.24 no.5
    • /
    • pp.441-453
    • /
    • 2012
  • Purpose: This secondary data analysis study was aimed at identifying the factors related to the patterns of alcohol use (normal alcohol use, hazardous alcohol use, and alcohol dependence) in the Korean adult. Methods: This study analyzed the cross-sectional data from 230,715 Korean adults aged 19 year and older who participated in the 2009 Korean Community Health Survey. Multinomial logistic regression was used to uncover associations between demographic, health related factors and the patterns of alcohol use. Results: The patterns of alcohol use was differentiated from the sociodemographic variables (residential area, gender, age, marital status, educational level, monthly income, and occupation) and with health related factors (smoking status, hours of sleep, body mass index, pain or discomfort, subjective health, stress level, liver disease, cardio/cerebro vascular disease, and depression). Hazardous alcohol use was lower in rural areas and lower among women, but higher among people who smoke, reported severe stress, and/or depression. Similarly, alcohol dependence was lower among women and among those in rural areas, and was more likely associated with those who smoke, have severe stress and depression. Conclusion: A number of factors are associated with patterns of drinking. Smoking, severe stress and depression seems to confound the problems of alcohol use. Additional research is needed to isolate those factors that are the most important influencing the use of alcohol.

Constructional Properties and Evaluation Methods of the Non-Incendive Type of Explosion-Proof Electrical Apparatus (비점화(非點火)(Non-Incendive)형(型) 방폭(防爆) 전기기기(電氣機器)의 구조특성(構造特性) 및 평가방법(評價方法))

  • Choi, Sang-Won;Lee, Gwan-Hyung;Moon, Jung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.110-113
    • /
    • 1994
  • In the hazardous areas where explosive substances in the form of gases, vapor or mists exist, electrical apparatus and installations must be of explosion-proof construction to prevent or limit the danger of the ignition of potentially explosive atmosphere. In Korea, six types of protection have been specified in the government regulations at present: flameproof enclosure, pressurization, oil immersion, increased safety, intrinsic safety, and special types. If electrical apparatus are made of explosion-proof construction in a way other than five above-mentioned types, and their performance is tested and approved by the reponsible authorities, they may be categorized as special type apparatus. In this paper, we introduced a special type of explosion-proof electrical apparatus, called non-incendive type, and presented its constructional requirements. We also investigated evaluation methods of non-incendive type apparatus to assure the explosion-proof performance, and proposed a new classification method of hazardous areas using probabilistic concept.

  • PDF

Deep Learning(CNN) based Worker Detection on Infrared Radiation Image Analysis (딥러닝(CNN)기반 저해상도 IR이미지 분석을 통한 작업자 인식)

  • Oh, Wonsik;Lee, Ugwiyeon;Oh, Jeongseok
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.6
    • /
    • pp.8-15
    • /
    • 2018
  • worker-centered safety management for hazardous areas in the plant is required. The causes of gas accidents in the past five years are closely related to the behavior of the operator, such as careless handling of the user, careless handling of the suppliers, and intentional, as well as equipment failure and accident of thought. In order to prevent such accidents, real-time monitoring of hazardous areas in the plant is required. However, when installing a camera in a work space for real-time monitoring, problems such as human rights abuse occur. In order to prevent this, an infrared camera with low resolution with low exposure of the operator is used. In real-time monitoring, image analysis is performed using CNN algorithm, not human, to prevent human rights violation.

Dispersal of Hazardous Substance in a City Environment Based on Weather Conditions and Its Risk Assessment at the Pedestrian Level (기상조건에 따른 도시내 위험물질 확산정보와 보행자환경 위험영향평가)

  • Kim, Eun-Ryoung;Lee, Gwang-Jin;Yi, Chaeyeon
    • Journal of Environmental Impact Assessment
    • /
    • v.26 no.4
    • /
    • pp.242-256
    • /
    • 2017
  • In this paper, dispersion scenarios concerning various meteorological conditions and real urban structures were made to estimate the impacts of hazardous substance leakage accidents and to reduce damages. Based on the scenario of the hazardous substance dispersion, the characteristics of the risk in the pedestrian environment were analyzed in Gangnam, Seoul. The scenarios are composed of 48 cases according to the meteorological conditions of wind direction and wind speed. In order to analyze the dispersion characteristics of the hazardous substances, simulations were conducted using a computational fluid dynamic (CFD) model with hydrogen fluoride releases. The validation for the simulated wind was conducted at a specific period, and all the calculated verification indices were within the valid range. As a result of simulated dispersion field at pedestrian level, it was found that the dispersion pattern was influenced by the flow, which was affected by the artificial obstacles. Also, in the case of the weakest wind speed of the inflow, the dispersion of the hazardous substance appeared in the direction of the windward side at the pedestrian level due to the reverse flow occurred at lower layers. Through this study, it can be seen that the artificial structures forming the city have a major impact on the flow formed in urban areas. The proposed approach can be used to simulate the dispersion of the hazardous substances and to assess the risk to pedestrians in the industrial complexes dealing with actual hazardous substances in the future.

A Study of Emergency Response for the Leakage Accident of Hazardous and Noxious Substances in a Port (항만에서의 위험·유해물질(HNS) 누출사고 대응에 관한 연구)

  • Woo, Young Jin;Lee, Chang Jun
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.6
    • /
    • pp.32-38
    • /
    • 2016
  • In general, lots of containers including various dangerous materials are transported to the port located in big cities such as Busan where massive residents live. Thus, it's really important how to make the emergency response for the leak accidents of dangerous materials and evaluate the direct or indirect damages to adjacent areas. In this study, in order to make reasonable emergency plans, CA (Consequence Analysis) is employed after selecting a key hazardous and noxious material, hydrogen fluroide. This material accounts for the third largest portion of cargo volume among all dangerous materials and can cause a huge damage in case of leakages. As a case study, Busan North port is selected as a test port since the portion of dangerous materials is higher than that of other ports in Busan. It is assumed that 1 ton of hydrogen fluoride is spilled at Busan North port. CA is performed to assess the impact of this accident. Throughout CA, the ERPG-2 range of a leak accident can be evaluated and this result can be used for decision making tools for mitigating the impact of a leak accident. To mitigate the damage of this accident, suitable a protective equipment and resident evacuation procedures should be prepared. Finally, this study can provide a systematic approach to make the emergency plan for reducing economical and personal losses.

Hazardous event analysis in drinking water production using aquifer storage transfer and recovery (대수층 저장·이동 및 회수에 의한 음용수 생산과정에서의 위해사건분석)

  • Lee, Sang-Il;Ji, Hyon-Wook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.1
    • /
    • pp.23-31
    • /
    • 2015
  • Aquifer storage transfer and recovery (ASTR) is a type of managed aquifer recharge which entails injecting water into a storage well and recovering it from a different well. It has effects of natural purification when injected water passes through aquifer medium, and can be a good way of supplying water especially in a region with poor surface water quality. This study is about an on-going effort to introduce ASTR as a solution to source water problems in coastal areas. A pilot study is being conducted in the delta of the Nakdong River. A proactive management system is incorporated to ensure the water qulity in the process of drinking water process. The system is based on the Hazard Analysis and Critical Control Point (HACCP) which is a tool originated from the food industry in order to assess hazards and establish control systems for the safety of food product. In this paper, we analyze hazardous events which can occur in the entire water supply system using ASTR as a first step to the incorporation of HACCP to drinking water production process.

A Study on the Concentration Analysis of Roadside Air Pollutants

  • CHOI, Jong-Sun;JUNG, Min-Jae;LEE, Jun-Cheol;KWON, Woo-Taeg
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.4 no.2
    • /
    • pp.35-41
    • /
    • 2021
  • Purpose: In this study, volatile organic compounds(VOCs) and aldehydes generated from roadside vehicles and other pollutants were measured and analyzed. Research design, data and methodology: As a result of measuring and analyzing three areas near the roadside, Vinyl chloride 0.00 ~ 0.02 ppb, Benzene 2.87 ~ 5.01 ppb. Toluene 4.51 ~ 8.62 ppb, Styrene 0.00 ~ 0.34 ppb, Formaldehyde 8.45 ~ 17.12 ug/m3, Acetaldehyde 7.01 ~ 17.64 ug/m3 were detected. When comparing the analysis results and the 6-month average concentration of the hazardous air monitoring network, the analysis results were about 26 times higher for Benzene, about 5 times for Toluene, and about 3.75 times for Styrene. In the case of vinyl chloride, it was confirmed that it was about 20 times lower than that of the hazardous atmosphere monitoring network. Results: Therefore, it is necessary to reexamine the installation location of the measurement network because people are exposed to pollutants on the actual roadside. It is judged that it is right to build a measurement network that is practically helpful to people by increasing the measurement items in the measurement network.