• Title/Summary/Keyword: harmonic reduction.

Search Result 428, Processing Time 0.028 seconds

Harmonic Current Reference Generation of Single-Phase Active Filter for the Converter-Fed Locomotives (고속전철용 단상능동필터의 기준고조파전류 발생 방법)

  • Sung, Gi-Seok;Song, Joong-Ho;Choi, Ik;Choi, Ju-Yeop;Kim, Gwang-Bae;Kim, Kwon-Ho;Lim, Myo-Taek
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.338-341
    • /
    • 1999
  • PWM controlled line-side converters of modern ac traction locomotives inject harmonic currents into the feeding overhead line. This causes problem of electromagnetic interference. Passive and Active filters are usually provided for a reduction of the line harmonics. Active filters are more reasonable than passive filters in terms of weight and space of the filters. Successful control of active filters requires an accurate harmonic current reference. A technique to generate the harmonic current reference is proposed in this paper. The analysis is performed in frequency domain and its effectiveness is verified by simulation.

  • PDF

Harmonic Intensity Reduction Technique for Single Phase Switched Reluctance Motor Drives Using a New Random PWM Scheme

  • Nguyen, Minh-Khai;Jung, Young-Gook;Yang, Hyong-Yeol;Lim, Young-Cheol
    • Journal of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.51-57
    • /
    • 2010
  • This paper proposes a new random switching strategy using a DSP TMS320F2812 to reduce the harmonics spectra of single phase switched reluctance motors. The proposed method combines the random turn-on/off angle technique and the random pulse width modulation technique. A harmonic spread factor (HSF) is used to evaluate the random modulation scheme. In order to confirm the effectiveness of the proposed method an experiment was conducted. The experimental results show that the harmonic intensity of the output voltage for the proposed method is better than that for conventional methods.

Harmonic Reduction of Three-Phase Boost Rectifier using a Harmonic- Injected (고조파 주입 펄스 폭 변조를 이용한 3상 부스트 정류기의 고조파 저감)

  • Lee, Joon-Ku;Kim, Jin-Sung;Park, Seok-Ha;Kim, Jong-Bum;Kim, Gwang-Su;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2736-2738
    • /
    • 1999
  • Power electronic loads inject harmonic currents into the utility system. The large increase of power consumption will inevitably lead to deteriorating power quality due to the popularization of switch-mode power electronic equipment. In this paper, a periodic voltage is injected in the control circuit to vary duty cycle of the rectifier switch within a line cycle so that the fifth-order harmonic of the input current is reduced to meet the IEC 61000-3-2 requirement. Experimental results are presented to confirm the validity of this method.

  • PDF

The Harmonic Reduction Design of IPMSM No-load line-line Back-EMF for ISG (ISG용 매입형 영구자석 동기 전동기 무부하 선간 역기전력 고조파 저감설계)

  • Lee, Jin-Gyu;Jung, Jae-Woo;Kim, Sung-Il;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.754-755
    • /
    • 2008
  • This paper presents a method for reducing the Total Harmonic Distortion(THD) of line-line back_EMF of the IPMSM with distributed winding under the no-load condition. Firstly, the specific harmonic components of line-line back EMF are reduced considering with winding factor. Secondly, THD of line-line back EMF is minimized according to change of pole angle using by Space harmonic Analysis. Finally, the optimal design for minimizing the THD is conducted using response surface methodology with finite element analysis. The validity of the design method dealt with in this paper is demonstrated by comparison between the THD of optimal model and initial model.

  • PDF

Analysis and Measurement of Current Harmonics Due to Non-linear Load in Low Voltage System (저압 시스템에서 비선형 부하의 사용에 따른 전류 고조파 해석 및 측정)

  • Kim, Jong-Gyeom;Lee, Eun-Ung
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.12
    • /
    • pp.601-608
    • /
    • 2001
  • The ever increasing density of adjustable speed drives(ASD) device with non-linear operating characteristics has been to put tremendous harmonic stress on end user's electrical application. All ASD controllers which employ solid state power devices cause harmonic currents in the source side line. This paper describes harmonic problems for use of ASD. In order to investigate the effect of harmonics caused by using of nonlinear load at the low voltage system, we fixed up simple load model and measured the voltage and current waveforms. Measurement results show that additional operation of linear load at the parallel bus with nonlinear load such as ASD is helpful to the reduction of harmonic influence.

  • PDF

Analysis of harmonics current using non-linear load at low voltage system (저압 시스템에서 비선형 부하의 사용에 따른 고조파 전류 해석)

  • Kim, Jong-Gyeum;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2001.07e
    • /
    • pp.13-16
    • /
    • 2001
  • This paper describes the problems associated with the use of PWM ASDs to drive induction motors. A major effect of harmonic voltages and currents in induction motors is increased heating due to iron and copper losses at harmonic frequencies. The harmonic components thus affect the motor efficiency, and can also affect the torque developed. In order to investigate the effect of harmonics which is caused by using of nonlinear load at the low voltage system, we fixed up simple load model and measured the voltage and current. Measurement. results show that additional operation of linear load at the parallel bus in using nonlinear load such as ASD is helpful to the reduction of harmonic current.

  • PDF

Capacitance reduction method for single-phase PWM converters using the 3rd harmonic injection and PR controller. (3차 고조파 주입과 PR 제어기를 이용한 단상 PWM 컨버터의 커패시터 용량 저감 기법)

  • Kim, Gyu-Dong;Yang, Hyun-Suk;Lee, Dong-Myung
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.1-2
    • /
    • 2013
  • In this paper, we inject input currents having $3^{rd}$ harmonic to reduce the capacitance of DC link capacitors in single-phase converters. If the input current with third harmonic is injected, the required capacitance can be reduced by minimizing the difference between the input and output power. To control the input current, instead of PI control done in rotating frame, PR controller is used with the proposed separate current control method for fundamental and $3^{rd}$ harmonic components. The validity of the proposed method has been demonstrated by simulation results.

  • PDF

A Study on the Optimum Design of Soltless Type PMLSM Using Genetic Algorithm and 3-D Space Harmonic Method (유전 알고리즘과 3차원 공간고조파법을 이용한 Soltless Type PMLSM의 최적설계에 관한 연구)

  • 이동엽;김규탁
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.8
    • /
    • pp.463-468
    • /
    • 2004
  • This paper was applied space harmonic method as a characteristic analysis technique for slotless PMLSM. There is advantages of active response to the change of design parameters as well as reduction of the calculation time. The method can be overcome disadvantages of finite element analysis that needs long times calculation, repetitions of pre and post-process. In this paper, 3D-space harmonic method was applied to consider the precise description of end turn coil shape and the changes of characteristic according to changes of length of z-axis direction. The thrust of optimal design was performed using genetic algorithm to enhance the thrust which is the disadvantage of slotless type PMLSM. For design parameters, width of permanent magnet, width of coil, width of coil inner and lengths of z-axis direction were selected. For objective functions. thrust per weight. thrust per volume. multi-objective function was selected.

An Active Feedforward Compensation for a Current Harmonics Reduction in Three-phase Grid-connected Inverters (3상 계통 연계형 인버터에서의 전류 고조파 감쇄를 위한 능동형 피드포워드 보상 기법)

  • Park, Byong-Jun;Kim, Rae-Young;Choi, Ki-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • This paper proposes a current harmonic compensation method for the grid-connected inverter, especially caused by the grid impedance. Grid impedance causes low order harmonics in the grid current and deteriorates power quality. This paper analyzes the negative impact of the grid impedance, and proposes an active feedforward compensation method. Proposing method verified through simulation and experiment with 3-phase 1.5kW voltage source inverter prototype.

Structural Analysis for Silk Hat type of the Harmonic Drive for Precision Robot (정밀 로봇용 하모닉 드라이브의 실크 햇 형상에 따른 구조해석)

  • Nam, W.K.;Ham, S.H.;Oh, S.H.
    • Journal of Power System Engineering
    • /
    • v.15 no.5
    • /
    • pp.61-66
    • /
    • 2011
  • Recently, the speed reducer which is applied to robot has conducted a steady development on developments in the field of robotics. Among them, Harmonic drive is a high-stiffness, precision-controlled speed reducer and has high precision, compact, light in weight and high-reduction-ratio characteristics. The feature of flexspline of Harmonic Drive are two types. One is Cup type, the other is Silk Hat type. Silk Hat type is used in case of lighter and more compact in spatial because Silk Hat Type is hollow. According to the shape of silk hat, diaphragm is fractured because stress is concentrated. In this paper, the various shapes of silk hat are suggested to improve the durability of silk hat. And in the case of each shape, a study on stress and deformation using the FEM tool was carried out on flexspline.