• Title/Summary/Keyword: harmonic performance.

Search Result 841, Processing Time 0.028 seconds

Harmonic Elimination and Reactive Power Compensation with a Novel Control Algorithm based Active Power Filter

  • Garanayak, Priyabrat;Panda, Gayadhar
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1619-1627
    • /
    • 2015
  • This paper presents a power system harmonic elimination using the mixed adaptive linear neural network and variable step-size leaky least mean square (ADALINE-VSSLLMS) control algorithm based active power filter (APF). The weight vector of ADALINE along with the variable step-size parameter and leakage coefficient of the VSSLLMS algorithm are automatically adjusted to eliminate harmonics from the distorted load current. For all iteration, the VSSLLMS algorithm selects a new rate of convergence for searching and runs the computations. The adopted shunt-hybrid APF (SHAPF) consists of an APF and a series of 7th tuned passive filter connected to each phase. The performance of the proposed ADALINE-VSSLLMS control algorithm employed for SHAPF is analyzed through a simulation in a MATLAB/Simulink environment. Experimental results of a real-time prototype validate the efficacy of the proposed control algorithm.

A Study on the development of Harmonic reduction filter system from PLC control system (PLC제어 시스템에 의한 고조파 제거용 필터 시스템 개발에 관한 연구)

  • An, Hyo-Seop;Shin, Kwan-Woo;Ko, Seok-Bo
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.234-236
    • /
    • 2006
  • In this paper, APF(Active Power Filter) will be treated in order to improve the output current distortion of the AC source. APF generates the harmonic current which contributes to a source side harmonic reduction. We can extract the compensating current of the parallel APF with phase transformations and the proposed current control method. Therefore, the calculation times is short and the control method is simple compared with conventional hysteresis methods. Experimental results verify that the system using the proposed method appers a good performance.

  • PDF

Efficient Hybrid Carrier Based Space Vector Modulation for a Cascaded Multilevel Inverter

  • Govindaraju, C.;Baskaran, K.
    • Journal of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.277-284
    • /
    • 2010
  • This paper presents a novel hybrid carrier based space vector modulation for cascaded multilevel inverters. The proposed technique inherits the properties of carrier based space vector modulation and the fundamental frequency modulation strategy. The main characteristic of this modulation are the reduction of power loss, and improved harmonic performance. The carrier based space vector modulation algorithm is implemented with a TMS320F2407 digital signal processor. A Xilinx Complex Programmable Logic Device is used to develop the hybrid PWM control algorithm and it is integrated with a digital signal processor for hybrid carrier based space vector PWM generation. The inverter offers less weighted total harmonic distortion and it operates with equal electrostatic and electromagnetic stress among the power devices. The feasibility of the proposed technique is verified by spectral analysis, simulation, and experimental results.

Advanced Protective Relaying Algorithm by Flux-Differential Current Slope Characteristic for Power Transformer (전력용 변압기용 자속-차전류 기울기 특성에 의한 개선된 보호계전 알고리즘)

  • 박철원;신명철
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.7
    • /
    • pp.382-388
    • /
    • 2004
  • The most widely used primary protection for the internal fault detection of power transformers is current percentage differential relaying(PDR). However, the harmonic components could be decreased by magnetizing inrush when there have been changes to the material of iron core or its design methodology. The higher the capacitance of high voltage status and underground distribution, the more differential current includes the second harmonic component during occurrence of an internal fault. Therefore, the conventional harmonic restraint methods need modification. This paper proposes an advanced protective relaying algorithm by fluxt-differential current slope characteristic and trend of voltage and differential current. To evaluate the performance of proposed algorithm, we have made comparative studies of PDR fuzzy relaying, and DWT relaying. The paper is constructed power system model including power transformer, utilizing the WatATP99, and data collection is made through simulation of various internal faults and inrush. As the results of test. the new proposed algorithm was proven to be faster and more reliable.

Measurement and Analysis Harmonics Using DSP (DSP를 이용한 고조파 측정 및 분석)

  • Lee, Sang-Ik;Yoo, Jae-Geun;Jeon, Jeong-Chay
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.178-180
    • /
    • 2002
  • Limitation countermeasure on harmonics occurred by power conversion installation, motor speed control equipment, and so on of power system is very important problem, and first of all, accuracy harmonics analysis in system is required for appropriate limitation counterplan. Analysis and judgement on power system harmonic by measurement are needed because analysis by mathematical model generally used for these harmonic analysis, if nonlinear ingredient is included in system, is not relatively correct. So, in this paper, system to measure and analyze harmonic by installing it in a power system, using DSP(Digital Signal Processor), is designed and developed. Also, it's performance is verified by installing it in the system that harmonics occurred.

  • PDF

A Study on the capacity of shunt type active power filter with a thyristor converter load (싸이리스터 컨버터부하를 가지는 병렬형 능동전력필터 용량에 관한 연구)

  • Park, No-Joong;Joeng, Seung-Gi
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2470-2474
    • /
    • 1999
  • The main drawback of parallel type active power filters (APFs) is the large capacity required for harmonic compensation. This paper evaluates the APF capacity requirement for harmonic/reactive power compensation for thyristor converter load. Theoretically achievable maximum power factor under partial load is evaluated. it is shown that the APF capacity can be considerably reduced by deliberately limiting the peak current, while maintaining the filtering performance with an acceptable total harmonic current level. the minimum capacity requirement of APF with current limiting is evaluated as a function of the firing angle of thyristor converter and short circuit ratio(SCR).

  • PDF

Enhancement of Excitation in Low-bit-rate Speech Coders (저 전송률 음성 부호화기를 위한 여기 신호 개선 알고리즘에 관한 연구)

  • 이미숙;김홍국;최승호;김도영
    • Proceedings of the IEEK Conference
    • /
    • 2003.11a
    • /
    • pp.57-60
    • /
    • 2003
  • In this paper, we propose a new excitation enhancement technique to improve the speech quality of low bit rate speech coders. The proposed technique is based on a harmonic model and it is employed only in the decoding process of speech coders without any additional bits. We develop the procedure of harmonic model parameters estimation and harmonic generation. and apply the technique to a current state of the art low bit rate speech coder, ITU-T G.729 Annex D. Also its performance is measured by using the ITU-T P.862 PESQ score and compared to those of the phase dispersion filter and the long-term postfilter applied to the decoded excitation. It is shown that the proposed excitation enhancement technique can improve the quality of decoded speech and provide better quality for male speech than other techniques.

  • PDF

Class-B high efficiency power amplifier by harmonic tuning iwth optimum load impedance (최적 부하 임피던스와 하모닉 튜닝을 이용한 B급 고효율 전력 증폭기의 설계)

  • 류정호;조영송;신철재
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.6
    • /
    • pp.52-61
    • /
    • 1996
  • In this paper, harmonic-tuning method to achieve the maximum efficiency is proposed. Harmonic tuning method is applied to the optimum load impedance of a class B amplifier, which is extracted by using the modified cripps method. High efficiency power amplifier utilizing GaAs MESFET is designed and fabricated in the 835MHz band. The performance of th eamplifier is presented by having output power of 30.8dBm, drain efficiency of 80.5% and power added efficiency of 66% with an associated power gain of 7.4dB.

  • PDF

Design and Fabrication of Direct Conversion RF Module using Even Harmonic Mixer for 2-4GHz ISM band (Even Harmonic Mixer를 이용한 2.4GHz ISM band용 Direct Conversion방식의 RF Module 설계 및 제작)

  • 이주갑;윤영섭;최현철
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2001.11a
    • /
    • pp.222-226
    • /
    • 2001
  • In this paper, 2.4GHz RF Module using Even Harmonic Mixer(EHM) was designed and fabricated for Direct conversion(DC) system. By minimizing performance degradation of DC system with DC offset and LO radiation, the capability of minimization and one chip solution in wireless system was proposed. The designed EHM using anti-parallel diode pair represented 9dB conversion loss and about -60dBm 2LO leakage radiation in RF port, and output reflection and reverse transmission characteristic of low noise amplifier was improved. So superior DC offset suppression characteristic is expected. RF Module which consists of EHM, LNA, RF amplifier, Frequency synthesizer and Duplexer was designed and fabricated.

  • PDF

Harmonic Axisymmetric Thick Shell Element for Static and Vibration Analyses

  • Kim, Jin-Gon
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.10
    • /
    • pp.1747-1754
    • /
    • 2004
  • In this study, a new harmonic axisymmetric thick shell element for static and dynamic analyses is proposed. The newly proposed element considering shear strain is based on a modified Hellinger-Reissner variational principle, and introduces additional nodeless degrees for displacement field interpolation in order to enhance numerical performance. The stress parameters selected via the field-consistency concept. are very important in formulating a trouble-free hybrid-mixed elements. For computational efficiency, the stress parameters are eliminated by the stationary condition and then the nodeless degrees are condensed out by the dynamic reduction. Several numerical examples confirm that the present element shows improved efficiency and yields very accurate results for static and vibration analyses.