• 제목/요약/키워드: harmonic cancellation

검색결과 17건 처리시간 0.038초

A Quantitative Evaluation and Comparison of Harmonic Elimination Algorithms Based on Moving Average Filter and Delayed Signal Cancellation in Phase Synchronization Applications

  • Xiong, Liansong;Zhuo, Fang;Wang, Feng;Liu, Xiaokang;Zhu, Minghua;Yi, Hao
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.717-730
    • /
    • 2016
  • The harmonic components of grid voltage result in oscillations of the calculated phase obtained via phase synchronization. This affects the security and stability of grid-connected converters. Moving average filter, delayed signal cancellation and their related harmonic elimination algorithms are major methods for such issues. However, all of the existing methods have their limitations in dealing with multiple harmonics issues. Furthermore, few studies have focused on a comparison and evaluation of these algorithms to achieve optimal algorithm selections in specific applications. In this paper, these algorithms are quantitatively analyzed based on the derived mathematical models. Moreover, an enhanced moving average filter and enhanced delayed signal cancellation algorithms, which are applicable for eliminating a group of selective harmonics with only one calculation block, are proposed. On this basis, both a comprehensive comparison and a quantitative evaluation of all of the aforementioned algorithms are made from several aspects, including response speed, required data storage size, sensitivity to sampling frequency, and elimination of random noise and harmonics. With the conclusions derived in this paper, better overall performance in terms of harmonic elimination can be achieved. In addition, experimental results under different conditions demonstrate the validity of this study.

SHE-PWM을 적용한 STATCOM에 의한 저차고조파 제거 방법 (Elemination of Low Order Harmonics from STATCOM using SHE-PWM)

  • 최순호;김찬기;이성두
    • 전력전자학회논문지
    • /
    • 제19권5호
    • /
    • pp.450-456
    • /
    • 2014
  • In HVDC converters that employ a line-commutated control, reactive power is absorbed by the rectifier and inverter terminals during AC/DC conversion. An AC filter usually consists of filters and large shunt capacitors to supply reactive power to the HVDC station. When STATCOM is used to supply reactive power to the HVDC system with AC filter, the low-order harmonics generated from STATCOM can result in a resonance between the shunt capacitor and AC network. Therefore, a control strategy based on selective harmonic elimination is adopted to minimize the low-order harmonics from STATCOM. The cancellation of harmonic instabilities is verified through simulations in PSCAD/EMTDC.

MR Line Scan Angiography using Spectral Analysis

  • Jung, Kwan-Jin;Ro, Yong-Man;Sim, Bog-Tae;Ra, Jong-Beom;Cho, Zang-Hee
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1989년도 춘계학술대회
    • /
    • pp.27-28
    • /
    • 1989
  • In conventional line scan angiography, flow signal has been enhanced by the time_of_flight effect while the signal from stationary tissues has been suppressed by the saturation rf pulse followed by spoiling gradients. Due to the inhomogeneous rf field and the tissue dependent T1 relaxation time, however, stationary tissues can not be suppressed completely or uniformly, and the remnant stationary signal deteriorates the resultant angiogram. Here, the complete cancellation of stationary tissues is made possible by the spectral analysis of a series of repetitive line images of the same slice. The Fourier transformation of a set of line images results in the spectrum images, where stationary tissues are collected into the dc component while arteries are included in harmonic components because of the variation of the flow velocity and the resultant flow signal in arteries according to the cardiac cycle. The summation of harmonic components excluding the dc component results in the angiogram of arteries with the complete cancellation of stationary tissues.

  • PDF

전력선 채널의 데이터 전송 특성 개선을 위한 고조파 잡음 제거에 관한 연구 (A Study on the Cancellation of Harmonic Noise for the Improvement of Data Transmission Characteristics in Power Line Channel)

  • 박준현;김남용;강창언
    • 한국통신학회논문지
    • /
    • 제16권3호
    • /
    • pp.259-269
    • /
    • 1991
  • 본 논문에서는 전력선 채널에서 가장 심각한 문제인 임펄스성 고조파 잡음을 제거하기 위한 디지털 신호 처리 기술을 LMS(Least Mean Square)와 ITLMS(Individual Tapped LMS)의 두 가지의 알고리즘을 사용한 선형 예측에 의한 전력선 고조파 잡음 제거 방식을 통해 다루었고 각종 재밍(jamming)에 강한 특징을 가지는 DS(Direct sequnce) 대역 확산 통신을 전력선 채널에 적용하여 전송 성능의 개선을 확인하였다.

  • PDF

Design and Implementation of an Active Power Filter Using Model Predictive Controller

  • Haeri, Mohammad;Zeinali, Mahdi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1975-1980
    • /
    • 2004
  • A parallel active power filter is designed and implemented to compensate for undesired current harmonics generated by a nonlinear load. The filter works based on PWM strategy and control signal is generated using a model predictive controller. To evaluate the achievements, a PI controller is also designed and implemented. Experimental results indicate about 50% increase in the efficiency over PI controller.

  • PDF

3상 UPS 인버터의 출력전압 왜형률 개선을 위한 고조파 보상기법의 DSP 제어 (DSP Control of Three-Phase UPS Inverter with Output Voltage Harmonic Compensator)

  • 변영복;조기연;박성준;김철우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.269-275
    • /
    • 1997
  • This paper presents real time digital signal processor(DSP) control of UPS system feeding processor(DSP) control of UPS system feeding nonlinear loads to provide sinusoidal inverter output voltage. The control scheme is composed of an rms voltage compensator, the load current harmonics feed-forward loop for the cancellation of output voltage harmonics, and the output voltage harmonics feedback loop for system stability. The controller employs a Texas Instruments TMS320C40GFL50 DSP.

  • PDF

연료전지 응용을 위한 HF Link 전류원 인버터 (HE Link Current-Fed Inverter for Fuel Cell Applications)

  • 정세교;신휘범;이현우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.17-20
    • /
    • 2003
  • This paper presents a high frequency (HF) link current-fed inverter fur fuel cell applications. The circuit topology, operation and control method of the proposed HF link current-fed inverter are presented. The active cancellation technique of the 120Hz input harmonic current is also considered. The simulation results are provided to show the feasibility of the proposed inverter scheme.

  • PDF

Harmonic Identification Algorithms Based on DCT for Power Quality Applications

  • Yepes, Alejandro G.;Freijedo, Francisco D.;Doval-Gandoy, Jesus;Sanchez, Oscar Lopez;Fernandez-Comesana, Pablo;Alvarez, Jano Malvar
    • ETRI Journal
    • /
    • 제32권1호
    • /
    • pp.33-43
    • /
    • 2010
  • The increasing demand for non-sinusoidal currents affects the quality of distribution networks. Harmonic detection is a crucial step in the cancellation of those components by active power filters. In this paper, the discrete cosine transform (DCT) is compared with different implementations based on Fourier transforms, demonstrating their equivalences and the advantages provided by the former. We demonstrate that the phase error in the presence of grid frequency deviations and the transient length are reduced by half in comparison to the discrete Fourier transform. A novel algorithm is developed to provide frequency adaptation to the DCT, taking advantage of its good features. The window width is adjusted in real time according to the actual value of the grid fundamental frequency by means of a phase-locked loop. A technique based on dithering is employed to overcome the limitation caused by the truncation of the window number of samples, so the frequency resolution is enhanced. The theoretical approach is verified by simulated and experimental results.

지역필터를 이용한 수변전실 접지저항의 새로운 측정방법 (A New Measurement Method of the Ground Resistance Using a Low-pass Filter in Energized Substations)

  • 이복희;엄주홍;이승칠;김성원;안창환
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권8호
    • /
    • pp.387-393
    • /
    • 2001
  • This paper describes an advanced measuring method and precise evaluation of the ground resistance for the grounding system of energized substations and power equipments. A grounding system of substations consists of all interconnected grounding connections of grounded conductors, neutral ground wires, underground conductors of distribution lines, cable shields, grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding system of high voltage energized substations because of harmonic components caused by switched power supplies or overloads. The conventional fall-of-potential method may be subject to big error if stray ground currents and potentials are present. In this work, to improve the precision in measurements of the ground resistance by eliminating the effects of harmonic components and stray currents and potentials, the investigations of the ground resistance measurement by using a low pass filter in a model energized grounding system were conducted. The accuracy of ground resistance mesurements was evaluated as a function of the ratio of the test signal to noise (S/N). The errors due to the proposed ground resistance measurement method were decreased with increasing S/N and were less than 5[%] as S/N is 10. The proposed ground resistance measurement method appears to be considerably more accurate than the conventional fall-of -potential method. It is allows cancellation of the parasitic resistance of energized grounding systems, to employ the measurement method that allows cancellation of the parasitic effects due to other circulating ground currents and ground potential rises in practical situations.

  • PDF