• Title/Summary/Keyword: hardness value

Search Result 2,599, Processing Time 0.023 seconds

Analysis of Influence Factors of Setting Time Estimation System for AI-Based Concrete Finishing Automation System (AI 기반 콘크리트 마감 자동화 시스템용 응결추정계의 영향인자 분석)

  • Han, Soo-Hwan;Hu, Yun-Yao;Kim, Su-Ho;Lim, Gun-Su;Kim, Jong;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.177-178
    • /
    • 2022
  • As part of the study on the development of the setting time estimation system, this study attempted to confirm the change in hardness values for each influencing factor variable and secure its reliability. According to the research results of this paper, the hardness value of the setting time estimation system tended to gradually decrease in the case of the hardness value of the closing time by curing temperature, and the hardness value increased in the concrete state compared to mortar. Therefore, further research on influencing factors will be conducted in consideration of material and statistical factors in the future.

  • PDF

Analysis of Sliding Wear Behavior of Mild Steel According to Hardness of Dissimilar Mating Materials (이종 상대재 경도에 따른 철강재료의 미끄럼 마모 특성 해석)

  • Lee, Han-Young
    • Tribology and Lubricants
    • /
    • v.32 no.6
    • /
    • pp.195-200
    • /
    • 2016
  • This study examines the wear behavior of mild steel pins mated against alloyed tool steel discs in a pin-on-disc type sliding test machine and provides specific clarification regarding the effects of disc hardness on the wear behavior of a mating mild steel pin. The analysis confirms these effects through the observation of differences in the wear rates of the mild steel pins at low sliding speed ranges. These differences occur even though the hardness of the mating disc does not affect the wear characteristic curve patterns for the sliding speeds, regardless of the wear regime. In the running-in wear regime, increasing the hardness of the mating disc results in a decrease in the wear rates of the mild steel pins at low sliding speed ranges. However, in the steady-state wear region, the wear rate of a pin mated against the 42DISC is greater than the wear rate of a pin mated against the 30DISC, which has a lower hardness value. This means that the tribochemical reactivity of the mating disc, which is based on hardness value, influences the wear behavior of mild steel at low sliding speed ranges. In particular, oxides with higher oxygen contents, such as $Fe_2O_3$ oxides, form predominantly on the worn surface of the 42DISC. On the contrary, the wear behavior of mild steel pins at high sliding speed ranges is nearly unaffected by the hardness of the mating disc.

The Effect of Test Variables on the Accuracy of Equo-Tip Hardness (Equo-Tip 경도값에 미치는 실험변수의 영향)

  • Nahm, S.H.;Jeon, S.B.;Kim, J.J.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.3 no.2
    • /
    • pp.32-36
    • /
    • 1990
  • For the accurate measurements of hardness in a material, it is necessary to have a thorough understanding of the effects of test variables on the accuracy of hardness value. For the rebound hardness test, major test variables are the radius of hammer ball tip, type of backing materials, size and roughness of the specimen. In this study, effects of these variables on Equo-Tip hardness value were investigated. Hardness measurements were carried out using WC balls with various sizes of worn-ot zone. The sample materials chosen for the experiments were commercial standard hardness blocks and SM45C steel bars subjected to either normalization or quench and temper treatments. As backing materials, aluminum, steel and rubber plates were used in all the experiments. Experimental results show that for the accurate measurements of Equo-tip hardness, it is necessary to use the hammer ball with a worn-out zone parameter of less than 0.23, and the recommended minimum thickness and width of the specimen are 25mm and 70mm, respectively. Further for the surface preparation, the specimens need to be polished with an emery paper of No. 400 or finer, and for the backing matrials, it is recommended to use steels or rubbers.

  • PDF

Analysis of Rolling Contact Fatigue of Ball Bearing with Various Hardness by X-ray Diffraction (BEARING소재 경도에 따른 구름접촉피로의 X선적 해석)

  • 이한영
    • Tribology and Lubricants
    • /
    • v.17 no.3
    • /
    • pp.209-215
    • /
    • 2001
  • In view of the effects of the hardness of material on fatigue, rolling contact fatigue process in hard metals seems to differ from it in soft metals. This paper has been aimed to compare the rolling contact fatigue process according to the hardness of materials. Rolling contact fatigue tests using the ball bearings assembled with the inner race of four different hardness have been carried out. In addition, residual stress and half-value breadth on/below the inner raceway during individual rolling contact fatigue have been measured by X-ray diffraction. The results of this study showed that the change of residual stress and half-value breadth during the rolling contact fatigue on race way in hard metals is the same as in soft metals. However, plastic deformation by rolling contact in hard metals is in microscopic scale but only for soft metals in macroscopic scale.

Effects of Heat Treatment Temperature and Cooling Method on Microstructure and Hardness of Cu-22Sn alloy (열처리 온도 및 냉각방법이 Cu-22Sn합금의 미세조직 및 경도변화에 미치는 영향)

  • Jeong, Museob;Shin, Ari;Han, Jun Hyun
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.31 no.3
    • /
    • pp.104-110
    • /
    • 2018
  • The effects of heat treatment time and cooling method on microstructure and mechanical property of Cu-22wt%Sn alloy were discussed. ${\alpha}+{\delta}$ mixed phase structure was obtained in air-cooled specimens after heat treatment at 775, 750, and $700^{\circ}C$ for 1 hour. On the other hand, in water-cooled specimens, ${\alpha}+{\beta}^{\prime}$ martensite mixed phase was obtained. In the case of water-cooled specimens, the hardness value decreased with decreasing heat treatment temperature because the volume fraction of ${\alpha}$ phase with low hardness value increased as the heat treatment temperature decreased. In water-cooled specimen after heat treatment at $600^{\circ}C$, ${\gamma}^{\prime}$ martensite was formed instead of ${\beta}^{\prime}$ martensite. The hardness value of ${\gamma}^{\prime}$ martensite was lower than those of ${\beta}^{\prime}$ and ${\delta}$ phases.

Effect of Austenitizing Temperatures on the Mechanical Properties in 420J2 Martensitic Stainless Steel (420J2 마르텐사이트계 스테인레스강의 오스테나이트화 온도가 기계적 성질에 미치는 영향)

  • Kim, Y.G.;Kim, Y.J.;Kim, G.D.;Sung, J.H.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.5 no.2
    • /
    • pp.111-121
    • /
    • 1992
  • For the purpose of investigating the effect of austenitizing temperatures on the mechanical properties of 0.23% C-13.6%Cr martensitic stainless steel, tensile properties, hardness, impact value and carbide extraction were examined after changing the austenitizing temperatures and tempering temperatures. The results obtained are summerized as follows. The carbide laminations formed from hot rolling before austenitization could not be eliminated after austenitizing at $950^{\circ}C$. With increasing austenitizing temperature, hardness increased and showed maximum value at $1050^{\circ}C$ and then slightly decreased. With increasing tempering temperature up to $500^{\circ}C$, impact value and elongation appeard to be decreased but hardness showed nearly unchanged at austenitizing temperature of $1150^{\circ}C$ due to the fine $M_7C_3$ carbides precipitation. The abrupt increase in impact value, hardness and elongation above the tempering temperature of $500^{\circ}C$ appeared to change in carbide structure from fine $M_7C_3$ to coarse $M_{23}C_6$.

  • PDF

Assessment of Paprika Quality by Instrumental Parameters and Sensory Attributes (파프리카 품종별 색상별 특성 비교를 위한 기기적, 관능적 품질 지표 평가)

  • Lee, Sun Mee;Kim, Ji-Sun;An, Chul Geon;Park, Jong-Suk;Kim, Suna
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.26 no.1
    • /
    • pp.34-43
    • /
    • 2016
  • This study was performed to improve the quality index of paprika by assessment of instrumental test and sensory attributes. Red paprika (11 cultivars), orange paprika (9 cultivars), and yellow paprika (10 cultivars) were provided by GyeongNam (GN) and JeonBuk Agricultural Research and Extension Services (JB). We measured hardness and color values using a colorimeter and TPA as well as developed new terminology such as cucumber taste, grass taste, green pepper flavor and appearance (size, color size, color, and glossiness), texture (hardness, juiciness), and taste (sweetness, pungency, sourness) to describe paprika quality attributes by trained panels. a* value of red 'Nagano' cultivar provided by JB was significantly low, and only b* value of orange paprika was significantly different among the samples. In the case of yellow paprika, b* values were not significantly different, and hardness was significantly different. Overall color values were different among samples provided by GN. Oranos, orange paprika, L value, b value, and hardness were different among the samples. Bitterness was negatively correlated with sweetness and positively correlated with green pepper aroma (p<0.05). Overall acceptability was positively correlated with size, juiciness, and sweetness (p<0.01) and negatively correlated with pungent (p<0.05) and bitterness (p<0.01). In conclusion, negative attributes such as bitterness and pungentness as well as positive attributes such as size, juiciness, and sweetness must be considered as important factors for consumer preference and breeding of new cultivars.

THE PHYSICAL PROPERTIES OF REUSED IPS EMPRESS CERAMIC PART IV : HARDNESS AND FRACTURE TOUGHNESS (반복 사용된 IPS Empress ceramic의 물리적 성질에 관한 연구 Part IV : 경도 및 파괴인성에 관한 연구)

  • Jin Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.4
    • /
    • pp.532-537
    • /
    • 2003
  • Statement of the problem : IPS Empress ceramic has been used as one of a esthetic restorative material since it's development, but the broad application of IPS Empress ceramic to clinical prosthodontic field has been limited by its high material cost. Purpose : This study was investigated to evaluate the hardness and fracture toughness after recycling of the IPS Empress ceramic. Material and methods : Reused specimens of IPS Empress were fabricated with repeated pressing. The hardness(Vickers hardness) and fracture toughness of 1st, 2nd and 3rd pressed specimens were measured with Digital Micro Hardness Tester(Model MXT70, Matsuzawa Seiki Co., Ltd, Tokyo, Japan). The obtained data were analyzed using SPSS(Ver 9.5). Result : The mean value of the hardness in the 1st, 2nd and 3rd pressed Empress were $6.23{\pm}0.48MPa,\;5.50{\pm}0.25MPa$, and $5.70{\pm}0.42MPa$. The hardness of the 1st pressing ceramic was higher than those or the 2nd and 3rd pressed ceramics(P<0.05). Hardness of the 3rd pressed ceramic was greater than that of the 2nd pressed ceramic. but there was no significant difference of hardness between those two(P>0.05). The mean value of the fracture toughness was $1.71{\pm}0.16MPam^{1/2}$ in 1st pressed ceramic, $1.78{\pm}0.10MPam^{1/2}$ in 2nd pressed and $1.73{\pm}0.14MPam^{1/2}$ in 3rd pressed IPS ceramic. Fracture toughness of the 2nd pressed ceramic was the highest and that of the 1st pressed ceramic was the lowest. There was no significant difference of fracture toughness among them(P>0.05). Conclusion : Hardness of the 2nd and 3rd pressed IPS Empress ceramics were lesser than that of 1st pressed IPS Empress ceramic(P<0.05), but there was no significant changes of fracture toughness among them(P>0.05).

Properties of Nimonic 80A Alloy with Change in the Chemical Compositions and Heat Treatment Paths (화학조성 및 열처리경로 변화에 따른 Nimonic 80A 합금의 특성)

  • Choi Byong-Kang;Jeong Hae-Yong;Bae Cha-Hurn
    • Korean Journal of Materials Research
    • /
    • v.15 no.12
    • /
    • pp.773-779
    • /
    • 2005
  • Properties of Ni-base superalloys of Nimonic 80A alloy system were investigated by the observation of microstructures, precipitates ana hardness as a function of the chemical compositions ana the paths of heat treatment. The higher hardness values showed, the higher Ti/Al ratio among high compositions of Cr and Co element. The lower (Ti+Al) and Fe contents decreased in the same Ti/Al ratio, the higher hardness values showed. This results are considered that coherent deformation was increased with increasing Ti/Al ratio. Hardness showed higher value when Cr contents was $18 wt\%$ less than $21wt\%Cr$. In $3.15 wt\%$Co alloy, $\gamma'$ phase was very fine as around 50nm and, its volume fraction and hardness showed the highest value by 2step-aging treatment.

Development of an Automatic Soil Hardness Measuring System Mountable on Agricultural Tractors (트랙터 부착형 자동 토양경도 측정 시스템 개발)

  • 이현동;김기대;김찬수;김성환
    • Journal of Biosystems Engineering
    • /
    • v.27 no.6
    • /
    • pp.537-546
    • /
    • 2002
  • In this study an automatic soil hardness measuring system mountable on agricultural tractors was developed to improve the accuracy of manual soil hardness testers by a constant penetrating rate, right direction of the cone-penetrometer and the isolation of vibration from the operator. This was necessary to supply similar experimental condition for performance test of new model and comparative experiment. The results of the study are summaried as follows; 1. The system consisted of a sensing part of soil hardness, a driving part of the measuring system and an attaching part between the tractor and the measuring system. 2. The allowable limit value of the system developed was set to 392N to protect from breaking the serve motor and the coupling used in this system. 3. The driving shaft penetrated into soil by 0.3m to measure soil hardness. The soil hardness was measured at the depth of 0.3m from the soil surface but the penetrating work was stopped and the driving shaft was pulled out to protect the system when the value of the soil hardness was too big on foreign substances like stones or straws. 4. Two values measured by automatic measuring system developed in this research and manual penetrometer were compared by statistics hypothesis testing method. When two people measured the soil hardness at the depth of 0.1 and 0.15m by manual cone penetrometer, there was no relationship between two values by two people but the values at the same depths by automatic measuring system developed showed similarity. The automatic system, therefore, developed in this research was proper for measuring soil hardness.