• Title/Summary/Keyword: hard-to-measure measurements

Search Result 30, Processing Time 0.025 seconds

Estimation of Hard-to-Measure Measurements in Anthropometric Surveys

  • Choi, Jong-Hoo;Kim, Ryu-Jin
    • Communications for Statistical Applications and Methods
    • /
    • v.9 no.1
    • /
    • pp.213-220
    • /
    • 2002
  • Anthropometric survey is important as a basis for human engineering fields. According to our experiences, there are difficulties in obtaining the measurements of some body parts because respondents are reluctant to expose. In order to overcome these difficulties, we propose a method for estimating such hard-to-measure measurements by using easy-to-measure measurements those are closely related to them. Multiple Regression Model, Feedforward Neural Network(FNN) Model and Projection Pursuit Regression(PPR) Model will be used as analytical tools for this purpose. The method we propose will be illustrated with real data from the 1992 Korea national anthropometric survey.

Comparison of asymmetric degree between maxillofacial hard and soft tissue in facial asymmetric subjects using three-dimensional computed tomography (안면비대칭자의 3차원 전산단층사진 분석에서 경$\cdot$연조직간 비대칭 정도 차이)

  • Kim, Wang-Sik;Lee, Ki-Heon;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.35 no.3 s.110
    • /
    • pp.163-173
    • /
    • 2005
  • The purpose of this study was to compare the asymmetric degree between maxillofacial hard and soft tissues in individuals with facial asymmetry. Computerized tomographies (CT) of 34 adults (17 male, 17 female) who had facial asymmetry were taken. The CT images were transmitted to personal computers and then reconstructed into three-dimensional (3D) images through the use of computer software. In order to evaluate the degree of facial asymmetry, 6 measurements were constructed as the hard tissue measurements while 6 counterpart measurements were taken as the soft tissue measurements. The means and standard deviations were obtained for each measurement using 3D measure, then t-test was used to investigate the differences between each hard tissue measurement and the corresponding soft tissue measurement All measurements used in the present study showed statistically significant differences between the hard and soft tissues. The degree of soft tissue asymmetry was smaller than that of corresponding hard tissue asymmetry in case of chin deviation, frontal ramal inclination difference, and frontal corpus inclination difference. On the other hand, the degree of soft tissue asymmetry was greater than that of underlying hard tissue asymmetry in the measurement of lip canting and lip cheilion height difference The present study suggests that asymmetric differences of hard and soft tissue is observed nu facial asymmetric subjects and thus soft tissue analysis is needed in addition to hard tissue analysis when making an evaluation of facial asymmetry.

Bias Estimation of Magnetic Field Measurement by AHRS Using UKF (UKF를 사용한 AHRS의 자기장 측정 편차 추정)

  • Ko, Nak Yong;Song, Gyeongsub;Jeong, Seokki;Lee, Jong-Moo;Choi, Hyun-Taek;Moon, Yong Seon
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.2
    • /
    • pp.177-182
    • /
    • 2017
  • This paper describes an unscented Kalman filter approach to estimate the bias in magnetic field measurements. A microelectromechanical systems attitude heading reference system (MEMS AHRS) was used to measure the magnetic field, together with the acceleration and angular rate. A magnetic field is usually used for yaw detection, while the acceleration serves to detect the roll and pitch. Magnetic field measurements are vulnerable to distortion due to hard-iron effect and soft-iron effect. The bias in the measurement accounts for the hard-iron effect, and this paper focuses on an approach to estimate this bias. The proposed method is compared with other methods through experiments that implement the navigation of an underwater robot using an AHRS and Doppler velocity log. The results verify that the compensation of the bias by the proposed method improves the navigation performance more than or comparable to the compensation by other methods.

The Effects of AFM Microcantilever Characteristics on the Non-Contact Mode Measurements (AFM 마이크로캔틸레버 특성에 따른 비접촉모드의 영향 고찰)

  • Hong, S.H.;Lee, S.I.;Lee, J.M.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1391-1395
    • /
    • 2006
  • In non-contact mode atomic force microscopy, the response of a resonating tip is used to measure the nanoscale topography and other properties of a sample surface. However, the tip-surface interactions can affect the tip response and destabilize the non-contact mode control. Especially it is difficult to obtain a good scanned image of high adhesion surfaces such as polymers using conventional hard NCHR tip and non-contact mode control. In this study, experimental investigation is made on the non-contact mode imaging and we report the microcantilever having low stiffness (OMCL) is useful to measure the properties of samples such as elasticity. In addition, we proved that it was adequate to use low stiffness microcantilever to obtain a good scanned image in AFM for the soft and high adhesion sample.

  • PDF

A Study of Optical Properties of Intraocular Lenses and of Measurement of the Index of Reflection for an Unknown Liquid

  • Joo, Won Don;Jung, Mee Suk
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.236-242
    • /
    • 2012
  • In general, such methods as interferometers or wavefront sensors are commonly used for testing of an optical system and optical components. In these cases, the surrounding environments are unlikely to affect the measurements. On the other hand, intraocular lenses of hydrophilic materials with special properties experience a certain difficulty in testing the optical properties. An intraocular lens is dried in the air, which causes deformation and changes the optical characteristics such as index of refraction and thickness. Thus, it is hard to measure the optical characteristics of an intraocular lens by using common methods. In this study, a special structure is used for measuring of the transmission wavefront aberration and effective focal length of an intraocular lens of hydrophilic materials by using a Shark-Hartmann sensor among the various measuring methods. As an application of this measuring method, this study shows a simple method to measure the index of refraction of unknown liquids with a plano-convex lens with a well known index of refraction. Also, this method is used to measure the optical properties of a plano-convex such as index of refraction and curvature by using a liquid with a well known index of refraction.

Nondestructive Measurement of Cheese Texture using Noncontact Air-instability Compensation Ultrasonic Sensors

  • Baek, In Suck;Lee, Hoonsoo;Kim, Dae-Yong;Lee, Wang-Hee;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • v.37 no.5
    • /
    • pp.319-326
    • /
    • 2012
  • Purpose: Cheese texture is an important sensory attribute mainly considered for consumers' acceptance. The feasibility of nondestructive measurements of cheese texture was explored using non-contact ultrasonic sensors. Methods: A novel non-contact air instability compensation ultrasonic technique was used for five varieties of hard cheeses to measure ultrasonic parameters, such as velocity and attenuation coefficient. Five texture properties, such as fracturability, hardness, springiness, cohesiveness, and chewiness were assessed by a texture profile analysis (TPA) and correlated with the ultrasonic parameters. Results: Texture properties of five varieties of hard cheese were estimated using ultrasonic parameters with regression analysis models. The most effective model predicted the fracturability, hardness, springiness, and chewiness, with the determination coefficients of 0.946 (RMSE = 21.82 N), 0.944 (RMSE = 63.46 N), 0.797 (RMSE = 0.06 ratio), and 0.833 (RMSE = 17.49 N), respectively. Conclusions: This study demonstrated that the non-contact air instability compensation ultrasonic sensing technique can be an effective tool for rapid and non-destructive determination of cheese texture.

Conformity Assessment of Color Measurement Methods (색도 측정방법의 적합성 평가)

  • Jeong, Gwanjo;Jo, Bumsu;Song, Mahnshik;Park, Hyeon;Lee, Jonggyu;Choi, Youngjune
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.6
    • /
    • pp.442-448
    • /
    • 2013
  • There are two approaches in measuring colors (or chromaticity) in water, i.e., visual comparison method and spectrophotometric method. The color of sample was determined by comparing with that of platinum-cobalt standard solution in the visual comparison method. Single or multiple wavelengths are used for the spectrophotometric method. As the accuracy and precision of visual comparison method depend on the eye sight of the analyzer, the results are not so reliable and representative. In addition, it is hard to measure chromaticity less than 5 TCU. Single wavelength approach in spectrophotometric method, can be applied for groundwater or surface water with natural organic matter (i.e., humic substances) while it's hard to measure the color of wastewater which includes anthropogenic chemical compounds. The measurements with multiple wavelengths approach resulted in reliable data regardless of the source of sample water, i.e., surface water and wastewater. As dozens of measurements and complicated calculations for one sample were required for the multiple wavelengths approach, the approach could not be applied for field measurement. In the present study, the authors tested efficient method which could measure the color of water sample accurately and precisely regardless of the source of water. With the colorimeter with multiple wavelengths and calculation program, the colors of water samples could be measured within 3~4 seconds with accuracy and precision.

Design and Verification of a Wave Gauge Using Digital Images (디지털 영상을 이용한 파고계 개발 및 검증)

  • Kim Taerim
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.16 no.3
    • /
    • pp.171-177
    • /
    • 2004
  • A new wave gauge using digital image of waves is developed and the performances are tested by wave tank experiments. This wave gauge uses frame frequency of 1/15 sec, conversion of analog images to digital images, and large capacity of hard disk. This wave gauge measures wave heights by detecting the buoy movement automatically from the image, where the buoy moves with the same phase of water surface. The comparison of automatic measurements of wave heights to the true data is reasonable. The wave gauge can be improved to measure wave heights on shallow waters near shorelines.

Bubble Wake Measurement by Acoustic Bubble Spectrometer Generated by Planing Hull at Circulating Water Channel (회류수조에서의 ABS에 의한 활주선 후류 기포항적계측)

  • Shin, Myung-Soo;Moon, Il-Sung;Nah, Young-In;Park, Jong-Chun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.55-61
    • /
    • 2011
  • This paper presents bubble wake measurement results generated by the planing hull. The bubble was generated by SNAME TMB model(No. 4876) with hard chine at the CWC(Circulating Water Channel). ABS(Acoustic Bubble Spectrometer) was used to measure bubble wake measurement. The manufactured model is one meter in length and uniform velocity to generate the bubble at CWC is 3m/s, relatively higher speed than conventional hull form. Measurements were performed successfully and measured results show well the general characteristics of bubble wake generated by planing hull. Furthermore, experimental equations are proposed for the practical use.

Research on the emission of electromagnetic waves in ambulance (구급차량 내 전자파 방출에 관한 조사)

  • Yun, Jong-Geun
    • The Korean Journal of Emergency Medical Services
    • /
    • v.23 no.1
    • /
    • pp.61-69
    • /
    • 2019
  • Purpose: The study aims to provide basic data to enhance the health of paramedics responsible for patient transport and treatment by analyzing the exposure level of paramedics to electromagnetic waves generated by electric devices used in ambulances. Methods: The study measured electromagnetic waves in ambulances in N region from July to December 2018. ME3030B produced by German Gigahertz Solutions was used to measure these waves and the maximum value was selected by moving it slowly in various directions. Each measurement part was selected and the mean value was calculated by repeatedly measuring at 10-minute intervals three times in total: $1^{st}$, $2^{nd}$, and $3^{rd}$ phase. Results: Among the electrical devices installed in the patient room of the ambulance measured at distances of 1 cm or 30 cm, results showed a high level of electric waves at the inverter ($26.25{\pm}39V/m$) and high level of electromagnetic waves ($564.00{\pm}31.75nT$) at the ozone sterilizer. According to measurements toward the front near the driver's seat, results indicated high levels of electric waves ($3.67{\pm}1.15V/m$) and electromagnetic waves ($450.00{\pm}19.52nT$) at the black box hard drive. Conclusion: Electromagnetic waves within the ambulance were stable and not beyond the range that might impact human health. However, in the case of the black box hard drive ($3.67{\pm}1.15V/m$, $450.00{\pm}19.52nT$) located under the passenger seat, it may have a direct effect on the human body and, thus it is necessary to move it to a storage area further away from the paramedics to minimized the impact.