• Title/Summary/Keyword: hand size

Search Result 1,971, Processing Time 0.022 seconds

Analysis on Hand Types of Elderly Women (노년층 여성의 손 유형 분석)

  • Choi, Eun-Hee;Do, Wol-Hee
    • Fashion & Textile Research Journal
    • /
    • v.15 no.4
    • /
    • pp.574-582
    • /
    • 2013
  • This study categorizes and analyzes hand types based on 2-Dimensional measurements of women in their 60-80's in order to establish initial data that can help develop a well-fitted glove and hand protector for elderly women. A total of 22 measurement items were selected to provide information about Size Korea (2010) 3D hand measurements. Participants in the study were 353 elderly women over the age of 60. Subjects were divided into two age groups (60's and over 70's). Statistical tests (such as Descriptive Analysis and T-test) analyzed the data and ascertained the age differences. A factor analysis and cluster analysis were conducted to classify elderly women hand types. The disparities between 20-30's and over 60's age groups were compared by T-test with the SPSS 20 program for Windows. The results in this study are follows: The hand shapes for elderly women were divided into 3 groups. Elderly women's Hand Type A is average length and the medium breadth hand type. Type B is the biggest length and breadth, Type C is the smallest length and breadth hand type. There were significant differences in the 20-30's and over 60's age groups for most hand length and breadth items. In addition, the mean measurement value of the length items decreased as the age increased; however, the diversity of items increased, so that it became shorter and wider. Further study should include the classification of hand shape dimensions for each figure type of sizing gloves for elderly women. We expect hand types to be applicable to the manufacture of gloves for elderly women.

An Analysis of Mobile Display Industries (모바일 디스플레이산업 분석)

  • 배상진
    • Journal of Korea Technology Innovation Society
    • /
    • v.5 no.3
    • /
    • pp.396-411
    • /
    • 2002
  • This is an analysis of international mobile displays industry. There has been severe competition in market and technology. In technology, There has been competition between Japan, USA and Korea. On the other hand, there has been competition in the products market between Korea, Japan and Taiwan. Recently Korea has catched-up Japan in mid-size display industry. The response of Japanese firms are as follows: technological collaboration with Taiwanese firms in mid-size and concentration in small and large size displays. New competition, however, has started, since new technologies such as TFT-LCD and OELD have been used in products.

  • PDF

Food Sources of Thiamin, Riboflavin and Niacin Based on Food Composition Table and National Annual Food Supply Data in Food Balance Sheet (우리 나라 식품수급표 자료을 분석한 티아민, 리보플라빈, 나이아시신의 주요 급원식품)

  • 김영남;나현주
    • Journal of Nutrition and Health
    • /
    • v.34 no.7
    • /
    • pp.809-820
    • /
    • 2001
  • The purpose of the study was to find out the rich sources of vitamin B-complexes in Korea. Thirty kinds of vitamin B-complex (thiamin, riboflavin, and niacin) rich foods were selected based on vitamin content in 100g edible portion, single serving size, 100kcal energy content, and 1999 national annual food supply data. The results were summarized as follows: \circled1 Most of the thiamin rich foods selected were fishes: half of the foods selected was fishes when based on the contents in single serving size. On the other hand, about half of the foods selected were vegetables when based on the thiamin contents in 100kcal energy content. A relatively large number of food groups were included such as fishes, vegetables, beans, grains, meats, etc. when based on the contents in 100g edible portion, and national food supply data. \circled2 Most of the riboflavin rich foods selected were fishes and shellfishes, and vegetables: half of the foods selected were fishes and shellfishes when based on the content in 100g edible portion; two-thirds of the foods selected were vegetables when based on the content in single serving size; half of the foods selected were vegetables when based on the content in 100kcal. \circled3 The most important niacin sources are fishes: Most than 60% of the foods selected were fishes when based o the 100g edible portion, single serving size, and 100kcal energy content. Laver is very important source of all 3 vitamin B-complexes in Korea when based on the content in 100g edible portion, 100kcal energy content, and national annual food supply but not in single serving size. On the other hand, rice is rice is sources of all 3 vitamin B-complexes when based on the national annual food supply, but not in single serving size. On the other hand, rice sources of all 3 vitamin B-complexes when based on the national annual food supply, but is not included in 30 rich foods selected based on the content in 100g edible portion, single serving size, and 100kcal energy content. Mushrooms are also very important food sources of thiamin, riboflavin, and niacin when based on the vitamin content in 100g edible portion, single serving size, and 100kcal energy content but not included in 10 rich food selected based on the national food supply data.

  • PDF

An Implementation of Real-Time Numeral Recognizer Based on Hand Gesture Using Both Gradient and Positional Information (기울기와 위치 정보를 이용한 손동작기반 실시간 숫자 인식기 구현)

  • Kim, Ji-Ho;Park, Yang-Woo;Han, Kyu-Phil
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.2 no.3
    • /
    • pp.199-204
    • /
    • 2013
  • An implementation method of real-time numeral recognizer based on gesture is presented in this paper for various information devices. The proposed algorithm steadily captures the motion of a hand on 3D open space with the Kinect sensor. The captured hand motion is simplified with PCA, in order to preserve the trace consistency and to minimize the trace variations due to noises and size changes. In addition, we also propose a new HMM using both the gradient and the positional features of the simplified hand stroke. As the result, the proposed algorithm has robust characteristics to the variations of the size and speed of hand motion. The recognition rate is increased up to 30%, because of this combined model. Experimental results showed that the proposed algorithm gives a high recognition rate about 98%.

Hand Reconstruction Using Anterolateral Thigh Free Flap by Terminal Perforator-to-Digital Artery Anastomosis: Retrospective Analysis

  • Jin Soo Kim;Ho Hyung Lee;Sung Hoon Koh;Dong Chul Lee;Si Young Roh;Kyung Jin Lee
    • Archives of Plastic Surgery
    • /
    • v.51 no.1
    • /
    • pp.87-93
    • /
    • 2024
  • This study aimed to analyze cases of anterolateral thigh (ALT) free flap used for hand reconstruction with terminal perforator-to-digital artery anastomosis. Patients who underwent ALT free flap placement with terminal perforator-to-digital artery anastomosis for hand reconstruction between January 2011 and August 2021 were included. The number, length, and diameter of the perforators and veins, flap size, and operative time were investigated through a retrospective review of charts and photographs. The occurrences of arterial thrombosis, venous thrombosis, arterial spasm, and flap necrosis were analyzed. In total, 50 patients were included in this study. The mean diameter and length of the perforators were 0.68 mm and 3.25 cm, respectively, and the mean number of veins anastomosed was 1.88, with a mean diameter of 0.54 mm. Complications included four cases of arterial thrombosis, one case of venous thrombosis, seven cases of partial necrosis, and one case of total flap failure. Regression analysis showed that a longer perforator was associated with arterial thrombosis whereas larger flap size and number of anastomosed veins were associated with partial necrosis (p < 0.05). The terminal perforator-to-digital artery anastomosis offers advantages in using compact free flaps with short pedicle lengths to cover small hand defects.

Development of Analytical Method for Microplastics in Seawater (해수에 잔류하는 미세플라스틱의 정성정량 분석법 확립)

  • Chae, Doo-Hyun;Kim, In-Sung;Song, Young Kyoung;Kim, Sungwoo;Kim, Seung-Kyu
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.19 no.1
    • /
    • pp.88-98
    • /
    • 2014
  • Despite of emerging and increasing concerns to microplastics, no standard methodology has not been proposed for determination of microplastics. This study aims to develop the analysis method for microplastics in seawater by overviewing methodologies proposed by previous studies and by assessing some processes in those methodologies which possibly cause uncertainties in microplastic determination. Furthermore, we present preliminary results of distribution characteristics of microplastics in seawater of Incheon/Kyeonggi coastal region which is based on our new methodology. Microplastics in surface microlayer (SML) and subsurface water (SSW) were collected using mesh screen and planktonic nets (trawl net with $330{\mu}m$ mesh size and hand net with $20{\mu}m$ mesh size), respectively. Microplastics with < $300{\mu}m$ was predominant, indicating hand net as the better collection tool for SSW. As for SML, FT-IR based microplastic concentration was well matched with naked-eye based concentration which has been used in most of previous studies. However, a poor relationship was observed for SSW, indicating that concentration data of previous SSW studies should be corrected. Incheon/Kyeonggi bay seawater contained the similar concentration range with those in coastal region of the Nakdong River. Our methodology can be used as a basic tool for further microplatic studies.

The Study of Kinetic Visual Acuity in College Students (대학생의 동적시력에 관한 연구)

  • Shim, Moon-Sik;Kim, Sang-Hyun;Kang, Hye-Sook;Shim, Hyun-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.4
    • /
    • pp.419-424
    • /
    • 2012
  • Purpose: We were to obtain the basic data for studying kinetic visual acuity through the comparative analysis in kinetic visual acuity, visual acuity, refractive error, pupil size, and hand reaction time for college students. Methods: We had tested the kinetic visual acuity, visual acuity, refractive error and hand reaction time using the kinetic visual acuity tester (KOWA AS-4A), the hand reaction time program and auto-refractometer for thirty-nine male and same female optometry students with more than +0.1 LogMAR visual acuity in both eyes. And the results were examined gender differences of kinetic visual acuity and the factors correlation. Results: In the measured values of male, pupil size were 6.00 mm, hand reaction time 0.23 msec, refractive error -1.66 D, visual acuity -0.07, kinetic visual acuity 0.59 and pupil size 5.86 mm, hand reaction time 0.24 msec, refractive error -2.08 D, visual acuity -0.02, kinetic visual acuity 0.46 in female. It was significant difference for kinetic visual acuity values but other factors were not. The kinetic visual acuity and left visual acuity had the highest correlation, r=-0.406. The kinetic visual acuity indicated more excellent values in the case of increasing visual acuity and decreasing myopia amount. Conclusions: It was able to see that male college students were better than female for kinetic visual acuity and the visual acuity were related to kinetic visual acuity.

Development of Dry-type Active Surface EMG Electrode for Myoelectric Prosthetic Hand (근전의수용 건식형 능동 표면 근전도 전극의 개발)

  • 최기원;문인혁;추준욱;김경훈;문무성
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2733-2736
    • /
    • 2003
  • This paper proposes a dry-type active surface EMG electrode for the myoelectric prosthetic hand. The designed electrode is small size for embedding in the socket of prosthetic hand, and it has three leads including the reference of signal. To acquire EMG signal rejected the power noise, a precision differential amplifier and various filters such as the band pass filter band rejection filter, low pass and high pass filter are embedded on the electrode. The final output of the electrode is integrated absolute EMG (IEMG) obtained by full rectifier and moving average circuits. From experimental results using the implemented dry-type active surface EMG electrode, the proposed electrode is feasible for the myoelectric prosthetic hand.

  • PDF

Ergonomic Factors Assessment on Hand Tool Handle (수공구 손잡이의 인간공학적 요소 평가)

  • Yang Sung-Hwan;Cho Mun-Son;Kang Young-Sig
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.1
    • /
    • pp.43-52
    • /
    • 2006
  • The goal of this study is to investigate the ergonomic factors in designing or selecting the hand tool handle. Electromyogram (EMG) were measured for various wrist postures and handle sizes under two loading conditions. Anthropometric data were measured and the correlation with EMG measurement data were analyzed. Investigations of this study show that wrist posture should be neutral for minimum muscle tension and optimum handle size can be found by measuring the EMG measurement data. It show that hand width and EMG measurement data is greatly correlated also. This study can be a guide of designing or selecting a hand tool, but further study with large sample sizes and various groups is needed for making general conclusion.

A New Ultrasound Bladder Scanner to Estimate Urine Volume Using Hand-Motion Scan (손 동작 스캔을 이용한 잔뇨량 측정용 초음파 방광 스캐너)

  • Lee, Jung Hwan;Bae, Jung Ho;Lee, Soo Yeol;Cho, Min Hyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.4
    • /
    • pp.153-160
    • /
    • 2018
  • 3D ultrasound bladder scanners are getting popular in hospitals for the patients with bladder dysfunction. A current bladder scanner adopts a mechanical scan to acquire 3D images and requires two motors and complicated mechanical devices. In this paper, we propose a new ultrasound bladder scanner using hand-motion scan. Instead of two motors and mechanical devices, it has a motion sensor to record transducer positions during hand-motion scan. The experiments with a bladder phantom and volunteers showed similar measurement accuracy to a conventional 3D ultrasound bladder scanner. We expect that the proposed method will reduce the cost and size of the bladder scanner.