• 제목/요약/키워드: hand condensation

검색결과 59건 처리시간 0.027초

강인한 손가락 끝 추출과 확장된 CAMSHIFT 알고리즘을 이용한 자연스러운 Human-Robot Interaction을 위한 손동작 인식 (A Robust Fingertip Extraction and Extended CAMSHIFT based Hand Gesture Recognition for Natural Human-like Human-Robot Interaction)

  • 이래경;안수용;오세영
    • 제어로봇시스템학회논문지
    • /
    • 제18권4호
    • /
    • pp.328-336
    • /
    • 2012
  • In this paper, we propose a robust fingertip extraction and extended Continuously Adaptive Mean Shift (CAMSHIFT) based robust hand gesture recognition for natural human-like HRI (Human-Robot Interaction). Firstly, for efficient and rapid hand detection, the hand candidate regions are segmented by the combination with robust $YC_bC_r$ skin color model and haar-like features based adaboost. Using the extracted hand candidate regions, we estimate the palm region and fingertip position from distance transformation based voting and geometrical feature of hands. From the hand orientation and palm center position, we find the optimal fingertip position and its orientation. Then using extended CAMSHIFT, we reliably track the 2D hand gesture trajectory with extracted fingertip. Finally, we applied the conditional density propagation (CONDENSATION) to recognize the pre-defined temporal motion trajectories. Experimental results show that the proposed algorithm not only rapidly extracts the hand region with accurately extracted fingertip and its angle but also robustly tracks the hand under different illumination, size and rotation conditions. Using these results, we successfully recognize the multiple hand gestures.

Condensation Heat Transfer and Pressure Drop of R-134a in the Oblong Shell and Plate Heat Exchanger

  • Park Jae-Hong;Kim Young-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권3호
    • /
    • pp.158-167
    • /
    • 2004
  • Condensation heat transfer experiments were conducted with a oblong shell and plate heat exchanger without oil in a refrigerant loop using R-134a. An experimental refrigerant loop has been developed to measure the condensation heat transfer coefficient $h_r$ and frictional pressure drop ${\Delta}p_f$ of R-134a in a vertical oblong shell and plate heat exchanger. Four vertical counter flow channels were formed in the oblong shell and plate heat exchanger by four plates having a corrugated sinusoid shape of a $45^{\circ}$ chevron angle. The effects of the refrigerant mass flux, average heat flux, refrigerant saturation temperature and vapor quality were explored in detail. Similar to the case of a plate heat exchanger, even at a very low Reynolds number, the flow in the oblong shell and plate heat exchanger remains turbulent. The results indicate that the condensation heat transfer coefficients and pressure drops increase with the vapor quality. A rise in the refrigerant mass flux causes an increase in the $h_r\;and\;{\Delta}p_f$. Also, a rise in the average heat flux causes an increase in the $h_r$. But the effect of the average heat flux does not show significant effect on the ${\Delta}p_f$. On the other hand, at a higher saturation temperature, both the $h_r\;and\;{\Delta}p_f$. found to be lower. Based on the present data, the empirical correlations are provided in terms of the Nusselt number and friction factor.

Ordered Fragmentation of pDNA induced by PEG-PLL block copolymer -Correlation between Condensation degree and Biological Activity by Cell-Free System-

  • Osada, Kensuke;Doi, Motoyoshi;Shiotani, Tomonori;Yamasaki, Yuichi;Kataoka, Kazunori
    • 한국고분자학회:학술대회논문집
    • /
    • 한국고분자학회 2006년도 IUPAC International Symposium on Advanced Polymers for Emerging Technologies
    • /
    • pp.254-254
    • /
    • 2006
  • The sensitivity of plasmid DNA (pDNA) to S1 nuclease, an enzyme to cleave a single-strand DNA, was dramatically modulated through a supramolecular assembly (polyion complex micelle) with a synthetic block copolymer, poly(ethylene glycol)-b-poly(L-lysine) (PEG-PLL). The pDNA condensed in stoichiometric charge ratio was cleaved into 7 fragments each being 10/12, 9/12, 8/12, 6/12, 4/12, 3/12, and 2/12 of the original DNA length, on the other hand, the pDNA condensed in higher charge ratios (>4), were digested into non-specific manner. Condensation of the pDNA was investigated from two viewpoints that how does the rigid DNA molecules fold and condense and how does the condensation influence their biological activity.

  • PDF

가스응축장치 캐리어가스 공급속도 및 압력변화를 통한 비스무스 나노분말 입도제어 (Size Control of Bismuth Nanoparticles by Changes in Carrier-Gas Flow Rate and Chamber Pressure of Gas Condensation Apparatus)

  • 이경자;김창규;이민구;이창규
    • 한국분말재료학회지
    • /
    • 제17권5호
    • /
    • pp.379-384
    • /
    • 2010
  • In the present work, bismuth nanopowders with various particle size distributions were synthesized by controlling argon (Ar) gas flow rate and chamber pressure of a gas condensation (GC) apparatus. From the analyses of transmission electron microscopy (TEM) images and nitrogen gas adsorption results, it was found that as Ar gas flow rate increased, the specific surface area of bismuth increased and the average particles size decreased. On the other hand, as the chamber pressure increased, the specific surface area of bismuth decreased and the average particles size increased. The optimum gas flow rate and chamber pressure for the maximized electrochemical active surface area were determined to be 8 L/min and 50 torr, respectively. The bismuth nanopowders synthesized at the above condition exhibit 13.47 $m^2g^{-1}$ of specific surface area and 45.6 nm of average particles diameter.

열전달 촉진관에서 CFC-11 및 CFC-12 대체냉매의 응축 열전달 특성 연구 (Condensation heat transfer characteristics of alternative refrigerants for CFC-11, CFC-12 for enhanced tubes)

  • 조성준;황수민;정동수;김종보
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.569-580
    • /
    • 1998
  • In this study, condensation heat transfer coefficients(HTCs) of a plain tube, low fin tube, and Turbo-C enhanced tube for CFC-11, HCFC-123, CFC-12, HFC-l34a are measured and compared against each other. All data are taken at the vapor temperature of 39$^{\circ}C$ with a wall subcooling temperature 3~8$^{\circ}C$. Test results show that HTCs of a low vapor pressure refrigerant, HFC-123, for a plain, low fin, and Turbo-C tubes are 10.5~20.5%, 8.2~12.2%, 16.5~19.2% lower than those of CFC-11, respectively. On the other hand, HTCs of a medium vapor refrigerant, HFC-l34a, for a plain, low fin, and Turbo-C tubes are 20.6~31.8%, 0.0~8.0%, 13.2~20.9% higher than those of CFC-12, respectively. For all refrigerants tested, HTCs of Turbo-C tube are the highest among the three tubes showing almost 8 times increase in HTCs as compared to those of a plain tube. Nusselt's prediction equation for a plain tube yielded 12% deviation for all plain tube data while Realty and Katz's prediction equation for a low fin tube yielded 20% deviation for all low tube data.

  • PDF

2-Arylethenylchronlones유도체의 합성 및 항암활성 검색 (2-Arylethenylchromone Derivatives : Synthesis and Anticancer Activity)

  • 문창상;이경원;이지용;이재열;정봉영;이경태;이용섭
    • 약학회지
    • /
    • 제47권6호
    • /
    • pp.376-381
    • /
    • 2003
  • 2-Arylchromones, also known as flavones, are among the most ubiquitous classes of natural products occurring in the plant kingdom. On the other hand, 2-styrylchromones are relatively scarce in nature and only a few compounds has been isolated from the blue-green algae species. Therefore, new 2-arylethenylchromone derivatives ( 4a∼n, 5a∼f) were synthesized by the aldol condensation of 2-methylchromone ( 3) with several aromatic aldehydes in order to evaluate their cytotoxicities using a MTT assay on three tumor cells. 2-Arylethenylchromone derivative 4a showed the significant cytotoxic activities on KB, HL-60 and P-388 cell lines with $IC_{50}$/ values of 25.2, 63.59 and 49.51 $\mu$M, respectively, indicating that 2-arylethenylchromone skeleton has a potential anti-tumor application.

증발과 응결에 대한 국민 학생들의 개념 조사 (Children's Conception on Evaporation and Condensation)

  • 최병순;김효남;강순희;신인철
    • 한국과학교육학회지
    • /
    • 제13권1호
    • /
    • pp.92-99
    • /
    • 1993
  • The purpose of this study was to investigate and analyze the conception of elementary school students on evaporation and condensation, and then to verify the types of the conception. Forty-eight children from six elementary schools were sampled by stratified random sampling in Seoul and other provinces. They responded to the questionaire and the interview. This study was carried out according to the process of the basic study, the preliminary study, and the main study. The materials collected were classified and analyzed according to the types of children's ideas. The findings of this study were as follows. 1. The vocabulary used to describe the evaporation phenomena varied according to the situations, and the scientific term "evaporation" was more frequently used by the older groups. 2. Most children answered that the last location of water were air/sky/cloud. Air/cloud which represents the scientific conception of the location of water were mentioned by children of all ages. The higher the grade of the children were, the more scientific conception the children mentioned, however. 3. Most children referred to the heat as the factor of evaporation. Wind, on the other hand was mentioned by less than 10% of lower graders, and by about 30% of higher graders. 4. The result of asking children whether they thought it was possible to get the evaporated water back showed that about 70% of lower graders denied the possibility of the water being reversible. About 60% of higher graders. however, recognized that the water will be returned as rain or condensation. This increase may be associated with formal teaching of water cycle. 5. In the ideas of evaporation and condensation, some of the children have supernatural ideas and animism, which are most younger chilren's characteristics.

  • PDF

평관과 마이크로 핀관 내 R22, R134a, R407C, R410A의 흐름응축 열전달성능 (Flow Condensation Heat Transfer of R22, R134a, R407C, and R410A in Plain and Microfin Tubes)

  • 조영목;박기호;송길흥;정동수
    • 설비공학논문집
    • /
    • 제14권8호
    • /
    • pp.656-663
    • /
    • 2002
  • Flow condensation heat transfer coefficients (HTCs) of R22, R134a, R407C, and R410A were measured on horizontal plain and microfin tubes. The experimental apparatus was composed of three main parts; a refrigerant loop, a water loop and a water/glycol loop. The test section in the refrigerant loop was made of both a plain and a microfin copper tube of 9.52 mm outside diameter and 1.0 m length. The refrigerant was cooled by passing cold water through an annulus surrounding the test section. Tests were performed at a fixed refrigerant saturation temperature of $40^{\circ}C$ with mass fluxes of 100, 200, and 300 kg/$m^2s$. Test results showed that at similar mass flux the flow condensation HTCs of R134a were similar to those of R22 for both plain and microfin tubes. On the other hand, HTCs of R407C were lower than those of R22 by 11~l5% and 23~53% for plain and microfin tubes respectively. And HTCs of R410A were similar to those of R22 for a plain tube but lower than those of R22 by 10~21% for a microfin tube. In general, HTCs of a microfin tube were 2.0~3.0 times higher than those of a plain tube.

Role of KOH in the One-Stage KOH Activation of Cellulosic Biomass

  • Oh, Gyu-Hwan;Yun, Chang-Hun;Park, Chong-Rae
    • Carbon letters
    • /
    • 제4권4호
    • /
    • pp.180-184
    • /
    • 2003
  • The role of KOH in the one-stage KOH-activation of rice straws was studied using FTIR, XPS, TGA, and DTG techniques. It was found that at the impregnation, KOH extracts to some extent the lignin component from rice straw and reacts with hydroxyl groups. On heat-treatment, the impregnated KOH facilitates intermolecular condensation reaction on one hand but retards the thermal degradation of cellulose molecules on the other hand. The oxygen-containing surface functional groups newly created by oxidation of KOH may facilitate the bulk, not controlled, consumption of carbon atoms so that the effective porosities may not be able to be developed by the one-stage activation process.

  • PDF

천음속 익형 유동에서 비평형 응축이 Drag Divergence Mach Number에 미치는 영향에 관한 수치 해석적 연구 (Numerical Study on the Effect of Non-Equilibrium Condensation on Drag Divergence Mach Number in a Transonic Moist Air Flow)

  • 최승민;강희보;권영두;권순범
    • 대한기계학회논문집B
    • /
    • 제40권12호
    • /
    • pp.785-792
    • /
    • 2016
  • 본 연구에서는 NACA0012 천음속 익형 유동에 있어 비평형 응축이 항력 발산 마하수 $M_D$에 미치는 영향을 TVD 유한 차분법을 사용하여 연구하였다. 받음각 ${\alpha}$가 동일한 경우, 정체점 상대습도 ${\phi}_0$가 높을수록 충격파 직전의 최대 마하수 $M_{max}$는 작게 되고 초음속 영역의 크기도 적게 된다. 주류 마하수 $M_{\infty}$, 정체점 상대습도 ${\phi}_0$ 및 정체온도 $T_0$가 동일한 경우 받음각 ${\alpha}$가 클수록 비평형 응축영역 길이 ${\Delta}_z$은 짧게 된다. 한편, 주류 마하수 $M_{\infty}$와 받음각 ${\alpha}$가 동일한 경우 정체점 상대습도 ${\phi}_0$가 높을수록 조파저항의 감소 때문에 항력계수 $C_D$는 적어진다. $M_D$${\alpha}$가 동일한 경우 ${\phi}_0$가 클수록 크게 되며, ${\phi}_0$가 동일한 경우는 ${\alpha}$가 클수록 $M_D$는 적게 된다.