• Title/Summary/Keyword: half-order

Search Result 1,785, Processing Time 0.032 seconds

A Study on Comparions of Ice Bag and Heat Lamp for the Relief of Perineal Discomfort. (회음부 불편감 완화를 위한 냉요법과 온요법의 비교연구)

  • 남혜경;박영숙
    • Journal of Korean Academy of Nursing
    • /
    • v.21 no.1
    • /
    • pp.27-40
    • /
    • 1991
  • Perineal discomfort from episiotomy continues to be a problem for many postpartum women. The purposes of this study were to compare the effect of ice bag and heat lamp for the relief of perineal discomfort and to identify the sustaining time of each effect. Forty women took ice bag and heat lamp with random assignment of initial therapy. Women rated the degree of perineal discomfort before and after each therapy and at half-hour, tow-hour and four-hour intervals after each therapy. A discomfort scale, 18cm graphic rating scale, was used. The results of the study were as follows ; 1. The ice bag group showed significantly lower discomfort score than the heat lamp group at the half- hour and two - hour intervals after therapy. 2. The ice bag group showed significantly lower discomfort score for 4hrs after than before therapy, but the heat lamp group did not show significantly lower discomfort score. 3. Neither the type of episiotomy nor the previous experience of heat therapy influenced on the effect of ice bag relieving the perineal discomfort. Therefore ice bag was significantly mere effective in relieving perineal discomfort than heat lamp. Subjective responeses of patients who took both therapy were very favorable toward ice bag. I suggested that nurses should provide women with adequate information about the use of ice bag and encourage to apply ice bag instead of heat lamp after episiotomy in order to promote the relief of perineal discomfort and the healing of perineal wound.

  • PDF

Discovery of Giant Magnetostriction in Amorphous RFe$_2$B (R = Sm, Tb) Alloys

  • Kim, Jai-Young
    • Journal of Magnetics
    • /
    • v.1 no.2
    • /
    • pp.64-68
    • /
    • 1996
  • Compared with the conventional magnetostriction in Ni alloys which are in the order of several tens ppm (Parts Per Million =10-6), RFe$_2$(R = rare earth element) Laves Phase intermetallic compounds show large saturation magnetostriction in the range of a few thousands ppm. However, the large external magnetic field necessary to obtain saturatio magnetostriction has due to large magnetocrystalline anisotropy energy restrained the applicationof magnetostriction materials in RFe$_2$intermetallic compounds. As a result of its solution, the largest published value of effective giant magnetostriction in a low external magnetic field (less than a few hundred Oe) is reported in this paper by means of amorphisation of RFe$_2$intermetallic compounds with the addition of boron, as a half metal. For the amorphous (SmFe$_2$)0.97 B0.03 alloys, the effective magnetostriction of -545 and -610 $\times$ 10-6 is obtained at 400 and 1,000 Ie, respectively. Moreover, the effective magnetostriction of 590 and 630$\times$10-6 in the amorphous (TbFe$_2$)0.98 B0.02 alloys is also found at 400 and 1,000 Oe, respectively. This result will provide a clue to understanding the effect of half metal on anomalous increase of the effective giant magnetostriction and attract the great attention for magnetostriction applications.

  • PDF

The Influence of the Diffuser Divergence Angle on the Critical Pressure of a Critical Nozzle (디퓨저 확대각이 임계노즐의 임계압력비에 미치는 영향)

  • Kim Jae Hyung;Kim Heuy Dong;Park Kyung Am
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.131-134
    • /
    • 2002
  • Compressible gas flow through a convergent-divergent nozzle is choked at the nozzle throat under a certain critical pressure ratio, and then being no longer dependent on the pressure change in the downstream flow field. In practical, the flow field at the divergent part of the critical nozzle can affect the effective critical pressure ratio. In order to investigate details of flow field through a critical nozzle, the present study solves the axisymmetric, compressible, Wavier-Stokes equations. The diameter of the nozzle throat is D=8.26mm and the half angle of the diffuser is changed between $2^{\circ}\;and\;10^{\circ}$ Computational results are compared with the previous experimental ones. The results obtained show that the divergence angle is significantly influences the critical pressure ratio and the present computations predict the experimented discharge coefficient and critical pressure ratio with a good accuracy. It is also found that a nozzle with the half angle of $4^{\circ}$ nearly predicts the theoretical critical pressure ratio.

  • PDF

Behaviour of cold-formed steel hollow and concrete-filled members

  • Jane Helena, H.;Samuel Knight, G.M.
    • Steel and Composite Structures
    • /
    • v.5 no.1
    • /
    • pp.35-47
    • /
    • 2005
  • This paper presents the results of a series of tests carried out on hollow and concrete-filled coldformed steel sections subjected to axial and bending forces. The effects of eccentricity ratio and strength of in-fill on the behaviour of these sections were studied. A total of forty-eight medium sized columns and six beams were tested to failure. Extensive measurements of material properties, strains, axial shortening and lateral deflection were carried out. Interaction of local and overall buckling was observed in the tests. Failure mode observations were local buckling coupled with overall buckling. A description of the specially fabricated end fixtures for applying eccentric loading to the columns and to simulate pinned end condition is also presented. The experimental results of hollow columns are compared with the existing Indian, British and American codes of practice and the results of concrete-filled columns are compared with EC4 recommendations. It is seen that in the case of hollow columns predictions based on British and American codes of practice and in the case of concrete-filled columns predictions based on EC4 recommendations agree reasonably well with the experimental results. From the experiments it is seen that the provision of in-fill substantially increases the ultimate load carrying capacity of the order of one and a half to two times and the increase in strength of the in-filled concrete from a low grade concrete of compressive strength 24.94 MPa to a high grade concrete of compressive strength 33.26 MPa increases the ultimate load carrying capacity by one and a half times irrespective of the eccentricity of loading.

Parallel Load Techinques Application for Transcranial Magnetic Stimulation

  • Choi, Sun-Seob;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • v.17 no.1
    • /
    • pp.27-32
    • /
    • 2012
  • Transcranial magnetic stimulation requires an electric field composed of dozens of V/m to achieve stimulation. The stimulation system is composed of a stimulation coil to form the electric field by charging and discharging a capacitor in order to save energy, thus requiring high-pressure kV. In particular, it is charged and discharged in capacitor to discharge through stimulation coil within a short period of time (hundreds of seconds) to generate current of numerous kA. A pulse-type magnetic field is formed, and eddy currents within the human body are triggered to achieve stimulation. Numerous pulse forms must be generated to initiate eddy currents for stimulating nerves. This study achieved high internal pressure, a high number of repetitions, and rapid switching of elements, and it implemented numerous control techniques via introduction of the half-bridge parallel load method. In addition it applied a quick, accurate, high-efficiency charge/discharge method for transcranial magnetic stimulation to substitute an inexpensive, readily available, commercial frequency condenser for a previously used, expensive, high-frequency condenser. Furthermore, the pulse repetition rate was altered to control energy density, and grafts compact, one-chip processor with simulation to stably control circuit motion and conduct research on motion and output characteristics.

Measurement of Radiative Heat Flux of Kick Motor at Ground Test (킥 모터 지상 시험의 플룸 복사 열유속 측정)

  • Kim, Seong-Lyong;Choi, Sang-Ho;Ko, Ju-Yong;Kim, In-Sun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.440-443
    • /
    • 2008
  • Plume radiation has been measured during ground tests of KSLV-I kick motor in order to predict the thermal load on the equipment around the kick motor at flight. The measuring positions are the kick motor base, and the measured heats were about 2${\sim}$5 w/cm$^2$. The measured heat showed a lot of shot fluctuation in their values, and the radiative heats at the latter half of time are higher than those of the first half. A plausible explanation for these phenomena was given as the variation of alumina particles with time. The radiative heats along the plume axis were also measured recently at 8 positions with 1.5m radius from plume axis, but only the initial parts of the results could be acceptable because the sensor were damaged by the accumulated heat. The strongest heat occurred at the middle of the plume, which can be explained with different view factors. Despite of the plausible explanation, it seems to need more analysis because the plume structure such as temperature, alumina particle, after burning has not been revealed until yet. The measure heat flux has been reflected in the prediction of the plume radiation at high altitude where the kick motor operates.

  • PDF

A Clinical Study on Liver Scanning using Colloidal Radiogold and Liver Function in Cirrhosis of the Liver (간경변증(肝硬變症)에 있어서 교질형방사성금(膠質形放射性金)($^{198}Au$)을 사용(使用)한 간(肝)스켄과 간기능(肝機能)과의 관계(關係)에 관(關)한 임상연구(臨床硏究))

  • Koh, Chang-Soon;Rhee, Chong-Heon;Chang, Ko-Chang;Lee, Young;Min, Young-Eal;Hong, Changgi D.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.3 no.1
    • /
    • pp.59-67
    • /
    • 1969
  • Correlation between the blood clearance half time and findings of liver scan using the colloidal radiogold in patients of liver cirrhosis is observed through the scoring system, in which the more changes in size, shape and density in the liver scan, the more points are given (table 1). Results: 1) Within the increase in severity of hepatocellular dysfunction in liver cirrhosis, the degree and frequency of following changes in liver scan (done with colloidal radiogold) were increased in order. a) generalized hepatomegaly b) enlargement of the left lobe & reduction of the right lobe c) relatively increased radiodensity in the left lobe and 4) visualization of spleen. 2) Frequency of the normal scan in liver cirrhosis was $12{\pm}3.56%$, frequency of normal value in blood clearance half time of the radiogold was $5.0{\pm}2.34%$ and frequency of normal scan & normal blood clearance rate in liver cirrhosis was $3.6{\pm}2.06%$.

  • PDF

An Analysis of Problem-solving Ability and Mathematical Justification of Mathematical Essay Problems of 5th Grade Students in Elementary School (수리논술형 문제에 대한 초등학교 5학년 학생들의 문제해결력과 수학적 정당화 과정 분석)

  • Kim, Young-Sook;Pang, Jeong-Suk
    • The Mathematical Education
    • /
    • v.48 no.2
    • /
    • pp.149-167
    • /
    • 2009
  • This study was aimed to examine problem-solving ability of fifth graders on two types of mathematical essay problems, and to analyze the process of mathematical justification in solving the essay problems. For this purpose, a total of 14 mathematical essay problems were developed, in which half of the items were single tasks and the other half were data-provided tasks. Sixteen students with higher academic achievements in mathematics and the Korean language were chosen, and were given to solve the mathematical essay problems individually. They then were asked to justify their solution methods in groups of 4 and to reach a consensus through negotiation among group members. Students were good at understanding the given single tasks but they often revealed lack of logical thinking and representation. They also tended to use everyday language rather than mathematical language in explaining their solution processes. Some students experienced difficulty in understanding the meaning of data in the essay problems. With regard to mathematical justification, students employed more internal justification by experience or mathematical logic than external justification by authority. Given this, this paper includes implications for teachers on how they need to teach mathematics in order to foster students' logical thinking and communication.

  • PDF

Gaussian Bracket Expressions of Aplanatic and Achromatic Conditions for Telephoto Type Telescope Objective Derived from the Numerical Solution (Aplanat조건과 Achromatwhrjs의 Gauss괄호 표현과 Telephoto형 망언경 대물렌즈의 설계)

  • 임천석
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.3
    • /
    • pp.243-251
    • /
    • 1993
  • We have derived Gaussian bracket expressions of aplanatic and achromatic conditions and obtained the numerical solutions for each of two modules of the telephoto type telescope objective free from the Seidel first order spherical aberration, coma, and longitudinal chromatic aberration. The system which is for use in sighting a target is optimized within the resolution of eyes. The objective lens satisfying the aplanatic and achromatic condition has f/8.5 with the half field angle 0.$3^{\circ}$, and the telephoto ratio is 0.839 with the focal length of 30 cm.

  • PDF

MBE-growth and Oxygen Pressure Dependent Electrical and Magnetic Properties of Fe3O4 Thin Films

  • Dung, Dang Duc;Feng, Wuwei;Sin, Yu-Ri-Mi;Thiet, Duong Van;Jo, Seong-Rae
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.60-60
    • /
    • 2011
  • Giant magnetoresistance (GMR), tunneling magnetoresistance (TMR), and magnetic random-access memory (MRAM) are currently active research areas in spintronics. The high magnetoresistance and the high spin polarization (P) of electrons in the ferromagnetic electrodes of tunnel junction or intermediate layers are required. Magnetite, Fe3O4, is predicted to possess as half-metallic nature, P ~ 100% spin polarization, and has a high Curie temperature (TC~850 K). Experiments demonstrated that the P~($80{\pm}5$)%, ~($60{\pm}5$)%, and ~40-55% for epitaxial (111), (110) and (001)-oriented Fe3O4 thin films, respectively. Epitaxial Fe3O4 films may enable us to investigate the effects of half metals on the spin transport without grain-boundary scattering.In addition, it has been reported that the Verwey transition (TV, a first order metal-insulator transition) of 120 K in bulk Fe3O4 is strongly affected by many parameters such as stoichiometry and stress, etc. Here we report that the growth modes, magnetism and transport properties of Fe3O4 thin films were strongly dependent on the oxygen pressure during film growth. The average roughness decreases from 1.021 to 0.263 nm for the oxygen pressure increase from $2.3{\times}10-7$ to $8.2{\times}10^{-6}$ Torr, respectively. The 120 K Verwey transition in Fe3O4 was disappeared for the sample grown under high oxygen pressure.

  • PDF