• 제목/요약/키워드: half-dose

Search Result 538, Processing Time 0.033 seconds

Extrafetal Transfer of $Li^{+}$ in Amniotic Fluid of Pregnant Rabbits (토끼에서 태자를 통하지 않은 양수내 $Li^{+}$의 이동)

  • Kim, Young-Jae;Ho, Won-Kyung;Sung, Ho-Kyung
    • The Korean Journal of Physiology
    • /
    • v.24 no.1
    • /
    • pp.27-37
    • /
    • 1990
  • The extrafetal transfer of $Li^{+}$ in amniotic fluid was studied in 45 pregnant rabbits. LiCl solution was administered either intravenously to mother or directly into the amniotic sac and monitored the appearance and disappearance of $Li^{+}$ in the amniotic fluid, then calculated the transfer rate of $Li^{+}$ of extrafetal origin. To study the transplacental $Li^{+}$ transfer, a solution of 150 mM LiCl was infused continuously via maternal vein (initial dose: 0.7 mmol/kg, maintaining dose: 0.03 mmol/kg/min) and the $Li^{+}$ concentration was measured in maternal blood and amniotic fluid after 60 and 120 minutes of infusion. Change in the volume of aminotic fluid was determined by Congo red dilution method at the same time. Effects of duration of gestation was not considered in this study. Extrafetal transport of $Li^{+}$ into the amniotic fluid was estimated by comparing the $Li^{+}$ concentration and volume of amniotic fluid determined before and after ligating the placental vessels. Extrafetal $Li^{+}$ transport from the amniotic fluid was determined by observing the time dependent disappearance of $Li^{+}$ and Congo red in amniotic fluid after injecting 0.5 ml solution of 15 mM or 90 mM LiCl and 50 mg/ml Congo red. Following are the results obtained: 1) During infusion of LiCl through maternal vein the ratio of the aminotic $Li^{+}$/maternal plasma $Li^{+}$ increased significantly along with the increment of fetal weight. 2) The volume of amniotic fluid of larger fetuses than 20.5 gm increased significantly during administration of LiCl while that of smaller fetuses did not change. 3) After umbilical cord ligation the $Li^{+}$ concentration of amniotic fluid of larger fetuses than 20.5 gm was decreased to $59.9{\pm}10.3%$ and $56.9{\pm}42.9%$ $(mean{\pm}S.D.)$ of those of control group after 60 and 120 minutes of LiCl infusion respectively. In amniotic fluid of smaller fetuses than 20.5 gm, there was no significant difference between control and ligation groups. 4) The disappearance rate of Congo red in the amniotic fluid was $45.2{\pm}8.2%/hr$. 5) The disappearance rate of $Li^{+}$ after intraamniotic injection of LiCl depended on the amount injected. On injecting $7.5\;{\mu}mol$ LiCl, $Li^{+}$ disappeared rapidly from the amniotic fluid and the rates after 60 min and 90 min were $97.0{\pm}2.8,\;98.5{\pm}2.0%$ respectively. On injecting $45\;{\mu}mol$ LiCl, the rates were $56.0{\pm}15.4,\;78.9{\pm}14.5%$ at 60 and 90 min. 6) From the above results it was concluded: a) $Li^{+}$ transfer into the amniotic fluid increased along with the fetal growth and one half of $Li^{+}$ influx is through the extrafetal route even after the maturation of fetal kidney. b) One half of the $Li^{+}$ transfer from the amniotic fluid was through swallowing of fetus, while the remaining half was transfered rapidly through amniotic membrane, which was concentration limited.

  • PDF

Analyze for the Quality Control of General X-ray Systems in Capital region (수도권지역 일반촬영 장비의 정도관리 분석)

  • Kang, Byung-Sam;Lee, Kang-Min;Shim, Woo-Yong;Park, Soon-Chul;Choi, Hak-Dong;Cho, Yong-Kwon
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.93-102
    • /
    • 2012
  • Thanks to the rapid increase of the interest in the quality control of the General X-ray systems, this research proposes the direction of the quality control through comparing and inspecting the actual condition of the respective quality control in the Clinic, the educational institution and the hospital. The subjects of the investigation are diagnostic radiation equipment's in the clinic, the educational institution and the hospital around the capital. A test of kVp, mR/mAs out put test and reproducibility of the exposure dose, half value layer, an accordance between the light field and the beam alignment test, and lastly reproducibility of the exposure time. Then the mean difference of the percentage, the CV (Coefficient of Variation, CV) and the attenuated curve which are respectively resulted from the above tests are computed. After that we have evaluated the values according to the regulations on the Diagnostic Radiation Equipment Safety Administration regulations. In the case of the clinic and the educational institution, there were 22 general X-ray devices. And 18.2% of the kVp test, 13.6% of the reproducibility of exposure dose test, 9.1% of the mR/mAs out put test, and 13.6% of the HVL (Half Value Layer) test appeared to be improper. In the case of the hospital, however, there were 28 devices. And 7.1% of the reproducibility of exposure dose, 7.1% of the difference in the light field/ beam alignment, and 7.1% of the reproducibility of the exposure time appeared to be improper. According to the investigation, the hospital's quality control condition is better than the condition in the clinic and the educational institution. The quality control condition of the general X-ray devices in the clinic is unsatisfactory compared to the hospital. Thus, it is considered that realizing the importance of the quality control is necessary.

Dosimetric Characteristics of Edge $Detector^{TM}$ in Small Beam Dosimetry (소조사면 선량 계측을 위한 엣지검출기의 특성 분석)

  • Chang, Kyung-Hwan;Lee, Bo-Ram;Kim, You-Hyun;Choi, Kyoung-Sik;Lee, Jung-Seok;Park, Byung-Moon;Bae, Yong-Ki;Hong, Se-Mie;Lee, Jeong-Woo
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.191-198
    • /
    • 2009
  • In this study, we evaluated an edge detector for small-beam dosimetry. We measured the dose linearity, dose rate dependence, output factor, beam profiles, and percentage depth dose using an edge detector (Model 1118 Edge) for 6-MV photon beams at different field sizes and depths. The obtained values were compared with those obtained using a standard volume ionization chamber (CC13) and photon diode detector (PFD). The dose linearity results for the three detectors showed good agreement within 1%. The edge detector had the best linearity of ${\pm}0.08%$. The edge detector and PFD showed little dose rate dependency throughout the range of 100~600 MU/min, while CC13 showed a significant discrepancy of approximately -5% at 100 MU/min. The output factors of the three detectors showed good agreement within 1% for the tested field sizes. However, the output factor of CC13 compared to the other two detectors had a maximum difference of 21% for small field sizes (${\sim}4{\times}4\;cm^2$). When analyzing the 20~80% penumbra, the penumbra measured using CC13 was approximately two times wider than that using the edge detector for all field sizes. The width measured using PFD was approximately 30% wider for all field sizes. Compared to the edge detector, the 10~90% penumbras measured using the CC13 and PFD were approximately 55% and 19% wider, respectively. The full width at half maximum (FWHM) of the edge detector was close to the real field size, while the other two detectors measured values that were 8~10% greater for all field sizes. Percentage depth doses measured by the three detectors corresponded to each other for small beams. Based on the results, we consider the edge detector as an appropriate small-beam detector, while CC13 and PFD can lead to some errors when used for small beam fields under $4{\times}4\;cm^2$.

  • PDF

Evaluation of Image Noise and Radiation Dose Analysis In Brain CT Using ASIR(Adaptive Statistical Iterative Reconstruction) (ASIR를 이용한 두부 CT의 영상 잡음 평가 및 피폭선량 분석)

  • Jang, Hyon-Chol;Kim, Kyeong-Keun;Cho, Jae-Hwan;Seo, Jeong-Min;Lee, Haeng-Ki
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.357-363
    • /
    • 2012
  • The purpose of this study on head computed tomography scan corporate reorganization adaptive iteration algorithm using the statistical noise, and quality assessment, reduction of dose was evaluated. Head CT examinations do not apply ASIR group [A group], ASIR 50 applies a group [B group] were divided into examinations. B group of each 46.9 %, 48.2 %, 43.2 %, and 47.9 % the measured in the phantom research result of measurement of CT noise average were reduced more than A group in the central part (A) and peripheral unit (B, C, D). CT number was measured with the quantitive analytical method in the display-image quality evaluation and about noise was analyze. There was A group and difference which the image noise notes statistically between B. And A group was high so that the image noise could note than B group (31.87 HUs, 31.78 HUs, 26.6 HUs, 30.42 HU P<0.05). The score of the observer 1 of A group evaluated 73.17 on 74.2 at the result 80 half tone dot of evaluating by the qualitative evaluation method of the image by the bean curd clinical image evaluation table. And the score of the observer 1 of B group evaluated 71.77 on 72.47. There was no difference (P>0.05) noted statistically. And the inappropriate image was shown to the diagnosis. As to the exposure dose, by examination by applying ASIR 50 % there was no decline in quality of the image, 47.6 % could reduce the radiation dose. In conclusion, if ASIR is applied to the clinical part, it is considered with the dose written much more that examination is possible. And when examination, it is considered that it becomes the positive factor when the examiner determines.

Gamma Irradiation Effects on Conchospores of Porphyra Species 2. The Effects of High Gamma Irradiation on Germination and Growth of Conchospores of Two Varieties (김의 각포자에 대한 r-선의 조사효과 2. 두 품종의 각포자의 발아생장에 미치는 고선량 r-선의 조사효과)

  • KIM Joong-Rae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.18 no.1
    • /
    • pp.52-56
    • /
    • 1985
  • For the fundamental studies of radiation breeding in edible marine algae, the biological effects on conchospores of Porphyra species by gamma-irradiation were examined. Two varieties, Keun-cham-gim (Porphyra tenera Kjell. form tamatsuensis Miura) and Saga No.5, were chosen for this study, and their conchospores after r-irradiation($5.0{\sim}20.0$ KR) were cultured for 50 days. The results obtained were summarized as follows. 1. Gamma-irradiation in less than the dose of 20KR did not affect germination of conchospores, and almost all spores grew into two cells germ in 24 hours after irradiation, but withering germs were gradually increased in number according to higher exposure within 5 days old culture. 2. High irradiation caused the induction of giant cells, abnormal useless growth of hold-fast, lumpish thalli and callus-like lumpy tissues. 3. The liberation of neutral spores from young germs and carpospores from mature thalli were observed on the frond exposed at $10{\sim}20$ KR irradiation. All spores were normal in division and its size. 4. The best irradiation effect on growth of Keun-cham-gim was observed at 10 KR dose, whose growth-rates were $140\%$ in wet weight and $108\%$ in mean frond area, but only $48\%$ was recorded in wet weight at 20 KR exposure. Saga No.5 were in contrast with Keun-cham-gim, and their most growth-rate was $400\%$ in wet weight ($258\%$ in frond area) at 10 KR irradiation and the worst was $20\%$ at the dose of 20 KR. 5. The withering phenomenon to death by treatment of gamma-ray presented substantial difference between two varieties. Survival rate compared with control in Keun-cham-gim was $70.7\%$ at 20 KR, but that in Saga No.5 recorded $47.0\%$ at same dose. 6. Synthesizing the results of high and low r-irradiation, it was suggested tat high r-irradiation in more than 5.0 KR inhibited conspicuously the growth of germs derived from conchospores, and about half of them withered at 15.0 KR dose or more.

  • PDF

Performance Measurement of Diagnostic X Ray System (진단용 X선 발생장치의 성능 측정)

  • You, Ingyu;Lim, Cheonghwan;Lee, Sangho;Lee, Mankoo
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.447-454
    • /
    • 2012
  • To examine the performance of a diagnostic X-ray system, we tested a linearity, reproducibility, and Half Value Layer(HVL). The linearity was examined 4 times of irradiation with a given condition, and we recorded a level of radiation. We then calculated the mR/mAs. And the measured value should not be more than 0.1. If the measured value was more than 0.1, we could know that the linearity was decreased. The reproducibility was analyzed 10 times of irradiations at 80kVp, 200mA, 20mAs and 120kVp, 300mA, 8mAs. The values from these analyses were integrated into CV equation, and we could get outputs. The reproducibility was good if the output was lower than 0.05. HVL was measured 3 times of irradiation without a filter, and we inserted additional HLV filters with 0, 1, 2, 4 mm of thickness. We tested the values until we get the measured value less than a half of the value measured without additional filter. We tested the linearity, the reproducibility, and HVL of 5 diagnostic X-ray generators in this facilities. The linearity of No. 1 and No. 5 generator didn't satisfy the standard for radiation safety around 300mA~400mA and 100mA~200mA, respectively. HVL of No.1 generator was not satisfied at 80kVp. The outputs were higher in the three-phase equipment than the single-phase equipment. The old generators need to maintain and exchange of components based on the these results. Then, we could contribute to getting more exact diagnosis increasing a quality of the image and decreasing an expose dose of radiation.

Determination of Novel Synthetic 5HT2C Agonist KOPC20010 by Gas-Chromatography/Mass Spectrometry and its Bioavailability in Sprague-Dawley Rats

  • Im, Hye-Yeon;Pae, Ae-Nim;Yang, Ha-Yun;Park, Woo-Kyu;Seo, Ji-Eun;Haque, Md. Mamunul;Kwon, Oh-Seung
    • Journal of Pharmaceutical Investigation
    • /
    • v.41 no.1
    • /
    • pp.31-36
    • /
    • 2011
  • $5HT_{2C}$ receptor among fourteen 5-HT subtypes plays important roles in several disorders such as depression, anxiety, epilepsy, schizophrenia and sleep disorders. The purpose of the study is to investigate pharmacokinetic parameters and bioavailability of a newly synthesized selective agonist of $5-HT_{2C}$ receptor, KOPC-20010 (KP10) in rats after intravenous and oral administration for the development of therapeutic anti-obesity agents. KP10 was administered orally (40 mg/kg) or intravenously (20 mg/kg), blood was collected via a catheter, and analyzed by GC/MSD. The calibration curve of KP10 in plasma and urine showed high linearity ($r^2$ >0.999). The retention times of KP10 in plasma and urine were 8.7 and 9.7 min, respectively. After oral administration of 40 mg/kg, pharmacokinetic parameters were calculated as follows; $C_{max}$ value was $1242.9{\pm}1195.5$ ng/mL at $1.1{\pm}0.6$ hr ($T_{max}$). $AUC_{0->24hr}$ and $AUC_{0>{\infty}}$ were $8034.2{\pm}960.7$ and $10464.1{\pm}681.5\;ng{\cdot}hr/mL$, respectively. The terminal half-life was $21.9{\pm}7.6$ hr. $AUC_{0->24hr}$ and $AUC_{0>{\infty}}$ were $4292.4{\pm}523.0$ and $6111.2{\pm}756.2\;ng{\cdot}hr/mL$, respectively, after 20 mg/kg of intravenous administration. The terminal half-life after intravenous administration was $25.1{\pm}9.4$ hr. Bioavailability of KP10 was determined to 86%. The excretion amount into the urine within 48 hr was approximately 4.7 to 6.7% of the dose administered. These data may be beneficial to the anti-obesity drug development of KP10.

Studies on the effect of split application of potash on paddy -Effect of split application of two different rates at various growth stages- (수도(水稻)에 대(對)한 가리분시(加里分施)에 관(關)한 연구(硏究) - 생육기(生育期) 및 시용량별(施用量別) 분시효과(分施効果) -)

  • Oh, Wang Keun;Lee, Sang Bum;Park, Chan Ho;Kim, Sung Bae
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.7 no.2
    • /
    • pp.107-112
    • /
    • 1974
  • In order to establish a rational application method of potash to paddy rice(Oryza sativa L. Jinheung, a Japonica variety) field and pot experiments on split application of two rates (6kg and 12kg $K_2O$ per 10a) of potash at a certain critical growing stage have conducted in 1973 and the results were as follows: 1. At the treatment where a rate of 6kg $K_2O$ per 10a(lower dose) of potash was supplied in two split doses, a half at transplanting time and the other half at young panicle formation stage, the yield of paddy rice appeatred to be low due to less number of panicles per hill. (Field experiment) 2. The treatment where potash supply ceased at transplanting time or at effective tillering stage but supplied at the other two stages (including panicle initiation stage) have failed to increase K content in the flag leaf and have shown low maturity and low thousand grain weight, which resulted in low paddy rice yield. (pot experiment) 3. From above two facts, it is concluded that the application of potash at transplanting time is an important practice for the high yielding of paddy rice. 4. The application of lime seemed to stimulate later growth of paddy depressing the unnecessary increase of poor miserable tillers in early stages of growth.

  • PDF

Toxicokinetics of paraquat in Korean patients with acute poisoning

  • Kim, Hak-Jae;Kim, Hyung-Ki;Lee, Hwayoung;Bae, Jun-Seok;Kown, Jun-Tack;Gil, Hyo-Wook;Hong, Sae-Yong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.20 no.1
    • /
    • pp.35-39
    • /
    • 2016
  • To conduct a kinetic study of paraquat (PQ), we investigated 9 patients with acute PQ intoxication. All of them ingested more than 20 ml of undiluted PQ herbicide to commit suicide and arrived at our hospital early, not later than 7 h after PQ ingestion. The urine dithionite test for PQ in all of the nine patients was strongly positive at emergency room. Blood samples were obtained every 30 min for the first 2~3 h and then every 1 or 2 h, as long as the clinical progression was stable among the patients for 30 h after PQ ingestion. The area under the plasma concentration-time curve ($AUC_{inf}$), which was extrapolated to infinity, was calculated using the trapezoidal rule. Toxicokinetic parameters, such as the terminal elimination half-life, apparent oral clearance, and apparent volume of distribution ($V_d/F$) were calculated. The maximum PQ concentration ($C_{max}$) and the time to reach maximum PQ concentration ($T_{max}$) were also obtained. Plasma PQ concentrations in nine patients were well described by a bi-exponential curve with a mean terminal elimination half-life of $13.1{\pm}6.8h$. $C_{max}$ and $AUC_{inf}$ were $20.8{\pm}25.7mg/l$ and $172.5{\pm}160.3h{\cdot}mg/l$, respectively. Apparent volume of distribution and apparent oral clearance were $50.9{\pm}61.3l/kg$ and $173.4{\pm}111.2l/h$, respectively. There were a significant correlation (r=0.84; p<0.05) between the PQ amount ingested and $C_{max}$. $AUC_{inf}$ also showed a significant correlation (r=0.83; p<0.05) with the PQ amount ingested. These correlations provide evidence that PQ has dose-linear toxicokinetic characteristics.

Biological Control of Plant Growth Using the Plant Growth-Promoting Rhizobacterium Bacillus mojavensis KJS-3 (Bacillus mojavensis KJS-3를 이용한 식물의 생육촉진 활성연구)

  • Pyo, Jae Sung;Shrestha, Sarmila Amatya;Park, Song Hee;Kang, Jae Seon
    • Journal of Life Science
    • /
    • v.24 no.12
    • /
    • pp.1308-1315
    • /
    • 2014
  • Biological control using the plant growth-promoting Rhizobacterium (PGPR) has received significant attention in recent years. PGPR has been linked with promoting growth in economically important crops, such as potatoes, tomatoes, and rice. Bacillus mojavensis KJS-3 (Moja-3), isolated from food waste, possesses antifungal properties against Aspergillus terreus, A. fumagatus, A. flavus, and Fusarium redolense, and it may have potential in the development of products for industrial applications. The main purpose of this study was to determine the effects of spraying the PGPR Bacillus mojavensis KJS-3 on the growth of altari radish (leaf number, leaf length, leaf weight, root length, and rhizome length, adjacent portion diameter, and weight) and lettuce (leaf number, length, width, and weight). Three different concentrations of the foliar spray treatment of B. mojavensis KJS-3 were applied to the altari radish and lettuce: the recommended standard concentration of $1{\times}10^9cfu/g$, half the standard concentration of $0.5{\times}10^9cfu/g$, and double the standard concentration of $2{\times}10^9cfu/g$). The B. mojavensis strain foliar spray treatment increased the growth of the leaves and roots of the altari radish and increased the growth of the lettuce leaves. For both plants, the recommended concentration of B. mojavensis KJS-3 produced better growth than half the standard concentration, and the growth was similar with the double dose. This study demonstrates positive effects of Moja-3, suggesting it may be a potential new bio-fertilizer for improving the growth of altari radish and lettuce.