• 제목/요약/키워드: half line

검색결과 655건 처리시간 0.022초

서울지역 지하철역의 공기 중 오염인자의 노선별 분포 특성 (Distribution Characteristics between Line and Line for Indoor Air Pollutant Factors at Subway Stations in Seoul Area)

  • 김민영;라승훈;신도철;한규문;최금숙;정일현
    • 한국환경보건학회지
    • /
    • 제24권2호
    • /
    • pp.134-144
    • /
    • 1998
  • A comprehensive air quality monitoring was carried out to investigate the criteria concentration of air pollutant in indoor of subway stations of Seoul City. The samples were collected twice per year (the first and the second half of the year) at each sampling point from February to September in 1997. Sampling point of subway stations was ticket office and platform. The measurement of indoor air pollutants such as sulfur dioxide(SO$_2$), nitrogen dioxide(NO$_2$), carbon monoxide(CO), carbon dioxide(CO$_2$), total suspended particulate(TSP) was performed to determine the indoor air quality. Heavy metals(Pb, Cd, Cu, Cr, As, Hg) were also measured together with those air pollutants. The annual average concentration of CO$_2$ and TSP in subway stations were relatively high while those of heavy metals were within 10% of environmental recommended standard concentration in all stations. As results of regression analysis between line and line of air factors, the concentrations of CO, CO$_2$, TSP, Pb, Cd, Cr and Cu were highly correlated, but those of $SO_2, NO_2$ and Hg were not correlated. As results of regression analysis between ticket office and platform, the concentrations of heavy metals such as Cr and Cu were highly correlated. Results of oneway analysis of variance between the first and the second half of the year air factors also indicated that CO, CO$_2$, Cd, Cu, Hg were significant($\alpha$=0.01), respectively. The average contration of total suspended particulate(TSP) in subway line No. 1 was shown high concentration(200 $\mu g/m^3\cdot$ day) level.

  • PDF

인터넷 영양정보의 내용 분석 (Analysis of Contents of Nutrition Information on the Internet)

  • 이선영;강혜경;양일선;강명희
    • 대한영양사협회학술지
    • /
    • 제10권2호
    • /
    • pp.224-234
    • /
    • 2004
  • 232 internet sites in Yahoo and Empas were monitored to analyze what good contents of nutrition information on line have for the internet searchers. As the sites on line were disappeared frequently, all the monitored sites were selected on April 25, 2003. 3 disciplined personnels analyzed the contents of the selected sites by using self-developed monitoring format. The results are as follows. Most of sites were administered by the marketing companies and only 8% by public institutions, associations and school. Especially, most of the contents of the sites by marketing companies were advertisement about their goods instead of nutrition information. Only 42.6% of sites indicated the sources of nutrition information. Only 10.3% of site administrators responded about on-line questions quickly within 1 day. Moreover, 46% of sites were not conformed their answering periods. On the other hand, 94.8% of sites offered more than 1 feedback methods. Monitors checked purposes offering on-line informations plurally. Leading purpose was for advertising and marketing their goods(59.5%) and 47% of them were opened for offering food and nutrition information. They offered various informations at the same time. More than half of the sites had the menus for food and nutrition information and connected sites, but the other half of them only advertised their own goods. Positive sides from monitored informations were as follows : 'communicating informations easily' (8.7%) / 'definite informations for daily living' (7.2%) / 'beneficial informations for nutritional management' (4.6%) / 'new informations' (2.1%). Negative sides of offered information were ‘not enough to give scientific basis and/or to simplify special evidences too much’(60.8%) / ‘to exaggerate the contents’ (41.4%) / ‘not to indicate the notice of side effect and/or to advertise that there are not side effect from using their goods’ (34.1%).

  • PDF

Elucidation of Central Line Refocusing in Quadrupolar Echo Formation

  • Han, Duk-Young
    • 한국자기공명학회논문지
    • /
    • 제3권1호
    • /
    • pp.27-35
    • /
    • 1999
  • Quadrupolar interaction is a strong line broadening agent for nuclei of half-integer spin except the central line. The two-pulse quadrupolar echo technique is widely used, which refocuses the quadrupolar broadening. Echo formation is due to the cancellation of quadrupolar broadening effect by the applied two pulses. Since the central line is not quadrupolar broadened, it should not be involved in the echo formation. However, the central line peak always appears in experiments. This is explained qualitatively here by close examination on the time development of individual coherence. This explanation is used to predict the number of echoes that will be formed with 2 pulse sequence for nuclei of I=3/2, 5/2, 7/2, 9/2 with ease.

  • PDF

초전도 한류기를 포함한 계통의 단락사고에 대한 EMTDC 해석 (Am EMTDC Analysis for Line Faults with a Superconducting Fault Current Limiter)

  • 최효상;황시돌;현옥배;정상진
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 1999년도 제1회 학술대회논문집(KIASC 1st conference 99)
    • /
    • pp.101-105
    • /
    • 1999
  • We have performed an EMTDC simulation for the current limiting effects of a superconducting fault current limiter (SFCL). The fault currents in the 154 kV transmission line between the Gaepo and Sungnam substations increased up to 54kA and 60kA during the line-to-line and three phase faults, respectively. The SFCL with 100 $\Omega$ of impedance after quench limited the currents to less than 17 kA within a half cycle. This limited current is well below the upper limit of a circuit breaker, suggesting that the impedance of the SFCL in the transmission line is sufficient.

  • PDF

Analysis of Tubular Structures in Medical Imaging

  • Kim, Jin-Woo
    • Journal of information and communication convergence engineering
    • /
    • 제7권4호
    • /
    • pp.545-550
    • /
    • 2009
  • A method fully utilizing multiscale line filter responses is presented to estimate the point spread function(PSF) of a CT scanner and diameters of small tubular structures based on the PSF. The estimation problem is formulated as a least square fitting of a sequence of multiscale responses obtained at each medical axis point to the precomputed multiscale response curve for the ideal line model. The method was validated through phantom experiments and demonstrated through phantom experiments and demonstrated to accurately measure small-diameter structures which are significantly overestimated by conventional methods based on the full width half maximum(FWHM) and zero-crossing edge detection.

Electronic Ballast Using a Symmetrical Half-bridge Inverter Operating at Unity-Power-factor and High Efficiency

  • Suryawanshi Hiralal M.;Borghate Vijay B.;Ramteke Manojkumar R.;Thakre Krishna L.
    • Journal of Power Electronics
    • /
    • 제6권4호
    • /
    • pp.330-339
    • /
    • 2006
  • This paper deals with novel electronic ballast based on single-stage power processing topology using a symmetrical half-bridge inverter and current injection circuit. The half-bridge inverter drives the output parallel resonant circuit and injects current through the power factor correction (PFC) circuit. Because of high frequency current injection and high frequency modulated voltage, the proposed circuit maintains the unity power factor (UPF) with low THD even under wide variation in ac input voltage. This circuit needs minimum and lower sized components to achieve the UPF and high efficiency. This leads to an increase in reliability of ballast at low cost. Furthermore, to reduce cost, the electronic ballast is designed for two series-connected fluorescent lamps (FL). The analysis and experimental results are presented for ($2{\times}36$ Watt) fluorescent lamps operating at 50 kHz switching frequency and input line voltage (230 V, 50 Hz).

A Design for a CPW-Fed Monopole Antenna with Two Modified Half Circular Rings for WLAN/WiMAX Operations

  • Kim, Woo-Su;Yoon, Joong-Han
    • Journal of information and communication convergence engineering
    • /
    • 제13권3호
    • /
    • pp.159-166
    • /
    • 2015
  • In this paper, a novel design for a triple-band coplanar waveguide (CPW)-fed monopole antenna for WLAN/WiMAX operations is proposed. The proposed antenna is printed on an FR4 substrate with an area of 22.0 mm × 30.0 mm, a thickness of 1.0 mm, and a relative permittivity of 4.4. The effects of various parameters of the proposed for triple band operation is investigated. Two half circular rings and a microstrip feed line are fabricated on the substrate to achieve triple band operation and good impedance matching. Prototypes of the proposed antenna have been fabricated and tested. Experiment results reveal that the measured return loss exhibits an acceptable agreement with the simulated return loss and satisfies the impedance bandwidth requirement of -10 dB, while simultaneously covering the WLAN and WiMAX bands. In addition, the proposed antenna shows good radiation characteristics and gains in the three operating bands.

A Broadband Half-Mode Substrate Integrated Waveguide Quadrature Wilkinson Power Divider Using Composite Right/Left-Handed Transmission Line

  • Eom, Dong-Sik;Lee, Hai-Young
    • Journal of electromagnetic engineering and science
    • /
    • 제17권1호
    • /
    • pp.9-13
    • /
    • 2017
  • In this work, a broadband composite right/left-handed (CRLH) half-mode substrate integrated waveguide (HMSIW) quadrature Wilkinson power divider is proposed. The proposed CRLH-HMSIW quadrature power divider includes a microstrip Wilkinson power divider on the transition structure between the microstrip and HMSIW, and two thru transmission lines for the HMSIW and the CRLH-HMSIW. The measured amplitude, phase difference and isolation between the two output ports of the proposed structure have 1 dB, ${\pm}5^{\circ}$ and less than -15 dB in a wide frequency range of 4.1-6.68 GHz with 47.9% bandwidth, respectively.

한국전력 노후 가공송전선의 동적송전용량에 대한 재평가 (A Reassessment for Dynamic Line Rating of Aged Overhead Transmission Lines in Kepco's Network)

  • 김성덕
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.123-129
    • /
    • 2010
  • During the past 2 decades, many electric power companies have been searching various solutions in order to supply power with economical and more efficiency in the present transmission utilities. Most interesting method to increase the line capacity of overhead transmission lines without constructing any new line might be to adapt Dynamic Line Rating(DLR). Specified rating is normally determined by any current level, not by conductor temperature. Although specified rating is essential to design transmission line, dip may be the most important factor in limiting transmission capacity. Transmission lines built by the oldest dip criterion among the 3 different design criteria for conductor dip are nearly over one-half of all Kepco's transmission lines. This paper describes an up-rating method for those transmission lines in order to apply DLR technique. Based on limit dip conductor temperature and current of the transmission lines, limitation performance and effectiveness in applying DLR with weather model are analyzed. As a result of analysis, it can be shown that an improved method could be effectively used for increasing the line rating of old transmission line which was built by the design criterion with low dip margin.

입체 재단법에 의한 Tight Fitting시 등폭 기준선의 설정에 관한여 (On the Fixing of the Shoulder Blade Level during Tight Fitting by the Draping Design)

  • 이순섭
    • 복식문화연구
    • /
    • 제4권3호
    • /
    • pp.373-381
    • /
    • 1996
  • Draping design system organized by European about 13C has been developed greatly for a long while, but for the purpose of the practical use the Dress form similar to human body has been needed. In order to make three-dimensional effect as fitting Muslin ot the Dress form. the Basic lien has to be established in Muslin and Dress form each. At this time, Shoulder-blade level is indicated from various angles : measure down 10cm from the back neck point, a quarter of the back neck point to the waist lie, the half-way point between neckline and bust line, measure down 41 inches from the back neck line, measure down 3 inches from the top edge of the muslin at center back and cross mark for neck line, and so forth. This study established the Basic line through the two ways of them (B.N.P∼B.L/2, B.N.P∼W.L/4), did tight fitting to the 5 kinds of Dress forms which ar normal type in the drop value(the difference between hip circumference and bust circumference), and acquired Basic Pattern. After the experiment, fitness are throughly investigate by statistical analysis of measurements. As a result, this study finds out that fit is proper when shoulder blade level is situated on a fourth of the back neck point to the waist line and a quarter point between back neck point and waist line, and waist dart is situated on the back center line and princess line.

  • PDF