• Title/Summary/Keyword: half beam

Search Result 394, Processing Time 0.029 seconds

Comparison on Flexural Behaviors of Architectural Precast Prestressed Rectangular and Inverted-tee Concrete Beams (건축용 프리캐스트 프리스트레스트 역티형 보와 직사각형 보의 휨거동 비교)

  • 유승룡
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.6
    • /
    • pp.75-82
    • /
    • 2000
  • Flexural behaviors of two typical architectural precast beam sections ; inverted tee and rectangular - were compared and investigated. The heights of web in inverted tee beams are generally less than half of beam depth in building structures to accomodate the nib of double-tee where the total building height limited considerably. The inverted-tee beams are designed for parking live load - 500kgf/$\m^2$ and market - 1,200kgf/$\m^2$ according to the currently used typical shape in the domestic market building site in Korea. The bottom dimension and area of rectangular beams are same to those of inverted tee beams to compare the flexural behaviors of two beams. These two beams are also reinforced for similar strength. Four flexural tests are performed on two beams. Following results are obtained from the tests; 1) The rectangular beam is simpler in production, transportation, and election, and more economic than the inverted tee beam for these two beams with same dimension and similar strength. 1) The estimations of flexural strength of two beams by Strength Design Method and Strain Compatibility Method is fully complied with the result of tests. However, Strain Compatibility Method is slightly ore accurate than Strength Design Method. 2) Overall deflections of two type beam under the service loads are less than those of the allowable limit in ACI Code provision. 3) The rectangular beam is failed in large deflection (average 12.56mm large) than those of inverted tee beams. 4) The rectangular and inverted tee beams with 6m span develop initial flexural crackings under the 88% of full service loading even though they designed to satisfy the ACI tensile stress limit provisions.

DOSIMETRY OF ASYMMETRIC COLLIMATIORS (비대칭 콜리메이터의 선량분포 측정)

  • Jeon, Byeong-Chul;Bang, Dong-Wan;Jung, Kap-Soo;Shin, Dong-Bong;Park, Jae-Il
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.8 no.1
    • /
    • pp.109-114
    • /
    • 1996
  • PURPOSE : To investigate the effect of asymmetric jaws for delivering a uniform accurate dose of radiation to the junctions. METHODS & MATERIALS : A linear accelerator with a set of asymmetric jaws(varian 600C, 2100C, 2100CD with 4mev, 10mev, 10mev). Dose disribution was measured at the junctions with films in phantom. Total $10{\times}20cm^2$ with each $10{\times}10cm^2$ in deviation of ${\pm}1mm$ jaws. RESULTS : Film dosimetry showed the accuracy of asymmetric jaws depending on the machine. CONCLUSION : Understanding the mechanical characteristics of the use of half-beam at the junctions, without hot or cold regions.

  • PDF

Behavior of Wide Beam-Column Interior Joint with Slab (횡력을 받는 넓은 보-기둥 내부 접합부의 거동 평가)

  • Lee, Bum-Sik;Park, Seong-Sik;Park, Ji-Young
    • Land and Housing Review
    • /
    • v.3 no.4
    • /
    • pp.433-449
    • /
    • 2012
  • An experimental investigation was conducted to study the behavior of RC wide beam-column joints with slab subjected to reversed cyclic loads under constant axial load. Six half scale interior wide beam-column assemblies representing a portion of a frame subjected to simulated seismic loading were tested, including three specimens without slab and three specimens with slab. The primary variables were the ratio of column-to-beam flexural capacity ($M_r={\Sigma}M_c/{\Sigma}M_b$ ; 0.77~2.26), ratio of the column-to-beam width (b/H ; 1.54, 1.67). Test results are shown that (1) the current design code and practice for interior joints(type 2) are apply to the wide beam-high strength concrete column. (2) the presence of a slab have an effect on the performance of the wide beam-high strength concrete column interior joints(type 2). therefore in the design of the wide beam-high strength concrete column interior joints(type 2), the width of slab effective as a T beam flange should be considered. It was show that the case of the ratio of column-to-beam flexural capacity is more than 2.0, the effective width of slab are 2 times of an effective depth of wide beam, however if the ratio of column-to-beam flexural capacity is 1.4~2.0, the effective width of slab are not able to be considered.

Dry thermal development of negative electron beam resist polystyrene

  • Con, Celal;Abbas, Arwa Saud;Yavuz, Mustafa;Cui, Bo
    • Advances in nano research
    • /
    • v.1 no.2
    • /
    • pp.105-109
    • /
    • 2013
  • We report dry thermal development of negative resist polystyrene with low molecular weight. When developed on a hotplate at $350^{\circ}C$ for 30 min, polystyrene showed reasonable high contrast and resolution (30 nm half-pitch), but low sensitivity. Resist sensitivity was greatly improved at lower development temperatures, though at the cost of reduced contrast. In addition, we observed the thickness reduction due to thermal development was higher for larger remaining film thickness, implying the thermal development process is not just a surface process and the more volatile chains below the top surface may diffuse to the surface and get evaporated.

Cyclic Behavior of Reinforced Concrete Coupling Beams with Bundled Diagonal Reinforcement (묶음 대각철근을 적용한 철근콘크리트 연결보의 이력거동 평가)

  • Han, Sang Whan;Kwon, Hyun Wook;Shin, Myung Su;Lee, Ki Hak
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.3
    • /
    • pp.117-124
    • /
    • 2014
  • Diagonal reinforced coupling beam of coupled shear walls can provide sufficient strength and stiffness to resist lateral force. However, the reinforcement details for coupling beams required by ACI 318 (2011) are difficult to construct because of the reinforcement congestion and confined interior area. This study presents experimental results about the seismic performance of coupling beams having bundled diagonal reinforcement to improve the workability. Experiments were conducted using half scaled precast coupling beams having an aspect ratio of 2.0. It was observed that the bundled diagonal reinforced coupling beams can develop seismic performance similar to the coupling beams with requirement details specified in ACI 318 (2011).

Design of slotted waveguide antenna with slot depth variation (슬롯깊이 변화에 따른 도파관 슬롯 안테나의 설계)

  • Kim, Gue-Chol
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.4
    • /
    • pp.535-540
    • /
    • 2013
  • We design a slotted waveguide antenna for X-band which a 1.4m length with slot depth variation. A 54 slot array is modeled and simulated by CST, and the side lobe level is suppressed effectively in a certain range of frequency. The experimental results of the antenna show that its gain, maximum sidelobe level and half power beam-width are 21.8dB, -31dB and 2.0deg, respectively.

Current-Controlled Wavelength-Tunable Fiber Comb Filter based on Polarization-Diversity Loop Configuration (전류 조절로 파장 튜닝 가능한 편광상이 배치구조 기반 광섬유 빗살 필터)

  • Choi, Dae-Ho;Lee, Yong-Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.33-37
    • /
    • 2010
  • In this paper, we have demonstrated absolute wavelength tuning in an optical fiber comb filter based on a polarization-diversity loop configuration by controlling the current injected into enameled wires wound on polarization-maintaining fibers (PMF's), that is, adjusting Joule heat generated from enameled wires. The proposed fiber comb filter consists of a polarization beam splitter, a half-wave plate, a quarter-wave plate, and PMF's. And we observed wavelength change of spectral dips in transmission spectra of the fabricated filter by varying an input current applied to enameled wires. The absolute wavelength of the filter could be controlled in proportional to the square of the input current with good linearity, and the rate of the wavelength shift with respect to the input current was measured as 36.79[nm/$A^2$].

Performance on the Beam-Switched Demand Assigned Multiple Access for the Packet Satellite Communication (패킷 위성통신의 빔스위칭 요구할당 다중 접속 방식에 대한 성능 연구)

  • 김덕년;김재명
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.10
    • /
    • pp.1462-1470
    • /
    • 1989
  • This paper aims at investigating the Demand Assigned Multiple Access(DAMA) system for the packet-switched Satellite Communication. An onboard processor of the multisport beam satellite incorporates the ground controller to macimize the packet transmissions for each slot. 'Request Following' trnasmission mode is introduced as a transmission strategy of ground station under the control of its zone controller. The combined scheme of reservation channel access and contention channel access was proposed by Lee & Mark[3] for improving the Delay-Throughput performance. Our scheme provides less communication delay of approximately max. 200msec for achieving the corresponding throughput than the Lee & Mark's work does. Delay versus Throughput curves as well as Delay versus Traffic parameter curves are obtained. Numerical results obtained through the analysis and by the computer simulation show that the proposed scheme provides the low average packer delay even under the condition that the number of transponders (M)is below the half of the number of zones(N).

  • PDF

A Study on a Tracking Method of Telemetry Signal using Self-Slaving (Self-Slaving을 이용한 원격측정 신호추적 기법 연구)

  • Lee, Sung-Pil
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.11 no.3
    • /
    • pp.50-57
    • /
    • 2008
  • A telemetry ground station has a highly directional, parabolic tracking antenna to receive a weak telemetry signal from a target at a distance. The tracking antenna with narrow beam-width normally uses the auto-track method for the target tracking. This paper presents several issues in the auto-track method and introduces a new tracking method using Self-Slaving technique. Self-Slaving means that the tracking antenna is slaved to not data measured by RADAR but GPS/INS informations received by the telemetry system for pointing. The Self-Slaving method shows good performance in comparison with auto-track method.

Optical Properties of Long Wave Infrared Spoof Plasmon using Hexagonal Periodic Silver Hole Arrays

  • Lee, Byungwoo;Kwak, Hoe Min;Kim, Ha Sul
    • Applied Science and Convergence Technology
    • /
    • v.25 no.2
    • /
    • pp.42-45
    • /
    • 2016
  • A two-dimensional metal hole array (2DMHA) structure is fabricated by conventional photo-lithography and electron beam evaporation. The transmittance of the 2DMHA is measured at long wave infrared (LWIR) wavelengths (${\lambda}{\sim}10$ to $24{\mu}m$). The 2DMHA sample shows transmittance of 70 and 67% at $15.4{\mu}m$ due to plasmonic resonance with perforated silver and gold thin films, respectively, under surface normal illumination at LWIR wavelengths. The measured infrared spectrum is separated into two peaks when the size of the hole becomes larger than a half-pitch of the hole array. Six degenerated plasmon modes (1,0) at the metal/Si surface split to three modes at an incident beam angle of $45^{\circ}$ with respect to the surface normal direction, and wavelength shifts of the transmitted spectrum are observed in a red shift and blue shift at the same time.