• Title/Summary/Keyword: gusts

Search Result 45, Processing Time 0.026 seconds

2013년 8월 6일 한반도에서 발달한 다세포(Multicell) 대류계의 특성 분석 (Characteristic Analysis of Multicell Convective System that Occurred on 6 August 2013 over the Korean Peninsula)

  • 윤지현;민기홍
    • 대기
    • /
    • 제26권2호
    • /
    • pp.321-336
    • /
    • 2016
  • Damages caused by torrential rain occur every year in Korea and summer time convection can cause strong thunderstorms to develop which bring dangerous weather such as torrential rain, gusts, and flash flooding. On 6 August 2013 a sudden torrential rain concentrated over the inland of Southern Korean Peninsula occurred. This was an event characterized as a mesoscale multicellular convection. The purpose of this study is to analyze the conditions of the multicellular convection and the synoptic and mesoscale nature of the system development. To this end, dynamical and thermodynamic analyses of surface and upper-level weather charts, satellite images, soundings, reanalysis data and WRF model simulations are performed. At the beginning stage there was a cool, dry air intrusion in the upper-level of the Korean Peninsula, and a warm humid air flow from the southwest in the lower-level creating atmospheric instability. This produced a single cell cumulonimbus cloud in the vicinity of Baengnyeongdo, and due to baroclinic instability, shear and cyclonic vorticity the cloud further developed into a multicellular convection. The cloud system moved southeast towards Seoul metropolitan area accompanied by lightning, heavy precipitation and strong wind gusts. In addition, atmospheric instability due to daytime insolation caused new convective cells to develop in the upstream part of the Sobaek Mountain which merged with existing multicellular convection creating a larger system. This case was unusual because the system was affected little by the upper-level jet stream which is typical in Korea. The development and propagation of the multicellular convection showed strong mesoscale characteristics and was not governed by large synoptic-scale dynamics. In particular, the system moved southeast crossing the Peninsula diagonally from northwest to southeast and did not follow the upper-level westerly pattern. The analysis result shows that the movement of the system can be determined by the vertical wind shear.

돌풍 대비용 직주 배치에 따른 계류안전성 민감도 분석 연구 (A Study on Analysis of Mooring Safety Sensitivity According to the Arrangement of Bitt Against Gust)

  • 김승연
    • 해양환경안전학회지
    • /
    • 제26권7호
    • /
    • pp.767-776
    • /
    • 2020
  • 최근 지구온난화에 따른 기후변화에 따라 과거와는 다른 양상의 기상 변화가 발생하고 있으며, 해수 온도 상승으로 태풍의 대형화와 강도증가가 발생하고 있다. 이에 따라 선박이 접안 중 갑작스러운 돌풍 발생시 선박의 계류안전성 확보를 위해 사용할 수 있는 돌풍 대비용 직주의 필요성이 증대되고 있다. 본 연구에서는 항만 및 어항 설계기준상 곡주 및 직주 배치 기준을 분석하고 계류안전성 평가프로그램을 사용하여 12개 시나리오에 따른 직주 사용시 계류안전성 민감도 분석을 수행하였다. 평가 결과, 돌풍 대비용 직주에 선수 및 선미 브레스트라인을 추가하였을 경우, 일반적인 형태의 계류라인 배치에 비해 계류요소값이 감소하는 것으로 분석되었다. 본 연구 결과는 접안선박 및 항만의 특성을 고려한 돌풍 대비용 직주 배치를 제안하기 위한 기초 자료로 활용될 수 있으며, 부두에서 직주의 배치는 돌풍 발생시 선박운항자 측면에서 선박의 계류안전성을 확보하기 위한 효율적인 방안이 될 것으로 사료된다.

Antenna Control System Using Step Tracking Algorithm with H$_{\infty}$ Controller

  • Cho, Chang-Ho;Lee, Sang-Hyo;Kwon, Tae-Yong;Lee, Cheol
    • International Journal of Control, Automation, and Systems
    • /
    • 제1권1호
    • /
    • pp.83-92
    • /
    • 2003
  • The outdoor antenna servo system is subject to has significant torque disturbances from wind pressures and gusts on the antenna structures, as well as bearing and aerodynamic frictions. This control system should provide a sharp directivity in spite of the environmental disturbances and internal uncertainties. Therefore, the implementation of a real-time controller is necessary for the precise generation of the reference signal and robust tracking performance. In this paper, the discrete-time controller for the quick tracking of a target communication satellite is designed by applying the sampled-data $H_{\infty}$ control theory along with the reference signal generated by an improved conventional step-tracking algorithm. The sampled-data $H_{\infty}$controller demonstrates superior robustness for the longer sampling period when compared with a simple PID controller.

편심배치방식 자기부상 제어시스템의 2차 현가에 대한 동특성 해석 (Dynamic Performance Analysis for Secondary Suspension of Maglev Control Systems with a Combined Lift and Guidance)

  • 김종식
    • 한국정밀공학회지
    • /
    • 제9권1호
    • /
    • pp.53-65
    • /
    • 1992
  • For improving the performance of maglev systems with a combined lift and guidance, it is suggested that the multivariable control systems and a secondary suspension should be added. The former is required to reject both track irregularities in vertical disturbances and wind gusts in lateral disturbances, and the latter to guarantee passengers against an unsatisfied criteria in ride quality. In this paper, bond graph model for the study of nonlinear dynamics of maglev systems with a combined lift and guidance is presented briefly. And, the secondary suspension is analyzed to understand the role of stiffness and damping factors in passive devices. Finally, LQG/LTR mulitivariable control systems are designed for the overall maglev systems with and without secondary suspension, and then the system performances in these two cases are evaluated.

  • PDF

Prediction of downburst-induced wind pressure coefficients on high-rise building surfaces using BP neural network

  • Fang, Zhiyuan;Wang, Zhisong;Li, Zhengliang
    • Wind and Structures
    • /
    • 제30권3호
    • /
    • pp.289-298
    • /
    • 2020
  • Gusts generated by downburst have caused a great variety of structural damages in many regions around the world. It is of great significance to accurately evaluate the downburst-induced wind load on high-rise building for the wind resistance design. The main objective of this paper is to propose a computational modeling approach which can satisfactorily predict the mean and fluctuating wind pressure coefficients induced by downburst on high-rise building surfaces. In this study, using an impinging jet to simulate downburst-like wind, and simultaneous pressure measurements are obtained on a high-rise building model at different radial locations. The model test data are used as the database for developing back propagation neural network (BPNN) models. Comparisons between the BPNN prediction results and those from impinging jet test demonstrate that the BPNN-based method can satisfactorily and efficiently predict the downburst-induced wind pressure coefficients on single and overall surfaces of high-rise building at various radial locations.

기준모델 적응제어에 의한 유도 비행체의 자동조종장치 설계에 관한 연구 (Design of autopilot for a guided missile using model reference adaptive control)

  • 임호;박정일;김원규;박종국
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.499-502
    • /
    • 1989
  • This paper is concerned with the stability analysis and the design of an auto pilot using direct model reference adaptive control for BTT missile with unknown dynamics when subjected to the longitudinal and lateral gusts. A motion of BTT missile can be separated into the longtudinal and lateral motione. The proposed algorithm is introduced different leakage terms about each motion into adaptation so as to prevent drift of the adaptive gain and alleviate gust effects and cross-coupling. The algorithm is applied to the 6DOF motion of an EMRAAT missile.

  • PDF

풍력터빈 출력예측 및 극한하중평가에 관한 연구 (A Study on the Ultimate Load Assessment and the Performance Prediction of a Wind Turbine)

  • 김범석;음학진;김만응
    • 대한기계학회논문집B
    • /
    • 제33권5호
    • /
    • pp.326-333
    • /
    • 2009
  • Design life-time of a wind turbine is required to be at least 20 years. In the meantime, the wind turbine will experience a lot of load cases such as extreme loads and fatigue loads which will include several typhoons per year and extreme gusts with 50 years recurrence period as well as endless turbulence flow. Therefore, IEC61400-1 specifies design load cases to be considered in the wind turbine design and requires the wind turbine to withstand the load cases in various operational situations. This paper investigates the ultimate loads which the wind turbine will experience for 20 years and their characteristics based on the IEC61400-1 using an aero-elastic software, GH-Bladed. And the performance characteristics of a wind turbine such as electrical power generation and annual energy yield are also investigated.

Typhoon damage analysis of transmission towers in mountainous regions of Kyushu, Japan

  • Tomokiyo, Eriko;Maeda, Junji;Ishida, Nobuyuki;Imamura, Yoshito
    • Wind and Structures
    • /
    • 제7권5호
    • /
    • pp.345-357
    • /
    • 2004
  • In the 1990s, four strong typhoons hit the Kyushu area of Japan and inflicted severe damage on power transmission facilities, houses, and so on. Maximum gust speeds exceeding 60 m/s were recorded in central Kyushu. Although the wind speeds were very high, the gust factors were over 2.0. No meteorological stations are located in mountainous areas, creating a deficiency of meteorological station data in the area where the towers were damaged. Since 1995 the authors have operated a network for wind measurement, NeWMeK, that measures wind speed and direction, covering these mountainous areas, segmenting the Kyushu area into high density arrays. Maximum gusts exceeding 70 m/s were measured at several NeWMeK sites when Typhoon Bart (1999) approached. The gust factors varied widely in southerly winds. The mean wind speeds increased due to effects of the local terrain, thus further increasing gust speeds.

Ultimate strength of long-span buildings with P.E.B (Pre-Engineered Building) system

  • Lee, Seong-Hui;Kim, Young-Ho;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • 제19권6호
    • /
    • pp.1483-1499
    • /
    • 2015
  • With the improvement of the quality of construction materials and the development of construction technologies, large-scale long-span steel frame buildings have been built recently. The P.E.B system using tapered members is being employed as an economically-efficient long-span structure owing to its advantage of being able to distribute stress appropriately depending on the size of sectional areas of members. However, in December 2005 and in February 2014, P.E.B buildings collapsed due to sudden loads such as snow loads and wind gusts. In this study, the design and construction of the P.E.B system in Korea were analyzed and its structural safety was evaluated using the finite element analysis program to suggest how to improve the P.E.B system in order to promote the efficient and rational application of the system.

Limitations for the control of wind-loaded slender bridges with movable flaps

  • Kirch, Arno;Peil, Udo
    • Wind and Structures
    • /
    • 제15권5호
    • /
    • pp.441-462
    • /
    • 2012
  • This article presents theoretical investigations on techniques for the improvement of the dynamic characteristics of slender bridges under wind action. Aerodynamically effective control shields are applied as controlled actuators. The first part of the article describes the modelling of the uncontrolled aeroelastic system. Acting aerodynamic forces are consistently characterised using linear time-invariant transfer elements in terms of rational functions. On this basis, two configuration levels of the uncontrolled system are represented with linear time-invariant state-space models and investigated. The second part of the article addresses controller design and the behaviour of the controlled aeroelastic system. Both fundamental limits for stabilisation and the efficiency for attenuating the influence of gusts are described for different actuator mechanisms. The results are derived and discussed with methods of control theory.