• Title/Summary/Keyword: guide plate

Search Result 244, Processing Time 0.027 seconds

Design and Analysis of Composite Multilayer Surface-Antenna-Structure (복합재료 다층 표면안테나구조의 설계 및 응력해석)

  • 유치상;황운봉
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.802-805
    • /
    • 2003
  • Structural surface becomes an antenna. The integration of antennas into structural body panels is a new high payoff technology. It emerged from the need to improve structural efficiency and antenna performance. In this paper, we developed new design concept for the structural surface which transmits and receives the electromagnetic signals, and it is termed Surface-Antenna-Structure (SAS). Design procedure was presented including structure design. material selection and design of antenna elements, which was processed according to the communication with KORSAT satellite at Ku-Band (12.25-12.75 GHz). The final demonstration article was 350$\times$200$\times$7.5mm flat antenna panel. Experimental results for antenna performances were in good agreements with design requirements. Also structural analysis was performed with SAS. estimating stress distributions under simply supported condition with Laminated Plate Theories and Wavier Solutions. The SAS concept can be extended to give a useful guide to manufacturers of structural body panels as well as antenna designers. promising innovative future communication technology.

  • PDF

Hydroelastic Responses of Nonerctangular Floating Airports Considering the Shape of Control Tower (관제탑 형상에 의한 불균일한 부유식 해상공항의 유탄성 운동)

  • 이호영;곽영기;박종환
    • Journal of Ocean Engineering and Technology
    • /
    • v.16 no.2
    • /
    • pp.32-37
    • /
    • 2002
  • Very Large Floating Structures have been planned for effective utilization of ocean space in recent years. The nonerctangular VLFS usually has a control tower to guide airplane securely. This paper presents an effective method for calculating the wave induced hydroelastic responses of VLFS considering the effect of control tower-shapes. The source and dipole distribution method is used to calculate the plate. The rigidity matrix for VLFS is formulated by finite element method using a plate theory. The calculated results for nonerctangular VLFS with a control tower are compared with those for VLFS without a control tower.

Computer simulation of scattering light guide plate for LCD blacklight unit (LCD backlight용 산란형 도광판의 전산모사)

  • 김경찬;오영식;정주영;하기룡;강신원
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.02a
    • /
    • pp.136-137
    • /
    • 2001
  • LCD(Liquid Crystal Display)는 크게 투과형과 반사형으로 나눌 수 있으며 투과형 LCD의 전력소모중 약 70%를 차지하는 부분이 백라이트 유닛이다. 다른 차세대 도광판 연구와는 달리 경사면을 이용한 방법이 아니라 도광판 속에서의 산란을 조절하는 방식이다. 기존 도광판은 그림 1-(b)처럼 밑면에 dot pattern을 인쇄하여 dot의 크기, 001의 간격을 이용한 것이다. (중략)

  • PDF

An Experimental Study on the Thermal Performance of Air Filled Thermal Diode (공기를 작동 유체로 하는 열다이오드의 열성능에 관한 실험적 연구)

  • Pak, Ee-Tong;Jang, Young-Geun;Hwang, In-Ju
    • Solar Energy
    • /
    • v.17 no.2
    • /
    • pp.35-42
    • /
    • 1997
  • Thermal diode is a device which allows heat to be transferred in one direction by convection due to difference of density of fluid, and blocks heat flow in the opposite direction. Vertical plate for heat collection and radiation are of utility for design of thermal diode. It was considered the transient and steady state of air filled thermal diode with guide vane which combined rectangular and parallelogrammic shape enclosures. $Gr^*$ was kept constantly on $1.11{\times}10^{10}{\sim}1.4{\times}10^{10}$ and error range was ${\pm}3%$ during the experiment. Nu was examined when inclined angle are $15^{\cir\c}\;and\;45^{\circ}$ and, also the experiments was carried out with and without guide vane as well. Specially, Nu was linearly increased due to increase of $Gr^*$, and the effect of guide vane and dimensionless channel depth was sensitive. Developed state of temperature began at dimensionless time $0.5{\sim}0.6$ due to variation of inclined angle, which is characteristic of system.

  • PDF

Die System for Avoiding Thickness Reduction along the Bent Corner in Warm Plate Forging of an Axle Housing (액슬하우징의 온간 후판단조에서 굽힘 변형된 모서리에서 발생하는 두께 감소 방지를 위하여 고안된 금형 시스템)

  • Kim, J.S.;Kim, K.S.;Shim, S.H.;Eom, J.G.;Joun, M.S.
    • Transactions of Materials Processing
    • /
    • v.19 no.8
    • /
    • pp.447-451
    • /
    • 2010
  • In this paper, a useful die system for warm plate forging of a large axle housing of heavy-duty trucks is presented. A die system composed of material flow guide pin as well as upper die and lower die is proposed to reduce the inherent thickness reduction along the bent corner of the product which deteriorates structural strength and fatigue life in its service. The role of the pin assembled in the upper die is to prevent formation of sharp corner in early forming stage and to supply material in the lower die cavity sufficient enough to thicken the bent corner at the final stroke. The mechanism of the die system is given and its effect on corner thickness of the product is revealed by two-dimensional finite element analysis under plain strain assumption. Three-dimensional finite element solutions are also given to verify validity of the two dimensional approach and to show the mechanics of the die system in detail. The die system has been successfully applied to manufacturing the axle housing of heavy-duty trucks.

Investigation of Damping Ratio of Steel Plate Concrete (SC) Shear Wall by Lateral Loading Test & Impact Test (횡방향 가력실험 및 충격실험을 통한 강판콘크리트(SC) 전단벽의 감쇠비 평가)

  • Cho, Sung Gook;So, Gi Hwan;Park, Woong Ki
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.79-88
    • /
    • 2013
  • Steel plate concrete (SC) composite structure is now being recognized as a promising technology applicable to nuclear power plants as it is faster and suitable for modular construction. It is required to identify its dynamic characteristics prior to perform the seismic design of the SC structure. Particularly, the damping ratio of the structure is one of the critical design factors to control the dynamic response of structure. This paper compares the criteria for the damping ratios of each type of structures which are prescribed in the regulatory guide for the nuclear power plant. In order to identify the damping ratio of SC shear wall, this study made SC wall specimens and conducted experiments by cyclic lateral load tests and vibration tests with impact hammer. During the lateral loading test, SC wall specimens exhibited large ductile capacities with increasing amplitude of loading due to the confinement effects by the steel plate and the damping ratios increased until failure. The experimental results show that the damping ratios increased from about 6% to about 20% by increasing the load from the safe shutdown earthquake level to the ultimate strength level.

Noise and vibration reductions in exhaust duct system of cogeneration power plants (열병합발전소 배기 덕트 시스템의 소음 진동 저감)

  • Kim, W.H.;Joo, W.H.;Bae, J.G.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.641-646
    • /
    • 2004
  • Noise and vibration was encountered in exhaust duct system which is connected with a gas turbine and a heat recovery steam generator(HRSG) of a cogeneration power plants. Especially, these problems occurred when water was added to the fuel injection to reduce NOx contents of the exhaust gas. Through the cavity mode analysis and measurements, It was concluded that these problems occurred due to the acoustic resonance between the duct cavity mode and the excitation force induced by turbulent gas flow during water injection. To reduce the noise and vibration, optimal baffle plate to change the cavity mode was installed inside of duct and noise levels of about 8 dB(A) are reduced in duct system. The effects of baffle plate and guide vane to the HRSG or inlet duct vibration were also evaluated and it was verified that there is no relation to the resonance phenomena. So, vibration of inlet duct was easily reduced by the reinforcement of structures.

  • PDF