• Title/Summary/Keyword: guide length

Search Result 217, Processing Time 0.031 seconds

ACL Reconstruction using Transtibial Femoral Tunnel at 10 or 2 O'clock Position - Technical Note - (10시 혹은 2시 방향의 경경골 대퇴 터널을 이용한 전방 십자 인대 재건술 - 수술 수기 -)

  • Cho, Sung-Do;Ko, Sang-Hun;Park, Mun-Soo;Jung, Kwang-Hwan;Cha, Jae-Ryong;Gwak, Chang-Youl;Kim, Sang-Woo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.209-213
    • /
    • 2006
  • Purpose: Conventional transtibial approach for the anterior cruciate ligament (ACL) reconstruction tended to place the femoral tunnel in too vertical position (11 or 1 o'clock), which could provide the postoperative anteroposterior (AP) stability but not provided the rotational stability. Therefore we present a surgical technique to make the transtibial femoral tunnel at 10 or 2 o'clock position. Surgical approach: To make a transtibial femoral tunnel at the 10 or 2 o'clock position, the direction and position of the tibial drill guide was important. We set the tibial drill guide at $40{\sim}45$ degrees and the intraarticular guide tip was 1 mm anterior and medial to the conventional site. The starting point for the guide pin on the proximal tibia was proximal to the pes anserinus and anterior to the medial collateral ligament. The tibial tunnel was initially drilled 1mm less than the diameter of the graft. Then femoral offset guide could be easily placed at 10 or 2 o'clock position through the tibial tunnel. The tibial tunnel and the femoral tunnel of 30 mm in length were made with the reamer that was same size with the graft. Conclusion: We report a surgical technique to create a transtibial femoral tunnel at 10 or 2 o'clock position in ACL reconstruction to provide the rotational stability as well as the AP stability.

  • PDF

The Effectiveness of Ultrasound-guide Steroid Injection According to Morton's Neuroma Size (모톤씨 신경종 크기에 따른 초음파 유도하 스테로이드 주사 효과의 비교분석)

  • Kim, Hak Jun;Hur, Chang Ryong;Kim, Jae Kyun;Jang, Kyu Seon
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.5 no.2
    • /
    • pp.61-65
    • /
    • 2012
  • Purpose: The aim of this study was to evaluate the effectiveness of ultrasound-guide steroid injection according to Morton's neuroma size. Materials and Methods: From October 2008 to September 2011, 17 patients (23 cases) diagnosed with Morton's neuroma were investigated. All cases were female and mean age was 52.6 years old. Neuroma were measured by the horizontal and longitudinal length of the mass and underwent ultrasound-guided steroid (5 mg dexamethasone) injection. The efficacy of the injection was determined by Visual Analogue Scale pain score and patient satisfaction(subdivided 4 group-much improved, improved, not improved, aggrevation) Results: 7 of 23(30.4%) cases showed much improved and improved satisfaction and mean longitudinal and horizontal length were $0.71{\pm}0.39cm$ and $0.47{\pm}0.24cm$, respectively. 16 of 23(69.6%) cases showed not improved and aggrevation satisfaction and mean longitudinal and horizontal length were $0.83{\pm}0.42cm$ and $0.54{\pm}0.14cm$, repectively. There was a significant difference in VAS and patient satisfaction in case longitudinal and horizontal length were smaller than 0.5 cm and 0.4 cm. (p<0.05) Conclusion: The ultrasonography is a important modality in diagnosis and treatment of morton's neuroma. Ultrasound-guide steroid injection is effective in case longitudinal and horizontal length were smaller than 0.5 cm and 0.4 cm, respectively.

  • PDF

Usefuless of Multi-functional Gastroduodenal Coil Catheter with Phantom (팬텀을 이용한 다기능 위.십이지장관 코일 카테타의 유용성 평가)

  • Lim, Jin-Oh;Kim, Tae-Hyung;Jung, Yang-Hwa;Choi, Won-Chan;Shin, Ji-Hoon;Song, Ho-Young
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.21-26
    • /
    • 2003
  • To evaluate the newly designed gastroduodenal coil catheter:in-vitro test. The coil catheter that we made in our laboratory was 150 cm. The coil that is made of stainless steel wire was composed 1.3 mm inner diameter and this coil spring was covered with heat-shrinkable polyethylene tube. To measure the length under fluorocopy, 8 radiopaque marks were attached at 5 cm, 10 cm, 11 cm, 12 cm, 13 cm, 14 cm, 15 cm, 20 cm apart from distal end of the catheter and 6, 2, 1 pores were made at 7 cm, 13 cm, 19 cm apart from the distal end. Radio-opacity and the amount of injected contrast was investigated in formerly used 5 Fr. vessel catheter, which is possible in measuring length, and newly designed coil catheter. Film density was tested for radio-opacity with autodensitometer. For measuring the volume of injected salin, the catheter was located in the acryl box(26 cm, 3 cm, 16 cm) that divided into 4 chambers. After injection 50 cc of contrast with autoinjector, the contrast's quantity in each chamber was measured with and without over the guide wire. Radio-opacity was 0.51 in 5 Fr. vessel catheter, 0.31 in newly made catheter. The amount of injected contrast was measured. In case of 5 Fr. vessel catheter, the amount was 99.5% from the distal part, there was no difference between with and without the guide wire. Otherwise, using a coil catheter, the pacentage the ejected saline was 1.17%, 18.8%, 41.8%, 38.2% from the distal part with the guide wire, 19.5%, 32.6%, 27.7%, 20.3% without the guide wire. Compare with formerly established catheter, this new coil catheter is easy to measure the length thanks to easy confirming under fluoroscopy and excellent in injecting contrast. Therefore, newly designed gastrointestinal catheter seems to be useful in gastrointestinal intervention procedure.

  • PDF

Shape Factor Analysis of Fresh Red Pepper Affecting the Performance of Unfolding, Arranging and Cutting (전개 .정렬 . 절단 성능에 영향을 미치는 홍고추 형상 요인 분석)

  • 나우정;이승규;송대빈;김영복;이태곤
    • Journal of Biosystems Engineering
    • /
    • v.26 no.6
    • /
    • pp.563-570
    • /
    • 2001
  • To develop a stalk detaching system the effect of shape factor of red pepper affecting the performance of unfolding, arranging and cutting was analysed. The obtained results are as follows : By cutting experiment, it was found that the bending of stalk affected the cutting rate of stalk, and that the bending of body increased the amount of peppers that were expelled from the cutting guide by conveying brush. The ratios, 'bending length of a body/body length'and 'bending length of a stalk/stalk length', could be used as criteria far abnormality of body and stalk of peppers, respectively. As a result of experiment, it was concluded that mechanical treatment would be difficult for the peppers with indexes greater than 0.4 and 0.3 fur body bending and stack bending. respectively. So, these indexes were used as criteria for distinguishing abnormality from normality of peppers. In the unfolding unit, conveyance of peppers was impossible for both of normal and abnormal ones at the inclination angle of 10°, especially, at the frequency of 8.3 Hz peppers maintained stationary state. At the inclination angle of 20°, both of normal and abnormal peppers showed similar tendencies, but abnormal ones showed an accumulation trend gradually with increased feeding speed. In the arranging unit, conveyance of peppers was almost impossible for both of normal and abnormal ones at the inclination angle of 20°, showing almost no difference between the conveyances of normal and abnormal ones. In the case of the inclination angle of 30°, at the condition of the feeding speeds and frequency corresponding 0.06 m/s, 0.08 m/s and 8.3 Hz, respectively, the passing time of the abnormal peppers on the arranging plate increased rapidly.

  • PDF

The Influence of the Sense of Place on Regeneration Space using Idle Industrial Facilities on Visitors' Satisfaction and Length of Stay - Focused on Visitors of Mullae Art Village - (유휴산업시설 재생공간의 장소성이 방문만족도와 체류시간에 미치는 영향 - 문래예술창작촌의 방문자들을 대상으로 -)

  • Yoon, Han;Yun, Hee Jeong
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.46 no.4
    • /
    • pp.1-10
    • /
    • 2018
  • The purpose of this study is to analyze the influence of visitors' sense of place on regeneration space using idle industrial facilities on visitors' satisfaction and length of stay. For this purpose, this study selected Mullae Art Village in Seoul as a study site and conducted a questionnaire survey focused on visitors. The results of an exploratory factor analysis (EFA), reliability analysis and multiple regression analysis show that among the sense of place factors of Mullae Art Village 'Attractiveness' and 'Meaningfulness' have a positive influence on visitor satisfaction and length of stay. 'Attractiveness' was found to be the most influential factor. 'Historicity' was found to have no effects on visitor satisfaction and length of stay. In addition, visitor satisfaction has a positive influence on duration of stay. These results suggest that it is important to analyze the sense of place of idle industrial facilities. It will be a useful guide for urban space planners in revitalizing and establishing a marketing strategy for these spaces.

Effect of the Microtip Length in a Slot-die Head on Fine Stripe Coatings (미세 스트라이프 코팅에 미치는 슬롯 다이 헤드 마이크로 팁 길이의 영향)

  • Lee, Jinyoung;Park, Jongwoon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.4
    • /
    • pp.69-74
    • /
    • 2019
  • The aim of this work is to investigate the effect of the microtip length in a slot-die head on coating of a fine poly(3,4-ethylenedioxythiophene):poly(4-styrenesulfonate) (PEDOT:PSS) stripe. To this end, we have employed a meniscus guide with a 150-㎛-wide microtip and performed roll-to-roll slot-die coatings by varying its length between 500 ㎛ and 50 ㎛. When the microtip length is 150 ㎛ or shorter, we have observed three unexpected phenomena; 1) though the solution spreads much wider than the microtip width, yet the coated stripe width is almost the same as the microtip width, 2) the stripe width decreases, but the stripe thickness is rather increased with increasing coating speed at a fixed flow rate, 3) we obtain stripes much narrower than the microtip width at high coating speeds. It is due to the fact that 1) the meniscus is not well controlled by a short microtip, 2) the main stream of solution from the outlet is very close to the substrate and thus the distributed solution along the head lip merges with the main stream, and 3) the solution is not spread over the entire microtip end at high coating speeds, causing a tiny wobble in the meniscus. Using the 150-㎛-wide and 250-㎛-long microtip, we have fabricated 153-㎛-wide and 94-nm-thick PEDOT:PSS stripe at the maximum coating speed of 13 mm/s. To demonstrate its applicability in solution-processable organic light-emitting diodes (OLEDs), we have also fabricated an OLED device with the fine PEDOT:PSS stripe and obtained strong light emission from it.

A Study on Machinability of SM55C for Deep Hole Drilling (Deep Hole 가공시 SM55C의 절삭성에 관한 연구)

  • 이충일
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.177-182
    • /
    • 1997
  • The purpose of this study is to analyze how tools, guide bush type and the change of cutting speed have effects on the diameter of cutting hole, surface roughness of workpiece and roundness during the deep hole machining of SM55C with solid BTA drill by using BTA drilling system through experiment. Conclusion reached is as follows. (1) The diameter was expanded for 25${\mu}{\textrm}{m}$ at the first section and then was reduced 0${\mu}{\textrm}{m}$ and 15${\mu}{\textrm}{m}$ respectively at the 10m and 20m section comparing to the diameter of tool with respect to the variation of cutting length. (2) It was proved that roughness was below 12S for the whole section of cutting length. (3) The roundness has been below 12${\mu}{\textrm}{m}$. Regarding the polygon phenomenon, it has bee proved that not only uneven number of angle but also even number (quadrilateral, elliptical) of angle were made. (4) Variation of diameter, surface roughness of workpiece and roundness turned out to ve the best at 70m/min of cutting speed, 0.15mm/rev of feed.

  • PDF

150 nm Pitch Measurement using Metrological AFM (길이 소급성을 갖는 AFM을 이용한 150nm 피치 측정)

  • ;I. Misumi;S. Gonda;T. Kurosawa
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.264-267
    • /
    • 2003
  • Pitch measurements of 150 nm pitch one-dimensional grating standards were carried out using an contact mode atomic force microscopy(C-AFM) with a high resolution three-axis laser interferometer. It was called as 'Nano-metrological AFM' In Nano-metrological AFM, Three laser interferometers were aligned well to the end of AFM tip. Laser sources of the three-axis laser interferometer in the nano-metrological AFM were calibrated with an I$_2$-stablilzed He-Ne laser at a wavelength of 633 nm. So, the Abbe error was minimized and the result of the pitch measurement using the nano-metrological AFM has a traceability to the length standard directly. The uncertainty in the pitch measurement was estimated in accordance with the Guide to the Expression of Uncertainty in Measurement(GUM). The Primary source of uncertainty in the pitch-measurements was derived from repeatability of pitch-measurement, and its value was approx 0.186 nm. Expanded uncertainty(k=2) of less than 5.23 nm was obtained. It is suggested that the metrological AFM is a useful tool for the nano-metrological standard calibration.

  • PDF

Measurement Uncertainty Analysis of Performance Test for Coordinate Measuring Machine (3차원 좌표 측정기 성능 시험법에 대한 측정 불확도 해석)

  • Lee, Seung-Pyo;Kang, Hyung-Joo;Ha, Sung-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.4
    • /
    • pp.91-99
    • /
    • 2009
  • Because of both precise measurement and efficient quality control, coordinate measuring machines(CMMs) have been widely used in the industry. The purpose of this paper is to present a method to estimate the CMM measurement uncertainty using design of experiments. A factorial design is applied to carry out the performance test proposed by ISO 10360 and to investigate CMM measurement errors associated to orientation and length of the length bar. In order to assess the measurement uncertainty for the performance test, an analysis of the uncertainty components that make up the uncertainty budget has been carried out. The procedure for evaluating the uncertainty of it follows GUM ("Guide to the expression of uncertainty in measurement"). The results show that the proposed method is suitable to investigate CMM performance and determine the contribution of machine variables to measurement uncertainty.

CFD APPLICATION TO THE REGULATORY ASSESSMENT OF FAC-CAUSED CANDU FEEDER PIPE WALL THINNING ISSUE

  • Kang, Dong-Gu;Jo, Jong-Chull
    • Nuclear Engineering and Technology
    • /
    • v.40 no.1
    • /
    • pp.37-48
    • /
    • 2008
  • Flow fields inside feeder pipes have been simulated numerically using a CFD (computational fluid dynamics) code to calculate the shear stress distribution, which is the most important factor in predicting the local regions of feeder pipes highly susceptible to FAC (flow-accelerated corrosion)-induced wall thinning. The CFD approach, with schemes used in this study, to simulate the flow situations inside the CANDU feeder pipes has been verified as it showed a good agreement between the investigation results for the failed feedwater pipe at Surry unit 2 plant in the U.S. and the CFD calculation. Sensitivity studies of the three geometrical parameters, such as angle of the first and second bends, length of the first span between the grayloc hub and the first bend, and length of the second span between the first and the second bends have been performed. CFD analysis reveals that the local regions of feeder pipes of Wolsung unit 1 in Korea, on which wall thickness measurements have been performed so far, are not coincident with the worst regions predicted by the present CFD analysis located in the connection region of straight and bend pipe near the inlet part of the bend intrados. Finally, based on the results of the present CFD analysis, a guide to the selection of the weakest local positions where the measurement of wall thickness should be performed with higher priority has been provided.