• Title/Summary/Keyword: growth fire

Search Result 352, Processing Time 0.026 seconds

Performance Analysis for Fire Suppression and Disaster Management R&D Projects (소방·방재 R&D 성과분석 연구)

  • Yoon, Jonghyun;Kim, Geunyoung;Lim, Hyeounjoon
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.2
    • /
    • pp.208-218
    • /
    • 2014
  • The growth of disaster/accident damage costs and related industries has increased the necessity of scientific and objective performance analysis for fire suppression and disaster management R&D projects. Most of R&D performance are both academic and public performance according to fire suppression and disaster management R&D projects during the period of 2004 to 2011. This research identified characteristics of performance types by research project teams and research development stages. The research outcome shows the usefulness of relevant performance objective settings by project teams, the evaluation of scientific technology fields, and proper research teams in research team selection process, considering research outcome characteristics by both research teams and research development stages. In addition, this research reveals the applicability of research outcomes to research performance management. This research suggests further studies for evaluation process and methods for including fire suppression and disaster management characteristics to the evaluation process.

A Study on Degradation Characteristic of High Strength Fire Resistance Steel for Frame Structure by Acoustic Emission (음향방출법에 의한 고강도 구조요 내화강의 열화특성에 관한 연구)

  • 김현수;남기우;강창룡
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2000.04a
    • /
    • pp.51-56
    • /
    • 2000
  • Demand for new nondestructive evaluations is growing to detect tensile crack growth behavior to predict long term performance of materials and structure in aggressive environments, especially when they are in non-visible area. Acoustic emission technique is well suited to these problems and has drawn a keen interests because of its dynamic detection ability, extreme sensitivity and location of growing defects. In this study, we analysed acoustic emission signals obtained in tensile test of high strength fire resistance steel for frame structure with time frequency analysis methods. The results obtained are summaries as follows ; In the T and TN specimen consisting of ferrite and pearlite grains, most of acoustic emission events were produced near yield point, mainly due to the dislocation activities during the deformation. However, B specimen under $600^{\circ}C$ - 10min had a two peak which was attribute to the presence of martensite phase. The first peak is before yield point the second is after yield point. The sources of second acoustic emission peak were the debonding of martensite-martensite interface and the micro-cracking of brittle martensite phase. In $600^{\circ}C$-30min to $700^{\circ}C$-60min specimens, many signals were observed from area before yield point and counts were decreased after yield point.

  • PDF

Safety Index of Korean Society Analyzed by Time Series (시계열로 분석한 한국사회의 사회안전지표)

  • Shin, Chang-Sub;Kim, Sung-Min;Hwang, Suk-Keun;Lee, Kyoung-Duck;Yee, Jae-Yeol
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.6 s.78
    • /
    • pp.55-63
    • /
    • 2006
  • Rapid economic growth in Korea, on the other side, has generated increase of multiple complex dangers. To take off dangers scattered in the Korean society and to conduct safe society for better life, it is needed to develop social safety index. Social safety index analyzed by time series could compare and estimate various social disasters, thus it act as the foundation to set up safety policy. The research has focused on 8 social safety indexes; natural disaster, fire, traffic accident, crime, industry accident, forest fire, collapse and explosion, and environmental pollution. To find out Korean society safety index analyzed by time series, the research analyzed changes of each safety indexes in 10 years since 1994. Looking at the changes of each indexes, traffic accident showed the most improvement overall the nation, with industrial accident and collapse and explosion rating second and third place. However, crime, fire and natural disaster get worse, and especially crime has turned worsened than any other divisions.

Fatigue Characteristics and its Nondestructive Evaluation of Fire-resistance Steel for Construction with Low Yield Ratio and High Strength (저항복비·고강도 구조용 내화강의 피로특성 및 비파괴평가)

  • Kim, H.S.;Nam, K.W.;Kang, C.Y.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.14 no.4
    • /
    • pp.212-219
    • /
    • 2001
  • The fatigue test was carried out to evaluate the fatigue characteristics of fire resistance steel for frame structure and heat affected zone (HAZ) by the one side Gas Metal Arc Welding (GMAW). In this paper, the fatigue crack growth behavior was investigated with the compact tension specimen of base metal and the HAZ according to chemical composition and rolling end temperature, respectively. And the acoustic emission signals obtained from the fatigue test were analyzed by the time-frequency analysis method as a nondestructive evaluation. Main results obtained are summarized as follows; The hardness was appeared softening phenomenon that weld metal and HAZ are lower than that of base metal. Fatigue life of welded specimen was longer than that of base metal. m was 3~4.5 in base metal and 3.8~5.8 in HAZ. The main frequency range of acoustic emission signal analyzed from time-frequency method is different with the range by noise and crack. Also, it could be classified that it was also generated by fracture mechanics of dimple, inclusion etc.

  • PDF

Anatomical and Physical Characteristics of Pinus Densiflora Wood Damaged by Forest Fire (산불 피해 소나무재의 해부 및 물리학적 특성)

  • Hwang, Won-Joong;Kwon, Goo-Joong;Kim, Nam-Hun
    • Journal of the Korean Wood Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.1-7
    • /
    • 2003
  • Anatomical and physical characteristics of damaged wood by forest fire and sound wood of Pinus densiflora were examined. Granular substances were found in resin canals, epithelial cells and ray parenchyma cells of damaged wood, but the other distinctive marks of wood structure in damaged wood were not observed. Damaged wood showed slightly higher relative crystallinity in outermost growth ring than sound wood. Green moisture content and water absorptions both in tangential and radial sections of damaged wood were lower than those of sound wood. There were no significant differences in shrinkage, swelling and basic density between damaged and sound woods.

A Study on the Efficiency Estimation of Halogen free Fire Resistance Cable (저독성 내화전선 케이블의 성능평가에 관한 연구)

  • 윤헌주;홍진웅;유동일;윤재선;곽동일
    • Fire Science and Engineering
    • /
    • v.16 no.1
    • /
    • pp.18-23
    • /
    • 2002
  • Efficiency estimation of toxicity free resistance cable experiments were conducts to understand toxicity free fire ersistance polyolefin insulation material and smoke density characteristic and combustion gas corrosion analysis. A main cause of fire-growth and generating toxic gas when it burns, should be dealt with great care in life safety design. Similar patterned fire incidents such as, Inchon Live-Hof Pub Restaurant as, Sea-land Children Resort have proven that serious loss of lives were caused by hazardous gas generated fire resistance cable materials. In this paper, Referenced documents were ASTM E662 standard test method for specific Ds genalated by solid materials. The furnace control system shall maintain the required irradiance level under steady-state condition with the chamber door closed of 2.5$\pm40.04〔w/$\textrm{cm}^2$〕for 20 min. According to the results of the smoke density analysis of NFR-8 and FR-PVC the highest decomposition flaming smoke density range of NFR-8 and FR-PVC were 25.2 to 37.5 and 51.1 respectively. Nonflaming smoke density range of NFR-8 and FR-PVC were 100.4 to 112.2 and 126.5 to 398.8. Also, the fire gases was occurred carbon monoxide and decomposition than in polyolefin due to incomplete combustion of PVC which has high content of carbon in chemical compound.

The Relationship between Characteristics of Forest Fires and Spatial Patterns of Forest Types by the Ecoregions of South Korea (한국의 생태지역별 산불특성과 임상분포패턴과의 관계)

  • Lee, Byungdoo;Song, Jungeun;Lee, Myungbo;Chung, Joosang
    • Journal of Korean Society of Forest Science
    • /
    • v.97 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • It is necessary to examine relationship between spatial patterns of forest types and characteristics of forest fires for efficient management of fire and forest. By the ecoregions of South Korea, we computed landscape indices for whole types of forests(landscape level) and pine forests(class level), and analyzed characteristics of forest fires using statistics of forest fires from 1991 to 2006. We performed canonical correlation analysis to model the relationship between the landscape indices and the statistics of forest fires. At landscape level, forest patches were larger and more complex in the ecoregions which had higher percentage of forest area. At class level, pine forest patches were more complex and closer to neighbor patches in the coastal ecoregions. The ecoregions including metropolitan areas and cities had more frequent fire occurrences per 1,000ha, while mountainous coastal ecoregions had more burned areas and faster spread of fire growth rate. The canonical correlation between the landscape indices for pine forests and the statistics of forest fires was statistically significant at the 0.05 level and explained more than 70% of the variation in fire variables. The results showed that combustion time per fire was longer in the ecoregions which had larger and more aggregated pine forest patches.

Fire Regulation for Building Material of Organic Matter (유기물 건축내장재에 대한 화재법규)

  • Yoon, Kwan-Sun;Choi, Keun-Young
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.136-142
    • /
    • 2007
  • Due to the construction technique (or the construction culture) growth in and out of Korea, newly-developed products have been continuously released. Furthermore, all legislation and regulation that the World follows are gradually becoming unified. (e.g. FTA(Free Trade Agreement) with the United States was contracted, and inevitable FTA contraction with EU and China ), For this reason, it is considered that Korean fire regulation on building interior materials needs to be reviewed and compared with that of international standard so that it becomes legitimate and reasonable one. Especially, this reference is going to make a description of building interior materials' Flame retardant performance standard.

  • PDF

철갑소이탄에 의한 전투시스템 내 적재포탄의 순간화재에 관한 전산해석

  • Lee, Seung-Cheol;Jeon, U-Cheol;Lee, Hae-Pyeong;Lee, Heon-Ju
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.208-209
    • /
    • 2013
  • 본 연구에서는 철갑소이탄이 장갑을 관통한 후 전투시스템 내의 적재포탄(고폭탄 또는 추진제)에 피탄되었을 때 순간화재 발생확률에 대해 전산해석을 수행하였다. 장갑은 RHA 재질로 설정하였고, 장갑 두께를 5~30 mm까지 5 mm씩 증가시키며 전산해석을 실시하였다. 고폭탄은 COMPB, TNT, PBX가 사용되었으며 추진제는 ANB가 사용되었다. 본 해석은 Autodyn 프로그램을 사용하였으며, 순간화재 발생 여부를 해석하기 위해 Lee-Tarver ignition and growth model을 사용하였다. 해석 결과, 철갑소이탄이 고폭탄 TNT와 PBX에 피탄되었을 때, 순간화재 발생확률이 모두 100%를 나타내었으며, 고폭탄 COMPB의 경우, 0.8~0.08%로 나타났다. 추진제 ANB의 순간화재 발생확률은 3.8~3.6%로 나타났다.

  • PDF

Analysis of Secondary Battery Trends Using Topic Modeling: Focusing on Solid-State Batteries

  • Chunghyun Do;Yong Jin Kim
    • Asian Journal of Innovation and Policy
    • /
    • v.12 no.3
    • /
    • pp.345-362
    • /
    • 2023
  • As the widespread adoption and proliferation of electric vehicles continue, the secondary battery market is experiencing rapid growth. However, lithium-ion batteries, which constitute a majority of secondary batteries, present high risks of fire and explosion. Solid-state batteries are thus garnering attention as the next-generation batteries since they eliminate fire hazards and significantly reduce the risk of explosions. Against this background, the study aimed to analyze research trends and provide insights by examining 2,927 domestic papers related to solid-state batteries over the past decade (2013-2022). Specifically, we used topic modeling to extract major keywords associated with solid-state batteries research and to explore the network characteristics across major topics. The changes in research on solid-state batteries were analyzed in-depth by calculating topic dominance by year. The findings provide an overview of the emerging trends in domestic solid-state battery research, and might serve as a valuable reference in shaping long-term research directions.