• Title/Summary/Keyword: group detection

Search Result 1,677, Processing Time 0.027 seconds

Detection and Recovery of Failure Node in SAN-based Cluster Shared File System $SANique^{TM}$ (SAN 기반 클러스터 공유 파일 시스템 $SANique^{TM}$의 오류 노드 탐지 및 회복 기법)

  • Lee, Kyu-Woong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2609-2617
    • /
    • 2009
  • This paper describes the design overview of shared file system $SANique^{TM}$ and proposes the method for detection of failure node and recovery management algorithm. We also illustrate the characteristics and system architecture of shared file system based on SAN. In order to provide uninterrupted service, the detection and recovery methods are proposed under the all possible system failures and natural disasters. The various kinds of system failures and disasters are characterized and then the detection and recovery method are proposed in each disconnected computing node group.

Early Fire Detection System for Embedded Platforms: Deep Learning Approach to Minimize False Alarms (임베디드 플랫폼을 위한 화재 조기 감지 시스템: 오경보 최소화를 위한 딥러닝 접근 방식)

  • Seong-Jun Ro;Kwangjae Lee
    • Journal of Sensor Science and Technology
    • /
    • v.33 no.5
    • /
    • pp.298-304
    • /
    • 2024
  • In Korea, fires are the second most common type of disaster, causing large-scale damages. The installation of fire detectors is legislated to prevent fires and minimize damage. Conventional fire detectors have limitations in initial suppression of failures because they detect fires when large amounts of smoke and heat are generated. Additionally, frequent malfunctions in fire detectors may cause users to turn them off. To address these issues, recent studies focus on accurately detecting even small-scale fires using multi-sensor and deep-learning technologies. They also aim at quick fire detection and thermal decomposition using gas. However, these studies are not practical because they overlook the heavy computations involved. Therefore, we propose a fast and accurate fire detection system based on multi-sensor and deep-learning technologies. In addition, we propose a computation-reduction method for selecting sensors suitable for detection using the Pearson correlation coefficient. Specifically, we use a moving average to handle outliers and two-stage labeling to reduce false detections during preprocessing. Subsequently, a deep-learning model is selected as LSTM for analyzing the temporal sequence. Then, we analyze the data using a correlation analysis. Consequently, the model using a small data group with low correlation achieves an accuracy of 99.88% and a false detection rate of 0.12%.

Tumor Markers in Serum and Ascites in the Diagnosis of Benign and Malignant Ascites

  • Zhu, Fang-Lai;Ling, An-Sheng;Wei, Qi;Ma, Jie;Lu, Gang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.2
    • /
    • pp.719-722
    • /
    • 2015
  • Objective: To evaluate the values of 4 tumor markers in serum and ascites and their ascites/serum ratios in the identification and diagnosis of benign and malignant ascites. Materials and Methods: A total of 76 patients were selected as subjects and divided into malignant ascites group (45 cases) and benign ascites group (31 cases). Samples of ascites and serum of all hospitalized patients were collected before treatment. The levels of carcinoembryonic antigen (CEA), alpha fetoprotein (AFP), cancer antigen 125 (CA125) and carbohydrate antigen 19-9 (CA19-9) were detected by chemiluminescence (CLIA). Results: CEA, AFP and CA19-9 in both serum and ascites as well as CA125 in ascites were evidently higher in the malignant ascites group than in the benign ascites group (P<0.01). Malignant ascites was associated with elevated ascites/serum ratios for AFP and CA125 (P<0.01). The areas under receiver operating characteristic (AUROCs) of CEA and CA125 in ascites and the ratios of ascites/serum of AFP, CEA, CA125 and CA19-9 were all >0.7, suggesting certain values, while those of ascites CA19-9 and serum CEA were 0.697 and 0.629 respectively, indicating low accuracy in the identification and diagnosis of benign and malignant ascites. However, the AUROCs of the remaining indexes were <0.5, with no value for identification and diagnosis. Compared with single index, the sensitivity of combined detection increased significantly (P<0.05), in which the combined detection of CEA, CA19-9 and CA125 in ascites as well as the ratio of ascites/serum of CEA, CA19-9, CA125 and AFP had the highest sensitivity (98.4%) but with relevantly low specificity. Both sensitivity and specificity of combined detection should be comprehensively considered so as to choose the most appropriate index. Conclusions: Compared with single index, combined detection of tumor markers in serum and ascites can significantly improve the diagnostic sensitivity and specificity.

Cell ID Detection Schemes Using PSS/SSS for 5G NR System (5G NR 시스템에서 PSS/SSS를 이용한 Cell ID 검출 방법)

  • Ahn, Haesung;Kim, Hyeongseok;Cha, Eunyoung;Kim, Jeongchang
    • Journal of Broadcast Engineering
    • /
    • v.25 no.6
    • /
    • pp.870-881
    • /
    • 2020
  • This paper presents cell ID (cell identity) detection schemes using PSS/SSS (primary synchronization signal/secondary synchronization signal) for 5G NR (new radio) system and evaluates the detection performance. In this paper, we consider two cell ID detection schemes, i.e. two-stage detection and joint detection schemes. The two-stage detection scheme consists of two stages which estimate a channel gain between a transmitter and receiver and detect the PSS and SSS sequences. The joint detection scheme jointly detects the PSS and SSS sequences. In addition, this paper presents coherent and non-coherent combining schemes. The coherent scheme calculates the correlation value for the total length of the given PSS and SSS sequences, and the non-coherent combining scheme calculates the correlation within each group by dividing the total length of the sequence into several groups and then combines them non-coherently. For the detection schemes considered in this paper, the detection error rates of PSS, SSS and overall cell ID are evaluated and compared through computer simulations. The simulation results show that the joint detection scheme outperforms the two-stage detection scheme for both coherent and non-coherent combining schemes, but the two-stage detection scheme can greatly reduce the computational complexity compared to the joint detection scheme. In addition, the non-coherent combining detection scheme shows better performance under the additive white Gaussian noise (AWGN), fixed, and mobile environments.

Mastitis Detection by Near-infrared Spectra of Cows Milk and SIMCA Classification Method

  • Tsenkova, R.;Atanassova, S.
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1248-1248
    • /
    • 2001
  • Mastitis is a major problem for the global dairy industry and causes substantial economic losses from decreasing milk production and considerable compositional changes in milk, reducing milk quality. The potential of near infrared (NIR) spectroscopy in the region from 1100 to 2500nm and chemometric method for classification to detect milk from mastitic cows was investigated. A total of 189 milk samples from 7 Holstein cows were collected for 27 days, consecutively, and analyzed for somatic cells (SCC). Three of the cows were healthy, and the rest had mastitis periods during the experiment. NIR transflectance milk spectra were obtained by the InfraAlyzer 500 spectrophotometer in the spectral range from 1100 to 2500nm. All samples were divided into calibration set and test set. Class variable was assigned for each sample as follow: healthy (class 1) and mastitic (class 2), based on milk SCC content. The classification of the samples was performed using soft independent modeling of class analogy (SIMCA) and different spectral data pretreatment. Two concentration of SCC - 200 000 cells/ml and 300 000 cells/ml, respectively, were used as thresholds fer separation of healthy and mastitis cows. The best detection accuracy was found for models, obtained using 200 000 cells/ml as threshold and smoothed absorbance data - 98.41% from samples in the calibration set and 87.30% from the samples in the independent test set were correctly classified. SIMCA results for classes, based on 300 000 cells/ml threshold, showed a little lower accuracy of classification. The analysis of changes in the loading of first PC factor for group of healthy milk and group of mastitic milk showed, that separation between classes was indirect and based on influence of mastitis on the milk components. The accuracy of mastitis detection by SIMCA method, based on NIR spectra of milk would allow health screening of cows and differentiation between healthy and mastitic milk samples. Having SIMCA models, mastitis detection would be possible by using only DIR spectra of milk, without any other analyses.

  • PDF

Effect of titanium and stainless steel posts in detection of vertical root fractures using NewTom VG cone beam computed tomography system

  • Mohammadpour, Mahdis;Bakhshalian, Neema;Shahab, Shahriar;Sadeghi, Shaya;Ataee, Mona;Sarikhani, Soodeh
    • Imaging Science in Dentistry
    • /
    • v.44 no.2
    • /
    • pp.89-94
    • /
    • 2014
  • Purpose: Vertical root fracture (VRF) is a common complication in endodontically treated teeth. Considering the poor prognosis of VRF, a reliable and valid detection method is necessary. Cone beam computed tomography (CBCT) has been reported to be a reliable tool for the detection of VRF; however, the presence of metallic intracanal posts can decrease the diagnostic values of CBCT systems. This study evaluated and compared the effects of intracanal stainless steel or titanium posts on the sensitivity, specificity, and accuracy of VRF detection using a NewTom VG CBCT system. Materials and Methods: Eighty extracted single-rooted teeth were selected and sectioned at the cemento-enamel junction. The roots were divided into two groups of 40. Root fracture was induced in the test group by using an Instron machine, while the control group was kept intact. Roots were randomly embedded in acrylic blocks and radiographed with the NewTom VG, both with titanium and stainless steel posts and also without posts. Sensitivity, specificity, and accuracy values were calculated as compared to the gold standard. Results: The sensitivity, specificity, and accuracy of VRF diagnosis were significantly lower in teeth with stainless steel and titanium posts than in those without posts. Interobserver agreement was the highest in teeth without posts, followed by stainless steel posts, and then titanium posts. Conclusion: Intracanal posts significantly decreased the VRF diagnostic values of CBCT. The stainless steel posts decreased the diagnostic values more than the titanium posts.

Clinical Evaluation of Tumor Markers for Diagnosis in Patients with Non-small Cell Lung Cancer in China

  • Ma, Li;Xie, Xiao-Wei;Wang, Hai-Yan;Ma, Ling-Yun;Wen, Zhong-Guang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.12
    • /
    • pp.4891-4894
    • /
    • 2015
  • Background: To evaluate the value of combined detection of serum carcinoembryonic antigen (CEA), cytokeratin 19 fragment (CYFRA21-1), and carbohydrateantigen 125 (CA125) for the clinical diagnosis of nonsmall cell lung cancer (NSCLC). Materials and Methods: Serum CEA, CYFRA21-1 and CA125 were assessed in 140 patients with NSCLC, 90 patients with benign lung disease and 90 normal control subjects, and differences of expression were compared in each group, and joint effects of these tumor markers in the diagnosis of NSCLC were analyzed. Results: Serum CEA, CYFRA21-1 and CA125 in patients with NSCLC were significantly higher than those with benign lung disease and normal controls (P<0.05). The sensitivity of CEA, CYFRA21-1 and CA125 were 49.45%, 59.67%, and 44.87% respectively. As expected, combinations of these tumor markers improved their sensitivity for NSCLC. The combined detection of CEA + CYFRA21-1 was the most cost-effective combination which had higher sensitivity and specificity in NSCLC. Elevation of serum CEA and CYFRA21-1 was significantly associated with pathological types (P<0.05) and elevation of serum CEA, CYFRA21-1 and CA125 was significantly associated with TNM staging (P<0.05). Conclusions: Single measurement of CEA, CYFRA21-1 and CA125 is of diagnostic value in the diagnosis of lung cancer, and a joint detection of these three tumor markers, could greatly improve the sensitivity of diagnosis on NSCLC. Combined detection of CEA + CYFRA21-1 proved to be the most economic and practical strategy in diagnosis of NSCLC, which can be used to screen the high-risk group.

Clinical Features and Role of Viral Isolates from Stool Samples of Intussuception in Children

  • Lee, Yong Wook;Yang, Soo In;Kim, Ji Myoung;Kim, Jae Young
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.16 no.3
    • /
    • pp.162-170
    • /
    • 2013
  • Purpose: To detect major acute gastroenteritis virus (rotavirus, norovirus, astrovirus, and enteric adenovirus) and non-enteric type of adenovirus (AdV) in the stools of intussusception patients and to investigate the clinical role of detected viruses. Methods: From March 2012 to February 2013, major acute gastroenteritis virus and non-enteric type of AdV were isolated from stool samples that collected from 44 patients treated for intussusception in Chungnam National University Hospital. Patients were divided according to age and isolated virus. Results: Virus was detected in 28 (63%) stool specimens. The virus detection rate was significantly lower in patients aged under 12 months (p = 0.04). Twenty-two patients (78.6%) had non-enteric adenovirus, 4 (14.3%) had norovirus, 1 (3.6%) had sapovirus, and 1 (3.6%) had astrovirus. AdV subgroup C (AdV 1, 2, 5, and 6) comprised the majority with 20 cases (90.9%). A monthly increment-and-decrement pattern of intussusception was similar to that of viral detection in the stool samples. Enema reductions were successful in 39 patients and surgical manual reductions were performed in 5 patients. Virus was detected in 24 patients (61.5%) of enema reduction group and 4 patients (80.0%) of surgical manual reduction group. All of the detected viruses were non-enteric adenovirus subgroup C (AdV 1, 5, and 6) in surgical reduction patients. Conclusions: The virus detection rate was high in the stools of intussusception patients. The pattern of seasonal intussusception occurrence rate was parallel with seasonal these viral detection rate in the stool samples. These findings suggest that viral infection plays an important role in the development of intussusception and further research is warranted.

Trends in Development of Affinity Bioreceptor-based Biosensor for Rapid Detection of Marine Biotoxins (해양생물독소의 신속 검출을 위한 친화성 바이오리셉터 기반 바이오센서 개발 동향)

  • Chae Hwan Cho;Tae Jung Park;Jong Pil Park
    • Journal of Food Hygiene and Safety
    • /
    • v.39 no.5
    • /
    • pp.378-389
    • /
    • 2024
  • Marine biotoxins are becoming increasingly prevalent due to rising ocean temperatures driven by global warming, posing serious threats to food safety and public health. Traditional detection methods for marine biotoxins, such as mouse bioassays, high-performance liquid chromatography, and liquid chromatography-mass spectrometry, are limited by time-consuming procedures and high costs. Biosensor technology has emerged as a promising alternative. These biosensors employ bioreceptors (such as cells, antibodies, aptamers, and peptides) to detect marine biotoxins rapidly and accurately. In this review, we discuss the various types of bioreceptors and explore recent developments in biosensor technologies for marine biotoxin detection. Furthermore, we highlight the advantages of these bioreceptors and consider future directions for improving biosensor performance in detecting marine biotoxins.

Revalidation of the Complex Trial Protocol using participant-oriented countermeasures (설문 기반 대응방안을 사용한 복합시행 프로토콜의 재평가)

  • Kim, Hyemin;Song, Inuk;Chang, Eunhee;Kim, Hyun Taek
    • Korean Journal of Forensic Psychology
    • /
    • v.11 no.1
    • /
    • pp.89-115
    • /
    • 2020
  • Traditional deception detection methods had examined the difference of one's autonomic physiological responses through asking crime-related and crime-unrelated questions. There has been a continuing controversy regarding the accuracy and validity of the test, and thus, many researchers were motivated to explore and develop alternative efficient methods of detection in which one of them is known as P300-based Complex Trial Protocol (CTP). The P300-based CTP detects deception through comparing the P300 amplitudes between probe and irrelevant stimuli and is known as a counterstrategy of countermeasures. However, many previous studies have used countermeasures created from Rosenfeld et al.'s work (2008). The present study initially conducted a survey asking open-ended questions about the countermeasure use to acquire participant-oriented countermeasures for the main experiment. Then, the study aimed to evaluate whether the CTP can accurately detect deception even in the use of survey-based countermeasures. We firstly selected a set of participant-oriented countermeasures through survey questions. Then, a total of 50 participants were divided into three groups (innocent, guilty, and countermeasures) and performed the CTP. Those assigned to the countermeasures group covertly performed mental countermeasures during the CTP. The results of P300 amplitude analysis revealed that the guilty group's P300 amplitude of probe stimuli was significantly larger than that of irrelevant stimuli. Countermeasures group also had a significantly larger P300 amplitude for probe stimuli compared to irrelevant stimuli, even in the use of countermeasures. The results of bootstrapped amplitude difference (BAD) showed a detection accuracy rate of 81.25%, 82.35%, 82.35% for the innocent, guilty, and countermeasures groups, respectively. These findings demonstrate that the CTP can obtain a high detection rate in participant-oriented countermeasures and suggest the potential use of the CTP in the field.

  • PDF