• Title/Summary/Keyword: groundwater treatment

Search Result 472, Processing Time 0.025 seconds

Sequential Anoxic/Aerobic Biofilm Reactors and MF Membrane System for the Removal of Perchlorate and Nitrate (무산소/호기생물막반응조와 MF막의 연속처리에 의한 퍼클로레이트와 질산염 제거)

  • Choi, Hyeoksun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.5
    • /
    • pp.301-306
    • /
    • 2013
  • This research was conducted to investigate whether sequential anoxic/aerobic biofilm reactors and microfilteration (MF) membrane system can be used as a direct treatment for the removal of perchlorate and nitrate in groundwater. The biofilm process consisted of an anoxic first stage to remove perchlorate and nitrate and aerobic second stage to remove remaining acetate used as a carbon source for dissimilatory reduction of perchlorate and nitrate. In final stage, hollow fiber MF membrane was used to remove turbidity. In this research, perchlorate was reduced from the influent concentration of 102 ${\mu}/L$ to below the IC detection level (5 ${\mu}/L$) and nitrate was reduced from 61.8 mg/L (14 mg/L $NO_3$-N) to 4.4 mg/L (1 mg/L $NO_3$-N). Acetate used as a carbon source was consumed from 179 mg/L $CH_3COO-$ to 117 and 11 mg/L $CH_3COO^-$ in effluents from anoxic and aerobic biofilm reactors, respectively. Turbidity was reduced from 3.0 NTU to 1.5, 0.3, and 0.2 NTU in effluents from anoxic/aerobic biofilm reactors and MF membrane, respectively. It is expected that the sequential anoxic/aerobic biofilm reactors and MF membrane system can efficiently remove perchlorate and nitrate in surface water or groundwater.

Investigation on the Contamination of the Vicinity of Abandoned Coal Mines Located Near the Obong Darn and Preventive Measures (오봉댐 유역의 폐탄광에 의한 오염특성과 감소방안 연구)

  • Park, Sun Hwan;Chang, Yoon Young;Jeong, Jeong Ho;Son, Jeong Ho;Park, Seok Hyo
    • Journal of Environmental Impact Assessment
    • /
    • v.16 no.2
    • /
    • pp.143-156
    • /
    • 2007
  • This study has researched the management status and the pollution level of water, soil, stream sediments of 11 abandoned coal mines out of a total of 12 within Obong-Dam area except Bukyung mine, which was submerged when constructing Obong-Dam, and selected areas which are in needs to have pollution control facilities in the first place. From the results of examination on the runoff at the waste rock pile and mineheads, the runoff from Sueun mine (pH, Fe, Al), Samwon mine (pH, Al), Wangdo mine (pH, Al), Mose mine (pH, Fe, Al) and Daeryeong mine (pH) exceeded the permissible discharge standards of the water quality, but the water at merging point with Obong-Dam after joined with Doma branch satisfied both Water Quality Standards and Drinking Water Quality Standards. In regard to groundwater contamination, it is found that areas where exceeded the Drinking Water Quality Standards are Wangdo mine (pH), Jangjae mine (pH, Zn), Daeryeong mine (pH) whereas all areas satisfied Soil Contamination Warning Standards of Soil Environmental Conservation Law. When comparing a research result on underwater sediments of branches of abandoned mines to the EPA Guidelines for classification of great lakes harbor sediments, Dongguk Gaerim (Fe), Jungwon mine (Fe), Daebo mine (Mn), Samwon mine (Mn) and Daeryeong mine (Mn) showed mid-level of contamination, whereas Sueun (Fe, Mn), Daebo mine (Fe), Woosung mine (Fe, Mn), Wangdo mine (Fe, Mn), Mose mine (Fe) and Daeryeong mine (Fe) showed high-level of contamination. In addition, contamination levels of underwater sediments in Wangsan and Doma branch where abandoned mine's branches merge together, Wangsan branch showed no contamination at all whereas Doma branch shows mid-level of contamination which reflect the Doma branch is affected by waste rock pile and minehead runoff of the abandoned mines in the Doma branch area. It is concluded that Mose mine and Sueun mine required treatment of acid mine drainage. and Wangdo, Jungwon, and Samwon mines were in need of mine tailing and erosion control work. The Samwon mine additionally required a control system for closed minehead runoff. Although the Samwon mine reached a high concentration of Al, Mn $Ca^{2+}$, $SO{_4}^{2-}$ in the runoff, the levels decreased after it was combined with a tributary. It has been concluded that after further monitoring of the cause of pollution, a preventive measure system may be needed to be built.

Development and performance verification of induced drainage method for leakage treatment in existing underground structures (운영중인 지하구조물 누수처리를 위한 유도배수공법 개발 및 성능 검증)

  • Kim, Dong-Gyou;Yim, Min-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.3
    • /
    • pp.533-549
    • /
    • 2017
  • In this study, drainage systems were proposed to drain the leakage of groundwater in the existing underground concrete structures. The system consists of drainage board, wire mesh, fixed nail, and mortar with mineral. In order to increase constructability, the drainage board and wire mesh were attached on the surface of cement concrete using the air nailer and fixed nail. The mortar with 30% of blast furnace slag was sprayed on the drainage board and wire mesh using the spray mortar equipment. The field test construction was carried out in a conventional concrete lining tunnel and concrete retaining wall for performance verification of the drainage system in the field. There was no problem with performance degradation in the drainage system for three years after construction. The bond strength tests were performed on the sprayed mortar at 14 days and about 3 years after field test construction. In case of attaching the wire mesh on the drainage board, the bond strengths of the sprayed mortar were 1.04 MPa at 14 days and 1.46 MPa about 3 years. In case of the drainage board without the wire mesh, the bond strengths of the sprayed mortar were 1.13 MPa at 14 days and 0.89 MPa, less than 1 MPa of bond strength criteria, about 3 years.

Development of Low Temperature Thermal Desorption System and Remediation of Soil Contaminated with Petroleum Hydrocarbon (열순환식 저온열탈착 정화장치의 개발 및 유류오염 토양 현장 적용)

  • Kim, Guk-Jin;Lee, Sun-Hwa;Park, Kwang-Jin;Kim, Chi-Kyung;Lee, Cheol-Hyo;Kim, Do-Sun;Cho, Seok-Hee;Chang, Youn-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.13 no.4
    • /
    • pp.62-68
    • /
    • 2008
  • The Low Temperature Thermal Desorption (LTTD) System equipped with a soil transfer unit, a rotary kiln, RTO, cyclones and a bag filter etc. was developed. The LTTD system was designed to be economically operated using LPG as a fuel and recirculating the discharged gas from the LTTD system through RTO. For the performance test of LTTD system the soil contaminated with light and heavy oils (2,690 mg TPH/kg soil) and with particle sizes below 50 mm was fed into the rotary kiln of LTTD system at 7$m^3$/hr with retention time of 15 minutes. Operation temperatures of LTTD system for the removal of soil TPH were $567^{\circ}C$ and $692^{\circ}C$. The residual TPH after treatment was 46 mg/kg and 32mg/kg respectively at each temperature condition, which shows high TPH removal efficiencies of the developed LTTD as 98.3% and 98.9%.

제강분진을 이용한 침출수의 화학적 산화처리

  • 장윤영;강정우;정재현;배범한;박규홍;장윤석
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2001.04a
    • /
    • pp.107-110
    • /
    • 2001
  • 제철소에서 매년 대량 발생되어 주로 매립처분되고 있는 제강분진의 재활용 방안으로서, 폐수처리분야에 널리 사용되고 있는 펜톤산화공정의 반응촉매원인 Fe 공급원으로서 제강분 진의 활용 가능성에 대한 연구를 수행하였다. 본 연구에서는 포항제철소에서 제철부산물로 발생되는 제강분진을 전처리 없이 산화촉매로 사용하여 김포 수도권 매립지의 침출수 처리 공정에서 펜톤산화조에 유입되는 원수를 대상으로 과산화수소에 의한 산화처리 실험을 수행하였다. 반응은 회분식으로 수행하였으며, 일반적으로 알려진 펜톤산화반응의 주요 반응조 건인 운전 pH, 과산화수소 주입량 및 분할주입, 제강분진의 주입량 등의 변화에 따른 각 조 건별 시간에 따른 반응결과를 알아보았다. 또한 기존의 Fe 공급원으로 사용되고 있는 FeSO$_4$와 처리성능 및 적용조건에 대한 비교 실험도 수행하였다. 침출수 수질변화는 TOC (Total Organic Carbon) analyzer를 사용하여 측정한 TOC값으로 나타냈으며, pH controller 와 정량펌프를 사용하여 HCl과 NaOH주입을 통해 반응기간동안 일정 pH를 유지하였다. 본 연구결과, 최적 pH 조건인 4에서 최대 75% TOC 제거율을 나타내었으며, 대부분의 반응은 30분 이내에 이루어졌다. 주어진 실험조건에서 FeSO$_4$와 비교하여 반응속도와 처리효율에서 향상된 결과를 나타내었으며 반응 후 응집침전실험에서도 보다 높은 처리효과를 얻을 수 있었다. 결론적으로, 과산화수소/제강분진 시스템을 이용한 화학적 산화처리방법은 경제성과 처리성능에서 기존의 펜톤산화공정의 대체방안으로서 향 후 적용가능성이 높을 것으로 기대된다.g, 200 mg/kg, 300 mg/kg의 순서로 함량이 점차 감소하는 결과를 얻을 수 있었다. 이상의 결과를 종합하여 볼 때 가자 메탄올추출물은 PQ 유도독성을 신장 및 폐조직에서 효과적으로 경감시키는 것으로 나타났다.ted retailers ("sellers") must accept end-of-life items returned to them by the consumers. At the local level, Taipei City implements a pay-as-you-throw program, whereby citizens pay waste collection and treatment fees through the purchase of special trash bags approved by the Taipei City Government. However. recyclables that are separated by citizens are collected free-of-charge by the City. Taichung City and Kaohsiung City, on the other hand, enforce mandatory sorting schemes, whereby citizens face penalties if they don't separate recyclables from the trash before pick-up. These programs have resulted in a significant reduction in municipal waste. Per capita waste collected per day has dropped from 1.143

  • PDF

Assessment for the Comparability between Korean Ministry of Environment Standard and ISO Standard for the Determination of Heavy Metals in Soil (토양 중금속 함량 측정에 대한 토양오염공정시험기준과 국제표준간의 적합성 평가)

  • Shin, Gun-Hwan;Lee, Goon-Teak;Lee, Won-Seok;Kim, Ji-In;Kim, Bo-Kyong;Park, Hyun-Jeong
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.3
    • /
    • pp.1-9
    • /
    • 2012
  • According to the agreement on WTO/TBT, we are under the situation to adopt international standard (ISO standard) as a national standard if it exists. However, in case of environmental area, it is a domestic legal obligation to use Korean environmental standard method(KESM) for analyzing various contaminants. Therefore it is necessary to assess the comparability between KEM and ISO standard prior to apply ISO standard to soil conservation law in Korea. The main purpose of this study is to assess the comparability of both methods for analyzing heavy metals in soil. We looked over various aspects like pre-treatment, calibration curve range, detection wavelength, soil organic matter content and so on. Apparently, the procedure of both methods is almost same. However in details, both methods are different in stationary time before aqua-regia extraction using reflux system, calibration curve range for Cu, Pb, Ni and measuring wavelength for Pb. According to the results of comparison test, the results were significantly different when the different calibration range was used. In case that all the extracts independent of methods were reanalyzed with the same calibration range of each method, both methods showed statistically same results. Other conditions like different stationary time, measuring wavelength of AAS and soil organic matter content did not have any influence on the analytical result. Therefore, we suggest to extend the calibration curve range to 0~8 mg/L which is used in KS I ISO standard(Korean standard related with environment which is translation version of ISO standard without any technical change). In case of $Cr^{6+}$, the results showed no significant differences between two methods even though the pretreatment, instrumentation and other analysis conditions were different. In addition to UV/Visble spectrometry of KESM for soil contamination, we suggest to adopt ion chromatography of ISO 15192(US EPA method 7199) for analyzing $Cr^{6+}$ with the consideration of laboratory work efficiency.

Experiment of Reactive Media Selection for the Permeable Reactive Barrier Treating Groundwater contaminated by Acid Mine Drainage (산성광산배수로 오염된 지하수 정화용 투수성 반응벽체 반응매질 선정 기초실험)

  • Ji Sang Woo;Cheong Young Wook
    • Economic and Environmental Geology
    • /
    • v.38 no.3 s.172
    • /
    • pp.237-245
    • /
    • 2005
  • The batch tests were performed to evaluate the applicability of the permeable reactive barrier (PRB) to in-situ treatment of groundwater with high concentration of heavy metals. The lead\chates used in this study were collected from waste rock dump of the Imgy mine, and have a low pH and high metal concentration. The acidity loading was 65kg as $CaCO_3/day$, metal loading of Fe+Al+Mn was 11.6kg/day. This type of water could be treated with biological-mediated sulfate reduction using the organic carbon mixture as a reactive media. The batch tests were carried out with five mixtures that were composed with different mixing ratios of mushroom compost, pine-tree bark, and limestone cheep. Results indicated that the PRB could reduce the acidity loading $CaCO_3/day$ to 12.3kg and reduce the metal loading to 3.3kg/day. Considering about the low pH and high metal loading, the contaminated water may be ameliorated by passing it through the buffering PRB composed with inorganic carbonate materials and then through the PRB composed with the organic carbon mixture which can induce sulfate reduction.

A Role of Dissolved Iron ion in Combined Fenton Reaction for Treatment of TNT Contaminated Soil (오염토양처리를 위한 혼합 Fenton 공정에서 용존 철이온이 오염산화처리에 미치는 역할에 관한 연구)

  • Seo, Seung-Won;Kong, Sung-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.6
    • /
    • pp.76-82
    • /
    • 2006
  • Fenton's reaction are difficult to apply in the field due to the low pH requirements for the reaction and the loss of reactivity caused by the precipitation of iron (II) at neutral pH. Moreover, Fenton-like reactions using iron mineral instead of injection of iron ion as a catalyst are operated to get high removal result at low pH. Because hydroxyl radical can generate at the surface of iron mineral, there are competition with a lot of hydroxide at around neutral pH. On the other side, to operate Fenton's reaction series at neutral pH, modified Fenton reaction is suggested. The complexes, composed by iron ions (ferrous ion or ferric ion)-chelating agent, could be acted as a catalyst and presented in the solution at neutral pH. However, modified Fenton reaction requires a lot of hydrogen peroxide. Accordingly, the purpose of this experiment was to effectively combine Fenton-like reaction and modified Fenton reaction for extending application of Fenton's reaction. i.e., injecting chelating agents in Fenton-like reaction at around neutral pH is increasing the concentration of dissolved iron ion and highly promoting the oxidation effect. 2,4,6-trinitrotoluene (TNT) was used as a probe compound for comparing reaction efficiencies in this study. If the concentration of dissolved iron ion in combined Fenton process were existed more than 0.1 mM, the total TNT removal were increased. Magnetite-NTA system showed the best TNT removal (76%) and Magnetite-EDTA system indicated about 56% of TNT removal. The results of these experiments proved more promoted 40-60% of TNT removal than Fenton-like reaction's.

A Study of Efficient Removal of 2-Methylisoborneol and Geosmin by Pulsed Ultraviolet and Ultrasound (효율적인 2-Methylisoborneol, Geosmin의 제거를 위한 Pulsed UV 공정과 Ultrasound 공정의 비교 연구)

  • Han, Jonghun;Hur, Jiyong;Kim, Kangwook;Lee, Junyoung;Park, Wonseok;Lee, Jongyeol;Her, Namguk
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.4
    • /
    • pp.1-7
    • /
    • 2015
  • The degradation of off-flavors which is 2-Methylisoborneol (2-MIB) and geosmin by means of ultrasound (US) and pulsed ultraviolet (PUV) irradiation and its combination with catalyst (wire mesh, wire mesh coated TiO2, and TiO2) and additive (H2O2) were investigated via water system. A combination treatment of TiO2 and H2O2 heterogeneity with US (24 kHz) and PUV (6000 W) has shown improved results in destroying 2-MIB and geosmin, which may be attributed to chain reactions by the enhanced formation of hydroxyl radicals (·OH) through H2O2 dissociation and reactive oxide ions of TiO2 addition. Rapid degradation of off-flavors occurred within 2 min under PUV process with H2O2 100 mg/L (81.5% for 2- MIB; 79.3% for geosmin) and TiO2 100 mg/L (83.7% for 2-MIB; 79.8% for geosmin), while compared with H2O2 100 mg/L (58.4% for 2-MIB; 58.0% for geosmin) and TiO2 100 mg/L (59.2% for 2-MIB; 38.5% for geosmin) within 5 min under US process. Surprisingly, the emphasis was given on the comparison with the same injected energies between PUV and US on degradation efficiency. Based on the injected energy comparison, the US provided better degradation performance under equal input power of 200 kJ with H2O2 100 mg/L, while compared with H2O2 100 mg/L under PUV process. Our findings suggest that US can be more effective compared to PUV for the degradation of off-flavors in aspect of energy consumptions.

Scientific Feasibility on the Risk-Based Clean-up and Management of Contaminated Sites ("위해성" 개념을 이용한 오염지역 정화 및 관리의 과학적 타당성)

  • Shin, Won-Sik
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.1
    • /
    • pp.1-35
    • /
    • 2007
  • In the last decades, the decrease in biological or chemical availability of sorbed contaminants as contact time passed, is generally accepted. This phenomenon so called as "aging" or "sequestration" is known to directly affect risk of the contaminats. This was observed for mainly for hydrophobic organic contaminants (HOCs), but also reported for heavy metals. Aging is known to be directly related to sorption-desorption hysteresis, irreversible sorption, desorption-resistance, nonequilibrium sorption, etc. The decrease in bioavailability due to aging or sequestration indicates realistic decrease in risk potential. Recently a risk-based management concept by scientific evidences but not the simple measurement of contaminant concentration has been attempted to determine environmentally acceptable remedial endpoint. This is because selection of remedial endpoint based on not total concentration but the bioavailability and toxicity of contaminants can reduce both the treatment cost and remedial activities of the contaminated sites. The bioavailability and toxicity of the residual contaminants are highly affected by the fate and transport and also directly affect the exposure pathways and bioaccumulation of contaminants in the living biota. In this paper, scientific feasibility on the risk-based clean-up and management of contaminated sites is reviewed.