• Title/Summary/Keyword: groundwater sampling

Search Result 143, Processing Time 0.025 seconds

CFCs 조사를 위한 지하수 시료채취방법 비교 및 평가

  • 고동찬;이대하;성현정;강철희;고경석
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.21-23
    • /
    • 2002
  • Two sampling methods for chlorofluorocarbons(CFCs) in groundwater were compared and assessed with groundwater samples in Jeju Island. CFCs concentrations from copper tube method were widely variable among triplicates and higher than those from flame-sealed glass ampule method. For the copper tube method, this is aggravated by rubber packings in the faucet of discharge line of wells, which was removed for the glass ampule method. The poor reproducibility and apparent contamination of results by copper tube method is due to the improper sealing of copper tubes and materials in water discharge line. This suggests that it is more difficult to achieve complete isolation from the atmosphere in the copper tube method and that materials that could release CFCs should be avoided along the sampling flow lines. It seems that the flame-sealed glass ampule method is more relevant for groundwater sampling for CFCs though it requires more complicated equipments and procedures.

  • PDF

Investigation and Assesment of Ground Contamination around Waste Landfill (폐기물매립지 주변 토양 및 지하수 오염도 조사 및 분석)

  • 정하익;김상근
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.05a
    • /
    • pp.116-119
    • /
    • 2000
  • There has been a steady increase in geoenvironmental engineering projects where geotechnical engineering has been combined with environmental concerns. Many of these projects involve some investigation on contaminant and leachate flume in the ground and landfill. In this study, investigation and assesment on soil and groundwater around the waste landfill was carried out. Many techniques such as drilling and sampling method were applied. As a result of this study, the concentration of soil and groundwater were investigated and analysed.

  • PDF

Introduction to the Strategic Sampling Approaches to Construct Optimal Conceptual Model of a Contaminated Site (오염부지 최적 개념모델 수립을 위한 전략적 샘플링 기법 소개)

  • Park, Hyun Ji;Kim, Han-Suk;Yun, Seong-Taek;Jo, Ho Young;Kwon, Man Jae
    • Journal of Soil and Groundwater Environment
    • /
    • v.25 no.2_spc
    • /
    • pp.28-54
    • /
    • 2020
  • Even though a systematic sampling approach is very crucial in both the general and detailed investigation phases to produce the best conceptual site model for contaminated sites, the concept is not yet established in South Korea. The U.S. Environmental Protection Agency (EPA) issued the 'Strategic Sampling Approaches Technical guide' in 2018 to help environmental professionals choose which sampling approaches may be needed and most effective for given site conditions. The EPA guide broadly defines strategic sampling as the application of focused data collection across targeted areas of the conceptual site model (CSM) to provide the appropriate amount and type of information needed for decision-making. These strategic sampling approaches can prevent the essential data from missing, minimize the uncertainty of projects and secure the data which are necessary for the important site-decisions. Furthermore, these provide collaborative data sets through the life cycle phases of projects, which can generate more positive proofs on the site-decisions. The strategic sampling approaches can be divided by site conditions. This technical guide categorized it into eight conditions; High-resolution site characterization in unconsolidated environments, High-resolution site characterization in fractured sedimentary rock environments, Incremental sampling, Contaminant source definition, Passive groundwater sampling, Passive sampling for surface water and sediment, Groundwater to surface water interaction, and Vapor intrusion. This commentary paper introduces specific sampling methods based on site conditions when the strategic sampling approaches are applied.

지하수 조사에서 환경추적자로서의 $SF_6$의 적용

  • ;Niel Plummer;Eurybiades Busenberg
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.73-76
    • /
    • 2003
  • SF$_{6}$ (Sulfur Hexafluoride) is a gaseous compound whose use is being greatly increased recently. The compound has a negligible background concentration from natural sources and is stable in most of groundwater environments. Therefore, SF$_{6}$ has potential for a dating tool for young groundwater. It has many advantages over chlorofluorocarbons (CFCs) for groundwater investigation that sampling procedure is much simpler than CFCs and its growth is continued up to at least near future in the atmosphere. However, solubility of SF$^{6}$ is so low that excess air causes large uncertainties in recharge date of groundwater. To compensate the limitation, $N_2$/Ar method can be employed to estimate excess air content. A groundwater study is currently carrying out in Jeju Island using SF$_{6}$ as an environmental tracer, Well waters and spring waters were sampled for SF$_{6}$ and $N_2$/Ar. To establish SF$_{6}$ input history in the study area, air sampling is being conducted in the area near the center of the island on a monthly and weekly basis. Based on the present data, the level of SF$_{6}$ concentration in the atmosphere of the Island is corresponding to the trend of the Northern Hemisphere.

  • PDF

Fluorescence Characteristic Spectra of Domestic Fuel Products through Laser Induced Fluorescence Detection

  • Wu, Ting-Nien;Chang, Shui-Ping;Tsai, Wen-Hsien;Lin, Cian-Yi
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.5
    • /
    • pp.18-25
    • /
    • 2014
  • Traditional investigation procedures of soil and groundwater contamination are followed by soil gas sampling, soil sampling, groundwater sampling, establishment of monitoring wells, and groundwater monitoring. It often takes several weeks to obtain the analysis reports, and sometimes, it needs supplemental sampling and analysis to delineate the polluted area. Laser induced fluorescence (LIF) system is designed for the detection of free-phase petroleum pollutants, and it is suitable for on-site real-time site investigation when coupling with a direct push testing tool. Petroleum products always contain polycyclic aromatic hydrocarbon (PAH) compounds possessing fluorescence characteristics that make them detectable through LIF detection. In this study, LIF spectroscopy of 5 major fuel products was conducted to establish the databank of LIF fluorescence characteristic spectra, including gasoline, diesel, jet fuel, marine fuel and low-sulfur fuel. Multivariate statistical tools were also applied to distinguish LIF fluorescence characteristic spectra among the mixtures of selected fuel products. This study successfully demonstrated the feasibility of identifying fuel species based on LIF characteristic fluorescence spectra, also LIF seemed to be uncovered its powerful ability of tracing underground petroleum leakages.

Quantification of Uncertainty Associated with Soil Sampling and Its Reduction Approaches (토양오염도 평가시 시료채취 불확실성 정량화 및 저감방안)

  • Kim, Geonha
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.1
    • /
    • pp.94-101
    • /
    • 2013
  • It is well known that uncertainty associated with soil sampling is bigger than that with analysis. In this research, uncertainties for soil sampling when assessing TPH and BTEX concentration in soils were quantified based on actual field data. It is almost impossible to assess exact contamination of the site regardless how carefully devised for sampling. Uncertainties associated with sample reduction for further chemical analysis were quantified approximately 10 times larger than those associated with core sampling on site. Bigger uncertainties occur when contamination level is low, sample quantity is small, and soil particle is coarse. To minimize the uncertainties on field, homogenization of soil sample is necessary and its procedures are proposed in this research as well.

국가지하수 관측소의 장기수위관측자료를 활용한 관측주기 결정 연구

  • 김규범;김정우;원종호;이명재;이진용;이강근
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.199-201
    • /
    • 2003
  • The monitoring effectiveness not only depends on the effectiveness of the network, but also the costs of the network. Generally the costs of the monitoring network are mainly on the equipment and personnel; the implementation and maintenance; the observation and sample connection; the sample analysis; and the data storage and processing. The cost of the monitoring network can be expressed as a function of monitoring frequency because the monitoring method can be an automatic or a manual measurement. To determine the sampling frequency of subsidiary groundwater monitoring stations, time series data of national groundwater monitoring stations were used. The proposed optimal sampling frequency for subsidiary groundwater monitoring station is about 7 to 20 days and the average frequency is about 2 weeks.

  • PDF

Groundwater Monitoring Network Design by Employing CPT Rig and BAT Sampling Techniques

  • ;David Lockington;William Clarke
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.06a
    • /
    • pp.79-83
    • /
    • 1998
  • This study was conducted to delineate plume occurred in hazardous waste disposal site. At first, CPT (Cone Penetrometer Test) rig and HydroPunch were used to collect depth-discrete groundwater samples in concerned area. However, it was not capable of sampling the groundwater due to the cone refusal where the residual clay are layered at nominal depth through the aquifer. Alternatively, a number of temporary wells were installed after each of locations was penetrated using a modified steel cone functioned by CPT rig. The samples taken from those of wells were characterized by GCMS and GCFID, which revealed that sulfolane and thiolane were mainly presented. Subsequent analyses performed for the samples taken from permanent nest piezometers consistently demonstrated that possible plume boundary can be presented in the study area where contaminants were found as low as detection limit or levels of not-detectable.

  • PDF

Determination of Soil Sample Size Based on Gy's Particulate Sampling Theory (Gy의 입자성 물질 시료채취이론에 근거한 토양 시료 채취량 결정)

  • Bae, Bum-Han
    • Journal of Soil and Groundwater Environment
    • /
    • v.16 no.6
    • /
    • pp.1-9
    • /
    • 2011
  • A bibliographical review of Gy sampling theory for particulate materials was conducted to provide readers with useful means to reduce errors in soil contamination investigation. According to the Gy theory, the errors caused by the heterogeneous nature of soil include; the fundamental error (FE) caused by physical and chemical constitutional heterogeneity, the grouping and segregation error (GE) aroused from gravitational force, long-range heterogeneous fluctuation error ($CE_2$), the periodic heterogeneity fluctuation error ($CE_3$), and the materialization error (ME) generated during physical process of sample treatment. However, the accurate estimation of $CE_2$ and $CE_3$ cannot be estimated easily and only increasing sampling locations can reduce the magnitude of the errors. In addition, incremental sampling is the only method to reduce GE while grab sampling should be avoided as it introduces uncertainty and errors to the sampling process. Correct preparation and operation of sampling tools are important factors in reducing the incremental delimitation error (DE) and extraction error (EE) which are resulted from physical processes in the sampling. Therefore, Gy sampling theory can be used efficiently in planning a strategy for soil investigations of non-volatile and non-reactive samples.