• 제목/요약/키워드: groundwater quality

검색결과 617건 처리시간 0.029초

전남 남부 도서갯벌 퇴적물의 유기물 및 미량금속 오염 평가 (Evaluation of Organic Matter and Trace Metal Contaminations of Intertidal Sediments from Coastal Islands in the Southern Region of Jeollanam Province)

  • 황동운;김평중
    • 한국수산과학회지
    • /
    • 제46권5호
    • /
    • pp.626-637
    • /
    • 2013
  • We measured the grain size, ignition loss (IL), chemical oxygen demand (COD), acid volatile sulfide (AVS) and trace metals (Al, Fe, Cu, Pb, Zn, Cd, Cr, Mn, Hg, and As) of intertidal surface sediment collected from 11 islands (62 stations) in the southern region of Jeollanam Province. The objective of this research was to evaluate the organic matter and trace metals contaminations of sediments from coastal island tidal flats. Surface sediment texture was characterized as follows: mud, sandy silt, muddy sand, and slightly gravelly sand facies. The finer sediments are mainly dominated in the northern part of each island. The concentrations of IL, COD, AVS and some trace metals (Al, Fe, Zn, Cr, Cu, and Hg) were higher in the northwestern part of Wan Island and the area between Gogeum and Sinji Islands, and were associated with relatively finer sediment, as compared to other locations. The concentrations of Mn, Pb, Cd, and As were higher in the northwestern and southeastern parts of Geoguem and Pyungil Islands, but were not correlated with mean grain size. Based on sediment quality guidelines (SQGs), the concentrations of trace metals were lower than the values of effect range low (ERL), used in United States, and threshold effects level (TEL), used in Korea, with exception of As. Similarly, the intertidal sediments were moderately contaminated with As, based on the the enrichment factor (EF) and the geoaccumulation index ($I_{geo}$). The high concentration of As in intertidal sediments from this study region may be due to the input of naturally or artificially contaminated submarine groundwater, contaminated waste from seaweed aquaculture operations and/or land-based seaweed processing facilities. Further studies are needed to identify the sources of As in this study region, and to determine the effects of As contamination on coastal ecosystem.

전기비저항탐사를 이용한 터널라이닝 누수조사 연구 (A Study on leakage monitoring of tunnel linings using the electric resistivity survey)

  • 신종호;신용석;윤종열;김호종
    • 한국터널지하공간학회 논문집
    • /
    • 제10권3호
    • /
    • pp.257-267
    • /
    • 2008
  • 우리나라에서 흔히 채택하고 있는 배수형 터널은 배수시스템 열화 혹은 수압작용에 따라 누수가 발생하는 문제점을 내포하고 있다. 누수는 소량일 경우 외관으로 드러나지 않아, 육안으로 확인할 단계가 되면 이미 라이닝 손상 혹은 설비에 영향을 미치는 상황이 되어 초기에 인지하고 대책을 마련하는 것이 매우 중요하다. 그러나 운영 중인 배수터널의 누수거동을 확인하기 위해서는 터널을 훼손하여 배면을 조사하여야 하는데, 이는 터널 유지관리상 허용되기 어렵다. 본 연구에서는 비파괴 물리탐사법인 전기비저항 탐사법을 이용하여 터널의 방수막을 훼손하지 않고, 누수여부를 파악하는 새로운 시도를 하였다. 모형 라이닝을 제작하여 습윤정도, 혹은 열화에 따른 누수거동을 탐사한 결과 전기비저항 탐사법이 라이팅 배수기능모니터링 혹은 누수조사에 유용하게 활용될 수 있음을 확인하였다. 또한 이 방법은 라이닝 누수 보수공사 후, 추가 누수여부의 조사 및 보수공사 점검에도 유용하게 활용될 수 있음을 보였다.

  • PDF

네덜란드의 토양환경정책 (Soil Environmental Policy in Netherlands)

  • 송창수
    • 한국토양환경학회지
    • /
    • 제2권2호
    • /
    • pp.3-8
    • /
    • 1997
  • 본 고에서는 네덜란드에서 시행하고 있는 토양환경정책에 대하여 정리하여 보았다. 네덜란드 토양환경관리목표는 토양의 다기능성의 유지 및 회복에 두고 있다. 네덜란드의 토양법체계는 토양보호법을 중심으로 환경관리법, 건축법 등을 통해 토양환경의 보전을 하고 있으며, 공장지대나 주유소는 토양보호법의 테두리 안에서 별도의 명령을 통해 관리되고 있다. 아울러 정화의 책임에 대하여 오염원인자부담원칙 및 정부부담의 원칙을 취하고 있는데, 1987년 이전에 대해서는 책임을 묻지 않는 방법을 취하고 있다. 정화의 책임순서로는 오염원인자, 소유자, 권리행사자 순으로 되어 있으며, 정화는 오염자 스스로 정화를 하도록 유도하고 그렇지 않을 경우에는 정부가 돈을 투자하여 정화를 행하고 있다. 아울러 건축물을 짓고자 할 경우에는 토양에 관한 조사를 하도록 하고 있으며, 토지를 사고 파는 과정에서는 반드시 토양의 질에 관한 정보를 확인하도록 행하고 있다.

  • PDF

국내폐탄광의 산성폐수 오염도 평가에 관한 연구 (A Study on the Assessment of the Contamination by Acid Mine Drainage in Abandoned Coal Mines)

  • 최우진
    • 한국토양환경학회지
    • /
    • 제2권3호
    • /
    • pp.31-38
    • /
    • 1997
  • 산성폐수에 함유된 오염물질의 물리적 화학적 특성이 배우 복잡하기 때문에 산성폐수에 의해 오염된 지표수나 지하수등의 오염정도를 지역적, 시간적 변화에 따라 비교하는 일은 쉽지가 않다. 본 논문에서는 산성폐수에 의해 오염된 지표수나 지하수의 오염도를 정량적으로 평가할 수 있는 수학적 지표를 제시하였으며, 오염지표를 이용하여 국내 폐탄광의 갱내 유출수에 대한 오염도를 검토하였다. 사용된 오염지표(Acid Mine Drainage Index)는 수질의 오염정도를 가장 잘 나타낼수 있는 7개의 변수 즉, pH값, 황산염(Sulfate), 철, 망간, 알루미늄, 구리 및 아연 함량을 이용하여 계산하였다. 사용된 변수는 오염도에 미치는 상대적인 중요도를 감안하여 가중치를 사용하였으며 , pH값 및 황산염함량에 가장 높은 가중치를 부여하였다. 국내 폐광산에서 유출되는 산성폐수의 오염도 평가결과 경북 문경에 소재한 석봉탄광이 조사탄광중 상대적으로 오염도가 높았으며, 지역적으로 영동지역에 위치한 폐탄광의 갱내 유출수가 영서, 중부, 서부 및 남부에 위치한 폐탄광에 비해 오염도가 높게 나타났다.

  • PDF

염수로 포화된 해안지역 대수층을 활용한 수자원확보 방안 (Subsurface Water Storage Using Coastal Aquifers Filled With Saline Water)

  • 정은태;박남식;김인철;이승휘
    • 한국해안·해양공학회논문집
    • /
    • 제27권5호
    • /
    • pp.353-357
    • /
    • 2015
  • 해수침투로 인하여 부존되어 있는 지하수의 염분농도가 높아 방치되고 있는 해안지역 대수층을 활용한 수자원 확보 방안을 제안하였다. 대수층으로 담수를 주입하여 염수를 치환할 수 있는 주입-양수 시스템을 연구하였다. 염수로 포화되어 있는 충적층에서 인공함양 및 회수 기술이 성공하기 위해서는 양수정으로 유입되는 염수를 방지하는 것이 가장 중요한 문제 중의 하나이다. 본 연구에서는 양수정을 염수 침투로부터 방지하기 위한 염수포획관정의 효과를 수치모델링 방법으로 분석하였다. 적절히 설계된 염수포획관정은 담수 양수정을 염수침입으로부터 보호할 수 있음을 제시하였다.

Benefit of the Drinking Water Supply System in Office Building by Rainwater Harvesting: A Demo Project in Hanoi, Vietnam

  • Dao, Anh-Dzung;Nguyen, Viet-Anh;Han, Mooyoung
    • Environmental Engineering Research
    • /
    • 제18권2호
    • /
    • pp.103-108
    • /
    • 2013
  • Vietnam is a developing country with the rate around 5%-6% per year, especially in urban areas. Rapidly developed urban areas lead to stress for infrastructure and the water supply is also stressed. In Hanoi city, total water capacity from the manufactories is around one million cubic meters per day and almost the entire main water source is groundwater but it is not enough to supply all of Hanoi's people, especially in the summer. A demo project is implemented in Hanoi University of Civil Engineering (HUCE) to produce drinking water by using the rainwater and membrane system and supply for people. In this project, rainwater is collected on the rooftop of the lecture building with an area of around $500m^2$ and $100m^3$ volumetric rainwater tanks. Afterwards, the rainwater is treated by the micro-membrane system and supplied to the tap water. Total cost for construction, technology and operation in the first year is around USD 48,558. In the long-term (15 yr) if HUCE invests in the same system, with $20m^3$ volumetric storage tank, it can provide drinking water for 500 staffs in every year. The cost of investment and operation for this system is lower than 30% compared to buying bottled water with the price USD 1.8/bottle. The drinking water parameters after treatment are pH, 7.3-7.75; turbidity, 0.6-0.8 NUT; total dissolved solids, 60-89 mg/L; coliform, 0; heavy metal similar with water quality in the bottle water in Vietnam.

Effects of Waste Nutrient Solution on Growth of Chinese Cabbage (Brassica campestris L.) in Korea

  • Choi, Bong-Su;Lee, Sang-Soo;Ok, Yong-Sik
    • 한국환경농학회지
    • /
    • 제30권2호
    • /
    • pp.125-131
    • /
    • 2011
  • BACKGROUND: Reuse of waste nutrient solution for the cultivation of crops could lead to considerable conservation of water resources, plant nutrients, and water quality. Therefore, this study was conducted to evaluate the potential for reducing the use of chemical fertilizer in Chinese cabbage cultivation via the reuse of waste nutrient solution as an alternative irrigation resource. METHODS AND RESULTS: The nutrients supplied in the waste nutrient solution consisted of 1474.5, 1285.1, 991.6, and 872.6 mg/L for $K+$, ${NO_3}^-$, $Ca^{2+}$ and ${SO_4}^{2-}$, respectively. At 56 days after transplanting (DAT), the leaf length of Chinese cabbage plants irrigated with the waste nutrient solution treatment was significantly higher than that of plants irrigated using a conventional groundwater treatment. Additionally, the leaf width, fresh weight and dry weight of the plants irrigated with the waste nutrient solution were similar or greater than that of plants irrigated with a conventional treatment. Furthermore, the growth of plants treated with the waste nutrient solution +25% fertilizer was the highest among all tested treatments. CONCLUSION(s): These results indicate that the waste nutrient solution can be used as an alternate water resource for crop cultivation. In addition, it can contribute to reduce the fertilizer and to obtain the higher crop yield of Chinese cabbage.

투수성 포장에 의한 비점오염원 저감 효과 분석 (Analysis of Non-point Pollution Source Reduction by Permeable Pavement)

  • 구영민;김영도;박재현
    • 한국수자원학회논문집
    • /
    • 제47권1호
    • /
    • pp.49-62
    • /
    • 2014
  • 최근에 불투수층의 증가로 인하여 표면의 저류량이 감소하고 첨두유출과 전체 유출량은 증가한다. 첨두유출과 첨두유출 도달시간이 빨라지게 되면 홍수 발생률이 증가하여 도시유역의 피해를 증가시키며, 토양으로 침투되는 우수량이 감소하여 지하수위가 하강하게 되고 도시하천이 마르는 건천화가 진행되어 유역의 물 순환이 악화된다. 또한 하천 수질 오염의 원인은 점오염원과 비점오염원 등이 있는데, 비점오염원에 의한 오염이 점점 커져가는 양상이다. 이러한 이유는 도시유역이 지속적인 개발로 인해 불투수율이 증가하게 되어 초기강우에 오염물질이 하천으로 유입되고 있기 때문이다. 따라서 본 연구에서는 도시유역의 물순환 회복을 위한 투수성 포장 효과를 분석하며, 투수성 포장의 비점저감 효과 및 첨두유량 감소 효과를 분석하고자 한다. 도시유역 유출 모델인 SWMM을 이용하여 단기 유출 모의를 통하여 투수성 포장의 효과 분석하였다.

지하수 수질관리를 위한 안심지하수 연구 (Study of securing safe groundwater for water quality management)

  • 이충모;함세영;전항탁;임우리
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2017년도 학술발표회
    • /
    • pp.454-454
    • /
    • 2017
  • 국내 상수도가 보급되지 않은 지역 내 취약 계층은 약 214만 명으로 대부분은 노후관정 및 미신고 관정에서 지하수를 먹는물로 이용하고 있다. 이들은 대부분 미신고 관정이기 때문에 실태파악이 어렵고 정기적인 수질 검사를 실시하지 않아 수질상태에 대한 안전 대책이 미흡한 실정이다. 우리나라의 경우 농촌지역의 관정은 천부지하수의 의존도가 크고 강우에 의한 지표오염물질(축산분뇨, 비료 등)이 관정 내부로 유입 가능성이 매우 높다. 기존 연구에서도 천부지하수 관정의 조사 결과, 질산성질소 및 총대장균군에 의한 수질 오염이 심각하다고 보고된다(Chae et al., 2004; Min et al., 2003). 따라서 상수도 미보급지역 지하수 관정의 지하수 수질 현황을 파악하고, 고농도 오염 관정 및 지역의 경우 정밀조사를 통해 오염 원인을 규명해야 한다. 또한 오염 원인에 대한 향후 개선방안 및 대책안을 마련하여 지하수 수질 안정성 확보를 도모할 필요가 있다. 이를 위해 환경부 산하 국립환경과학원에서는 안심지하수 지원 사업을 2012년 "지하수 안심이용 무료 수질검사 시범사업"부터 시작하여 2016년 "상수도 미보급지역 2016년 안심지하수 지원사업 연구"로 이어지며 수행하였다. 이 사업은 수질분석, 관정내부 탐사, 마을 공용 음용관정 설치지원, 고농도 오염지역 중 시범사업 지역 선정, 고농도 오염지역 수질개선 시범사업으로 구성된다. 수질 분석은 2012년 TA군 내 8개 읍 면의 1,200개 관정, 2013년 경기 북동부권 8개 시 군 11,861개 관정, 2014년 전국 14,494개 관정, 2015년 전국 25,900 관정, 2016년 전국 25,914 관정에 대해 수질 분석을 실시하였다. 수질분석 결과를 바탕으로 고농도 오염지역의 지하수 관정 내부 탐사를 실시하여 소유주에게 주변 환경 개선 조치 및 대민 지원(마을 공용 음용관정 설치)을 수행하고, 시범조사 대상지역을 선정하여 오염지역의 오염원 현황, 수질조사, 지하수 유동 모델링을 실시하여 오염 원인을 파악하였다. 추가로 2014년에는 안심지하수 수질보전 연구로드맵을 작성하여 환경부에 제시하였고, 2015년은 수질개선 사업에 대한 경제성 분석, 수질자료 DB 구축이 완료되었다.

  • PDF

Design, manufacture and field test of a surface water storage tank providing irrigation water to upland crops

  • Shin, Hyung Jin;Kim, Young-Joon;Lee, Jae Young;Kim, Hwang-Hee;Jo, Sung Mun;Cha, Sang Sun;Hwang, Seon-Ah;Lee, Seung-Kee;Park, Chan Gi
    • 농업과학연구
    • /
    • 제47권4호
    • /
    • pp.1057-1069
    • /
    • 2020
  • For most upland crops in Korea, underground water is used to ensure an adequate water supply. Thus, surface water storage tanks are needed to supply surface water from reservoirs or streams. This study discusses the design, manufacture and monitoring of a water storage tank capable of reliably supplying water to crops and preventing the inflow of floating debris. The study was conducted in an apple orchard in Yesan-gun, Chungcheongnam-do in Korea. Based on the water requirements of the crops and size of the orchard, a required flow volume of about 0.6 ㎥·h-1 was determined, along with a surface water storage tank capacity of 1.2 ㎥. Following a comparison with other materials, stainless steel (STS) was used to construct the water tank. The tank was designed to provide 14 hours of irrigation, enabling a small-capacity, cost-efficient tank design to be used. A surface water irrigation test was performed using the surface water storage tank. The average surface water irrigation flow rate was 0.00045 ㎥·m-2·h-1. The water quality test showed that the pH, suspended solids (SS), total nitrogen (TN), and total phosphorus (TP) values satisfied the reference values for agricultural water. The test results showed that the surface water storage tank evaluated in this study allows for crop irrigation when there is a lack of groundwater during droughts.