• Title/Summary/Keyword: groundwater pumping capacity

Search Result 32, Processing Time 0.023 seconds

강변여과수 취수에 따른 지하수위의 계절적인 변동 특성

  • Jeong Jae-Yeol;Ham Se-Yeong;Lee Jeong-Hwan;Kim Hyeong-Su;Ryu Sang-Hon;Kim Tae-Won;Kim Mun-Su
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.68-71
    • /
    • 2006
  • Seasonal fluctuation of groundwater level by pumping amount and stream discharge at the riverbank filtrate site adjacent to the Nakdong River in Daesan-Myeon was characterized. Groundwater level fluctuation shows increase in wet season (June, July, August and September) and decrease in dry season (the other months). Seasonal variation of pumping amount shows similar trend to the groundwater fluctuation due to higher consumption of potable water in summer. The relation of specific capacity, Nakdong River and pumping quantity was analyzed. The logarithmic relationship between specific capacity and the stream discharge gives high correlation coefficient, 0.96. This fact indicates that the increase of stream discharge rate reduces the rate of drawdown in the pumping area in wet season.

  • PDF

Study on the Characteristics of Groundwater Movement Caused by Pumping During Drought Period and Estimation of Pumping Capacity in Natural River Estuary (자연하도 하구부에서 갈수시 양수에 의한 지하수 유독특성 및 취수능력 결정에 관한 연구)

  • 안승섭;최윤영
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.39 no.6
    • /
    • pp.88-98
    • /
    • 1997
  • In this study, pumping capacity in the area of natural river estuary is estimated by the quantitative analysis using finite element method. The study area is Iga-ri pumping station in the estuary of Seojung-chun which runs to the East coast. First of aH, hydraulic properties and effects of different seawater levels are analyzed in this area. Variations of groundwater level caused by pumping and properties of seawater intrusion are analyzed, then compared the case of reinforcing the existing intake weir with the case of setting up an weir at the upper stream. The observed data of groundwater drawdown caused by pumping during drought period and seawater intrusion are compared with results of the analysis done by groundwater model using finite element method, and it is found that both are similar. Accordingly, groundwater model used in this study reflects well the variation of groundwater level caused by pumping.

  • PDF

Evaluation of pumping capacity of radial collector wells using Milojevic's equation in the National River Watershed, Korea (Milojevic 경험식을 활용한 주요 국가하천 유역에서 방사형집수정의 강변여과수 취수가능량 평가)

  • Oh, Se-Hyoung;Jeong, Jae-Hoon;Park, Sang-Gyu
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.3
    • /
    • pp.10-20
    • /
    • 2012
  • The pumping capacity of riverbank filtration using radial collector wells at the Geum, Yeongsan, Seomjin, and Nakdong rivers was evaluated using Milojevic's equation. Assessment of the radial collector wells' pumping capacity in riverbank filtration was carried out using a case study in which one set of collector wells is installed in the watershed of each river. Nakdong River was evaluated to have the highest pumping capacity for riverbank filtration. The areas capable of producing over 10,000 $m^3$ per day were found mostly in the Nakdong River.

지하수위를 고려한 양수량 추정

  • 박승기;이승기;정재훈;강성민
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.13-16
    • /
    • 2002
  • The analysis of characteristics of pumping in the small tube well for agriculture were surveyed. Study area was located at the Galsinri in Yesangun near the yedang reservoir. Agricultural electricity using rates for pumping, ground water level and volume of pumping was monitored every week. Pump working ratio and pump efficiency during period of transplanting of rice showed 48.9%, 62.7% respectively.

  • PDF

Study on the aquifer utilization for a ground water heat pump system (지하수 히트펌프 시스템의 대수층 활용 사레 연구)

  • Shim, Byoung-Ohan;Lee, Chul-Woo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.32-35
    • /
    • 2006
  • The validation of a groundwater source heat pump system installation site is estimated by bydrogeothermic model ing. The hydraulic characteristics of the aquifer system is evaluated from pumping and recovery tests. In addition, the temperature distribution by the pumping and the injection of groundwater, and water level fluctuations are simulated by numerical modeling. The total cooling and heating load for the building is designed as 120RT(refrigeration ton) and the ground water source heat pump system covers 50RT as a subsidiary system The scenario of heat pump operation is organized as pumping and inject ion of groundwater that is performed for 8 hours per day in cooling mode for 90 days during the summer season The heat transfer by the injected warm water is limited near the inject ion wells in the simulated temperature distribution. The reason is that the given operation time is too short to expect broad thermal diffusion in large volume of the aquifer in the simulation time The simulated groundwater level and temperature distribution can be used as important data to develope an energy effective pumping and injection well system. Also it will be very useful to evaluate the hydraulic capacity of a target groundwater reservoir.

  • PDF

The Evaluation of Groundwater Pumping Capacity at a Catchment Area with Interrelated Wells in Volcanic Island: I. Without Consideration of Water Quality (상관우물들이 분포하는 화산섬 집수역에 대한 지하수 양수능의 평가 I. 수질(水質)을 고려하지 않은 경우)

  • Lee, Sunhoon;Machida, Isao;Imoto, Yukari
    • Journal of Environmental Impact Assessment
    • /
    • v.12 no.3
    • /
    • pp.189-198
    • /
    • 2003
  • The purpose of this paper is to evaluate the groundwater pumping capadty at a catchment area containing interrelated wells without considering their qualities by using numerical simulation in Miyake Island, young volcanic island with very complicated hydro-geological formations. The groundwater pumping capadties of each well and over entire study area were estimated as the IMY(i,t) by individual withdrawals and the SSMY(t) by simultaneous withdrawals. These results can be used to secure a sure source for taking a plan for supplying water use in young volcanic island as Miyake Island. In simultaneous withdrawals, the withdrawals from well no. 5 and 6 should have the roles as the barrier wells against the intrusion of the groundwater of the part adjacent to Tairo Pond into the inner part of study area. Therefore, it can be suggested to adopt the simultaneous withdrawals as the optimal approach of groundwater management for supplying water use with respect to quantity and quality.

Statistical Analysis of Aquifer Characteristics Using Pumping Test Data of National Groundwater Monitoring Wells for Korea (국가지하수 관측망의 양수시험 자료를 이용한 국내 대수층 특성의 통계적 분석)

  • Jeon Seon-Keum;Koo Min-HO;Kim Yongje;Kang In-Oak
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.6
    • /
    • pp.32-44
    • /
    • 2005
  • 314 pumping test data of the National Groundwater Monitoring Wells (NGMWs) are analyzed to present statistical properties of fractured-rock and alluvial aquifers of Korea such as distribution of hydraulic conductivity, empirical relations between transmissivity and specific capacity, and time-drawdown patterns of pumping and recovery test. The mean hydraulic conductivity of alluvial aquifers (1.26 m/day) is 17 times greater than that of fractured-rock aquifers (0.076 m/day). Hydraulic conductivity of fracture-rock aquifers ranges in value over 4 orders of magnitude which coincide with representative values of fractured crystalline rocks and shows distinctive differences among rock types with the lowest values for metamorphic rocks and the highest values for sedimentary rocks. In consideration of the estimated transmissivity with some simplifying assumptions, it Is likely that $32\%$ of groundwater flow for NGMWs would occur through fractured-rock aquifers and $68\%$ through alluvial aquifers. Based on 314 pairs of data, empirical relations between transmissivity and specific capacity are presented for both fractured-rock and alluvial aquifers. Depending on time-drawdown patterns during pumping and recovery test, NGMWs are classified into $4\~5$ types. Most of NCMWs $(83.7\%)$ exhibit the recharge boundary type, which call be attributed to sources of water supply such as streams adjacent to the pumping well, the vertical groundwater flux between fractured-rock and the alluvial aquifers, and the delayed yield associated with gravity drainage occurring in unconfined aquifers.

Efficiency Assessment of Wastewater Treatment Plant and Groundwater Level by Pump and Treat Technology Applied for Petroleum Contaminated Site (유류오염 지하수 정화를 위한 양수처리법 적용시 지하수위 변화 및 수처리장치의 효율평가)

  • Cho, Chang-Hwan;Kim, Joon-Ho;Park, Min-Kyu;Kim, Tae-Hyung;Choi, Yoen-Soo;Choi, Sang-Il
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.3
    • /
    • pp.33-38
    • /
    • 2014
  • This study was performed to evaluate the applicability of pump and treat technology as well as to identify the changes of groundwater level by continuous pumping at the petroleum contaminated site. A total of 9 monitoring wells were installed at the site and the contaminant concentrations, TPH, benzene, toluene, ethylbenzene and xylene, of groundwater were measured. With the results of the groundwater monitoring, a total of 9 wells were set up for pumping contaminated groundwater in 3 locations. The waste water treatment facility with a capacity of $10m^3/hr$ was installed in the site and operated for about 1 year. The concentrations of the contaminated groundwater from the 3 pumping wells were exceeded groundwater regulation for benzene and TPH. However, the effluent concentration of benzene and TPH was under the regulation showing the maximum level of 0.011 mg/L and 1.2 mg/L during the operation periods. Groundwater levels were decreased by continuous pumping and those were not recovered during the operation period. Groundwater levels of PW-1,2, PW-3,4,5,6 and PW-7,8,9 were decreased about 5 m, 0.7 m, 2 m, respectively. The hydraulic conductivity (K) of the region of PW-1,2, PW-3,4,5,6 and PW-7,8,9 was estimated to be $6.143{\times}10^{-5}cm/sec$, $2.675{\times}10^{-5}cm/sec$, $1.198{\times}10^{-4}cm/sec$. Groundwater level was seemed to be affected not by hydraulic conductivity but by morphological effect. These results show that the pump and treat technology has high applicability for the restoration of petroleum contaminated groundwater but needs continuous monitoring to prevent rapid groundwater drawdown.

Groundwater Productivity and Rehabilitation of Radial Collector Wells for Agriculture near Okseong Underground Dam

  • Jeon, Hang-Tak;Hamm, Se-Yeong;Hong, Soun-Ouk;Lee, Sang Yong;Kim, Hyoung-Soo
    • Journal of the Korean earth science society
    • /
    • v.41 no.4
    • /
    • pp.381-390
    • /
    • 2020
  • When a radial collector well is installed and operated for agricultural purposes, negative impacts may be observed over time due to the clogging of horizontal arms, such as reduced groundwater discharge and water quality deterioration. When radial collector well No. 2 was rehabilitated using the high-pressure impulse generation technique, the specific capacity and transmissivity were increased by 43.1 and 100.6%, respectively. In contrast, according to air surging, the specific capacity and transmissivity increased by 33.8 and 85.8%, respectively, compared to the initial rate before rehabilitation. During the operation of radial collector wells since construction, the time of well rehabilitation can be effectively determined by continuously monitoring the groundwater level and pumping rate of the radial collector wells, thereby preventing a decrease in productivity.

Development of a Groundwater Source Heat Pump in a Fractured Rock Aquifer (암반 대수층에서 개방형 지열 시스템의 개발 및 적용)

  • Shim, Byoung Ohan;Kim, Seong-Kyun;Choi, Hanna;Lee, Soo-Hyoung;Ha, Kyoochul;Kim, Yongchul
    • New & Renewable Energy
    • /
    • v.17 no.3
    • /
    • pp.32-41
    • /
    • 2021
  • A groundwater source heat pump (GWHP) was developed in this study by adapting a borehole heat exchanger with closed-loop and open-loop systems in a new building. In the pilot test building, the air-conditioning on the second floor was designed to employ a closed-loop system and that on the third floor had an open-loop system. The GWHP design is based on the feasibility of groundwater resources at the installation site. For the hydrogeological survey of the study site, pumping and injection tests were conducted, and the feasibility of GWHP installation was evaluated based on the air-conditioning load demand of the building. The site was found to be satisfactory for the design capacity of the thermal load and water quality. In addition, the effect of groundwater movement on the performance of the closed-loop system was tested under three different operational scenarios of groundwater pumping. The performance of the system was sustainable with groundwater flow but declined without appropriate groundwater flow. From long-term observations of the operation, the aquifer temperature change was less than 2℃ at the observation well and 5℃ at the injection well with respect to the initial groundwater temperature. This pilot study is expected to be of guidance for developing GWHPs at fractured rock aquifers.