회귀분석을 이용한 지하수 수위 변화 추정 (Estimation of the Change in Ground Water Level using Regression Analysis)

  • 김상민;안병일
    • 한국농공학회논문집
    • /
    • 제53권6호
    • /
    • pp.51-58
    • /
    • 2011
  • The objective of this study is to identify whether or not the ground water level is decreasing. We suggest a method of estimating the change in groundwater level using newly developed groundwater pumping station data. The Goseong area located in Gyeongnam province was selected considering three factors. First, this area demands relatively large amount of irrigation water because most of the land is used as a paddy field and the proportion of the paddy field within total arable land is increasing. Second, groundwater level data in nearby area are available since these are monitored by Water Management Information System (WAMIS). Third, many groundwater pumping stations have been developed in this area in order to overcome droughts thus detail information for pumping stations are available. Regression results indicate groundwater level has been decreased for over 20 years. This decreasing trend is due to the shortage of surface irrigation water which was caused by the decrease in rainfall.

논산시 왕전리 수막재배지역의 지하수위 변화 (Hydrogeological Characteristics of the Wangjeon-ri PCWC area, Nonsan-city, with an Emphasis on Water Level Variations)

  • 조병욱;윤욱;이병대;고경석
    • 지질공학
    • /
    • 제22권2호
    • /
    • pp.195-205
    • /
    • 2012
  • 겨울철 수막재배를 하고 있는 논산시 왕전리지역의 지하수 취수량감소 원인을 파악하기 위하여 양수시험을 실시하였고, 수막재배에 이용되고 있는 지하수 사용량과 월별 지하수위를 측정하였다. 8개 지하수공에서 양수시험 결과 투수량계수는 $119.9{\sim}388.1m^2/d$, 저류계수는 $1.5{\times}10^{-4}{\sim}5.5{\times}10^{-4}$의 범위이고 주 대수층은 충적층으로 나타났다. 수막재배용 지하수의 양수는 겨울철 약 3개월에 걸쳐서 일어나며 일평균 양수량은 $8,100m^3/d$ 정도였으며 연간 최대 지하수위 변동은 10 m까지 일어나고 있다. 연구지역의 지하수위는 수막재배용 양수가 중단된 지 5개월이 지난 8월에야 완전한 수위회복을 보인다. 이는 연구지역 대수층의 지하수 산출능력에 비해서 겨울철 수막재배시기의 과도한 양수에 의한 것으로 해석된다. 연구지역 중심부 일대의 지하수위는 -3.0~4.38 m로서 연간 8, 9, 10월을 제외한 나머지 9개월은 노성천 하천수위보다 낮아서 하천수가 연구지역으로 유입되는 손실하천의 양상을 띤다. 연구지역에서 겨울철 수막재배에 따른 취수량 감소문제를 해결하기 위해서는 지금보다 규모가 적은 수막재배시설을 운영하여 양수량을 줄이거나 수막재배에 이용된 지하수를 재활용하는 인공함양 수막재배시스템 개발 등이 필요하다.

Analytical Solution for Flow Field by Arbitrarily-Located Multi Injection-Pumping Wells

  • Yoo, In-Wook;Lee, Kang-Kun
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 추계학술발표회
    • /
    • pp.79-82
    • /
    • 2001
  • Analytical solutions have been derived to delineate the capture zone created by pumping wells for the remediation design of contaminated groundwater. These previous analytical solutions are often restricted to pumping wells only, specific well locations, a limited number of wells, and an isotropic aquifer. Analytical solution was developed to deal with arbitrarily located multi injection-pumping wells in an anisotropic homogeneous aquifer. The solution presented in this study provides a simple, easy method for determining tile complex flow field caused by multi injection-pumping wells at different rates, and will consequently be useful in pump-and-treat design.

  • PDF

지하수의 경제성 평가 연구: 지하수 관정을 중심으로 (A Cost-Benefit Analysis of Groundwater: Pumping Wells in Korea)

  • 김선근
    • 자원환경지질
    • /
    • 제47권3호
    • /
    • pp.219-225
    • /
    • 2014
  • 전국의 지하수 관정은 2012년 기준 1,474 천 개소이며 지하수 이용량이 총 용수 이용량의 12%를 차지하고 있다. 수자원장기기본계획은 2021년 전국 용수 수요가 공급을 초과할 것으로 전망하고 있어 지하수 이용이 더욱 중요한 과제가 되고 있다. 우리나라는 지하수 활용을 위한 인공함양이나 강변여과 보다 관정에 크게 의존하고 있으므로 관정의 경제성에 대한 평가가 우선적으로 이루어져야 할 것이다. 따라서 본 논문은 관정에 의한 지하수자원 활용이 경제적인지 아닌지를 분석하는 것에 목적을 둔다. 관정의 편익은 크게 3가지로 나누어 첫째, 활용가치로 음용수 및 농공용수의 공급가치, 둘째 비활용 가치로 잠재활용 대비 미래를 위한 부존가치를 포함하고 있다. 또한 비용은 관정의 설치비용 및 교체비용, 관리비용, 그리고 폐공의 환경오염 비용 등을 모두 포함한다. KDI의 수자원사업 예비타당성 가이드라인과 미국 환경청 그리고 세계은행의 지하수자원 비용-편익분석 모델을 원용하여 관정의 비용편익 비율을 계산하였다. 그 결과 지하수 관정의 편익이 비용보다 2.98배 높아 지하수 관정에 의한 지하수자원 공급이 경제성이 있는 것으로 나타났다.

A Cost-Benefit Analysis of Groundwater Supply through Pumping Well Technology

  • Kim, Sun G.
    • 한국기술혁신학회:학술대회논문집
    • /
    • 한국기술혁신학회 2015년도 추계학술대회 논문집
    • /
    • pp.479-487
    • /
    • 2015
  • 전국의 지하수 관정은 2012년 기준 1,474 천 개소이며 지하수 이용량이 총 용수 이용량의 12%를 차지하고 있다. 수자원장기기본계획은 2021년 전국 용수 수요가 공급을 초과할 것으로 전망하고 있어 지하수 이용이 더욱 중요한 과제가 되고 있다. 우리나라는 지하수 활용을 위한 인공함양이나 강변여과 보다 관정에 크게 의존하고 있으므로 관정의 경제성에 대한 평가가 우선적으로 이루어져야 할 것이다. 따라서 본 논문은 관정에 의한 지하수자원 활용이 경제적인지 아닌지를 분석하는 것에 목적을 둔다. 관정의 편익은 크게 3가지로 나누어 첫째, 활용가치로 음용수 및 농공용수의 공급가치, 둘째 비활용 가치로 잠재활용 대비 미래를 위한 부존가치를 포함하고 있다. 또한 비용은 관정의 설치비용 및 교체비용, 관리비용, 그리고 폐공의 환경오염 비용 등을 모두 포함한다. KDI의 수자원사업 예비타당성 가이드라인과 미국 환경청 그리고 세계은행의 지하수자원 비용-편익분석 모델을 원용하여 관정의 비용편익 비율을 계산하였다. 그 결과 지하수 관정의 편익이 비용보다 2.98배 높아 지하수 관정에 의한 지하수자원 공급이 경제성이 있는 것으로 나타났다.

  • PDF

지하수위를 고려한 양수량 추정

  • 박승기;이승기;정재훈;강성민
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2002년도 추계학술발표회
    • /
    • pp.13-16
    • /
    • 2002
  • The analysis of characteristics of pumping in the small tube well for agriculture were surveyed. Study area was located at the Galsinri in Yesangun near the yedang reservoir. Agricultural electricity using rates for pumping, ground water level and volume of pumping was monitored every week. Pump working ratio and pump efficiency during period of transplanting of rice showed 48.9%, 62.7% respectively.

  • PDF

장기 및 단계 양수시험 시 강변여과 지하수의 수질변화 특성 (Geochemical Characteristics of Groundwater during the Constant and Step-drawdown Pumping Tests at the River Bank Filtration Site)

  • 김규범;신선호;김병우;박준형
    • 한국지반환경공학회 논문집
    • /
    • 제14권8호
    • /
    • pp.11-21
    • /
    • 2013
  • 창녕군 낙동강변의 강변여과 예정 지점에서 양수시험 동안에 발생하는 지하수 내 철과 망간을 포함한 다양한 수질항목 변화를 파악하기 위한 실험을 수행하였다. 5단계의 단계양수시험($500m^3/day{\sim}900m^3/day$) 및 26시간의 장기 양수시험($800m^3/day$) 동안에 양수정과 10개의 관측정에서 지하수 시료를 채취하였다. 장기 양수시험보다는 단계양수시험 기간 동안에 이온 농도의 변화가 뚜렷하였다. 특히, 단계양수시험 동안의 철과 망간 농도의 감소는 양수지점과 대수층의 연결성이 좋아 영향반경이 작은 방향을 따라 뚜렷하게 나타났다. 양수량의 급변에 따라 지하수 흐름에 교란이 발생하고 공기 접촉 등을 통하여 용존 철과 망간의 침전 산화가 촉진되는 것으로 평가되었다. 향후 지하수 내 철과 망간 저감을 위한 효율적인 지중처리 기술 개발을 위해서는 양수정의 운영 방법, 대수층의 공간적 분포 등이 중요한 요인으로 고려되어야 한다.

천부와 심부지하수 양수에 따른 하천수 감소 영향의 비교분석 (Comparative Analysis of Shallow and Deep Groundwater Pumping Effects on Stream Depletion)

  • 이정우;정일문
    • 대한토목학회논문집
    • /
    • 제40권4호
    • /
    • pp.383-391
    • /
    • 2020
  • 본 연구에서는 2층 누수대수층 시스템에 관한 Hunt 해석해와 Ward and Lough 해석해를 이용하여 천부지하수 양수 및 심부지하수 양수로 인한 하천수 감소량을 산정하고 그 차이를 비교, 분석하였다. 하천과 관정간의 이격거리, 대수층의 투수량계수와 저류계수, 상부층과 하부층간의 누수계수의 조합에 따라 총 45,000가지 경우에 대해 지하수 양수량 대비 하천수 감소량인 하천수 감소비를 천부와 심부지하수 양수 각각에 대해 산정하고 그 차이를 정량적으로 분석하였다. 층간 누수계수가 10-61/d로 매우 작은 경우 천부 및 심부지하수 양수로 인한 5년 평균 하천수 감소비의 차이는 수리특성조건에 따라 최대 0.9로 큰 편차를 보이고 천부대수층의 하천고갈인자(SDF)와 지수함수적 감소 관계가 지배적으로 나타났다. 이러한 하천수 감소비의 차이는 층간 누수계수가 증가함에 따라 층간 상호작용 영향으로 SDF 값과의 지수함수적 관계가 점차 둔화되고 누수계수가 10-31/d이 되면 최대 0.2의 작은 차이가 발생하여 층간 수리적 연결성이 큰 조건에서는 하천수 감소에 미치는 지하수 양수 심도의 영향은 거의 없는 것으로 분석되었다.

유류오염 지하수 정화를 위한 양수처리법 적용시 지하수위 변화 및 수처리장치의 효율평가 (Efficiency Assessment of Wastewater Treatment Plant and Groundwater Level by Pump and Treat Technology Applied for Petroleum Contaminated Site)

  • 조장환;김준호;박민규;김태형;최연수;최상일
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제19권3호
    • /
    • pp.33-38
    • /
    • 2014
  • This study was performed to evaluate the applicability of pump and treat technology as well as to identify the changes of groundwater level by continuous pumping at the petroleum contaminated site. A total of 9 monitoring wells were installed at the site and the contaminant concentrations, TPH, benzene, toluene, ethylbenzene and xylene, of groundwater were measured. With the results of the groundwater monitoring, a total of 9 wells were set up for pumping contaminated groundwater in 3 locations. The waste water treatment facility with a capacity of $10m^3/hr$ was installed in the site and operated for about 1 year. The concentrations of the contaminated groundwater from the 3 pumping wells were exceeded groundwater regulation for benzene and TPH. However, the effluent concentration of benzene and TPH was under the regulation showing the maximum level of 0.011 mg/L and 1.2 mg/L during the operation periods. Groundwater levels were decreased by continuous pumping and those were not recovered during the operation period. Groundwater levels of PW-1,2, PW-3,4,5,6 and PW-7,8,9 were decreased about 5 m, 0.7 m, 2 m, respectively. The hydraulic conductivity (K) of the region of PW-1,2, PW-3,4,5,6 and PW-7,8,9 was estimated to be $6.143{\times}10^{-5}cm/sec$, $2.675{\times}10^{-5}cm/sec$, $1.198{\times}10^{-4}cm/sec$. Groundwater level was seemed to be affected not by hydraulic conductivity but by morphological effect. These results show that the pump and treat technology has high applicability for the restoration of petroleum contaminated groundwater but needs continuous monitoring to prevent rapid groundwater drawdown.

초정지역의 지하수 유동해석 (Prediction of Groundwater Level in Chojung Area)

  • 안상도;김경호;정영훈
    • 대한지하수환경학회지
    • /
    • 제7권3호
    • /
    • pp.133-140
    • /
    • 2000
  • 초정지역은 세계 3대 광천수 생산지의 하나로서 지하수 이용업체들이 집중적으로 지하수 개발을 하고 있어 지하수자원의 고갈이 우려되고 있다. 본 연구에서는 초정지역의 지속적인 개발로 인해 장래 예측되는 지하수 장애에 대처하기 위해 수치모형을 이용하여 초정지역의 지하수 유통해석을 수행하였다. 해석 결과 동북쪽에 위치한 산간유역의 수위의 변화에 비하여, 하류 구릉지역에서는 양수정들을 중심으로 수위 강하가 급격하게 일어나고 있다. 이는 하류 구릉지역에 공장들이 밀집하여 있고 생활용수와 농업용수 또한 많은 양을 양수를 하는데 기인한다. 따라서 향후 지하수자원의 고갈이 우려되며, 이에 대한 대책이 심각하게 요구된다.

  • PDF