• Title/Summary/Keyword: ground water quality

Search Result 409, Processing Time 0.031 seconds

Water Quality of Ground Seawater and Trigger Elements for a Cochlodinium polykrikoides Red Tide (Cochlodinium polykrikoides 적조발생에 있어 증식촉진물질의 기원과 지하해수의 수질)

  • Lee, Young-Sik;Kim, Yoon-Bin;Han, Hyung-Gyun
    • Journal of Environmental Science International
    • /
    • v.21 no.9
    • /
    • pp.1079-1085
    • /
    • 2012
  • Ground seawater quality was investigated, and the algal growth potential (AGP) tests were performed along the Tongyeong coast to examine the inflow of materials, which is needed for the red tide species Cochlodinium polykrikoides to grow. The study was conducted to determine the mechanism for C. polykrikoidesred tides. Water temperature, salinity, pH, and dissolved oxygen (DO) ranged from 16.05 to $20.74^{\circ}C$, 18.20 to 32.11 psu, 6.00 to 7.61, and 3.41 to 7.91 mg/L (41.4-96.1%), respectively. No seasonal variation was observed in water temperature. The salinity, pH, and DO saturations at most stations were lower than those of coastal seawater at Tongyeong. The ${NH_4}^+$-N, ${NO_{2+3}}^-$-N, ${PO_4}^{3-}$-P concentrations ranged from 0.43 to 16.00 ${\mu}M$, 1.50 to 132.38 ${\mu}M$, and 1.30 to 6.29 ${\mu}M$, respectively; the values at some stations were much higher than observed in Tongyeong coast seawater. Using seawater from station B, C. polykrikoides grew consistently, with a high growth rate, similar to the red tide in nature. This seawater appeared to contain materials needed by C. polykrikoides to grow. Therefore, C. polykrikoides red tides seem to occur wherever the ground sea water contains materials that are needed for its growth.

Watershed Classification Using Statistical Analysis of water Quality Data from Muju area (무주지역 수질특성자료의 통계학적 분석에 의한 소유역 구분)

  • 한원식;우남칠;이기철;이광식
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.3
    • /
    • pp.19-32
    • /
    • 2002
  • This study is objected to identify the relations between surface- and shallow ground-water and the seasonal variation of their qualities in watersheds near Muju area. The water type shows mainly Ca-$HCO_3$type. Heavy-metal contamination of surface water is locally detected, due to the mixing with mine drainage. In October nitrate concentration is especially high in densely populated area. Cluster Analysis and Principal Component Analysis are implemented to interpret the complexity of the chemical variation of surface- and ground-water with large amount of chemical data. Based on the cluster analysis, surface-water was divided into five groups and ground-water into three groups. Principal Component Analysis efficiently supports the result of cluster analysis, allowing the identification of three main factors controlling the water quality. There are (1) hydrogeochemical factor, (2) anthropogenic factor and (3) heavy metal contaminated by mine drainage.

Hydrogeochemical and geostatistical study of shallow alluvial groundwater in the Youngdeok area

  • Kim, Nam-Jin;Yun, Seong-Taek;Kwon, Man-Jae;Kim, Hyoung-Soo;Kim, Chang-Hoon;Koh, Yong-Kwon
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.232-236
    • /
    • 2000
  • Multi-regression statistical analyses were applied for the water quality data of shallow alluvial ground water (n = 47) collected from the Youngdeok area, in order to quantitatively generalize the natural (non-anthropogenic) causes of regional water quality variation. Seven samples having the high contamination index ( $C_{a}$ > 3) reflect the striong effects by anthropogenic activity. Most of the alluvial groundwaters have acquired their quality primarily due to the dissolution of carbonate minerals. The results of multi-regression analysis show that chlorine is mainly derived from seawater effect. Sulfur isotopic compositions of dissolved sulfur and the S $O_4$/Cl ratio also enable us to discriminate the samples (n = 18) which are affected by atmospheric input of marine aerosol (sea-spray) and also by mixing between freshwater and seawater. Hydrogen and oxygen isotope data of the samples collected lie close to the local meteoric water line obtained from nearby Pohang city but has lower slope (5.45) on the $\delta$D-$^{18}$ O plot, indicating that alluvial groundwater was recharged from infiltrated meteoric water which has undergone some degree of kinetic evaporation. The estimated initial isotopic composition of the recharged water ($\delta$D = -74.8$^{0}$ /$_{00}$, $\delta$$^{18}$ O = -10.8$^{[-1000]}$ /$_{[-1000]}$ ) suggests that the alluvial ground water recharge largely occurs during summer storm events.s.s.

  • PDF

The Analysis of Chloride Ion of Ground Water in the West Coast District of Jeollabuk-Do using Spatial Interpolation (공간보간법을 이용한 전라북도 서해안 지역의 지하수 염소이온 분석)

  • Lee, Geun-Sang;Im, Dong-Gil;Choi, Yun-Woong;Cho, Gi-Sung
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.19 no.4
    • /
    • pp.23-33
    • /
    • 2011
  • In this study, the data that examined the chloride ion concentration of ground water wells in the west coast of Jeollabukdo applying the GIS spatial estimation method were analyzed. In particular, through the designation of a validation point among ground water wells and then the analysis of error characteristics of the chloride ion concentration by each method of IDW (Inverse Distance Weight), Spline, and Kriging Interpolation method which is proper for estimating salt water intrusion was selected. The main conclusion from this study is as follows. First, as a result of analyzing the error characteristics of various spatial estimation methods by using the data from the chloride ion concentration of 485 ground water wells, the IDW method was found to be the most appropriate for estimating chloride ion concentration by salt water intrusion. Second, analyzing the average chloride ion concentration of the targeted regions has revealed that Gunsan-si with the record of $541mg/{\ell}$ did not meet water quality standards even for industrial use. Both Gimje-si and Gochang-gun satisfied drinking water quality standards and Buan-gun with $272mg/{\ell}$ was slightly below the standards for drinking water. Third, concerning the results of analysis according to administrative districts, as the areas adjacent to the west coast such as Daemyeong-dong, Joong-dong, Jangjae-dong and Guemam-dong in Gunsan-si are found to have very high chloride ion concentration, and both Hoehyeon-myeon and Daeya-myeon bounded by the Mankeong river did not meet water quality standards even for industrial use. From these facts, it is concluded that salt water intrusion has a great effect on Gunsan-si generally.

Forecasting Variations of Water Quality Caused by Intercepting Ratios in a Urban River (하수 차집율에 따른 도시하천의 수질변화 예측)

  • Cho, Hong Je;Kim, Jung Sik;Mun, Sung Jun;Park, Jae Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.2
    • /
    • pp.181-195
    • /
    • 2000
  • The effect of the intercepting ratios on the water quality improvement was simulated by using Finite Segment Method in a urban river where intercepting sewer under the ground and constructing sewage treatment plant are now being proceeded. To simulate variations of the water quality caused by river flows, rating curve at each gaging station was derived from measurements. Water quality data were from the exiting observations at each key stations from 1990 to 1998, for 1999 and 2000 data we measured in creek and drainage ditch in addition to observation stations. It revealed that increasing the intercepting ratios improved the water quality.

  • PDF

Comparison of Alternatives of Water-Friendly Facilities in an Industrial Complex (산업단지내 친수시설 대안의 비교)

  • Chung, Sang-Ok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.1570-1576
    • /
    • 2008
  • Construction of the water-friendly facilities in the apartment complex and industrial complex became popular these days. In planning water-friendly facilities, kinds, layouts, water sources, water quality and water circulation system should be studies. In this study, several alternatives for a regional industrial complex project were studies and a most reasonal alternative was selected. A main canal across the central part of the complex is the principle facility with ponds and parks. The water source alternatives were a river nearby, a reservoir, ground water and urban water supply system. For each system, water quantity and quality, circulation system, permit and maintenance were compared. The facilities should be constructed with natural material such as rock and gravel. Average depth and velocity in the canal should be 10 cm and 0.15 m/s, respectively in order to people can feel the water flow in the canal. Based on the comparison, it is found that using the ground water, and water circulation system with storage tanks at the upper and lower ends of the canal system is the best alternative.

  • PDF

Desalination of Seawater by Reverse Osmosis (역삼투법에 의한 해수의 담수화에 관한 연구)

  • Lee, Sun Ju
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.2
    • /
    • pp.155-164
    • /
    • 2004
  • Many countries, including Korea, suffer from a shortage of freshwater. With increases in population and the quality of life, along with large-scale expansion in industrial and agricultural activities, more freshwater is needed. Available resources, Including ground water, are limited, and desalination presents the opportunity for a new unlimited source of freshwater from the sea. The objectives of this study were to test membrane performance in seawater desalination and to examine the quality of water produced. bath well and sea water were used as water sources. Typically used membrane for seawater desalination and high rejection seawater desalination membrane are maintained at almost same recovery rate and permeate flux, while the conductivity was lower in the operation of typically used seawater membrane. The treated water quality using two types of membranes is satisfied with the Korea drinking water quality standards.

Operation Characteristics of Open Type Geothermal Heat Pump (개방형 지열 히트펌프 시스템의 운전 특성)

  • Lim, Hyo-Jae;Kong, Hyoung-Jin;Song, Yoon-Seok;Park, Seong-Koo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.701-706
    • /
    • 2006
  • Groundwater heat pump systems are the oldest of the ground-souce systems and it has various type. Standing column well type are must be located in hard rock geology site and produce sufficient water for the conventional open loop system. These system are indirect type(the building circulating loop and ground water are intercept). Existence of the exchanger the foundation protect water quality to use of open loop. The design of open loop system are concern on the power requirements. An experimental study was analysis the extremely heating operation COP of ground water heat pump system. Operation efficiency of the 50RT systems shows that, COP $2.9{\sim}5.0$ in heating operation. And generally it shows 3.4.

  • PDF

Characteristics of Nutrient Export from Paddy Rice Fields with Irrigation Practices (관개수원에 따른 논에서의 영양물질 배출 특성)

  • Hwang, Ha-Sun;Kong, Dong Soo;Shin, Dong-Suk;Jeon, Ji-Hong
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.6
    • /
    • pp.597-602
    • /
    • 2004
  • Field experimental study was performed to examine characteristics of nutrient export from paddy rice fields with irrigation practices. Experimental fields with surface-water and ground-water irrigation were monitored and analyzed during rice culture period. The water balance showed that outflow generally balanced the inflow showing that about half (58~68%) of total outflow was lost by surface drainage. Water and nutrient export are more in surface-water irrigation paddy than in ground-water irrigation paddy. The reasons might be more irrigation water available and easy to use in surface-water irrigation. If irrigation water reduced, it could result in reduction of nutrient export in paddy rice fields, which can save water and protect water quality. However, deviation from conventional standard practices might affect the rice yield and further investigations are necessary.