• 제목/요약/키워드: ground vibration

검색결과 876건 처리시간 0.028초

방진체결구/방진매트의 진동저감특성에 관한 연구 (A Study on the Vibration Reduction Characteristics of the Elastic Rail Fastener/Ballast Mat)

  • 엄기영;황선근;고태훈;김정근
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2001년도 춘계학술대회 논문집
    • /
    • pp.375-380
    • /
    • 2001
  • Generally, countermeasures for the train-induced vibration are divided into the measures at the source, propagation path and receiving object. Among these measures the countermeasure at the source location is the most active and effective one in the field of railroad. In this study, the effectiveness of each anti-vibration measures at the track(source location) such as elastic rail fastener, ballast mat were evaluated through the comparison of acceleration level, insertion loss at the installed locations of each measures. As result of field measurement of vibration at the railroad track supporting structures and on the ground nearby the structures, elastic rail fastener showed vibration reduction effect of 4.5 ∼7.3㏈ on the concrete slab, 1.6∼3.7㏈ on the ground with the train operation speed of 80km/hr. In the case of ballast mat, the vibration reduction effect at the concrete slab and on the ground were 11.9∼13.3㏈ and 6.1∼7.6㏈, respectively.

  • PDF

노천 굴착에서 발파 진동의 크기를 감소시키기 위한 정밀발파 (Careful Blasting to Reduce the Level of Ground Vibration in Open Excavation)

  • 허진
    • 한국지반공학회지:지반
    • /
    • 제6권3호
    • /
    • pp.5-12
    • /
    • 1990
  • In this paper, ground vibration and other properties measurements were conducted to deter mine empirical equation based on careful test blasting with crawler drill(diameter 70-75mm). The empirical euqations for ground vibration are obtained as follows where V is peak particle velocity in cm 1 sec, D is distance in m and W is maximum charge weight per delay in kg

  • PDF

역사의 방진대책에 따른 진동 저감 예측 (The Prediction of Vibration Reduction due to Vibration Isolating Countermeasure at Railway Station)

  • 이태근;박원기;김병삼
    • 한국기계기술학회지
    • /
    • 제13권1호
    • /
    • pp.11-16
    • /
    • 2011
  • When the trains are passed the station, a serious force is applied to ground and the caused vibration is propagated to the area of the station by the ground and rocks. The caused vibration brings about the operation interruption of the equipment which is sensitive to the vibration, or will bring about the structural damage of the station. In this study, to investigate the vibrational evaluation of railway station by the train service, the vibration simulation was performed and analyzed the effect of the vibration isolating countermeasure. From the vibration measurement, all trains that passed through the station exceeded the vibration criteria. Therefore, the vibration isolating countermeasure was established and the vibration simulation was performed.

저진동 모래다짐말뚝(LVSCP)의 지반개량효과 분석 (Analysis of Ground Improvement Effect of Low Vibration Sand Compaction Pile Method)

  • 김종국;차준태;이재창;채영수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.1234-1242
    • /
    • 2010
  • In this study, the effect of noise and vibration, and influence of ground improvement are evaluated and its application is analyzed through the example of SCP designed at ground improvement in Song-Do international city. consequently, it showes even comfortable result that it is about 5.0m of inner space, when the LVSCP method is applied, rather than that it is about 30m of inner space when the existing SCP is applied in vibration control standards 2.0mm/sec. In the noise, now that the many differences according to environmental factors like other equipment noise, limited space and so on at the time of the construction by LVSCP method are coming out, so we think that appro itate measures are needed according to surroundings. By the way, when it comes to the estimation of the ground improvement work before and after an improvement of LVSCP method, its result shows that it is satisfacttion to all the standards of compaction control in dregded and reclaimed ground and sedimentary clay layer.

  • PDF

터널굴착이 지상구조물에 미치는 영향평가 및 발파지침설계 (Ground Vibration in Tunnelling by Blasting and its Effect on Surface Structures)

  • 신희순;한공창;류창하;신중호;박연준;최영학
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.463-470
    • /
    • 2000
  • In tunnel excavation by blast beneath the surface structures in urban area, the characteristics of ground vibration induced by blast and its influence on surface structures are analyzed by the field test and the numerical analysis on dynamic behaviors of the structure. According to the field test on the propagating characteristics of blast vibration through the rock mass and the concrete foundation pile. the attenuation index of peak particle velocity with distance shows the range of 1.7∼2.0 for the rock mass and the range of 2.0∼2.3 for the concrete pile. This shows that the blast vibration reduces more rapidly in the concrete pile. It is known from the numerical analysis on dynamic behavior of the structure that the coefficient of response, velocity ratio of structure response to input wave, is different according to the story of the structure. It can be said from this research that the characteristics of the ground vibration and the dynamic behavior of the structure should be well evaluated and be considered as important factors for safe blasting design especially in underground excavation at shallow depth in urban area.

  • PDF

흥인지문 인접 CIP공사시 진동 전달 특성 분석 및 평가 사례 연구 (A Case Study of Analysis and Evaluation of Vibration by Construction of Cast in Place Concrete Pile in the Neighboring Areas of Heunginjimun)

  • 최재성;민경원
    • 한국소음진동공학회논문집
    • /
    • 제22권9호
    • /
    • pp.870-878
    • /
    • 2012
  • This paper analysed the effect on Heunginjimun of ground vibrations due to C.I.P. works during Heunginjimun restoration period. Vibration criteria and laws for historic structures was investigated. The vibration was measured under test construction in the field, analysed and evaluated. Because the ground vibration exceeded the vibration criteria, the restoration construction could not be go along. But as vibration was transferred to the upper structures, it was confirmed that vibration levels declined, because of differences between natural and forced frequencies. If the natural frequencies database of historic structures are established, it will help with management and preservation of cultural properties by an environmental vibration effects evaluation.

지반진동과 수중소음의 상관성 연구 (A Study on the Correlation between Underwater Noise and Ground Vibration)

  • 박정봉;강추원;이창원
    • 화약ㆍ발파
    • /
    • 제31권1호
    • /
    • pp.11-22
    • /
    • 2013
  • 본 연구에서는 암반의 굴착(발파)공사 등으로 인하여 발생되는 지반진동과 어패류 양식장 등의 수중 배경소음도 및 실제 발파작업시에 발생하는 수중 대상소음도의 척도를 비교 분석하고, 회귀분석에 의한 지반진동추정식과 수중 대상소음 간의 상관식을 도출하여 굴착공사시 수중소음도의 발생정도를 사전 예측하고자 하였으며, 나아가 수중소음 관리기준의 정립을 위한 첫걸음으로 본 연구를 시작하게 되었다. 그동안 실험을 진행하기 전에 상황조건을 달리한 어패류 양식장에 대해 배경소음도를 측정하여 본 결과 양식장마다 각각의 환경적 특성에 따라 배경소음 수준정도가 다양하게 나타나고 있고, 수중소음을 유발하는 지반진동을 실측하여 지반진동과 수중 대상소음 간의 상호 관계식을 도출할 수 있었다. 따라서 상관식에 의해 각종 건설공사에서 수중소음 유발정도를 사전에 예측하여 당해 실정에 적합한 관리(허용)기준을 설정, 설계 시공 등에 적용할 수 있으므로 과거의 기술적, 공학적 논리의 빈약한 기술전개로 인한 어패류 피해의 경제적 손실을 사전에 예방할 수 있고, 수중생물체에 대한 안전성을 확보한 가운데 원만한 건설공사를 진행할 수 있다는 가능성을 발견할 수 있었다.

Ground vibrations due to underground trains considering soil-tunnel interaction

  • Yang, Y.B.;Hung, H.H.;Hsu, L.C.
    • Interaction and multiscale mechanics
    • /
    • 제1권1호
    • /
    • pp.157-175
    • /
    • 2008
  • A brief review of the research works on ground vibrations caused by trains moving in underground tunnels is first given. Then, the finite/infinite element approach for simulating the soil-tunnel interaction system with semi-infinite domain is summarized. The tunnel is assumed to be embedded in a homogeneous half-space or stratified soil medium. The train moving underground is modeled as an infinite harmonic line load. Factors considered in the parametric studies include the soil stratum depth, damping ratio and shear modulus of the soil with or without tunnel, and the thickness of the tunnel lining. As far as ground vibration is concerned, the existence of a concrete tunnel may somewhat compensate for the loss due to excavation of the tunnel. For a soil stratum resting on a bedrock, the resonance peak and frequency of the ground vibrations caused by the underground load can be rather accurately predicted by ignoring the existence of the tunnel. Other important findings drawn from the parametric studies are given in the conclusion.

스마트 무인기 4자유도 지상시험치구 구조진동해석 (Structural Vibration Analysis of Smart UAV 4-Degree of Freedom Ground Test System)

  • 박강균;최현철;김동만;김동현;안오성
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.593-598
    • /
    • 2009
  • In this study we present results for the design of ground test system for 4 degree of freedom(DOF) control test is one of the smart UAV ground test. This system is equipped with real smart UAV and Z direction DOF and 3 direction rotation DOF, Ensuring safe operation of the Smart UAV is a top priority. To this end, it is required to do structure analysis and test verification to confirm the design margin and safety. Based on the analysis, the ground test system has been redesigned to meet the structural conditions.

  • PDF

실험적 방법에 의한 발파작업으로 기인하는 인접 초정밀 생산장비 FAB에 미치는 진동 영향성 평가 및 제어대책 (A evaluation and countermeasure for blast-induced vibration of micro electronic production facility based on experimental method)

  • 손성완;박상곤;이홍기;전종균
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.875-878
    • /
    • 2006
  • In the case of a vibration sensitive equipment, it require a vibration free environment to provide its proper function, therefore, it is very important to predict precisely vibration environment of microelectronics production facility due to adjacent blast work. However, it is not easy to evaluate a quantitative vibration response of structure due blast because it can be determined by the characteristics of vibration sources, propagation through rock and soil and dynamic properties of building. In this paper, vibration influence evaluation of micro-electronic Production building induced from adjacent blast activity was performed by real measurement data obtained on ground and structure at same time. And blast vibration allowable limit on ground was supposed by measurement data analysis in order to avoid operation error of precision equipments

  • PDF