• Title/Summary/Keyword: ground temperature restoration

Search Result 22, Processing Time 0.029 seconds

Research on Ground Temperature Restoration Characteristics of Large-Scale Ground Source Heat Pump System

  • Zhang, Xu;Liu, Jun;Gao, Jun;Li, Kuishan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.16 no.4
    • /
    • pp.109-116
    • /
    • 2008
  • Ground temperature restoration characteristics are the crucial factors to evaluate whether a ground source heat pump system can keep long time steady operation. They are mainly dependent on soil thermal properties, layout of pile group, operation/shutoff ratio, cooling/heating load, thermal imbalance ratio and so on. On the one hand, several types of vertical pile foundation heat exchangers are intercompared to determine the most efficient one by performance test and numerical method. On the other hand, according to the layout of pile group of a practical engineering and running conditions of a GSHP system in Shanghai, the temperature distribution during a period of five years is numerically studied. The numerical results are analyzed and are used to provide some guidance for the design of large-scale GSHP system.

Fundamental study on the development of Filling materials for Trenchless Emergency Restoration of Ground cavity (비개착식 지반공동 긴급복구를 위한 충전재료 개발에 관한 기초 연구)

  • YU, Nam-Jae;Choi, Ju-Hyun;Lee, Kang-Il
    • Journal of the Korean Geosynthetics Society
    • /
    • v.16 no.2
    • /
    • pp.97-107
    • /
    • 2017
  • Recently, there have been a lot of incidents related to ground sinks in urban areas, but restoration work is complicated and inconvenience due to on-site control, and particularly, grouting and soil filling are generally applied as recovery measures, but when the grouting or the soil filling is carried out, material segregation phenomenon occurs in the ground or a lot of restoration amount is often required, depending on the state of sinks and the existence of groundwater under the ground and the soil can be lost due to the flow of the ground water, and thus the purpose of this study is to develop a pouch-type filler applied to a trenchless method for emergency reinforcement of the ground sinks with the aim of quick recovery of the ground sink in urban areas, and as a result, it was confirmed that compression strength and the expansion ratio were different according to the temperature of ground water and the compression strength and the expansion ratio could be controlled by mixing alumina powder.

Development of calculating daily maximum ground surface temperature depending on fluctuations of impermeable and green area ratio by urban land cover types (도시 토지피복별 불투수면적률과 녹지면적률에 따른 지표면 일최고온도 변화량 산정방법)

  • Kim, Youngran;Hwang, Seonghwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.2
    • /
    • pp.163-174
    • /
    • 2021
  • Heatwaves are one of the most common phenomena originating from changes in the urban thermal environment. They are caused mainly by the evapotranspiration decrease of surface impermeable areas from increases in temperature and reflected heat, leading to a dry urban environment that can deteriorate aspects of everyday life. This study aimed to calculate daily maximum ground surface temperature affecting heatwaves, to quantify the effects of urban thermal environment control through water cycle restoration while validating its feasibility. The maximum surface temperature regression equation according to the impermeable area ratios of urban land cover types was derived. The estimated values from daily maximum ground surface temperature regression equation were compared with actual measured values to validate the calculation method's feasibility. The land cover classification and derivation of specific parameters were conducted by classifying land cover into buildings, roads, rivers, and lands. Detailed parameters were classified by the river area ratio, land impermeable area ratio, and green area ratio of each land-cover type, with the exception of the rivers, to derive the maximum surface temperature regression equation of each land cover type. The regression equation feasibility assessment showed that the estimated maximum surface temperature values were within the level of significance. The maximum surface temperature decreased by 0.0450℃ when the green area ratio increased by 1% and increased by 0.0321℃ when the impermeable area ratio increased by 1%. It was determined that the surface reduction effect through increases in the green area ratio was 29% higher than the increasing effect of surface temperature due to the impermeable land ratio.

Air Temperature Variation by Effect of Green Space Distribution (녹지분포에 따른 기온변화)

  • Yoon, Yong-Han
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.5 no.2
    • /
    • pp.47-52
    • /
    • 2002
  • In this study, in order to find out relationship of green space distribution and lower air temperature effect, observed air temperature distribution in and out green space in the cloudy. On basis of the result, we are analyzed relationship of air temperature distribution in and out green space, of green space distribution and air temperature of, lower air temperature effect and the urban in between the green space by using regression analysis. According to the result, the higher temperature zone formed around urban, and the lower temperature zone was similar to shape of green space. In case of the green space, higher temperature zone is formed around paved surface and barren ground, lower temperature zone is done forest and water area. To compare air temperature of windward and leeward around green space, the windward formed the lower temperature zone and although the wind direction is not the leeward to the green space, air temperature formed lower temperature zone to the urban in between the green space.

Delineation of water seepage in a reservoir embankment from ground temperature measurements (지온탐사에 의한 저수지 제방의 누수 조사)

  • 박삼규
    • Economic and Environmental Geology
    • /
    • v.32 no.2
    • /
    • pp.169-175
    • /
    • 1999
  • The water leakage of reservoir embankment usually occurs through water vein, which gives little influence on the embankment in a normal state. However, the embankment can be destroyed when the water level of reservoir increases with heavy rain in summer. Investigating the water vein and its path is therefore very important from the viewpoint of disater prevention and embankment protection. This paper presents survey results of one-meter-depth ground temperature and multi-point temperature logging in an embankment in Japan to delineate water veins and permeable formations. Four water veins have been predicted in the embankment by comparing measured one-meter-depth ground temperatures with the background ones which have no effect of water vein. The multi-point temperature logging was carried out in the borehole drilled at one of the predicted water veins. Depth and thickness of the permeable formation in the borehole can be determined from temperature restoration ratios with elapsed time. From these results we can find that the water leakage of reservoir embankment mainly occurs in sandy soil formation in the embankment.

  • PDF

Seeding of the Woody Plants for the Quick-coverage of the Slopes (비탈면 조기수림화를 위한 녹화용 식물의 활용에 관한 연구)

  • Kim, Namchoon;Yoon, Jungseo;Bae, Sunwoo;Son, Won-Ju;Jung, Sungchul
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.5 no.6
    • /
    • pp.72-85
    • /
    • 2002
  • This study was conducted to investigate the germination rates and ground coverage rates of the 16 native wild flower, herbaceous, shrub and woody plants according to temperature and seeding timing for the revegetation and rehabilitation of the roadside slopes. Also, this study was conducted to suggest design criteria to select revegetation plants and to decide proper seed mixture for ecological restoration of the disturbed manmade slopes as a environmentally friendly construction. The results are summarized as follows. 1. Most of the plants germinated after 10~14 days. Woody plants germinated more slowly than wild flowers and herbaceous plants because of the hard seed. 2. Most of the plants showed the highest percentage of the germination rates under $15/25^{\circ}C$ temperature. The next was in order of under the $20/30^{\circ}C$ temperature, normal temperature(October) and $25/35^{\circ}C$ temperature. 3. At the chamber experiment, the Sorbaria sorbifolia var. stellipila showed the highest germination rates. Most of the native wild flowers germinated well and showed high germination rates under the various temperature. 4. As the field germination experiments, the seeding at August shows higher germination rates than that of the seeding at September, but showed lower surviving percentage of the germinated seedlings and lower ground coverage percentage than those of the seeding at September. After one year, Chionanthus retusus, Acer palmatum, Albizzia julibrissin are germinated and showed 10% coverage rates. So, they can be used as revegetation plants for the restoration works. 5. As seed mixture experiment, it was not effective only to increase the proportion of the ratio of the tree seeds, relatively high price, for making woody vegetation. It would be more successful to make vegetation structure by natural competition among wild flowers, shrubs and trees. 6. The excessive dominance of trees in revegetation works may destroy the lower layer of vegetation and it will be undesirable on the species diversity. It is more important to recover the species diversity of the plant community by seed mixture with the considering the germination, the growth characteristics and the correlation effect among revegetation plants. 7. To recover the manmade slopes quickly, increasing the ratio of the wild flower was recommended.

Air Temperature Variation by Effect of Green Space Condition (녹지 조건에 따른 기온변화)

  • Yoon, Yong-Han
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.6 no.1
    • /
    • pp.28-33
    • /
    • 2003
  • In this study, we observed air temperature to make clear that land coverage condition and stand form has a certain relationship to air temperature during the night in various green space. And with revolution analysis, we interpreted relationship of air temperature distribution in the green space, The way of analysis is this land coverage rate and air temperature, of number of tree volume of tree air temperature. With this experimental result, we can propose green plan, which is taking into consideration lower effect of air temperature. In this result, lower zone is formed in forest and water area, higher zone is formed in paved surface and barren ground. but this gap is a little. arbor+subarbor area, in the point of water area surrounded stand is formed relative lower air temperature. As a result to make up efficiency lower air temperature area, it is needed to make water area which has surrounded forest, and it is needed to make stand form lower air temperature 2~3 layer forest. In order of arbor, subarbor, shrub, the lower air temperature is more effect.

A Construction of Web-based Decision Making Support System for Artificial Ground Greening (인공지반녹화의 웹 지원 의사결정지원시스템 구축)

  • Lee, Dong-Kun;Park, Chan;Kim, Jae-Uk;Yoon, So-Won;Jang, Seong-Wan;Shin, Sang-Hee
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.11 no.1
    • /
    • pp.62-71
    • /
    • 2008
  • Recently, the expansion of housing developments has reduced green areas in cities. The reduction of green areas caused many negative effects on human beings. For functional improvement of ecosystem, government focuses on artificial ground greening because it gives improving microclimate and saving energy consumption. This research aims to develop the system to support decision making of greening for artificial ground greening. This system consist of rooftop greening, wall greening, and street greening system which can suggest proper type of greening and calculate the effect of the greening considering the proponents inputs. It presents social, economic, and ecological value such as cost, energy saving, and temperature reduction. As it is web-based system users can easily access with internet. This system provides automatic selection modes.As a result, with this developed web-based system, decision makers can evaluate the effect of artificial ground green easily and the support to such movement will increase.

Drought Resistance Assessment of Ground Cover Plants for Low Management and Light Weight Green Roof System (저관리·경량형 옥상녹화를 위한 지피식물의 내건성 평가)

  • Zhao, Hong-Xia;Kang, Tai-Ho
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.16 no.1
    • /
    • pp.83-97
    • /
    • 2013
  • This study was carried out to suggest an experimental base in selecting the drought resistance of plants. Adopting the natural drought method, this paper studies the drought resistance of 12 kinds of ground cover plants. focusing on analyzing the changes of relative water content on leaf, relative electric conductivity and chlorophyll content in 12 kinds of plants, and and the relation between soil water content under drought stress. The drought resistance of the plants were subject to laboratory and rooftop drought resistance treatments. The Logistic model of nonlinear regression analysis was used to evaluate the lethal time that were predicted with the range of 10.4~30.1d on roof top, and 19.5~39.0d on hothouse. The result shows that with the increase of stress time, relative water content and chlorophyll content on leaf were in a downward trend; the relative electric conductivity was upward tendency. Among 12 species of ground cover plants, exclude Pulsatilla koreana, Ainsliaea acerifolia were selected for rooftop plants because they showed resist drought strongly and took adaptive ability.

A Study on Nocturnal Inversion at Urban Area in Winter (동절기 도심지 야간 기온역전에 관한 연구)

  • Zheng, Hai-Yan;Lee, Kyoo-Seock
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2010
  • In urban area, inversion layer prevents air pollutants from being dispersed. To determine nocturnal inversion characteristics at SookMyung Girls' High School near high-rise residential commercial complex buildings in Seoul, air temperature and humidity data were observed at 10minute interval from December 1st, 2007 to May 2nd, 2008. Temperature-Humidity (T-H) sensors were installed at SMG (SookMyung_Ground) and SMR (SookMyung_Roof), and then these two data were compared, analyzed and examined to illustrate air temperature differences of SMG and SMR. After the analysis, the maximum nocturnal inversion was observed by $3.3^{\circ}C$ at 18:10 on December 26th 2007, at that time the weather condition was clear and weak wind. Nocturnal inversions began 2-3 hours before sunset and it reached maximum inversion just after sunset and continued through nighttime until sunrise or 1-2 hours after sunrise. In terms of seasonal variation nocturnal inversions occurred dominantly in March and April rather than winter season.