• 제목/요약/키워드: ground connection

검색결과 309건 처리시간 0.04초

Preliminary study on the ground behavior at shore connection of submerged floating tunnel using numerical analysis

  • Kang, Seok-Jun;Kim, Jung-Tae;Cho, Gye-Chun
    • Geomechanics and Engineering
    • /
    • 제21권2호
    • /
    • pp.133-142
    • /
    • 2020
  • Submerged floating tunnel (SFT) is a type of tunnel which causes the tunnel segments to float in the water. When the SFTs are connected to the ground, the connection between the SFT and the subsea bored tunnel is fragile due to the difference in behavioral characteristics between the two types of tunnels. Therefore, special design and construction methods are needed to ensure the stability of the area around the connection. However, since previous research on the stability of the connection site has not been undertaken enough, the basic step necessitates the evaluation of ground behavior at the shore connection. In this study, the numerical analysis targeting the shore connection between the subsea bored tunnel and the SFT was simulated. The strain concentration at the shore connection was analyzed by numerical simulation and the effects of several factors were examined. The results showed the instability in the ground close to the shore connection due to the imbalance in the behavior of the two types of tunnels; the location of the strain concentration varies with different environmental and structural conditions. It is expected that the results from this study can be utilized in future studies to determine weak points in the shore connection between the submerged floating tunnel and the subsea bored tunnel, and devise methods to mitigate the risks.

Dynamic behavior of submerged floating tunnels at the shore connection considering the use of flexible joints

  • Seok-Jun Kang;Minhyeong Lee;Jun-Beom An;Dong-Hyuk Lee;Gye-Chun Cho
    • Geomechanics and Engineering
    • /
    • 제33권1호
    • /
    • pp.101-112
    • /
    • 2023
  • When a submerged floating tunnel is connected to the ground, there is a risk of stress concentration at the shore connection owing to the displacement imbalance caused by low confinement pressures in water and high confinement pressures in the ground. Here, the effects of the boundary condition and stiffness of the joints installed at the shore connection on the behaviors of a submerged floating tunnel and its shore connection were analyzed using a numerical method. The analysis results obtained with fixed and ground boundaries were similar due to the high stiffness of the ground boundary. However, the stability of the shore connection was found to be improved with the ground boundary as a small displacement was allowed at the boundary. The effect of the joint stiffness was evaluated by investigating the dynamic behavior of the submerged floating tunnel, the magnitude of the load acting on the bored tunnel, and the stress distribution at the shore connection. A lower joint stiffness was found to correspond to more effective relief of the stress concentration at the shore connection. However, it was confirmed that joints with low stiffness also increase the submerged floating tunnel displacement and decrease the frequency of the dynamic behavior, causing a risk of increased resonance when wave loads with low frequency are applied. Therefore, it is necessary to derive the optimal joint stiffness that can achieve both stress concentration relief and resonance prevention during the design of shore connections to secure their dynamic stability.

우주센터 종합조립동 고압가스 운용을 위한 발사체 접속장치 및 고압유연배관 개발 (Development of Launch Vehicle Connection Unit and High Pressure Flexible Hose for KSLV-II Ground Operation)

  • 남중원;전영두;장영순
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.1156-1159
    • /
    • 2017
  • 한국형발사체 및 시험발사체에 대한 지상 운용을 위해서는 우주센터 종합조립동 내에 여러 가지 지상지원장비가 필요하다. 여러 가지 지상지원장비 중 발사체 접속장치와 고압유연배관은 지상의 고압가스 공급장비와 발사체 사이에 고압배관 연결을 위해 필수적인 장비이다. 본 논문에서는 고압가스 연결을 위해 필요한 발사체 접속장치와 고압유연배관에 대한 개요와 개발 진행 상황에 대해 소개하고자 한다.

  • PDF

케이블 TV 전송선로의 특성 개선을 위한 접지방식 (Grounding method for Improving of the Characteristics on Cable TV Transmission Line)

  • 황종선;김영민;연제진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.37-40
    • /
    • 2002
  • Ground connection began by experimenting lightning with the use of a kite and it means electric appliances, communication equipments, measuring instruments and so on connecting the Earth in order to flow away overcharged electricity. There are two kinds of earth connection: Power Ground and Signal Ground. Power Ground is for preventing an electric shock and in general there's no current in the connector. However in an accident, there's a quick flow of electricity out to the Earth. Signal Ground is not only for the safety of appliances but also for the safety of equipment operation. This paper is about connection for noise and interference reduce in order to prevent wrong operation and distortion of signal in the electrical appliances which can take place in cable TV.

  • PDF

CATV 전송선로의 간섭을 줄이기 위한 접지방식에 관한 연구 (A study on the Grounding method for reduce an interference by CATV Transmission Line)

  • 황종선;연제진;박성진;김영민
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.57-60
    • /
    • 2001
  • CATV is the abbreviation for Cable Television. General CATV is a way of multi-channel sending images, voices and music including stillness image as well as characters to public receivers through electrical cable communication system. In the beginning, master antennas were people can not receive TV signal well. TV programs were received from master antennas to TVs in each house. Ground connection began by experimenting lightning with the use of a kite and it means electric appliances, communication equipments, measuring instruments and so on connecting the Earth in order to flow away overcharged electricity. There are two kinds of earth connection: Power Ground and Signal Ground. Power Ground is for preventing an electric shock and in general there's no current in the connector. However in an accident, there's a quick flow of electricity out to the Earth. Signal Ground is not only for the safety of appliances but also for the safety of equipment operation. This paper is about connection for noise and interference reduce in order to prevent wrong operation and distortion of signal in the electrical appliances which can take place in CATV.

  • PDF

CATV 전송선로의 간섭을 줄이기 위한 접지방식에 관한 연구 (A study on the Grounding method for reduce an interference by CATV Transmission Line)

  • 황종선;연제진;박성진;김영민
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.57-60
    • /
    • 2001
  • CATV is the abbreviation for Cable Television. General CATV is a way of multi-channel sending images, voices and music including stillness image as well as characters to public receivers through electrical cable communication system. In the beginning, master antennas were people can not receive TV signal well. TV programs were received from master antennas to TVs in each house. Ground connection began by experimenting lightning with the use of a kite and it means electric appliances, communication equipments, measuring instruments and so on connecting the Earth in order to flow away overcharged electricity. There are two kinds of earth connection: Power Ground and Signal Ground. Power Ground is for preventing an electric shock and in general there's no current in the connector. However in an accident, there's a quick flow of electricity out to the Earth. Signal Ground is not only for the safety of appliances but also for the safety of equipment operation. This paper is about connection for noise and interference reduce in order to prevent wrong operation and distortion of signal in the electrical appliances which can take place in CATV.

  • PDF

수중터널 지반 접속부 안정성 확보를 위한 터널 설계에 대한 수치해석적 연구 (Numerical study on tunnel design for securing stability at connection between submerged floating tunnel and bored tunnel)

  • 강석준;조계춘
    • 한국터널지하공간학회 논문집
    • /
    • 제22권1호
    • /
    • pp.77-89
    • /
    • 2020
  • 수중 부유식 터널은 터널 세그먼트가 부력에 의해 수중에 부유하도록 하는 터널의 한 유형으로, 최근 활발히 연구되고 있다. 수중터널이 지면에 연결되면 수중터널과 지반 내부의 지중터널이 연결되어야 하는데, 두 터널의 서로 다른 구속조건과 거동 특성에 의해 두 터널의 연결부위에 응력이 집중될 가능성이 매우 높다. 따라서 연결부 주변의 안정성을 보장하기 위해 특별한 설계 및 시공 방법을 적용해야 한다. 그러나 연결부 안정성에 대한 기존 연구가 충분히 수행되지 않아서 기본적인 단계의 연결부 안정성 검토에 대한 연구가 필요하다. 이 연구에서는 수중터널과 지중터널의 연결부를 수치해석을 통해 모사하여 연결부 주변 지반에서 전단 변형 집중이 발생하는 것을 확인하였고, 시공 시 처리할 수 있는 구조적 인자가 연결부 주변 지반의 안정성 확보에 어떠한 영향을 가지는지에 대해 분석하였다. 수치해석 결과는 두 종류의 터널이 가지는 변위의 불균형으로 인한 위험이 그라우팅 재료 및 조인트 자유도 구성을 통해 완화될 수 있음을 보였다. 이 연구에서 도출된 결과는 비록 수치해석을 통한 정성적인 결과이지만, 향후 연구에서 수중터널과 지중터널의 연결의 설계 시 주요하게 고려해야 하는 구조적 인자 및 위험 지역을 판단하는 것에 기여할 것이라 판단된다.

이동용 발전기의 접지방식에 관한 연구 (A Study on the Scheme of Ground Connection for the Mobile Generator)

  • 조규덕;김봉태;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.81-84
    • /
    • 2001
  • In industrial field, especially the mobile generator is almost used as a islanding generator source for light, electric thrill, and compressor, and so on. However, because there still exists a lot of aged load, it causes the electric shock against person. In this paper authors introduce the proper method to reduce the electric shock in field discussing the scheme of ground connection.

  • PDF

바이모달 트램의 기준접지 불균등전위에 따른 영향분석 (Effect Analysis for Inequality of Basic Grounding in Bimodal Tram)

  • 이강원;목재균;장세기
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.78-81
    • /
    • 2011
  • Generally, vehicle is insulated from the earth by rubber tire which is intrinsically the insulation material. The electrical ground of vehicle was floated in the sense of electric potential over the electric power sources. First of all, the floated electrical ground of vehicle should be equipotentially connected with the (-) line of electrical equipment. Bimodal tram has the different kinds of electric system. They must be kept insulated to each other electrically. When there is some unbalanced event or connection between them, it will invoke some errors or breakdown to electrical devices including sensors and actuators. This paper has investigated the floating ground effect of bimodal tram built with composite body and shown the effect according to the unbalanced ground of vehicle and the connection between different electric systems.

  • PDF

지주식흙막이의 두부 연결 방법에 따른 안정성에 관한 실험적 연구 (An Experimental Study on the Stability of IER according to the Head Connection Method)

  • 유재원;임종철;서민수;김창영
    • 한국지반공학회논문집
    • /
    • 제32권12호
    • /
    • pp.45-57
    • /
    • 2016
  • IER은 굴착 중에 안정성을 증가시키기 위해서 전면지주에 배면지주를 기울어지게 설치하고 강결시킨 구조이다. IER은 배면지주가 억지말뚝의 역할을 함으로써 전면지주에 발생하는 수평변위를 억제하는 효과가 있고, 전면지주에 작용하는 토압을 분산 시켜 구조적으로 안정한 가시설 공법이다. 본 연구에서는 사질토 지반에서 수치해석과 실내모형실험을 통해 IER의 두부를 강결과 힌지로 조건을 다르게 연결하여 IER의 역학적 특성을 확인하였다. 수치해석 결과, 최대수평변위는 두부의 연결 방법이 강결일 때 힌지일 때의 88%가 발생하고 실내모형실험 결과, 수평변위는 두부 연결 방법이 강결일 때 힌지일 때의 단지 7%만 발생하는 것으로 분석되었다. 또한, 지반의 전단변형 해석 결과 토압은 두부의 연결 방법이 강결일 때 힌지일 때의 67%만 작용하는 것으로 분석되었다.