• Title/Summary/Keyword: ground building

Search Result 1,651, Processing Time 0.024 seconds

Modification of CFD results for Wind Environment in Urban area with Tree Canopy Model (Canopy Model 적용을 통한 도심지 풍환경 예측 CFD 시뮬레이션 결과의 보정)

  • Jung, Su-Hyeon;Hong, In-Pyo;Choi, Jong-Kyu;Song, Doo-Sam
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.spc3
    • /
    • pp.185-193
    • /
    • 2012
  • Recently rapid urbanization facilitates development of high-rise building complex including apartment and office building in urban area. Many problems related with high -rise building are reported. Especially, unpleasant strong winds in pedestrian area are frequently encountered around the high-rise building. CFD simulation methods are used to analyze the wind environment of pedestrian level in high-rise building block. However, the results show differences between CFD and measurement. This difference is attributed to improper use of CFD. Conventional CFD simulation for wind environment around high-rise building does not describe the effect of trees, shrubs and plants near ground which affect the wind environment of pedestrian level. Canopy model can be used to reproduce the aerodynamic effects of trees, shrubs and plants near ground. In this paper, CFD simulation methods coupled with the tree canopy model to predict wind environment of pedestrian level in high-rise residential building block were suggested and the validity was analyzed by comparison between measurement and CFD results.

TORANOMON HILLS - Super High-Rise Building on Urban Highway -

  • Hitomi, Yasuyoshi;Takahashi, Hiroshi;Karasaki, Hidenori
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.3
    • /
    • pp.167-171
    • /
    • 2014
  • TORANOMON HILLS is the main building of a large-scale re-development project located in the center of Tokyo. This high-rise building has a height of 247 m and 52 floors above ground, 5 floors below ground, and $62m{\times}80m$ in plan. It is used as hotel, residential facilities, offices, shops and conference facilities. The super structure is mainly a rigid steel frame with response-control devices, using concrete-filled steel tube columns. The underground section is a mixed structure composed of steel, steel-reinforced concrete and reinforced concrete framings. The piled-raft foundation type is used. The remarkable feature of this high-rise building is that the motorway runs through the basements of the building, which makes it stand just above the motorway. This condition is an important factor of the building design. The plan shape is designed to fit along the curve of the motorway. Special columns at the corners are required to avoid placing columns in the motorway. This special column is a single inclined column in the lower floors that branches into two columns in the mid-floors to suit the column location in the upper floors. The cast steel joint is used for the branching point of each special column to securely transfer the stress.

Fragility Assessment of Damaged Piloti-Type RC Building With/Without BRB Under Successive Earthquakes (연속 지진에 의하여 손상된 필로티 RC 건축물의 BRB 보강 전/후의 취약성 평가)

  • Shin, Jiuk;Kim, JunHee;Lee, Kihak
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.3
    • /
    • pp.133-141
    • /
    • 2013
  • This paper presents the seismic evaluation and prediction of a damaged piloti-type Reinforced Concrete (RC) building before and after post-retrofitting under successive earthquakes. For considering realistic successive earthquakes, the past records measured at the same station were combined. In this study, the damaged RC building due to the first earthquake was retrofitted with a buckling-restrained brace (BRB) before the second earthquake occurred. Nonlinear Time History Analysis (NTHA) was performed under the scaled intensity of the successive ground motions. Based on the extensive structural response data obtained form from the NTHA, the fragility relationships between the ground shaking intensity and the probability of reaching a pre-determined limit state was were derived. In addition, The the fragility curves of the pre-damaged building without and with the BRBs were employed to evaluate the effect of the successive earthquakes and the post-retrofit effect. Through the seismic assessment subjected to the successive records, it was observed that the seismic performance of the pre-damaged building was significantly affected by the severity of the damage from the first earthquake damages and the hysteresis behavior of the retrofit element.

AUTOMATIC GENERATION OF BUILDING FOOTPRINTS FROM AIRBORNE LIDAR DATA

  • Lee, Dong-Cheon;Jung, Hyung-Sup;Yom, Jae-Hong;Lim, Sae-Bom;Kim, Jung-Hyun
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.637-641
    • /
    • 2007
  • Airborne LIDAR (Light Detection and Ranging) technology has reached a degree of the required accuracy in mapping professions, and advanced LIDAR systems are becoming increasingly common in the various fields of application. LiDAR data constitute an excellent source of information for reconstructing the Earth's surface due to capability of rapid and dense 3D spatial data acquisition with high accuracy. However, organizing the LIDAR data and extracting information from the data are difficult tasks because LIDAR data are composed of randomly distributed point clouds and do not provide sufficient semantic information. The main reason for this difficulty in processing LIDAR data is that the data provide only irregularly spaced point coordinates without topological and relational information among the points. This study introduces an efficient and robust method for automatic extraction of building footprints using airborne LIDAR data. The proposed method separates ground and non-ground data based on the histogram analysis and then rearranges the building boundary points using convex hull algorithm to extract building footprints. The method was implemented to LIDAR data of the heavily built-up area. Experimental results showed the feasibility and efficiency of the proposed method for automatic producing building layers of the large scale digital maps and 3D building reconstruction.

  • PDF

Seismic fragility analysis of base isolation reinforced concrete structure building considering performance - a case study for Indonesia

  • Faiz Sulthan;Matsutaro Seki
    • Structural Monitoring and Maintenance
    • /
    • v.10 no.3
    • /
    • pp.243-260
    • /
    • 2023
  • Indonesia has had seismic codes for earthquake-resistant structures designs since 1970 and has been updated five times to the latest in 2019. In updating the Indonesian seismic codes, seismic hazard maps for design also update, and there are changes to the Peak Ground Acceleration (PGA). Indonesian seismic design uses the concept of building performance levels consisting of Immediate occupancy (IO), Life Safety (LS), and Collapse Prevention (CP). Related to this performance level, cases still found that buildings were damaged more than their performance targets after the earthquake. Based on the above issues, this study aims to analyze the performance of base isolation design on existing target buildings and analyze the seismic fragility for a case study in Indonesia. The target building is a prototype design 8-story medium-rise residential building using the reinforced concrete moment frame structure. Seismic fragility analysis uses Incremental Dynamic Analysis (IDA) with Nonlinear Time History Analysis (NLTHA) and eleven selected ground motions based on soil classification, magnitude, fault distance, and earthquake source mechanism. The comparison result of IDA shows a trend of significant performance improvement, with the same performance level target and risk category, the base isolation structure can be used at 1.46-3.20 times higher PGA than the fixed base structure. Then the fragility analysis results show that the fixed base structure has a safety margin of 30% and a base isolation structure of 62.5% from the PGA design. This result is useful for assessing existing buildings or considering a new building's performance.

The contiguity ground and structures sinkage analysis of in city excavation (도심지 굴착공사에 따른 인접지반 및 구조물 침하원인 분석)

  • Seong, Joo-Hyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1301-1306
    • /
    • 2009
  • Recently, urban excavations are one of most frequent geotechnical work according to construction of a high rise building and subway. These kind of excavation affect to a adjacent ground or structure and it can trigger various severe accidents. Generally, the ground is closer to the excavation site, the deformation become larger. In this study, special ground settlement case due to adjacent ground excavation is presented and a cause of deformation is examined by various geotechnical exploration, lab-testing and numerical analysis.

  • PDF

Estimation of Ground-Borne Noise Generated by Subway (지하철 통과 시 지반소음 예측)

  • Kim, Jae-Chul;Koo, Dong-Hoe;Lee, Jun-Suk
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1448-1453
    • /
    • 2008
  • This paper deals with the estimation methods of ground-borne noise generated by subway. Generally, numerical method using by ground model is used to prediction of ground borne noise. However, this method is needed a lots of time to make an analysis and model. In this paper, we describe empirical formula that is based on experimental data for subway and estimate the ground-borne noise propagated from underground station that is builded in the near future to building.

  • PDF

Analysis about Biotope Area Ratio of New Town Housing Complex in the Metropolitan Area of Korea (우리나라 수도권 신도시 주거단지의 생태면적률 분석)

  • Oh, Choong-Hyeon;Kim, Han-Soo
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.34 no.4 s.117
    • /
    • pp.105-115
    • /
    • 2006
  • Biotope Area Ratio ($BFF; BiotopFl{\"{a}}chenFaktor$) was developed in Berlin, Germany in 1990s and introduced to Korea in 1999. It is the ratio of the uncovered soil areas which have the natural circulating capability compared to whole development areas. This study seeks for alternative ways to increase Biotope Area Ratio of residential areas in the metropolitan areas of Korea by investigation on new housing developments. The study investigates four new towns including Seoul Eunpyung new town, Yongin Kusung district, Goyang Pungdong and Juyeopdong districts and Hwasung Dongtan district. The Biotope Area Ratio of study sites is between 23.51 % and 40.69%. This result is not relevant to land use conditions, such as the building-ta-land ratio, natural ground green area ratio. This ratio satisfies the minimum requirements of City of Seoul, except 2 sites. Considering that the study sites are relatively low density land use areas compared to Seoul's average, thus, a higher standards is necessary for new town housing complexes. Because Biotope Area Ratio includes artificial ground green area ratio, Biotope Area Ratio is possible can be increased with decreased natural ground green area ratio. And so, when Biotope Area Ratio is applied to new town development, it must go side by side with a definite natural ground green area ratio.

Parameters affecting the seismic response of buildings under bi-directional excitation

  • Fontara, Ioanna-Kleoniki M.;Kostinakis, Konstantinos G.;Manoukas, Grigorios E.;Athanatopoulou, Asimina M.
    • Structural Engineering and Mechanics
    • /
    • v.53 no.5
    • /
    • pp.957-979
    • /
    • 2015
  • The present paper investigates the influence of the orientation of the ground-motion reference axes, the seismic incident angle and the seismic intensity level on the inelastic response of asymmetric reinforced concrete buildings. A single storey asymmetric building is analyzed by nonlinear dynamic analyses under twenty bi-directional ground motions. The analyses are performed for many angles of incidence and four seismic intensity levels. Moreover three different pairs of the horizontal accelerograms corresponding to the input seismic motion are considered: a) the recorded accelerograms, b) the corresponding uncorrelated accelerograms, and c) the completely correlated accelerograms. The nonlinear response is evaluated by the overall structural damage index. The results of this study demonstrate that the inelastic seismic response depends on the orientation of the ground-motion reference axes, since the three individual pairs of accelerograms corresponding to the same ground motion (recorded, uncorrelated and completely correlated) can cause different structural damage level for the same incident angle. Furthermore, the use of the recorded accelerograms as seismic input does not always lead to the critical case of study. It is also shown that there is not a particular seismic incident angle or range of angles that leads to the maximum values of damage index regardless of the seismic intensity level or the ground-motion reference axes.

Fundamental periods of reinforced concrete building frames resting on sloping ground

  • De, Mithu;Sengupta, Piyali;Chakraborty, Subrata
    • Earthquakes and Structures
    • /
    • v.14 no.4
    • /
    • pp.305-312
    • /
    • 2018
  • Significant research efforts were undertaken to evaluate seismic performance of vertically irregular buildings on flat ground. However, there is scarcity of study on seismic performance of buildings on hill slopes. The present study attempts to investigate seismic behaviour of reinforced concrete irregular stepback building frames with different configurations on sloping ground. Based on extensive regression study of free vibration results of four hundred seventeen frames with varying ground slope, number of story and span number, a modification is proposed to the code based empirical fundamental time period estimation formula. The modification to the fundamental time period estimation formula is a simplified function of ground slope and a newly introduced equivalent height parameter to reflect the effect of stiffness and mass irregularity. The derived empirical formula is successfully validated with various combinations of slope and framing configurations of buildings. The correlation between the predicted and the actual time period obtained from the free vibration analysis results are in good agreement. The various statistical parameters e.g., the root mean square error, coefficient of determination, standard average error generally used for validation of such regression equations also ensure the prediction capability of the proposed empirical relation with reasonable accuracy.