• Title/Summary/Keyword: ground borehole

Search Result 207, Processing Time 0.021 seconds

Analysis of Effective Soil Thermal Conductivities and Borehole Thermal Resistances with a Power Supply Regulation (부하변동에 의한 지중유효열전도도와 보어홀 전열저항 해석)

  • Ro, Jeong-Geun;Yon, Kwang-Seok;Song, Heon
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.80-86
    • /
    • 2011
  • Investigation of the effective soil thermal conductivity(k) is the first step in designing the ground loop heat exchanger(borehole) of a geothermal heat pump system. Another important factor is the borehole thermal resistance($R_b$). Thermal response tests offer a good method to determine the ground thermal properties for the total heat transport in the ground. This is done by supplying a constant heat power into a borehole heat exchanger. There are two methods to supply a constant heat power. One is to employ the electricity provided by Korea Electric Power Corporation(KEPCO). The other is to use electricity generated by a generator. In this study, the power supply regulation was found to reduce when the electricity generated by the generator was used. This is because the generator evaluated with the power supply characteristically reduces the power supply regulation between an overload and a complex using. But it sometimes occurs a power supply regulation in In-situ thermal response test. In this case getting of k,$R_b$ requires delay times and restored normal state. However, the effect of the delay times and restored normal state on the soil thermal conductivity and borehole thermal resistance is very small. Therefore it is possible to use a generally accepted delay times and restored normal state in the analysis. In this work, it is also shown that an acceptable range of ${\Delta}k$, ${\Delta}R_b$ for normal state and regulation state might be approximately 0.01-0.16W/m k, and -0.004-0.007m K/W, respectively. Thus, restored normal state of power supply regulation is valuable to recommend.

Effect of Some Parameters on Ground Effective Thermal Conductivity (지중열교환기 설치 조건이 지중 유효 열전도도에 미치는 영향)

  • Choi, Jae-Ho;Lim, Hyo-Jae;Kong, Hyoung-Jin;Sohn, Byong-Hu
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.33-38
    • /
    • 2008
  • A ground-loop heat exchanger in a ground source heat pump system is an important unit that determines the thermal performance of a system and its initial cost. The Size and performance of this heat exchanger is highly dependent on ground thermal properties. A proper design requires certain site-specific parameters, most importantly the ground effective thermal conductivity, the borehole thermal resistance and the undisturbed ground temperature. This study was performed to investigate the effect of some parameters such as borehole lengths, various grouting materials and U-tube configurations on ground effective thermal conductivity. In this study, thermal response tests were conducted using a testing device with 9-different ground-loop heat exchangers. From the experimental results, the length of ground-loop heat exchanger affects to the effective thermal conductivity. Among the various grouting materials, the bentonite-based grout with silica sand shows the largest thermal conductivity value.

  • PDF

Analysis of Effective Soil Thermal Conductivities and Borehole Thermal Resistances with a Line Source Method (선형열원법에 의한 지중유효열전도도와 보어홀 전열저항 해석)

  • Lee, Se-Kyoun;Woo, Joung-Son;Ro, Jeong-Geun
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.4
    • /
    • pp.71-78
    • /
    • 2010
  • Investigation of the effective soil thermal conductivity(k) is the first step in designing the ground loop heat exchanger(borehole) of a geothermal heat pump system. The line source method is required by New and Renewable Energy Center of Korea Energy Management Corporation in analyzing data obtained from thermal response tests. Another important factor in designing the ground loop heat exchanger is the borehole thermal resistance($R_b$). There are two methods to evaluate $R_b$ : one is to use a line source method, and the other is to use a shape factor of the borehole. In this study, we demonstrated that the line source method produces better results than the shape factor method in evaluating $R_b$. This is because the borehole thermal resistance evaluated with the line source method characteristically reduces the temperature differences between an actual and a theoretical thermal behaviors of the borehole. Evaluation of $R_b$ requires soil volumetric heat capacity. However, the effect of the soil volumetric heat capacity on the borehole thermal resistance is very small. Therefore, it is possible to use a generally accepted average value of soil volumetric heat capacity($=2MJ/m^3{\cdot}K$) in the analysis. In this work, it is also shown that an acceptable range of the initial ignoring time should be in the range of 8~16hrs. Thus, a mean value of 12 hrs is recommended.

Comparative Study on the Characteristics of Ground Vibrations Produced from Borehole Blast Tests Using Electronic and Electric Detonators (전자뇌관과 전기뇌관을 사용한 시추공 발파시험에서의 지반진동 특성에 관한 비교 연구)

  • Choi, Hyung-Bin;Won, Yeon-Ho
    • Explosives and Blasting
    • /
    • v.28 no.2
    • /
    • pp.37-49
    • /
    • 2010
  • Ground vibration caused by blasting in the urban area close to structures can give some indirect damage to human body and may lead to structural damage to buildings. At the stage of design or when complaints were filed by residents, the test blasting in borehole, which is most practical for expressing simple vibration wave form quantitatively, is usually chosen for assessing the degree of damage to structures. In this paper, some lessons gained from the application of electronic detonator triggering system in borehole test blasting are presented. The difference in delay time of detonator when borehole is blasted by electronic detonator and electric detonator are discussed. The peak particle velocities measured at the structure embedded in the similar rock layer to main line of tunnel at test site and measured at the road surface just above the tunnel having different overburden layers were analysed to draw their relationship. By comparing the results with those appearing in some published literatures, the usefulness of the borehole test blasting and the importance of delay time of detonator are addressed.

A Case Study of Electrical Resistivity and Borehole Imaging Methods for Detecting Underground Cavities and Monitoring Ground Subsidence at Abandoned Underground Mines (폐광산 지역의 공동 탐지 및 지반침하 모니터링을 위한 전기비저항탐사와 시추공영상촬영기법 적용 사례)

  • Choi, Jeong-Ryul;Kim, Seung-Sep;Park, Sang-Kyu;Shin, Kwang-Soo;Kang, Byung-Chun
    • Journal of the Korean earth science society
    • /
    • v.34 no.3
    • /
    • pp.195-208
    • /
    • 2013
  • We employed electrical resistivity and optical borehole imaging methods to identify underground cavities and determine ground subsidence rate at the study area affected by land subsidence due to abandoned underground mines. At the study site 1, the anomalous zones of low resistivity ranging between 100 ohm-meter and 150 ohm-meter were observed and confirmed as an abandoned underground mine by subsequent borehole drilling and optical borehole imaging. Although the electrical resistivity survey was unavailable due to the paved surface of the study site 2, we were able to locate another abandoned underground mine with the collapsed mine shaft based on the distribution of the ore veins and confirmed it with borehole drilling. In addition, we measured vertical displacements of underground features indicating underground subsidence by conducting optical borehole imaging 6 times over a period of 43 days at the study site 2. The displacement magnitude at the deep segment caused by subsidence appeared to be 3 times larger than those at the shallow segment. Similarly, the displacement duration at the deep segment was 4 times longer than those at the shallow segment. Therefore, the combination of electrical resistivity and optical borehole imaging methods can be effectively applicable to detect and monitor ground subsidence caused by underground cavities.

A Comparative Study of Density Compensation in Gamma-Gamma Log in PVC Casings between above and below Ground Water Tables (지하수면 상.하부 환경에서의 PVC 케이싱 이격보정 비교 연구)

  • Kim, Yeong-Hwa;Hwang, Byong-Chol;Park, Sung-Geun;Kim, Jong-Man
    • The Journal of Engineering Geology
    • /
    • v.19 no.2
    • /
    • pp.217-225
    • /
    • 2009
  • A series of model borehole experiments and analyses for density compensation were performed to achieve the effective density correction of gamma-gamma log obtained from PVC cased boreholes. A follow-up survey was made for clarifying the variation property of detector responses depending on casing types, the presence of borehole fluid, and the degree of separation between probe and borehole wall. A special emphasis was placed on the comparison of gamma responses obtained from above and below ground water tables. Finally, we could quantify the detector responses as a function of separation between the probe and borehole wall, construct standoff compensation charts, and the limitations of the compensation have been discussed for the environments of both above and below ground water tables.

Thermal Conductivity Estimate of Ground Using Energy Piles (PHC 에너지 파일을 이용한 지반의 열전도도 산정)

  • Yoon, Seok;Go, Gyu-Hyun;Park, Hyun-Ku;Park, Skhan;Lee, Seung-Rae;Cho, Kyung-Jin;Song, Chi-Yong
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.4
    • /
    • pp.8-16
    • /
    • 2012
  • The use of energy pile foundation has been increased for economic utilization of geothermal energy. This paper describes an experimental and numerical study on thermal response tests (TRTs) using W and 3U-shaped ground heat exchangers (GHEs) in precast-high strength concrete (PHC) energy piles. Ground thermal conductivity and borehole thermal resistance were measured and compared with those numerical analysis. W-shpaed GHE showed higher heat transfer behavior than 3U-shaped one because of different conditions such as pile size and volume of grout. That is, ground thermal conductivity using W-shaped GHE was higher than that of 3U shaped GHE, and borehole thermal resistance vice versa. The relative error of borehole resistance values between numerical and analytical solution was less than 5%.

Investigation of ground thermal characteristics for performance analysis of borehole heat exchanger (지중 열교환기 성능 분석을 위한 지반 열물성 조사)

  • Shim, Byoung-Ohan;Song, Yoon-Ho;Kim, Hyoung-Chan;Cho, Byong-Wook;Park, Deok-Won;Im, Do-Hyung;Lee, Young-Min
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.587-590
    • /
    • 2005
  • A detailed geothermal characteristics survey with numerical simulations of the heat transfer in a site for ground source heat pump system is necessary for deploying a shallow geothermal utilization system. Density, specific heat, thermal diffusivity, and thermal conductivity are measured on 91 core samples from a 300 m deep borehole in KIGAM(Korea Institute of Geoscience and Mineral Resources). The heat flow is estimated from the thermal gradient and average thermal conductivity and the correlation between fracture system and hydraulic conductivity is analyzed. From the obtained ground information of the study site the performance of the ground heat pump system can be analyzed with some detailed numerical simulations for seasonal heat pump operation skill and optimal system design techniques.

  • PDF

Numerical Simulation of Borehole Expansion By Pulse Discharge (펄스 방전에 의한 시추공 확공 현상에 대한 수치해석)

  • Park, Hyun-Ku;Lee, Seung-Rae;Kim, Tae-Hoon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1346-1353
    • /
    • 2009
  • In this study, a numerical study was carried out to simulate the expansion of ground borehole by pulse discharge technology using finite element analysis. Considering the mortar in the borehole as an acoustic medium and the surrounding soil as an elasto-plastic material, the strong shock wave developed by the pulse discharge was modeled using the underwater explosion model. The ground expansion was simulated based on a coupled acoustic-structural analysis with varying properties of mortar and soil, and the behavior between acoustic-structural interface.

  • PDF

Climate change in Korea inferred from subsurface temperatures (한국의 지중온도를 이용한 기후변화연구)

  • Lee, Young-Min;Kim, Hyoung-Chan;Song, Yoon-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.442-444
    • /
    • 2006
  • On long time scale and over large areas ground surface temperatures (GSTs) track surface air temperatures (SATs). Additionally, GST changes penetrate into the subsurface and are recorded as transient temperature perturbation to the background thermal filed. Therefore, climate change can be reconstructed from borehole temperature measurements We present GST hi story reconstructed from temperature measurements in a borehole at Pocheon The result shows that GST cold period in the late 19th century and then increased by about 2K to 1990. GST history matches well with surface air temperatures measured from 1907 to 2001 at the Seoul Meteorological Station and GST history reconstructed from temperature measurements in three boreholes at Ulsan.

  • PDF