• 제목/요약/키워드: grid technology

검색결과 2,289건 처리시간 0.032초

A Stable Operation Strategy in Micro-grid Systems without Diesel Generators

  • Choi, Sung-Sik;Kang, Min-Kwan;Lee, Hu-Dong;Nam, Yang-Hyun;Rho, Dae-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.114-123
    • /
    • 2018
  • Recently, as one of the countermeasures to reduce carbon dioxide($CO_2$) for global warming problems, operation methods in micro-grid systems replacing diesel generator with renewable energy sources including wind power(WP) and photovoltaic(PV) system have been studied and presented in energetic manners. However, it is reported that some operation problems in micro-grid systems without diesel generator for carbon-free island are being occurred when large scaled WP systems are at start-up. To overcome these problems, this paper proposes an operation strategy in micro-grid systems by adapting control devices such as CVCF(constant voltage constant frequency) ESS(energy storage system) for constant frequency and voltage regulation, load control ESS for balancing demand and supply and SVC(static-var compensator) for reactive power compensation. From the simulation results based on the various operation scenarios, it is confirmed that the proposed operation strategy in micro-grid systems without diesel generators is a useful tool to perform a stable operation in micro-grid systems without diesel generator and also make a contribution to reduce carbon dioxide in micro-grid systems.

30kW급 CVCF 인버터 기반 Micro-grid의 구현 및 과도상태 운용특성에 관한 연구 (A Study on Transient Operation Characteristics of 30kW Scale CVCF Inverter based Micro-grid)

  • 이후동;최성식;페레이라 마리토;박지현;노대석
    • 한국산학기술학회논문지
    • /
    • 제20권10호
    • /
    • pp.18-25
    • /
    • 2019
  • 최근, 도서지역의 신재생에너지전원 및 ESS의 도입이 확대되면서, 이산화탄소 배출의 저감을 위하여, 디젤발전기 대신 CVCF 인버터가 주 전원인 Micro-grid를 안정적으로 운용하는 방안들이 연구되고 있다. 그러나, CVCF 인버터 기반의 Micro-grid에서는 전체 부하보다 신재생에너지전원의 출력이 큰 경우에 에너지 Sinking(과도상태) 현상이 발생하게 된다. 이 때, CVCF 인버터용 배터리의 SOC 상태에 따라, 배터리 전압이 급격히 상승하여, 인버터의 과전압 보호동작에 의해 CVCF 인버터가 탈락되어 Micro-grid 전체 계통에 정전을 유발할 수 있다. 따라서, 본 논문에서는 CVCF 인버터를 기반으로 한 도서지역용 Micro-grid의 안정적인 운용을 위하여, 에너지 Sinking이 발생한 경우의 운용특성을 분석하고, CVCF 인버터가 에너지 Sinking 시에 탈락되는 것을 사전에 방지할 수 있는 Micro-grid의 과도상태 운용전략을 제안한다. 또한, CVCF 인버터, 태양광전원, 수용가부하로 구성된 30kW급 Micro-grid 시험장치를 구현하여, 실 계통에서의 에너지 Sinking에 의한 CVCF 인버터 기반 Micro-grid의 과도상태 시 운용특성을 제시한다. 한편, 30kW급 시험장치와 제안한 운용전략을 바탕으로 Micro-grid의 과도상태 운용특성을 분석한 결과, CVCF 인버터용 배터리의 전압과 SOC에 따라 인버터가 탈락하는 과도상태를 사전에 방지할 수 있어, 본 논문의 유용성을 확인하였다.

BGA(Ball Grid Array) 높이 데이타의 고속 측정 (High Speed Measurement of Ball Height Data for Ball Grid Arrays)

  • 조태훈;주효남
    • 반도체디스플레이기술학회지
    • /
    • 제5권1호
    • /
    • pp.1-4
    • /
    • 2006
  • Recently, Ball Grid Arrays(BGAs) are getting used more frequently for a package type. The connectors on a BGA consist of a large number of small solder balls in a grid shape on its bottom side. However, since balls of BGAs mounted on PCBs are not visible, inspection before mounting them is indispensable. High speed non-contact 3D measurement technologies are necessary far real-time measurement of ball height, the most important inspection item. In this paper, an accurate 3D data acquisition system for BGAs is proposed that can acquire 3D profile at high speed using a 3D smart camera and laser slit ray projection. Some clipping and morphological filtering operations are employed to remove spiky error data, which occur due to reflections from some ball area to camera direction.

  • PDF

가파도 마이크로그리드에서의 풍력발전 연계를 위한 2MVA급 배터리 에너지 저장시스템(BESS) 적용 및 실증 (The Application and Verification of the 2MVA Battery Energy Storage System(BESS) with Wind-turbine in Micro-grid of Gapado, Jeju)

  • 김승모;오승진;이종학;김태형;권병기;안재민;진경민;최창호
    • 전력전자학회논문지
    • /
    • 제19권4호
    • /
    • pp.303-311
    • /
    • 2014
  • This paper shows the test result of 2MVA BESS(Battery Energy Storage System) with wind-turbine in micro-grid of the Gapado. To implement of micro-grid with BESS, characteristics of generator and customer load in grid are considered. Also, to operate of 2-parallel PCU(Power Conversion Unit) in BESS, the droop control is adopted with operating mode of grid independent. Performances of BESS with wind-turbine were verified by analysis of power quality such as voltage harmonics, ratio of voltage and frequency regulation, and by measurement of waveform such as output voltage and current.

Techno-economic design of a grid-tied Photovoltaic system for a residential building

  • Asad A. Naqvi;Talha Bin Nadeem;Ahsan Ahmed;Muhammad Uzair;S. Asad Ali Zaidi
    • Advances in Energy Research
    • /
    • 제8권1호
    • /
    • pp.59-71
    • /
    • 2022
  • Increasing cost of electricity due to rising price of fuel is one of the local community's main issues. In this research, switching of grid dependent system to the grid-tied Photovoltaic (PV) system with net metering for a residential building is proposed. The system is designed by considering the maximum energy demand of the building. The designed system is analyzed using RETScreen on technical, economic and environmental grounds. It is found that the system is able to produce 12,000 kWh/year. The system is capable to fulfill the electricity demand of the building during day time and is also capable to sell the energy to the local grid causing the electric meter to run in reverse direction. During night time, electricity will be purchased from grid, and electric meter will run in the forward direction. The system is economically justified with a payback period of only 3 years with net present value of PKR. 4,758,132. Also, the system is able to reduce 7.2 tons of CO2 not produced in the entire life of the project.

Electricity Market Design for the Incorporation of Various Demand-Side Resources in the Jeju Smart Grid Test-bed

  • Park, Man-Guen;Cho, Seong-Bin;Chung, Koo-Hyung;Moon, Kyeong-Seob;Roh, Jae-Hyung
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.1851-1863
    • /
    • 2014
  • Many countries are increasing their investments in smart grid technology to enhance energy efficiency, address climate change, and trigger a green energy revolution. In addition to these goals, Korea also seeks to promote national competitiveness, prepare for the growth of the renewable energy industry, and export industrialization through its strategic promotion of the smart grid. Given its inherent representativeness for Korean implementation of the smart grid and its growth potential, Jeju Island was selected by the Korean government as the site for smart grid testing in June 2009. This paper presents a new design for the electricity market and an operational scheme for testing Smart Electricity Services in the Jeju smart grid demonstration project. The Jeju smart grid test-bed electricity market is constructed on the basis of day-ahead and real-time markets to provide two-way electricity transaction environments. The experience of the test-bed market operation shows that the competitive electricity market can facilitate the smart grid deployment in Korea by allowing various demand side resources to be active market players.

UNSTRUCTURED MOVING-GRID FINITE-VOLUME METHOD FOR UNSTEADY SHOCKED FLOWS

  • Yamakawa M;Matsuno K
    • 한국전산유체공학회지
    • /
    • 제10권1호
    • /
    • pp.24-30
    • /
    • 2005
  • Unstructured grid system is suitable for flows of complex geometries. For problems with moving boundary walls, the grid system must be time-dependently changing and deforming according to the movement of the boundaries when we use a body fitted grid system. In this paper, a new moving-grid finite-volume method on unstructured grid system is proposed and developed for unsteady compressible flows with shock waves. To assure geometric conservation laws on moving grid system, a control volume on the space-time unified domain is adopted for estimating numerical flux. The method is described and applied for two-dimensional flows.

자연형 IVB(Independent Visual Background)의 Simulator Sickness 감소효과 (Effects of Natural Independent Visual Background for Reducing Simulator Sickness)

  • 김도회;임정위
    • 산업경영시스템학회지
    • /
    • 제25권3호
    • /
    • pp.28-33
    • /
    • 2002
  • Several studies indicated that an independent visual background (IVB) reduced simulator sickness (SS) and balance disturbance associated with exposure to virtual environments (VEs) and motion simulators. A recent study showed that an IVB comprised of an earth-fixed grid was less effective in a complex driving simulator than in a simple VE. Subjects' post-experiment reports indicated that the VE motion "induced" motion of the earth-fixed grid m. This led to the suggestion that an IVB comprised of clouds would be less subject to induced motion and therefore would alleviate nausea more effectively than a grid IVB. Clouds are "natural" and are usually perceived as relatively stable, whereas a grid has no inherent stability. 12 subjects were exposed to complex motion through a simulated environment in a driving simulator under 3 IVB conditions: grid, less clouds, many clouds. They reported less nausea when the many-cloud IVB was used relative to the grid IVB condition. grid IVB condition.

Voltage Distortion Approach for Output Filter Design for Off-Grid and Grid-Connected PWM Inverters

  • Husev, Oleksandr;Chub, Andrii;Romero-Cadaval, Enrique;Roncero-Clemente, Carlos;Vinnikov, Dmitri
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.278-287
    • /
    • 2015
  • This paper proposes a novel voltage distortion approach for output filter design based on the voltage transfer function for both off-grid and grid-connected Pulse Width Modulation (PWM) Inverters. The method explained in detail is compared to conventional methods. A comparative analysis is performed on an example of L and LCL-filter design. Simulation and experimental results for the off-grid and the grid-connected single phase inverter prove our theoretical predictions. It was found that conventional methods define redundant values of the output filter elements. Assumptions and limitations of the proposed approach are also discussed.

Observer-based Voltage Sensorless Control Scheme for an LCL-filtered Grid-connected Inverter

  • Lai, Ngoc Bao;Kim, Kyeong-Hwa
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.266-267
    • /
    • 2017
  • To synchronize the distributed generation (DG) unit with the grid, the voltage sensors are generally employed to obtain the grid phase angle. This paper presents an observer-based voltage sensorless control scheme for a three-phase inverter connected to the grid through an LCL filter. The proposed control scheme consists of an augmented state observer and a feedback controller. The augmented state observer is used to estimate the grid voltages and states of the inverter system, which are then employed to determine the grid voltage angle and to construct the feedback controller. As a result of using the observer, only the grid current sensors are required to accomplish the control scheme. The simulation results are given to prove the validity of the proposed control scheme.

  • PDF