• Title/Summary/Keyword: grid technology

Search Result 2,287, Processing Time 0.047 seconds

The Implementation of a Pipe-lined Grid Coverage and Grid Coverage Processor

  • Kim, Hong-Gab;Kim, Kyung-Ok
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.70-73
    • /
    • 2002
  • This paper describes the way to embody the grid coverage and the grid coverage processor which can construct pipelines. The pipeline constructed by the developed grid coverages has internal pipelines that have different resolution and it provides the way of access to very large datasets efficiently. Several operations, such as filtering, image enhancement and band operation, are embedded in the developed grid coverage and grid coverage processor COM components. The practical usefulness of the developed grid coverage and grid coverage processor has been proven by applying them in developing an image processing software for very large images.

  • PDF

A Study of Applying BlackList for Smart Grid Vulnerability and Security (BlackList의 Smart Grid 취약점 및 보안 적용 방법 연구)

  • Lee, Bo-Man;Park, Dea-Woo
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2011.06a
    • /
    • pp.101-104
    • /
    • 2011
  • 지능형 전력망인 Smart Grid의 등장으로 미국, 일본 등의 국가는 Smart Grid 시장을 선점하기 위해 노력하고 있다. 한국 또한 경쟁국으로서 G20 정상회의에서 Smart Grid 시범 단지를 선보이려고 준비 중에 있다. Smart Grid의 발전에 기본적인 전력기기와 IT기기의 융합 모델인 전력IT기기의 연구가 진행되고 있고, 단일 전력 기기일 때와는 달리 IT 기기의 특성에 따른 보안 문제에 노출되어 보안에 대한 연구가 필수적이다. 본 논문에서는 Smart Grid에 사용되는 전력 IT 기기에 적용 할 수 있는 보안 방법인 BlackList 설정을 연구하여 Smart Grid 시대의 발전에 기여 할 것이다.

  • PDF

Comparison of Three Active-Frequency-Drift Islanding Detection Methods for Single-Phase Grid-Connected Inverters

  • Kan, Jia-rong;Jiang, Hui;Tang, Yu;Wu, Dong-chun;Wu, Yun-ya;Wu, Jiang
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.509-518
    • /
    • 2019
  • A novel islanding detection method is proposed in this paper. It is based on a frequency drooping PLL, which was presented in a previous work. The cause of errors in the non-detection zone (NDZ) of conventional frequency disturbance islanding detection methods (IDM) is analyzed. A frequency drooping phase-locked-loop (FD-PLL) is introduced into a single-phase grid-connected inverter (SPGCI), which can guarantee that grid current is in phase with the grid voltage. A novel FD-PLL IDM is proposed by improving this PLL. In order to verify the performance of the proposed FD-PLL IDM, a full performance comparison between the proposed IDM and typical existing active frequency drift IDMs is carried out, which includes both dynamic performance and steady performance. With the same NDZ, the total harmonic distortion of the grid-current in the dynamic process and steady state is analyzed. The proposed FD-PLL IDM, regardless of the dynamic or steady process, has the best power quality. Experimental and simulation results verify that the proposed FD-PLL IDM has excellent performance.

PLC-Based Smart grid Home Network System Design and Implementation using OPNET Simulation

  • Huh, Jun-Ho;Seo, Kyungryong
    • Journal of Multimedia Information System
    • /
    • v.1 no.2
    • /
    • pp.111-118
    • /
    • 2014
  • The Smart grid refers to the technology that enables efficient usage of electric power by collecting information concerning the power usage and power lines grafting information and communications technology to onto power grids. There are Zigbee, PLC or IEEE 802.11 WLAN MAC as a core technology of the Smart grid, but in this paper, the discussion is focused on the PLC. The PLC is the technology that carries out data communications using power lines and put into practical use in the field of lights or home appliances control recently but PLC-applied communications between electronic devices are rarely seen. For the reason that the PLC uses high-voltage power lines and has a disadvantage of experiencing higher data loss rate caused by the noises produced by going through transformers, the technology is yet to be used in many areas. Nevertheless, the PLC has been studied widely recently in respect that it's the low-cost communication solution for the Smart Metering [1]. Moreover, this technology is emerging as a novel data communication method and discussed as an important technology lately due to the developments of the Smart grid systems and Internet of things (IoT). Thus, in this paper, the results obtained from designing and performing implementation scenario for the PLC-based Smart grid home network system were compared and analyzed with that of IEEE 802.11 WLAN MAC (the foundation technology at Jeju Smart grid Test bed)-based Smart grid home network. Thus, in this paper, OPNET 14.5 PL8, OSI 7 layer, PLC router nodes and PLC nodes had been used for the designing and implementation simulations of both systems. Additionally, QoS was not considered in order to guarantee that all the traffics would not have the same processing priority.

  • PDF

A Study on the Operation Algorithm for Micro-Grid (마이크로그리드의 운용 알고리즘에 관한 연구)

  • Park, Hyeon-Seok;Rho, Dae-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2007.11a
    • /
    • pp.136-139
    • /
    • 2007
  • 최근, 이러한 주변정세는 차세대의 배전계통이 다수의 Micro-grid들로 구성될 것이라고 하는 예상을 전문가들로부터 제기되기에 이르렀다. 그러나 제안된 Micro-grid는 몇몇의 분산전원과 전력품질을 보상하는 기기, 그리고 통신제어설비와 부하들로 구성된다는 기본적인 내용에 지나지 않는다. 본 논문에서는 소형동기발전기(Micro Synchronous Generator), PWM컨버터, 대용량 커패시터, PWM인버터, SSB(Solid State Breaker) 로 구성되는 Micro-grid의 Topology와 모델링 방법, 그 운전 알고리즘을 제안하고, 이를 시뮬레이션을 통하여 제안된 Micro-grid의 기능을 검증하기로 한다.

  • PDF

Accounting Information Gathering System for Grid Environment

  • Jang Haeng Jin;Doo Gil Su;Lee Jeong Jin;Kim Beob Kyun;Hwang Ho Jeon;An Dong Un;Chung Seung Jong
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.703-706
    • /
    • 2004
  • Grid computing represents the fundamental computing shift from a localized resource computing model to a fully-distributed virtual organization with shared resources. Accounting is one of the main obstacles to widespread adoption of the grid. Accounting has until recently, been a sparsely-addressed problem, particularly in practice. In this paper, we design and implement the accounting information gathering system. Implemented system is based on OGSA, following GSAX framework of RUS-WG in GGF. And the schema of gathered and serviced accounting information is following Usage Record Fields of UR-WG in GGF. Also, the accounting information integrating and monitoring tool for system management in the grid environment are implemented.

  • PDF

Vulnerability Analysis and Security Measures according to Smart Grid Attack Case (Smart Grid 공격 사례와 취약점 분석 및 보안대책)

  • Chun, Woo-Sung;Park, Dea-Woo
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2011.06a
    • /
    • pp.75-77
    • /
    • 2011
  • Smart Grid는 전기망과 정보통신망이 융합된 형태로 발전 송전 배전의 전 과정에 대한 통제가 가능하고, 결과적으로 에너지 사용의 효율성을 높이고자 하는 것이 지능형 전기망이다. 정보통신망을 이용하기 때문에 기존의 다양한 사이버 보안위협으로부터 그대로 노출되어 있으며, 전기망에서의 취약점도 함께 가지고 있다. 본 논문에서는 우리나라보다 먼저 Smart Grid를 도입한 나라의 Smart Grid 공격 사례와 예상 공격에 대한 취약점을 분석하고, 분석된 취약점에 대한 Smart Grid 보안 대책을 마련한다. 본 연구를 통해 Smart Grid에 대한 보안성 강화와 사회안정성 향상에 기여하게 될 것이다.

  • PDF

Co-design of the LCL Filter and Control for Grid-Connected Inverters

  • Zhang, Yu;Xue, Mingyu;Li, Minying;Kang, Yong;Guerrero, Josep M.
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.1047-1056
    • /
    • 2014
  • In most grid-connected inverters (GCI) with an LCL filter, since the design of both the LCL filter and the controller is done separately, considerable tuning efforts have to be exerted when compared to inverters using an L filter. Consequently, an integrated co-design of the filter and the controller for an LCL-type GCI is proposed in this paper. The control strategy includes only a PI current controller and a proportional grid voltage feed-forward controller. The capacitor is removed from the LCL filer and the design procedure starts from an L-type GCI with a PI current controller. After the PI controller has been settled, the capacitor is added back to the filter. Hence, it introduces a resonance frequency, which is identified based on the crossover frequencies to accommodate the preset PI controller. Using the proposed co-design method, harmonic standards are satisfied and other practical constraints are met. Furthermore, the grid voltage feed-forward control can bring an inherent damping characteristic. In such a way, the good control performance offered by the original L-type GCI and the sharp harmonic attenuation offered by the latter designed LCL filter can be well integrated. Moreover, only the grid current and grid voltage are sensed. Simulation and experimental results verify the feasibility of the proposed design methodology.