• Title/Summary/Keyword: greenhouse test

Search Result 434, Processing Time 0.034 seconds

Heat Recovery Characteristics of the Hot Water Supply System with Exhaust Heat Recovery Unit Attached to the Hot Air Heater for Plant Bed Heating in the Greenhouse (온풍난방기의 배기열을 이용한 지중 난방용 온수공급시스템의 열회수특성)

  • 김영중;유영선;장진택;강금춘;이건중;신정웅
    • Journal of Biosystems Engineering
    • /
    • v.25 no.3
    • /
    • pp.221-226
    • /
    • 2000
  • Hot air heater with light oil burner is the most common heater for greenhouse heating in the winter season in Korea. However, since the thermal efficiency of the heater is about 80∼85%, considerable unused heat amount in the form of exhaust gas heat discharges to atmosphere. In order to capture this exhaust heat a heat recovery system for plant bed heating in the greenhouse was built and tested in the hot air heating system of greenhouse. The heat recovery system is made for plant bed or soil heating in the greenhouse. The system consisted of a heat exchanger made of copper pipes, ${\Phi}12.7{\times}0.7t$ located in the rectangular column of $330{\times}330{\times}900mm$, a water circulation pump, circulation plastic pipe and a water tank. The total heat exchanger area is 1.5$m^2$, calculated considering the heat exchange amount between flue gas and water circulated in the copper pipes. The system was attached to the exhaust gas path. The heat recovery system was designed as to even recapture the latent heat of flue gas when exposing to low temperature water in the heat exchanger. According to the performance test it could recover 45,200 to 51,000kJ/hr depending on the water circulation rates of 330 to $690\ell$/hr from the waste heat discharged. The exhaust gas temperature left the heat exchanger dropped to $100^{\circ}C$ from $270^{\circ}C$ by the heat exchange between the water and the flue gas, while water gained the difference and temperature increased to $38^{\circ}C$ from $21^{\circ}C$ at the water flow rate of $690\ell$/hr. By the feasibility test conducted in the greenhouse, the system did not encounter any difficulty in operations. And, the system could recover 220,235kJ of exhaust gas heat in a day, which is equivalent of 34% of the fuel consumption by the water boiler for plant bed heating of 0.2ha in the greenhouse.

  • PDF

Effect of Plant Age on Infection of Soybean by Calonectria ilicicola (Calonectria ilicicola의 감염에 대한 콩 식물체 나이가 미치는 영향)

  • ;J. S. Russi;J. P. Snow
    • Korean Journal Plant Pathology
    • /
    • v.14 no.3
    • /
    • pp.247-252
    • /
    • 1998
  • A series of greenhouse test was conducted to evaluate infection of Calonectria ilicicola on soybean plants of different ages at time of inoculation. Lesion length and number of perithecia were determined on cultivars Braxton, Deltapine 726, and Riverside 699 that were 10∼40 days old and 4-10 days old at time of inoculation. Quadratic and linear relationships were described between plant age at inoculation and lesion length or perithecia production in greenhouse studies. Soybean seedlings exhibited low susceptibility to C. ilicicola regardless of cultivar susceptibility. On 8- or 1-0-days-old Braxton, lesion lenght and perithecia numbers were reduced. Lesion lengths were longest on plants 30 days old whereas perithecia production was greatest on plants 20∼30 days old at time of inoculation. Differences in lesion length and perithecia production that were observed on young plants (4∼10 days old) were similar to relative levels of susceptibility in soybean cultivars in greenhouse and field tests, suggesting that reaction to C. ilicicola in soybean cultivars may be determined early in plant development.

  • PDF

A Study on the Standard Durable Years of Pipe Framed Greenhouses (파이프 골조 온실 구조물의 표준내용연수 연구)

  • 남상운
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.43 no.1
    • /
    • pp.96-101
    • /
    • 2001
  • In designing the greenhouse structures, snow and wind loads must be estimated on the basis of the probability of occurrence of snow or wind storms of a given intensity. The recurrence interval chosen depends on the standard durable years and safety factors of the greenhouse. This study was carried out to find the standard durable years of pipe framed greenhouses. Bend test for metallic materials was conducted on samples of galvanized steel pipes being used in greenhouse frames. A secular change of collapse loads and flexural rigidity for galvanized steel pipes were analyzed with the parts buried in the ground and exposed in the atmosphere. From those experimental results and corrosion rate of galvanized film, the standard durable years for pipe framed greenhouses are estimated as follows ; the small scale pipe houses of movable type is 7∼8 years and the large scale pipe houses of fixed type is 14∼15 years.

  • PDF

Damping-off of Indian Lettuce Caused by Rhizoctonia solani AG-4

  • Moon, Youn-Gi;Kim, Se-Won;Seo, Hyun-Taek;Kim, Wan-Gyu
    • The Korean Journal of Mycology
    • /
    • v.48 no.4
    • /
    • pp.519-521
    • /
    • 2020
  • Damping-off symptoms were frequently observed on young plants of Indian lettuce (Lactuca indica) grown in a farmer's vinyl greenhouse located in Goseong, Gangwon province of Korea during a disease survey in June 2019. The incidence of diseased plants in the vinyl greenhouse investigated was 30-50%. Four isolates of Rhizoctonia sp. were obtained from the diseased plants and identified as Rhizoctonia solani AG-4 based on the morphological characteristics and anastomosis test. Three isolates of R. solani AG-4 were tested for pathogenicity on Indian lettuce by artificial inoculation. All the tested isolates induced damping-off symptoms on the inoculated plants. The symptoms were similar to those observed in plants from the farmer's vinyl greenhouse investigated. This is the first report of R. solani AG-4 causing damping-off in Indian lettuce.

Damping-off of Coastal Hogfennel Caused by Rhizoctonia solani AG-4

  • Moon, Youn-Gi;Kim, Se-Won;Seo, Hyun-Taek;Kim, Wan-Gyu
    • Research in Plant Disease
    • /
    • v.27 no.1
    • /
    • pp.45-47
    • /
    • 2021
  • Damping-off symptoms were frequently observed on young plants of coastal hogfennel (Peucedanum japonicum) grown in a farmer's vinyl greenhouse located in Goseong, Gangwon Province, Korea during a disease survey in June 2019. Incidence of the diseased plants was 50-70% in the vinyl greenhouse investigated during the disease survey. Eight isolates of Rhizoctonia sp. were obtained from the diseased plants. All the isolates were identified as Rhizoctonia solani AG-4 based on the morphological characteristics and anastomosis test. Three isolates of R. solani AG-4 were tested for pathogenicity on coastal hogfennel by artificial inoculation. All the tested isolates induced damping-off symptoms on the inoculated plants. The symptoms were similar to those observed in the farmer's vinyl greenhouse investigated. This is the first report of R. solani AG-4 causing damping-off in coastal hogfennel.

Damping-off of Deltoid Synurus Caused by Rhizoctonia solani AG-1 (IB)

  • Kim, Wan-Gyu;Lee, Gyo-Bin;Shim, Hong-Sik;Cho, Weon-Dae
    • The Korean Journal of Mycology
    • /
    • v.49 no.2
    • /
    • pp.249-251
    • /
    • 2021
  • Damping-off symptoms were frequently observed in young deltoid synurus (Synurus deltoides) plants grown in a farmer's vinyl greenhouse located in Hwacheon, Gangwon Province, Korea, during a disease survey in July 2019. The incidence of diseased plants in the vinyl greenhouse investigated was 5-30%. Five isolates of Rhizoctonia sp. were obtained from the diseased plants and identified as Rhizoctonia solani AG-1 (IB), based on morphological and cultural characteristics and anastomosis test results. Three isolates of R. solani AG-1 (IB) were tested for pathogenicity on deltoid synurus using artificial inoculation. All the tested isolates induced damping-off symptoms in the inoculated plants. The symptoms were similar to those observed in plants from the farmer's vinyl greenhouse. To our best knowledge, this is the first report of R. solani AG-1 (IB) causing damping-off in deltoid synurus.

Development of Greenhouse Environment Monitoring & Control System Based on Web and Smart Phone (웹과 스마트폰 기반의 온실 환경 제어 시스템 개발)

  • Kim, D.E.;Lee, W.Y.;Kang, D.H.;Kang, I.C.;Hong, S.J.;Woo, Y.H.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.18 no.1
    • /
    • pp.101-112
    • /
    • 2016
  • Monitoring and control of the greenhouse environment play a decisive role in greenhouse crop production processes. The network system for greenhouse control was developed by using recent technologies of networking and wireless communications. In this paper, a remote monitoring and control system for greenhouse using a smartphone and a computer with internet has been developed. The system provides real-time remote greenhouse integrated management service which collects greenhouse environment information and controls greenhouse facilities based on sensors and equipments network. Graphical user interface for an integrated management system was designed with bases on the HMI and the experimental results showed that a sensor data and device status were collected by integrated management in real-time. Because the sensor data and device status can be displayed on a web page, transmitted using the server program to remote computer and mobile smartphone at the same time. The monitored-data can be downloaded, analyzed and saved from server program in real-time via mobile phone or internet at a remote place. Performance test results of the greenhouse control system has confirmed that all work successfully in accordance with the operating conditions. And data collections and display conditions, event actions, crops and equipments monitoring showed reliable results.

A Study on the Emission Characteristics of Greenhouse Gas by Cumulative Mileage of Gasoline Vehicle (가솔린 차량의 누적주행거리에 따른 온실가스 배출특성 연구)

  • Park, Jin-sung;Lim, Jae-Hyuk;Kim, Ki-Ho;Lee, Jung-Min
    • Journal of ILASS-Korea
    • /
    • v.23 no.4
    • /
    • pp.227-233
    • /
    • 2018
  • An automobile is composed of a combination of a lot of parts, and it is difficult to maintain the same performance from a new car until it's scrapped. Greenhouse gases included in automobile emissions are typically carbon dioxide and methane. It is expected that this greenhouse gas will change depending on the aging (cumulative mileage) of the automobile However, the greenhouse gas characteristics by cumulative mileage lack of actual data due to time and economic difficulties. Therefore, in this paper, we selected automobile with high sales by displacement in korea and carbon dioxide and methane were measured by using method of the related law. The cumulative mileage is as follows; within 160 km (Statutory mileage by 2010), 6500 km (current statutory mileage), 15000 km (approximately 1-year average mileage of Non-business passenger vehicle). As a result of the test, the emission of carbon dioxide and methane was the smallest at 6,500 km, and increased in order of 15000 km, within 160 km. Also, it was confirmed that the $CO_2$ emission change of a large displacement automobile is more smaller at each mileage. Although the greenhouse gas tends to increase as the mileage of the vehicle, it is thought that additional confirmation is required of since 15,000 km as well, because it can occur deviations due to taming process or mechanical friction of the automobile.

Development of Clean Water Supplying System for Greenhouse Cultivation and Convenience Water (II) - Assessment of the FDA System through a Site Application - (시설용수 및 영농편의용수 공급시스템 개발 (II) - FDA 시스템 현장적용성 평가 -)

  • Lee, Kwang-Ya;Choi, Kyung-Sook
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.5
    • /
    • pp.101-106
    • /
    • 2009
  • The previous study developed the Filter-Disinfection-Adsorption (FDA) system to provide clean irrigation water for greenhouse cultivation as well as convenience water to farmers. In this study, the field examination was undertaken to assess performance of the FDA system. The field application was made in the suburb of Daegu, one of the large city in Korea. The study area located near by down-stream of Gum-Ho river is suffering low irrigation water quality problems with no water supply service facilities. Four water quality parameters including Suspended Solid (SS), Biological Oxygen Demand (BOD), coliform, and turbidity were selected to test the purification performance of FDA system. Also in order to improve the system, this study investigated the defects of using the FDA system through field monitoring. As results, it was found that this system can be used to supply good quality of irrigation water for greenhouse cultivation and also provide convenience water to farmers in the field areas of no water supply services.

A Study on Field test of the Horizontal Ground Source Heat Pump for Greenhouse (시설원예용 수평형 지열히트펌프 시스템 실증연구)

  • Park, Yong-Jung;Kang, Shin-Hyung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.505-510
    • /
    • 2007
  • Greenhouses should be heated during nights and co Id days in order to fit growth conditions in greenhouses. Ground source heat pump(GSHP) or geothermal heat pump system(GHPs) is recognized to be outstanding heating and cooling system. Horizontal GSHP system is typically less expensive than vertical GSHP system but requires wide ground area to bury ground heat exchanger (GHE). In this study, a horizontal GSHP system with thermal storage tank was installed in greenhouse and investigated as performance characteristics. In the daytime, heating load of greenhouse is very small or needless because solar radiation increases inner air temperature. The results of study showed that the heating coefficient of performance of the heat pump($COP_h$) was 2.9 and the overall heating coefficient of performance of the system($COP_{sys}$) was 2.4. Heating energy cost was saved 76% using the horizontal GSHP system with thermal storage tank.

  • PDF